Micro-Raman spectroscopy study of cancerous and normal nasopharyngeal tissues.

Abstract:

:The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngeal tissues were found, particularly in the spectral ranges of 853, 937, 1094, 1209, 1268, 1290 to 1340, 1579, and 1660 cm-1, which primarily contain signals related to proteins, DNA, and lipids. Compared to normal tissues, the band intensity located at 853, and 937 cm-1 were significantly lower for cancerous tissues (p<0.05), while the band intensity located at 1094, 1209, 1268, and 1579 cm-1 were significantly higher (p<0.05). The band intensity located at 1290 to 1340, and 1660 cm-1 were also higher for cancerous tissues; but the differences were not statistically significant (p>0.05). Principal component analysis (PCA) and linear discriminate analysis (LDA) were employed to generate diagnostic algorithms for classification of Raman spectra of the two nasopharyngeal tissue types. The PCA-LDA algorithms together with leave-one-out, cross-validation technique yielded diagnostic sensitivity of 92% and specificity of 82%. This work demonstrated that the Raman spectroscopy technique associated with PCA-LDA diagnostic algorithms has potential for improving the diagnosis of nasopharyngeal cancers.

journal_name

J Biomed Opt

authors

Li Y,Pan J,Chen G,Li C,Lin S,Shao Y,Feng S,Huang Z,Xie S,Zeng H,Chen R

doi

10.1117/1.JBO.18.2.027003

subject

Has Abstract

pub_date

2013-02-01 00:00:00

pages

27003

issue

2

eissn

1083-3668

issn

1560-2281

pii

1566747

journal_volume

18

pub_type

杂志文章
  • FLIM data analysis based on Laguerre polynomial decomposition and machine-learning.

    abstract:SIGNIFICANCE:The potential of fluorescence lifetime imaging microscopy (FLIM) is recently being recognized, especially in biological studies. However, FLIM does not directly measure the lifetimes, rather it records the fluorescence decay traces. The lifetimes and/or abundances have to be estimated from these traces dur...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.2.022909

    authors: Guo S,Silge A,Bae H,Tolstik T,Meyer T,Matziolis G,Schmitt M,Popp J,Bocklitz T

    更新日期:2021-01-01 00:00:00

  • Review of clinical approaches in fluorescence lifetime imaging ophthalmoscopy.

    abstract::Autofluorescence-based imaging techniques have become very important in the ophthalmological field. Being noninvasive and very sensitive, they are broadly used in clinical routines. Conventional autofluorescence intensity imaging is largely influenced by the strong fluorescence of lipofuscin, a fluorophore that can be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.9.091415

    authors: Sauer L,Andersen KM,Dysli C,Zinkernagel MS,Bernstein PS,Hammer M

    更新日期:2018-09-01 00:00:00

  • Screening for the breast cancer gene (BRCA1) using a biochip system and molecular beacon probes immobilized on solid surfaces.

    abstract::We describe the use of a biochip based on complementary metal oxide semiconductor (CMOS) technology for detection of specific genetic sequences using molecular beacons (MB) immobilized on solid surfaces as probes. The applicability of this miniature detection system for screening for the BRCA1 gene is evaluated using ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1691025

    authors: Culha M,Stokes DL,Griffin GD,Vo-Dinh T

    更新日期:2004-05-01 00:00:00

  • Infrared spectroscopic analysis of human and bovine articular cartilage proteoglycans using carbohydrate peak or its second derivative.

    abstract::Fourier transform infrared (FTIR) microspectroscopy has been used to estimate the spatial proteoglycan (PG) and collagen contents in articular cartilage (AC). However, it is not clear whether the results of FTIR analyses are consistent between different species. Our aim was to clarify how three different FTIR PG param...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.097006

    authors: Rieppo L,Närhi T,Helminen HJ,Jurvelin JS,Saarakkala S,Rieppo J

    更新日期:2013-09-01 00:00:00

  • In vivo microvascular network imaging of the human retina combined with an automatic three-dimensional segmentation method.

    abstract::Microvascular network of the retina plays an important role in diagnosis and monitoring of various retinal diseases. We propose a three-dimensional (3-D) segmentation method with intensity-based Doppler variance (IBDV) based on swept-source optical coherence tomography. The automatic 3-D segmentation method is used to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.076003

    authors: Huang S,Piao Z,Zhu J,Lu F,Chen Z

    更新日期:2015-07-01 00:00:00

  • Monitoring of drug and stimulation induced cerebral blood flow velocity changes in rat sensory cortex using spectral domain Doppler optical coherence tomography.

    abstract::Doppler optical coherence tomography (DOCT) provides a novel method to measure blood flow velocity in vessels with diameter at micrometer scale. In this study, a developed spectral domain DOCT system is applied to monitor cerebral blood flow velocity changes in a rat. An animal model with a cranial window is used, and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3560286

    authors: Wang C,Yang Y,Ding Z,Meng J,Wang K,Yang W,Xu Y

    更新日期:2011-04-01 00:00:00

  • Characterization of natural and irradiated nails by means of the depolarization metrics.

    abstract::Mueller polarimetry is applied to study the samples of nails: natural (or reference) and irradiated to 2 Gy ionizing radiation dose. We measure the whole Mueller matrices of the samples as a function of the scattering angle at a wavelength of 632.8 nm. We apply depolarization analysis to measured Mueller matrices by c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071108

    authors: Savenkov S,Priezzhev A,Oberemok Y,Sholom S,Kolomiets I,Chunikhina K

    更新日期:2016-07-01 00:00:00

  • Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

    abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.086003

    authors: Wall RA,Barton JK

    更新日期:2012-08-01 00:00:00

  • Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems.

    abstract::The excited state lifetime of a fluorophore together with its fluorescence emission spectrum provide information that can yield valuable insights into the nature of a fluorophore and its microenvironment. However, it is difficult to obtain both channels of information in a conventional scheme as detectors are typicall...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014506

    authors: Sagar MAK,Dai B,Chacko J,Weber J,Velten A,Sanders S,White J,Eliceiri K

    更新日期:2019-12-01 00:00:00

  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Graphics processing unit-based dispersion encoded full-range frequency-domain optical coherence tomography.

    abstract::Dispersion encoded full-range (DEFR) frequency-domain optical coherence tomography (FD-OCT) and its enhanced version, fast DEFR, utilize dispersion mismatch between sample and reference arm to eliminate the ambiguity in OCT signals caused by non-complex valued spectral measurement, thereby numerically doubling the usa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.077007

    authors: Wang L,Hofer B,Guggenheim JA,Povazay B

    更新日期:2012-07-01 00:00:00

  • "Seeing" electroencephalogram through the skull: imaging prefrontal cortex with fast optical signal.

    abstract::Near-infrared spectroscopy is a novel imaging technique potentially sensitive to both brain hemodynamics (slow signal) and neuronal activity (fast optical signal, FOS). The big challenge of measuring FOS noninvasively lies in the presumably low signal-to-noise ratio. Thus, detectability of the FOS has been controversi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3505007

    authors: Medvedev AV,Kainerstorfer JM,Borisov SV,Gandjbakhche AH,Vanmeter J

    更新日期:2010-11-01 00:00:00

  • Evidence of a heterogeneous tissue oxygenation: renal ischemia/reperfusion injury in a large animal model.

    abstract::Renal ischemia that occurs intraoperatively during procedures requiring clamping of the renal artery (such as renal procurement for transplantation and partial nephrectomy for renal cancer) is known to have a significant impact on the viability of that kidney. To better understand the dynamics of intraoperative renal ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.035001

    authors: Crane NJ,Huffman SW,Alemozaffar M,Gage FA,Levin IW,Elster EA

    更新日期:2013-03-01 00:00:00

  • Simultaneous imaging of multiple focal planes for three-dimensional microscopy using ultra-high-speed adaptive optics.

    abstract::Traditional white-light and fluorescent imaging techniques provide powerful methods to extract high-resolution information from two-dimensional (2-D) sections, but to retrieve information from a three-dimensional (3-D) volume they require relatively slow scanning methods that result in increased acquisition time. Usin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.5.050505

    authors: Duocastella M,Sun B,Arnold CB

    更新日期:2012-05-01 00:00:00

  • Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets.

    abstract::Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong abso...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.5.050503

    authors: Yamamoto N,Kawashima N,Kitazaki T,Mori K,Kang H,Nishiyama A,Wada K,Ishimaru I

    更新日期:2018-05-01 00:00:00

  • Characterizing depth-dependent refractive index of articular cartilage subjected to mechanical wear or enzymic degeneration.

    abstract::Utilizing a laser scanning confocal microscope system, the refractive indices of articular cartilage (AC) with mechanical or biochemical degenerations were characterized to investigate whether potential correlations exist between refractive index (RI) and cartilage degeneration. The cartilage samples collected from th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.095002

    authors: Wang K,Wu J,Day R,Kirk TB,Hu X

    更新日期:2016-09-01 00:00:00

  • Detrended fluctuation analysis of membrane flickering in discocyte and spherocyte red blood cells using quantitative phase microscopy.

    abstract::Dynamic analyses of vibrational motion in cell membranes provide a lot of information on the complex dynamic motilities of a red blood cell (RBC). Here, we present the correlation properties of membrane fluctuation in discocyte and spherocyte RBCs by using quantitative phase microscopy (QPM). Since QPM can provide nan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3601460

    authors: Lee S,Lee JY,Park CS,Kim DY

    更新日期:2011-07-01 00:00:00

  • Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina.

    abstract::This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642638

    authors: An L,Shen TT,Wang RK

    更新日期:2011-10-01 00:00:00

  • Combined ultrasound and photoacoustic imaging to detect and stage deep vein thrombosis: phantom and ex vivo studies.

    abstract::Treatment of deep venous thrombosis (DVT)--a primary cause of potentially fatal pulmonary embolism (PE)--depends on the age of the thrombus. The existing clinical imaging methods are capable of visualizing a thrombus but cannot determine the age of the blood clot. Therefore, there is a need for an imaging technique to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2992175

    authors: Karpiouk AB,Aglyamov SR,Mallidi S,Shah J,Scott WG,Rubin JM,Emelianov SY

    更新日期:2008-09-01 00:00:00

  • Quantum cascade laser-based hyperspectral imaging of biological tissue.

    abstract::The spectroscopy of analyte-specific molecular vibrations in tissue thin sections has opened up a path toward histopathology without the need for tissue staining. However, biomedical vibrational imaging has not yet advanced from academic research to routine histopathology due to long acquisition times for the microsco...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.111607

    authors: Kröger N,Egl A,Engel M,Gretz N,Haase K,Herpich I,Kränzlin B,Neudecker S,Pucci A,Schönhals A,Vogt J,Petrich W

    更新日期:2014-01-01 00:00:00

  • Measuring red blood cell flow dynamics in a glass capillary using Doppler optical coherence tomography and Doppler amplitude optical coherence tomography.

    abstract::Blood, being a suspension of deformable red cells suspended in plasma, displays flow dynamics considerably more complicated than those of an ideal Newtonian fluid. Flow dynamics in blood capillaries of a few hundred micrometers in diameter are investigated using Doppler optical coherence tomography (DOCT) and Doppler ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1781163

    authors: Moger J,Matcher SJ,Winlove CP,Shore A

    更新日期:2004-09-01 00:00:00

  • Monitoring the reduced scattering coefficient of bone tissues on the trajectory of pedicle screw placement using near-infrared spectroscopy.

    abstract::Pedicle screw (PS) fixation has been widely used for spine diseases. Scientists and clinicians employ several approaches to navigate PS during operation. We have demonstrated the feasibility of monitoring the reduced scattering coefficient (μ's) on the trajectory of PS using near-infrared spectroscopy (NIRS). To perfo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117002

    authors: Liu Y,Wang Y,Qian Z,Zhao J,Cao X,Li W

    更新日期:2014-01-01 00:00:00

  • Lesion strength control by automatic temperature guided retinal photocoagulation.

    abstract::Laser photocoagulation is an established treatment for a variety of retinal diseases. However, when using the same irradiation parameter, the size and strength of the lesions are unpredictable due to unknown inter- and intraindividual optical properties of the fundus layers. The aim of this work is to investigate a fe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.098001

    authors: Schlott K,Koinzer S,Baade A,Birngruber R,Roider J,Brinkmann R

    更新日期:2016-09-01 00:00:00

  • Computer model to investigate the effect of eye movements on retinal heating during long-duration fixation on a laser source.

    abstract::A computer simulation called RHME (Retinal Heating in Moving Eye) is developed to simulate the heating pattern that occurs in the retina during a long-duration exposure to a continuous wave laser beam. The simulation takes into account eye movements that occur during a deliberate fixation. Due to the rapid (millisecon...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1783355

    authors: Lund BJ

    更新日期:2004-09-01 00:00:00

  • Dependence of image quality on image operator and noise for optical diffusion tomography.

    abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429870

    authors: Chang J,Graber HL,Barbour RL

    更新日期:1998-04-01 00:00:00

  • Enhanced thulium fiber laser lithotripsy using micro-pulse train modulation.

    abstract::The thulium fiber laser (TFL) is currently being studied as an alternative to the conventional holmium:YAG (Ho:YAG) laser for lithotripsy. The diode-pumped TFL may be electronically modulated to operate with variable parameters (e.g., pulse rate, pulse duration, and duty cycle) for studying the influence of pulse trai...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.028002

    authors: Blackmon RL,Irby PB,Fried NM

    更新日期:2012-02-01 00:00:00

  • Methodology for examining polarized light interactions with tissues and tissuelike media in the exact backscattering direction.

    abstract::The properties of polarized light emerging from turbid media in the exact backscattering direction are studied by modulating the incident light polarization state and isolating the synchronous signal with lock-in amplifier detection. The results are reported for polystyrene microsphere suspensions in distilled water, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.430004

    authors: Studinski RC,Vitkin IA

    更新日期:2000-07-01 00:00:00

  • In vitro model for endogenous optical signatures of collagen.

    abstract::Type I collagen is a major component of the extracellular matrix as well as many tissue engineered models. To understand changes in collagen related models over time, it is important to evaluate collagen dynamics with noninvasive techniques. Fluorescence spectroscopy provides a method to noninvasively measure endogeno...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2360516

    authors: Kirkpatrick ND,Hoying JB,Botting SK,Weiss JA,Utzinger U

    更新日期:2006-09-01 00:00:00

  • Optical tweezers study of red blood cell aggregation and disaggregation in plasma and protein solutions.

    abstract::Kinetics of optical tweezers (OT)-induced spontaneous aggregation and disaggregation of red blood cells (RBCs) were studied at the level of cell doublets to assess RBC interaction mechanics. Measurements were performed under in vitro conditions in plasma and fibrinogen and fibrinogen + albumin solutions. The RBC spont...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.3.035001

    authors: Lee K,Kinnunen M,Khokhlova MD,Lyubin EV,Priezzhev AV,Meglinski I,Fedyanin AA

    更新日期:2016-03-01 00:00:00

  • Three-beam spectral-domain optical coherence tomography for retinal imaging.

    abstract::A three-beam spectral domain optical coherence tomography system (OCT) whose center wavelength is 840 nm was developed. The three beams focus on fundus 3.1 mm apart from each other and are detected by a single line sensor. The distance between the beams is fixed and the beams scan a total area of 10×10  mm² while keep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106001

    authors: Suehira N,Ooto S,Hangai M,Matsumoto K,Tomatsu N,Yuasa T,Yamada K,Yoshimura N

    更新日期:2012-10-01 00:00:00