听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览BIO-MEDICAL MATERIALS AND ENGINEERING期刊下所有文献
  • Application of polyethylene air-bubble cushions to improve the shock absorption performance of Type I construction helmets for repeated impacts.

    abstract:BACKGROUND:The use of helmets was considered to be one of the important prevention strategies employed on construction sites. The shock absorption performance of a construction (or industrial) helmet is its most important performance parameter. Industrial helmets will experience cumulative structural damage when being ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201132

    authors: Wu JZ,Pan CS,Ronaghi M,Wimer BM,Reischl U

    更新日期:2021-01-01 00:00:00

  • Does artificial aging correctly predict the long-term in-vivo degradation behavior in zirconia hip prostheses?

    abstract:BACKGROUND:Accelerated hydrothermal aging has long been one of the most widely accepted quality control tests for simulating low-temperature degradation (LTD) in zirconia-containing implants used in total hip arthroplasty (THA). However, it is still unclear how much consistency there is between the experimental predict...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201083

    authors: Tateiwa T,Takahashi Y,Pezzotti G,Shishido T,Masaoka T,Sano K,Yamamoto K

    更新日期:2020-01-01 00:00:00

  • Replica-based inspection of enamel wear microfeatures.

    abstract:BACKGROUND:Surface replication is a nondestructive evaluation technique applied in examining surface wear by recording surface irregularities, especially in conditions when surfaces of interest cannot be further manipulated to fit directly under a microscope to be examined. Enamel is the outermost protective layer of t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206006

    authors: Ijbara M,Wada K,Wada J,Jayawardena JA,Miyashin M

    更新日期:2020-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • Adipose tissue regeneration in a 3D-printed poly(lactic acid) frame-supported space in the inguinal region of rats.

    abstract:BACKGROUND:Adipose tissue engineering has been studied as an alternative to current options for breast reconstruction, such as lipofilling, flap reconstruction, and silicone implants. Previously, we demonstrated that a poly(L-lactic acid) mesh containing a collagen sponge, containing neither cells nor growth factors, c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201103

    authors: Kambe Y,Ogino S,Yamanaka H,Morimoto N,Yamaoka T

    更新日期:2020-01-01 00:00:00

  • Phosphorylated chitin increased bone formation when implanted into rat calvaria with the Ti-device.

    abstract:BACKGROUND:Previously we found that a group of phosphorylated proteins (SIBLINGs) in bone binds with the Ti-device, and increases the early bone formation around the Ti-implants remarkably. From these results, we explained the biochemical mechanism of a strong bond between living bone and Ti, which was discovered by Br...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201079

    authors: Song Q,Yagami K,Furusawa T,Takita H,Kurasaki M,Tokura S,Morimoto K,Sammons R,Iku S,Kuboki Y

    更新日期:2020-01-01 00:00:00

  • Bioshell calcium oxide (BiSCaO) for cleansing and healing Pseudomonas aeruginosa-infected wounds in hairless rats.

    abstract:BACKGROUND:Scallop shell powder is called bioshell calcium oxide (BiSCaO), which is known to possess deodorizing properties and broad antimicrobial activity against various pathogenic microbes, including viruses, bacteria, spores, and fungi. OBJECTIVE:This study aims to investigate the applications of BiSCaO suspensio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201082

    authors: Takayama T,Ishihara M,Sato Y,Nakamura S,Fukuda K,Murakami K,Yokoe H

    更新日期:2020-01-01 00:00:00

  • Effect of stenosis on hemodynamics in left coronary artery based on patient-specific CT scan.

    abstract:BACKGROUND:The most common cause of coronary artery disease (CAD) is vascular damage with the cholesterol built-up and other materials on the inner arterial wall, known as atherosclerosis. OBJECTIVE:This paper aims to investigate the effect of stenosis on the hemodynamics in the four suspected coronary artery disease ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191067

    authors: Kamangar S,Salman Ahmed NJ,Badruddin IA,Al-Rawahi N,Husain A,Govindaraju K,Yunus Khan TM

    更新日期:2019-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • A novel diagnostic system for Doppler ultrasound of the peripheral arteries to detect the presence of thoracic aortic aneurysm.

    abstract:OBJECTIVE:We aimed to develop a novel ultrasound system and examine its feasibility for noninvasively detecting thoracic aortic aneurysm (TAA) in clinical settings. METHODS:We developed a novel ultrasound system consisting of a modified console and data analysis algorithm. The exploratory study included 100 patients h...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191047

    authors: Hayatsu Y,Watanabe K,Sasaki K,Masaki N,Katahira S,Kumagai K,Kawamoto S,Ohmi T,Yokobori AT Jr,Saiki Y

    更新日期:2019-01-01 00:00:00

  • Multiple platelet-rich plasma preparations can solubilize freeze-dried chitosan formulations to form injectable implants for orthopedic indications.

    abstract:BACKGROUND:Platelet-rich plasma (PRP) has been used to solubilize freeze-dried chitosan (CS) formulations to form injectable implants for tissue repair. OBJECTIVE:To determine whether the in vitro performance of the formulations depends on the type of PRP preparation used to solubilize CS. METHODS:Formulations contai...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191058

    authors: Ghazi Zadeh L,Chevrier A,Lamontagne M,Buschmann MD,Hoemann CD,Lavertu M

    更新日期:2019-01-01 00:00:00

  • Simultaneous quantitative analysis of indomethacin and benzoic acid in gel using ultra-violet-visible spectrophotometry and chemometrics.

    abstract:BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out qu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181034

    authors: Peerapattana J,Hattori Y,Otsuka M

    更新日期:2019-01-01 00:00:00

  • Aligned polyvinylpyrrolidone nanofibers with advanced electrospinning for biomedical applications.

    abstract:BACKGROUND:Electrospinning is a highly effective method in order to generate nano-scaled fibers. In conventional electrospinning technique, geometry of nanofibers are mostly random due to the chaotic behavior of polymer jet. OBJECTIVE:Purpose of this study is to produce aligned nanofibers from PVP polymers with advanc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181017

    authors: Karayeğen G,Koçum IC,Çökeli Ler Serdaroğlu D,Doğan M

    更新日期:2018-01-01 00:00:00

  • Regulation of periodontal ligament-derived cells by type III collagen-coated hydroxyapatite.

    abstract:BACKGROUND:The periodontal ligament (PDL), which maintains homeostasis in the periodontium, is a group of specialized connective tissue fibers attached to both the cementum and alveolar bone. Regeneration of periodontium with PDL cells has been investigated, and the chemical and molecular structures of scaffolds contro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171709

    authors: Fujita K,Nozaki K,Horiuchi N,Yamashita K,Miura H,Nagai A

    更新日期:2018-01-01 00:00:00

  • Development of asymmetric stent for treatment of eccentric plaque.

    abstract::The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat ecce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181737

    authors: Syaifudin A,Takeda R,Sasaki K

    更新日期:2018-01-01 00:00:00

  • Investigation of mechanical compatibility of hernia meshes and human abdominal fascia.

    abstract:OBJECTIVE:Understanding the biomechanical properties of hernia meshes is essential in facilitating their selection. The aim of this study was to evaluate the mechanical compatibility of hernia meshes and human abdominal fascia and assess their applicability in hernia repair. METHODS:Uniaxial tensile tests were perform...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171719

    authors: Doneva M,Pashkouleva D

    更新日期:2018-01-01 00:00:00

  • Mechanical loading characteristics of total hip prosthetics subjected to dynamic loading cycles.

    abstract::The selection of best material pair in the hip prosthetics design for improved performance and life relies on the estimation of hip joint contact stresses and contact pressure distribution during various dynamic loading cycles: Climbing Upstairs, Climbing downstairs and Knee bending. The maximum Von Mises stress, cont...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181019

    authors: Kalayarasan M,Shankar S,Manikandan M,Adithan K

    更新日期:2018-01-01 00:00:00

  • Mechanical properties of cancellous tissue in compression test and nanoindentation.

    abstract::The goal of the study was to determine material constants of cancellous tissue in a compression test taking into account stress-strain characteristics. The nineteen test samples were resected from a femoral head of a patient qualified for a hip replacement surgery. During the compression tests, load-displacement curve...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-180999

    authors: Kokot G,Makuch A,Skalski K,Bańczerowski J

    更新日期:2018-01-01 00:00:00

  • Increased intrinsic stiffness and mineralization in femurs of adult rats after high intensity treadmill running training.

    abstract:BACKGROUND:Physical activity plays a tremendous role in determining bone mechanical behavior, which is superimposed to gravidity. OBJECTIVE:Compare the geometric and material responses of the rat femur to a high intensity treadmill running training of a relatively short duration, as assessed by 3-point mechanical test...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171684

    authors: Bozzini C,Viscor G,Kristjánsson JCR,Picasso E,Champin G,Alippi RM,Bozzini CE

    更新日期:2017-01-01 00:00:00

  • Tight medial knot tying may increase retearing risk after transosseous equivalent repair of rotator cuff tendon.

    abstract:BACKGROUND:Retearing mechanism after transosseous equivalent (TOE) rotator cuff repair has not been fully clarified yet. OBJECTIVE:The purposes of this study were to compare the stress distribution pattern in the tendon stump between knotted and knotless TOE repair and to investigate the role of suture tension applied...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171673

    authors: Sano H,Tokunaga M,Noguchi M,Inawashiro T,Irie T,Abe H,Yokobori AT

    更新日期:2017-01-01 00:00:00

  • An improved finite element modeling of the cerebrospinal fluid layer in the head impact analysis.

    abstract::The finite element (FE) method has been widely used to investigate the mechanism of traumatic brain injuries (TBIs), because it is technically difficult to quantify the responses of the brain tissues to the impact in experiments. One of technical challenges to build a FE model of a human head is the modeling of the ce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171666

    authors: Wu JZ,Pan CS,Wimer BM,Rosen CL

    更新日期:2017-01-01 00:00:00

  • Evaluation of the pro-angiogenic effect of nanoscale extracellular vesicles derived from human umbilical cord mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are a common tool in regenerative medicine. The nanoscale extracellular vesicles (nEVs) secreted by these cells were recently brought up to light thanks to their therapeutic potential. In this study, we assessed the in vitro behaviour of human umbilical vein endothelial cells (HUVECs) exp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171626

    authors: Dostert G,Willemin AS,Jouan-Hureaux V,Louis H,Hupont S,Gillet P,Menu P,Decot V,Moby V,Velot É

    更新日期:2017-01-01 00:00:00

  • Multiphysics of bone remodeling: A 2D mesoscale activation simulation.

    abstract::In this work, we present an evolutive trabecular model for bone remodeling based on a boundary detection algorithm accounting for both biology and applied mechanical forces, known to be an important factor in bone evolution. A finite element (FE) numerical model using the Abaqus/Standard® software was used with a UMAT...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171636

    authors: Spingarn C,Wagner D,Rémond Y,George D

    更新日期:2017-01-01 00:00:00

  • Thyroid hormone disorders and sepsis.

    abstract::Sepsis is a systemic inflammatory response syndrome with high mortality, which results from severe infection and can lead to secondary organ dysfunction. It is one of the most common cause of death in intensive care unit. Clinical reports have shown that sepsis was often accompanied by thyroid dysfunction, which is ca...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-171646

    authors: Luo B,Yu Z,Li Y

    更新日期:2017-01-01 00:00:00

  • Synthesis and enhanced bone regeneration of carbonate substituted octacalcium phosphate.

    abstract::Using a wet method, we have synthesized octacalcium phosphate carbonate, in which HPO42- in octacalcium phosphate is replaced with CO32-. The physical, crystal, and chemical properties of this new material were compared to octacalcium phosphate, Ca-deficient hydroxyapatite, and Ca-deficient carbonate apatite using X-r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171651

    authors: Shen D,Horiuchi N,Nozaki S,Miyashin M,Yamashita K,Nagai A

    更新日期:2017-01-01 00:00:00

  • A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent.

    abstract:BACKGROUND:Stenting has been proposed as an effective treatment to restore blood flow in obstructed arteries by plaques. Although several modified designs for stents have been suggested, most designs have the risk of disturbing blood flow. OBJECTIVE:The main objective is to propose a stent design to attain a uniform l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171691

    authors: Beigzadeh B,Mirmohammadi SA,Ayatollahi MR

    更新日期:2017-01-01 00:00:00

  • Bone regeneration from human mesenchymal stem cells on porous hydroxyapatite-PLGA-collagen bioactive polymer scaffolds.

    abstract::We have developed a novel multicomponent nano-hydroxyapatite-poly(D,L-lactide-co-glycolide)-collagen biomaterial (nHAP-PLGA-collagen) with mechanical properties similar to human cancellous bone. To demonstrate the bone forming capacity of nHAP-PLGA-collagen prior to in vivo experiments, nHAP-PLGA-collagen films and 3D...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171703

    authors: Bhuiyan DB,Middleton JC,Tannenbaum R,Wick TM

    更新日期:2017-01-01 00:00:00

  • Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.

    abstract:BACKGROUND:Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. OBJECTIVE:To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompat...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161607

    authors: Nalbantgil D,Ulkur F,Kardas G,Culha M

    更新日期:2016-11-25 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis.

    abstract:BACKGROUND:The simulated Doppler blood flow signals are widely used to assess the performance of the clutter filters for removing wall components while reserving low-velocity signals scattered from physiological blood flow approaching the inner vessel-wall injured by a stenosed lesion. OBJECTIVE:By simultaneously taki...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161573

    authors: Gao L,Zhang Y,Zhou Y,Hu X,Deng L,Zhang K,Cai G,Zhang J

    更新日期:2016-08-12 00:00:00

  • Calcium phosphate fibers coated with collagen: In vivo evaluation of the effects on bone repair.

    abstract::The aim of this study was to assess the characteristics of the CaP/Col composites, in powder and fiber form, via scanning electron microscopy (SEM), pH and calcium release evaluation after immersion in SBF and to evaluate the performance of these materials on the bone repair process in a tibial bone defect model. For ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161581

    authors: Ueno FR,Kido HW,Granito RN,Gabbai-Armelin PR,Magri AM,Fernandes KR,da Silva AC,Braga FJ,Renno AC

    更新日期:2016-08-12 00:00:00

  • Biodegradable/biocompatible coated metal implants for orthopedic applications.

    abstract::Biocompatible metals have been suggested as revolutionary biomaterials for bone-grafting therapies. Although metals and their alloys are widely and successfully used in producing biomedical implants due to their good mechanical properties and corrosion resistance, they have a lack in bioactivity. Therefore coating of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-161568

    authors: Saleh MM,Touny AH,Al-Omair MA,Saleh MM

    更新日期:2016-05-12 00:00:00

  • In vivo study of osteogenerating properties of calcium-phosphate coating on titanium alloy Ti-6Al-4V.

    abstract::The method of formation of bioactive calcium-phosphate coating on medical titanium alloy Ti-6Al-4V (3.5-5.3% V; 5.3-6.8% Al; balance -Ti) by plasma electrolytic oxidation (PEO) has been developed. Evaluation of osteogenerating properties of the coating at fractures of the shaft of the femur on Wistar line laboratory r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161608

    authors: Gnedenkov SV,Sinebryukhov SL,Puz AV,Egorkin VS,Kostiv RE

    更新日期:2016-01-01 00:00:00

  • A simple two dimensional culture method to study the hypertrophic differentiation of rat articular chondrocytes.

    abstract:OBJECTIVES:Chondrocytes hypertrophy is a physiological process observed in endochondral ossification during development until adolescence in human. It can also be observed during pathophysiological conditions such as osteoarthritis. Hypertrophic chondrocytes synthesise collagen X and express matrix metalloproteinase 13...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141252

    authors: Filip A,Bianchi A,Mainard D,Lacolley P,Magdalou J,Mercier N

    更新日期:2015-01-01 00:00:00

  • Cultured blood versus donated blood: long-run perspectives of the economy of blood.

    abstract::Recent advances of fundamental research on the in vitro generation of red blood cells (RBCs) from hematopoietic stem cells in the laboratory open new possibilities of the utilization of cultured RBCs in transfusion medicine. We study the economic challenge of the setup and development of the mass industrial production...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141251

    authors: Mercier Ythier J

    更新日期:2015-01-01 00:00:00

  • A novel approach for arrhythmia diagnosis: Self-adaptive and distribution-free mode.

    abstract::Arrhythmia diagnosis is very significant to ensure human health. In this paper, a new model is developed for arrhythmia diagnosis. A salient feature of the algorithm is a synergistic combination of statistical and fuzzy set-based techniques. It is distribution-free and is realized in an unsupervised mode. Arrhythmia d...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151400

    authors: Li F,Zheng D,Zhao T

    更新日期:2015-01-01 00:00:00

  • Nonholonomic mobile system control by combining EEG-based BCI with ANFIS.

    abstract::Motor imagery EEG-based BCI has advantages in the assistance of human control of peripheral devices, such as the mobile robot or wheelchair, because the subject is not exposed to any stimulation and suffers no risk of fatigue. However, the intensive training necessary to recognize the numerous classes of data makes it...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151409

    authors: Yu W,Feng H,Feng Y,Madani K,Sabourin C

    更新日期:2015-01-01 00:00:00

  • Computer-aided detection of lung nodules using outer surface features.

    abstract::In this study, a computer-aided detection (CAD) system was developed for the detection of lung nodules in computed tomography images. The CAD system consists of four phases, including two-dimensional and three-dimensional preprocessing phases. In the feature extraction phase, four different groups of features are extr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151418

    authors: Demir Ö,Yılmaz Çamurcu A

    更新日期:2015-01-01 00:00:00

  • Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    abstract::Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151427

    authors: Zhang Y,Gao Y,Li H,Teng Y,Kang Y

    更新日期:2015-01-01 00:00:00

  • Sparse-view computed tomography image reconstruction via a combination of L(1) and SL(0) regularization.

    abstract::Low-dose computed tomography reconstruction is an important issue in the medical imaging domain. Sparse-view has been widely studied as a potential strategy. Compressed sensing (CS) method has shown great potential to reconstruct high-quality CT images from sparse-view projection data. Nonetheless, low-contrast struct...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151437

    authors: Qi H,Chen Z,Guo J,Zhou L

    更新日期:2015-01-01 00:00:00

203 条记录 1/6 页 « 123456 »