Effect of stenosis on hemodynamics in left coronary artery based on patient-specific CT scan.

Abstract:

BACKGROUND:The most common cause of coronary artery disease (CAD) is vascular damage with the cholesterol built-up and other materials on the inner arterial wall, known as atherosclerosis. OBJECTIVE:This paper aims to investigate the effect of stenosis on the hemodynamics in the four suspected coronary artery disease patients. Computer tomography (CT) data was acquired from patients of suspected coronary artery disease to reconstruct left coronary artery. METHODS:The 3D computational simulation was carried out with four patient-specific models with area stenosis >50% located at the left anterior descending (LAD) and left circumflex (LCX) branches. RESULTS:The pressure, velocity and wall shear stress were calculated during the cardiac cycle. A significant pressure drop across the stenosis and increase in the velocity at the stenosis were observed at LAD and LCX branches. An increase in the wall shear stress in the region of stenosis also observed with the prevalence of the recirculation zone at the post stenosis region which results in the formation of stenosis. CONCLUSIONS:Our analysis provides an insight into the progression of stenosis and wall rupture, thus improving our understanding the flow behavior patient-specific realistic artery models.

journal_name

Biomed Mater Eng

authors

Kamangar S,Salman Ahmed NJ,Badruddin IA,Al-Rawahi N,Husain A,Govindaraju K,Yunus Khan TM

doi

10.3233/BME-191067

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

463-473

issue

4

eissn

0959-2989

issn

1878-3619

pii

BME191067

journal_volume

30

pub_type

杂志文章
  • Characterization and human osteoblastic proliferation- and differentiation-stimulatory effects of phosphatidylcholine liposomes-encapsulated propranolol hydrochloride.

    abstract::DMPC and DSPC liposomes were prepared via thin film hydration method followed by sonication. Propranolol solution was incorporated into liposomes at hydration stage. TEM images showed the sizes of DSPC and DMPC were around 88 and 137 nm, respectively. The highest encapsulation ratio of propranolol was approximately 70...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140997

    authors: Teong B,Kuo SM,Chen CH,Chen YK,Cheng ZJ,Huang HH

    更新日期:2014-01-01 00:00:00

  • 4D model of hemodynamics in the abdominal aorta.

    abstract::The paper presents an application of the FSI technique to determine hemodynamics in the abdominal aorta (AA). To establish boundary conditions for the FSI study, MR anatomical data and 4D MRI velocity-mapping data (in three blood flow velocity directions and time) were collected to acquire realistic geometry of the AA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151312

    authors: Zbicinski I,Veshkina N,Stefańczyk L

    更新日期:2015-01-01 00:00:00

  • Cellular compatibility of highly degradable bioactive ceramics for coating of metal implants.

    abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0678

    authors: Radetzki F,Wohlrab D,Zeh A,Delank KS,Mendel T,Berger G,Syrowatka F,Mayr O,Bernstein A

    更新日期:2011-01-01 00:00:00

  • Does adipose tissue cultured with collagen matrix and preadipocytes give comparable results to the standard technique in plastic surgery?

    abstract:INTRODUCTION:Repairing contour defects is a challenge in plastic surgery. Different filling materials have been used with inadequate results and complications. The autologous fat transfer is the standard technique at the moment, but adipose tissue reserves are limited. The aim of our study was to compare in vivo on an ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Mojallal A,Lequeux C,Auxenfans C,Braye F,Damour O

    更新日期:2008-01-01 00:00:00

  • Real-time 3D visual tracking of laparoscopic instruments for robotized endoscope holder.

    abstract::Robotized endoscope holder in laparoscopic surgeries allows surgeons to control the endoscope without the assistants' intervention. In this paper, a new method is proposed for the automatic 3D-tracking of laparoscopic instruments in real-time to provide more convenient interactions between surgeons and the robotized e...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141083

    authors: Zhao Z

    更新日期:2014-01-01 00:00:00

  • Dentin bonding system. Part I: Literature review.

    abstract::Currently, clinicians face choices of restoration including amalgams (mercury-based, gallium-based alloys, or mercury-free silver-based substitutes), composite resins, ceramics, and gold alloy. In order to choose an appropriate restorative material, many parameters are involved; they include preparation time requireme...

    journal_title:Bio-medical materials and engineering

    pub_type: 历史文章,杂志文章,评审

    doi:

    authors: Miyazaki M,Oshida Y,Xirouchaki L

    更新日期:1996-01-01 00:00:00

  • Tight medial knot tying may increase retearing risk after transosseous equivalent repair of rotator cuff tendon.

    abstract:BACKGROUND:Retearing mechanism after transosseous equivalent (TOE) rotator cuff repair has not been fully clarified yet. OBJECTIVE:The purposes of this study were to compare the stress distribution pattern in the tendon stump between knotted and knotless TOE repair and to investigate the role of suture tension applied...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171673

    authors: Sano H,Tokunaga M,Noguchi M,Inawashiro T,Irie T,Abe H,Yokobori AT

    更新日期:2017-01-01 00:00:00

  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00

  • Replica-based inspection of enamel wear microfeatures.

    abstract:BACKGROUND:Surface replication is a nondestructive evaluation technique applied in examining surface wear by recording surface irregularities, especially in conditions when surfaces of interest cannot be further manipulated to fit directly under a microscope to be examined. Enamel is the outermost protective layer of t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206006

    authors: Ijbara M,Wada K,Wada J,Jayawardena JA,Miyashin M

    更新日期:2020-01-01 00:00:00

  • Failed attempts and improvement strategies in peripheral intravenous catheterization.

    abstract:BACKGROUND:Access to peripheral veins is necessary for sample collection, transfusion and infusion of fluids or medications. The peripheral intravenous catheterization (PIVC) procedure is the introduction of a short catheter into a peripheral vein and can be problematic, leading to multiple failed attempts. PURPOSE:To...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-120735

    authors: Sabri A,Szalas J,Holmes KS,Labib L,Mussivand T

    更新日期:2013-01-01 00:00:00

  • A statistical approach to segmentation of diffusion tensor imaging.

    abstract::The aim of this study is to design a statistical segmentation technique to allow extraction of grey matter, white matter and cerebral spinal fluid volumes from diffusion tensor imaging. Four channel maps of the DTI are used as the input features, which provide more information for brain tissue segmentation compared wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130927

    authors: Wen Y,He L

    更新日期:2014-01-01 00:00:00

  • Aligned polyvinylpyrrolidone nanofibers with advanced electrospinning for biomedical applications.

    abstract:BACKGROUND:Electrospinning is a highly effective method in order to generate nano-scaled fibers. In conventional electrospinning technique, geometry of nanofibers are mostly random due to the chaotic behavior of polymer jet. OBJECTIVE:Purpose of this study is to produce aligned nanofibers from PVP polymers with advanc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181017

    authors: Karayeğen G,Koçum IC,Çökeli Ler Serdaroğlu D,Doğan M

    更新日期:2018-01-01 00:00:00

  • Carbonate hydroxyapatite gel monolith formation and drying.

    abstract::The effect of carbonate in reducing the crystal size of precipitated hydroxyapatite by approximately an order of magnitude has not been used previously in the preparation of gel monoliths for the fabrication of carbonate hydroxyapatite ceramics. The aim of this study was to devise a method whereby gel monoliths of car...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Barralet JE,Best SM,Bonfield W

    更新日期:1996-01-01 00:00:00

  • Regulation of periodontal ligament-derived cells by type III collagen-coated hydroxyapatite.

    abstract:BACKGROUND:The periodontal ligament (PDL), which maintains homeostasis in the periodontium, is a group of specialized connective tissue fibers attached to both the cementum and alveolar bone. Regeneration of periodontium with PDL cells has been investigated, and the chemical and molecular structures of scaffolds contro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171709

    authors: Fujita K,Nozaki K,Horiuchi N,Yamashita K,Miura H,Nagai A

    更新日期:2018-01-01 00:00:00

  • Bioshell calcium oxide (BiSCaO) for cleansing and healing Pseudomonas aeruginosa-infected wounds in hairless rats.

    abstract:BACKGROUND:Scallop shell powder is called bioshell calcium oxide (BiSCaO), which is known to possess deodorizing properties and broad antimicrobial activity against various pathogenic microbes, including viruses, bacteria, spores, and fungi. OBJECTIVE:This study aims to investigate the applications of BiSCaO suspensio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201082

    authors: Takayama T,Ishihara M,Sato Y,Nakamura S,Fukuda K,Murakami K,Yokoe H

    更新日期:2020-01-01 00:00:00

  • In vivo study of osteogenerating properties of calcium-phosphate coating on titanium alloy Ti-6Al-4V.

    abstract::The method of formation of bioactive calcium-phosphate coating on medical titanium alloy Ti-6Al-4V (3.5-5.3% V; 5.3-6.8% Al; balance -Ti) by plasma electrolytic oxidation (PEO) has been developed. Evaluation of osteogenerating properties of the coating at fractures of the shaft of the femur on Wistar line laboratory r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161608

    authors: Gnedenkov SV,Sinebryukhov SL,Puz AV,Egorkin VS,Kostiv RE

    更新日期:2016-01-01 00:00:00

  • Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130811

    authors: Yu CH,Piao YJ,Kim K,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Enhanced oral bioavailability and antiasthmatic efficacy of curcumin using redispersible dry emulsion.

    abstract::Dry emulsion containing curcumin (DE-CUR) was prepared for oral delivery of poorly water-soluble curcumin, and its oral bioavailability and antiasthmatic efficacy was evaluated. After comparison of the solubility of curcumin in various oils, Plurol® Oleique CC497 was selected to be the oil phase due to its higher solu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130886

    authors: Jang DJ,Kim ST,Oh E,Lee K

    更新日期:2014-01-01 00:00:00

  • Experimental exploration of mouse kidney imaging with the SR PCI technology.

    abstract::This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value of kidney imaging with phase contrast imaging technology. In our experiment, spatial resolution and tissue contrast serve as element evaluation and comparison....

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130917

    authors: Xia C,Peng YF,Arun KY,Xiao T,Zhu P,He W

    更新日期:2014-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Computer-aided detection of lung nodules using outer surface features.

    abstract::In this study, a computer-aided detection (CAD) system was developed for the detection of lung nodules in computed tomography images. The CAD system consists of four phases, including two-dimensional and three-dimensional preprocessing phases. In the feature extraction phase, four different groups of features are extr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151418

    authors: Demir Ö,Yılmaz Çamurcu A

    更新日期:2015-01-01 00:00:00

  • Theoretical foundation on a noninvasive estimation for viscoelastic mechanical property of blood vessels by ultrasonic Doppler effect.

    abstract::The method used in this paper is developed to estimate the degree of viscoelasticity of the blood vessel wall in a noninvasive mechanical method. In this proposed method, we can obtain an output waveform connected with mechanical behavior of blood vessels by using Ultrasonic Doppler Effect Sensory (UDES). Characterizi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Yoshinari H,Yokobori AT Jr,Ohkuma T

    更新日期:1994-01-01 00:00:00

  • A comparison study on the flexural strength and compressive strength of four resin-modified luting glass ionomer cements.

    abstract::The purpose of this study is to compare the differences in flexural strength and compressive strength between four resin-modified luting glass ionomer cements that are commonly used in clinics. Furthermore, this study investigates the influence of curing mode on the flexural strength and compressive strength of dual-c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151284

    authors: Li Y,Lin H,Zheng G,Zhang X,Xu Y

    更新日期:2015-01-01 00:00:00

  • A study of quality control method for IMRT planning based on prior knowledge and novel measures derived from both OVHs and DVHs.

    abstract::Intensity-Modulated Radiation Therapy (IMRT) mathematically forms a large-scale optimization problem. The development of an IMRT plan is computationally expensive resulting in time-consuming, inefficient, and difficult to develop high-quality IMRT plans. By combining prior knowledge with proposed novel measures derive...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141173

    authors: Zhou Z,Chen Y,Yu Z,Wang D,Zhao C,Xu J,Song W,Li B,Shen J,Zhu X

    更新日期:2014-01-01 00:00:00

  • SAR and thermal response effects of a two-arm Archimedean spiral coil in a magnetic induction sensor on a human head.

    abstract::This study investigates the radiation safety of a newly designed magnetic induction sensor. This novel magnetic induction sensor uses a two-arm Archimedean spiral coil (TAASC) as the exciter. A human head model with a real anatomical structure was used to calculate the specific absorption rate (SAR) and temperature ch...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151329

    authors: Zhang Z,Liu P,Zhou D,Zhang L,Ding L

    更新日期:2015-01-01 00:00:00

  • Analysis of basal physical fitness and lumbar muscle function according to indoor horse riding exercise.

    abstract::The aim of this study is to verify the effect of indoor horse riding exercise on basal physical exercise and lumbar muscular function. The subjects included were 20 healthy females, who participated in the horse riding exercise using SRider (Rider Co. & ChonbuK National Univ, Korea) for 30 minutes per day, 3 days per ...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-141053

    authors: Yu CH,Hong CU,Kang SR,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Inorganic phosphate (Pi) modulates the expression of key regulatory proteins of the inorganic pyrophosphate (PPi) metabolism in TGF-β1-stimulated chondrocytes.

    abstract::The balance between extracellular inorganic phosphate (ePi) and extracellular inorganic pyrophosphate (ePPi) is controlled by four membrane proteins: the transporters ANK (exporting PPi outside the cells) and PiT-1 (importing ePi into the cells), and the enzymes PC-1 (generating ePPi from nucleotides) and Tissue Non-s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0634

    authors: Hamade T,Bianchi A,Sebillaud S,Netter P,Jouzeau JY,Cailotto F

    更新日期:2010-01-01 00:00:00

  • Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    abstract::Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151427

    authors: Zhang Y,Gao Y,Li H,Teng Y,Kang Y

    更新日期:2015-01-01 00:00:00

  • Extracellular matrices as advanced scaffolds for vascular tissue engineering.

    abstract::An alternative non-vascular extracellular material was obtained by decellularisation of porcine urinary bladder and examined for its potential as scaffold for vascular tissue engineering. Analysis using Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Laser Scanning Microscopy (LSCM) showed a poro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0598

    authors: Piterina AV,Callanan A,Davis L,Meaney C,Walsh M,McGloughlin TM

    更新日期:2009-01-01 00:00:00