Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

Abstract:

:Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an axial load or a torsional load. Additional tapers were loaded with 2 million cycles of axial compression or 2 million cycles of cantilever bending combined with axial compression, followed by axial distraction. The torsional and axial distraction loads increased linearly with the compressive load. Compared to a single compressive load application, cyclic axial loading had little influence on the joint strength, while a combination of axial loading and bending increased the joint strength. Based on these results, in vivo loading should increase the locking strength of Morse taper locks used for bone defect reconstruction.

journal_name

Biomed Mater Eng

authors

Duda GN,Elias JJ,Valdevit A,Chao EY

subject

Has Abstract

pub_date

1997-01-01 00:00:00

pages

277-84

issue

4

eissn

0959-2989

issn

1878-3619

journal_volume

7

pub_type

杂志文章
  • Influence of modified alginate hydrogels on mesenchymal stem cells and olfactory bulb-derived glial cells cultures.

    abstract:BACKGROUND:Great potential of cellular therapies has generated extensive research in the field of cells harvesting and culturing. Transplantation of cell cultures has been used in a variety of therapeutic programs but in many cases it appeared that biomaterial scaffold or sheath would enhance cells regenerative potenti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140966

    authors: Marycz K,Szarek D,Grzesiak J,Wrzeszcz K

    更新日期:2014-01-01 00:00:00

  • Hyaluronic acid as an internal phase additive to obtain ofloxacin/PLGA microsphere by double emulsion method.

    abstract::Hyaluronic acid (HA) was used as an internal phase additive to improve the loading efficiency of ofloxacin, a hydrophilic drug encapsulated by hydrophobic polylactic-co-glycolic acid (PLGA) materials, through a double emulsion (water-in-oil-in-water) solvent extraction/evaporation method. Results from laser distributi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130863

    authors: Wu G,Chen L,Li H,Wang YJ

    更新日期:2014-01-01 00:00:00

  • Automatic analysis of image of surface structure of cell wall-deficient EVC.

    abstract::Some computer applications for cell characterization in medicine and biology, such as analysis of surface structure of cell wall-deficient EVC (El Tor Vibrio of Cholera), operate with cell samples taken from very small areas of interest. In order to perform texture characterization in such an application, only a few t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Li S,Hu K,Cai N,Su W,Xiong H,Lou Z,Lin T,Hu Y

    更新日期:2001-01-01 00:00:00

  • Does artificial aging correctly predict the long-term in-vivo degradation behavior in zirconia hip prostheses?

    abstract:BACKGROUND:Accelerated hydrothermal aging has long been one of the most widely accepted quality control tests for simulating low-temperature degradation (LTD) in zirconia-containing implants used in total hip arthroplasty (THA). However, it is still unclear how much consistency there is between the experimental predict...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201083

    authors: Tateiwa T,Takahashi Y,Pezzotti G,Shishido T,Masaoka T,Sano K,Yamamoto K

    更新日期:2020-01-01 00:00:00

  • Effect of cancellous bone on the functionally graded dental implant concept.

    abstract::In a previous work by the author [H.S. Hedia and M. Nemat-Alla, Design optimization of functionally graded dental implant, submitted to be published in the J. Bio-Medical Materials and Engineering], a functionally graded material dental implant was designed without cansellous bone in the model. In this investigation t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Hedia HS

    更新日期:2005-01-01 00:00:00

  • Computer-aided detection of lung nodules using outer surface features.

    abstract::In this study, a computer-aided detection (CAD) system was developed for the detection of lung nodules in computed tomography images. The CAD system consists of four phases, including two-dimensional and three-dimensional preprocessing phases. In the feature extraction phase, four different groups of features are extr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151418

    authors: Demir Ö,Yılmaz Çamurcu A

    更新日期:2015-01-01 00:00:00

  • Counter-propagation network with variable degree variable step size LMS for single switch typing recognition.

    abstract::Morse code is now being harnessed for use in rehabilitation applications of augmentative-alternative communication and assistive technology, including mobility, environmental control and adapted worksite access. In this paper, Morse code is selected as a communication adaptive device for disabled persons who suffer fr...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:

    authors: Yang CH,Luo CH,Yang CH,Chuang LY

    更新日期:2004-01-01 00:00:00

  • Mechanical properties of cancellous tissue in compression test and nanoindentation.

    abstract::The goal of the study was to determine material constants of cancellous tissue in a compression test taking into account stress-strain characteristics. The nineteen test samples were resected from a femoral head of a patient qualified for a hip replacement surgery. During the compression tests, load-displacement curve...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-180999

    authors: Kokot G,Makuch A,Skalski K,Bańczerowski J

    更新日期:2018-01-01 00:00:00

  • Effect of platelet-rich plasma on bone engineering with an alloplastic substitute containing BMP2.

    abstract::A robust method for inducing bone-formation without an autograft has not been established. Currently, both platelet-rich plasma (PRP) and bone morphogenetic protein (BMP) have been widely investigated for their clinical use in such cases. However, their synergistic effect is still controversial and previously shown di...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130741

    authors: Yoshida K,Sumita Y,Marukawa E,Harashima M,Asahina I

    更新日期:2013-01-01 00:00:00

  • Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.

    abstract::The fretting corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium ball-and-socket-joint with tetrafluoroethylene under mechanical load. ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gil FJ,Canedo R,Padrós A,Bañeres MV,Arano JM

    更新日期:2003-01-01 00:00:00

  • Calcium phosphate fibers coated with collagen: In vivo evaluation of the effects on bone repair.

    abstract::The aim of this study was to assess the characteristics of the CaP/Col composites, in powder and fiber form, via scanning electron microscopy (SEM), pH and calcium release evaluation after immersion in SBF and to evaluate the performance of these materials on the bone repair process in a tibial bone defect model. For ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161581

    authors: Ueno FR,Kido HW,Granito RN,Gabbai-Armelin PR,Magri AM,Fernandes KR,da Silva AC,Braga FJ,Renno AC

    更新日期:2016-08-12 00:00:00

  • Sterilization of auto-crosslinked hyaluronic acid scaffolds structured in microparticles and sponges.

    abstract::This work evaluated the effects of UV irradiation, plasma radiation, steam and 70% ethanol treatments on the sterilization and integrity of auto-crosslinked hyaluronic acid (HA-ACP) scaffolds structured in microparticles and sponges aiming in vivo applications for regenerative medicine of bone tissue. The integrity of...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151558

    authors: Shimojo AA,de Souza Brissac IC,Pina LM,Lambert CS,Santana MH

    更新日期:2015-01-01 00:00:00

  • Titanium-porcelain system. Part II: Bond strength of fired porcelain on nitrided pure titanium.

    abstract::Commercially pure titanium (CPT) substrate was subjected to porcelain firing and bond strengths under three-point bending mode (span length: 15 mm; crosshead speed: 0.5 mm/min) were evaluated. Experimental variables included surface treatments of CPT and porcelain firing schedules. Variables for the surface treatments...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshida Y,Fung LW,Isikbay SC

    更新日期:1997-01-01 00:00:00

  • Optimal subband Kalman filter for normal and oesophageal speech enhancement.

    abstract::This paper presents the single channel speech enhancement system using subband Kalman filtering by estimating optimal Autoregressive (AR) coefficients and variance for speech and noise, using Weighted Linear Prediction (WLP) and Noise Weighting Function (NWF). The system is applied for normal and Oesophageal speech si...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141183

    authors: Ishaq R,García Zapirain B

    更新日期:2014-01-01 00:00:00

  • Application of polyethylene air-bubble cushions to improve the shock absorption performance of Type I construction helmets for repeated impacts.

    abstract:BACKGROUND:The use of helmets was considered to be one of the important prevention strategies employed on construction sites. The shock absorption performance of a construction (or industrial) helmet is its most important performance parameter. Industrial helmets will experience cumulative structural damage when being ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201132

    authors: Wu JZ,Pan CS,Ronaghi M,Wimer BM,Reischl U

    更新日期:2021-01-01 00:00:00

  • Effect of stenosis on hemodynamics in left coronary artery based on patient-specific CT scan.

    abstract:BACKGROUND:The most common cause of coronary artery disease (CAD) is vascular damage with the cholesterol built-up and other materials on the inner arterial wall, known as atherosclerosis. OBJECTIVE:This paper aims to investigate the effect of stenosis on the hemodynamics in the four suspected coronary artery disease ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191067

    authors: Kamangar S,Salman Ahmed NJ,Badruddin IA,Al-Rawahi N,Husain A,Govindaraju K,Yunus Khan TM

    更新日期:2019-01-01 00:00:00

  • Evaluation of chondrocytes expression embedded in thermoresponsive poly(amino acid)s with sol-gel transition.

    abstract::Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chueh SK,Tachibana Y,Uyama H,Kobayashi S,Tomita N

    更新日期:2007-01-01 00:00:00

  • Mechanical loading characteristics of total hip prosthetics subjected to dynamic loading cycles.

    abstract::The selection of best material pair in the hip prosthetics design for improved performance and life relies on the estimation of hip joint contact stresses and contact pressure distribution during various dynamic loading cycles: Climbing Upstairs, Climbing downstairs and Knee bending. The maximum Von Mises stress, cont...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181019

    authors: Kalayarasan M,Shankar S,Manikandan M,Adithan K

    更新日期:2018-01-01 00:00:00

  • MicroRNAs: potential biomarkers for disease diagnosis.

    abstract::MicroRNAs (miRNAs) are a group of endogenous noncoding small RNAs characterized by high conservation; furthermore, various studies have shown the capability of miRNAs to impact diseases. For example, a study shows that cell-free miRNAs are stable in bodily fluids, which gives circulating miRNAs the ability to be poten...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-141223

    authors: Xu L,Qi X,Duan S,Xie Y,Ren X,Chen G,Yang X,Han L,Dong Q

    更新日期:2014-01-01 00:00:00

  • Experimental exploration of mouse kidney imaging with the SR PCI technology.

    abstract::This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value of kidney imaging with phase contrast imaging technology. In our experiment, spatial resolution and tissue contrast serve as element evaluation and comparison....

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130917

    authors: Xia C,Peng YF,Arun KY,Xiao T,Zhu P,He W

    更新日期:2014-01-01 00:00:00

  • A novel registration method for image-guided neurosurgery system based on stereo vision.

    abstract::This study presents a novel spatial registration method of Image-guided neurosurgery system (IGNS) based on stereo-vision. Images of the patient's head are captured by a video camera, which is calibrated and tracked by an optical tracking system. Then, a set of sparse facial data points are reconstructed from them by ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151391

    authors: An Y,Wang M,Song Z

    更新日期:2015-01-01 00:00:00

  • The fracture toughness characteristics of three dental composite resins.

    abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

    更新日期:1991-01-01 00:00:00

  • The effect of counter-ions on the ion selectivity of potassium and sodium ions in nanopores.

    abstract::The ion selective transport plays an important role in the function of cell membranes, and promotes the application of artificial permeable membranes. This phenomenon has been studied in case for different diameters and functional groups of nanopores. In this work, we focus on the effect of anions on cation selectivit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130822

    authors: Tang D,Kim D

    更新日期:2014-01-01 00:00:00

  • Ultrasonic study of processed milk cream and vegetable oils.

    abstract::Food systems are complex and inhomogeneous in nature. Ultrasonic propagation velocity in the food systems, in this case processed milk cream and vegetable oils, is studied. Ultrasonic properties of the food systems are similar to those of complex biological tissues. The presence of vegetable oil as an adulterant in th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Singh VR,Kumar A

    更新日期:1992-04-01 00:00:00

  • Use of enzyme-linked immunosorbent assay (ELISA) for detection and quantification of monoclonal antibodies.

    abstract::The thrust of the present work is the demonstration of the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of a monoclonal antibody human serum. The antibodies used, 7E3 and D3GP3, have been proposed as platelet receptor blockers, being directed specifically again...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G

    更新日期:1994-01-01 00:00:00

  • Inorganic phosphate (Pi) modulates the expression of key regulatory proteins of the inorganic pyrophosphate (PPi) metabolism in TGF-β1-stimulated chondrocytes.

    abstract::The balance between extracellular inorganic phosphate (ePi) and extracellular inorganic pyrophosphate (ePPi) is controlled by four membrane proteins: the transporters ANK (exporting PPi outside the cells) and PiT-1 (importing ePi into the cells), and the enzymes PC-1 (generating ePPi from nucleotides) and Tissue Non-s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0634

    authors: Hamade T,Bianchi A,Sebillaud S,Netter P,Jouzeau JY,Cailotto F

    更新日期:2010-01-01 00:00:00

  • Studies on quantitative analysis and automatic recognition of cell types of lung cancer.

    abstract::Recognition of lung cancer cells is very important to the clinical diagnosis of lung cancer. In this paper we present a novel method to extract the structure characteristics of lung cancer cells and automatically recognize their types. Firstly soft mathematical morphology methods are used to enhance the grayscale imag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chen YC,Hu KH,Li FZ,Li SY,Su WF,Huang ZY,Hu YX

    更新日期:2006-01-01 00:00:00

  • Automatic recognition of facial movement for paralyzed face.

    abstract::Facial nerve paralysis is a common disease due to nerve damage. Most approaches for evaluating the degree of facial paralysis rely on a set of different facial movements as commanded by doctors. Therefore, automatic recognition of the patterns of facial movement is fundamental to the evaluation of the degree of facial...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141093

    authors: Wang T,Dong J,Sun X,Zhang S,Wang S

    更新日期:2014-01-01 00:00:00

  • Nondestructive analysis of dielectric properties: application to ion beam irradiated tissue response microfibre.

    abstract::The aim of this work was to investigate the effect of 2.4 MeV proton irradiation on the dielectric property of polyethylene terephthalate (PET) microfibre nondestructively. The dielectric constant εd of single-microfibre has been measured as-such applying laser diffraction technique. Applying this methodology εd is fo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130947

    authors: Mallick B

    更新日期:2014-01-01 00:00:00

  • Evaluation of the pro-angiogenic effect of nanoscale extracellular vesicles derived from human umbilical cord mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are a common tool in regenerative medicine. The nanoscale extracellular vesicles (nEVs) secreted by these cells were recently brought up to light thanks to their therapeutic potential. In this study, we assessed the in vitro behaviour of human umbilical vein endothelial cells (HUVECs) exp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171626

    authors: Dostert G,Willemin AS,Jouan-Hureaux V,Louis H,Hupont S,Gillet P,Menu P,Decot V,Moby V,Velot É

    更新日期:2017-01-01 00:00:00