4D model of hemodynamics in the abdominal aorta.

Abstract:

:The paper presents an application of the FSI technique to determine hemodynamics in the abdominal aorta (AA). To establish boundary conditions for the FSI study, MR anatomical data and 4D MRI velocity-mapping data (in three blood flow velocity directions and time) were collected to acquire realistic geometry of the AA and blood velocity. The mechanical parameters of the patient-specific aortic wall were applied in FSI simulations to describe wall mechanics and blood flow in the AA. Comparison of calculated and measured blood flow patterns and flow rate waveforms shows good agreement, which proves that wall pulsations should be incorporated into simulations that determine hemodynamics in the AA. The results of this work suggest that FSI analysis based on patient-specific data, such as the mechanical parameters of the aortic wall, real geometry of the aorta, and 4D flow information, might be used to predict the development of cardiovascular diseases.

journal_name

Biomed Mater Eng

authors

Zbicinski I,Veshkina N,Stefańczyk L

doi

10.3233/BME-151312

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

S257-64

eissn

0959-2989

issn

1878-3619

pii

BME1312

journal_volume

26 Suppl 1

pub_type

杂志文章
  • Characterization of biomedical polymer surface interaction with human factor Xa.

    abstract::Two surface analytical spectroscopic techniques (namely, angular-dependent X-ray photoelectron spectroscopy and static secondary ion mass spectrometry) were used to characterize the nature and composition of the surface and near-surface layers formed on three biomedical polymers (namely, low-density polyethylene, expa...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G,Newman J,Katz W

    更新日期:1995-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Sterilization of auto-crosslinked hyaluronic acid scaffolds structured in microparticles and sponges.

    abstract::This work evaluated the effects of UV irradiation, plasma radiation, steam and 70% ethanol treatments on the sterilization and integrity of auto-crosslinked hyaluronic acid (HA-ACP) scaffolds structured in microparticles and sponges aiming in vivo applications for regenerative medicine of bone tissue. The integrity of...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151558

    authors: Shimojo AA,de Souza Brissac IC,Pina LM,Lambert CS,Santana MH

    更新日期:2015-01-01 00:00:00

  • Carbonate hydroxyapatite gel monolith formation and drying.

    abstract::The effect of carbonate in reducing the crystal size of precipitated hydroxyapatite by approximately an order of magnitude has not been used previously in the preparation of gel monoliths for the fabrication of carbonate hydroxyapatite ceramics. The aim of this study was to devise a method whereby gel monoliths of car...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Barralet JE,Best SM,Bonfield W

    更新日期:1996-01-01 00:00:00

  • Effect of surface roughness on the initial response of MC3T3-E1 cells cultured on polished titanium alloy.

    abstract::Surface roughness has been considered as an important influencing factor for cell response. The aim of this study was to find out whether MC3T3-E1 cells, a mouse osteoblast-like cell line, can sense the amplitudes of surface topography of titanium alloy (Ti6Al4V), and if surface-dependent cell morphology would be pres...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151301

    authors: Wu C,Chen M,Zheng T,Yang X

    更新日期:2015-01-01 00:00:00

  • In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): feasibility and reproducibility.

    abstract:OBJECTIVES:to assess reliability and reproducibility of quantitative MRI (7 T) in assessing rat femoro-tibial cartilage volume. METHODS:5 healthy rat knees were scanned in vivo using a 7 T experimental imager. Sagittal high resolution 3D Gradient Echo with fat suppression sequences were performed with a dedicated home...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Goebel JC,Bolbos R,Pinzano A,Schaeffer M,Rengle A,Galois L,Etienne S,Netter P,Loeuille D,Beuf O,Gillet P

    更新日期:2008-01-01 00:00:00

  • Optimal subband Kalman filter for normal and oesophageal speech enhancement.

    abstract::This paper presents the single channel speech enhancement system using subband Kalman filtering by estimating optimal Autoregressive (AR) coefficients and variance for speech and noise, using Weighted Linear Prediction (WLP) and Noise Weighting Function (NWF). The system is applied for normal and Oesophageal speech si...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141183

    authors: Ishaq R,García Zapirain B

    更新日期:2014-01-01 00:00:00

  • The pulse wave analysis of normal pregnancy: investigating the gestational effects on photoplethysmographic signals.

    abstract:OBJECTIVE:Normal pregnancy is associated with profound alterations in the maternal cardiovascular system and PPG represents a sensitive and convenient technique capable of tracking changes in the pulsatile function of arteries. The aim of this study was to investigate the effects of maternal cardiovascular alterations ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130801

    authors: Su F,Li Z,Sun X,Han N,Wang L,Luo X

    更新日期:2014-01-01 00:00:00

  • Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130811

    authors: Yu CH,Piao YJ,Kim K,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

    abstract::In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zaki M,Aljinaidi A,Hamed M

    更新日期:2003-01-01 00:00:00

  • Deterioration in the superelasticity of Ti sputter coated on NiTi orthodontic wire.

    abstract::To evaluate the deterioration in the superelasticity of Ti-coated NiTi orthodontic wires, titanium was coated onto wires to form a 1-microm thick film using radio frequency magnetron sputtering. In superelasticity cycle tests, the sigma5.0 value (the stress at 5.0% strain) of a Ti-coated wire was lower than that of a ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Asaoka T,Daisaku T,Fukui Y

    更新日期:2003-01-01 00:00:00

  • Injectable CMC/PEI gel as an in vivo scaffold for demineralized bone matrix.

    abstract::A number of materials have been considered as sources of grafts to repair bone defects. Here, we examined the possibility of creating in situ-forming gels from sodium carboxymethylcellulose (CMC) and poly(ethyleneimine) (PEI) for use as an in vivo carrier of demineralized bone matrix (DBM). The interaction between ani...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0603

    authors: Kim KS,Kang YM,Lee JY,Kim ES,Kim CH,Min BH,Lee HB,Kim JH,Kim MS

    更新日期:2009-01-01 00:00:00

  • A novel approach for arrhythmia diagnosis: Self-adaptive and distribution-free mode.

    abstract::Arrhythmia diagnosis is very significant to ensure human health. In this paper, a new model is developed for arrhythmia diagnosis. A salient feature of the algorithm is a synergistic combination of statistical and fuzzy set-based techniques. It is distribution-free and is realized in an unsupervised mode. Arrhythmia d...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151400

    authors: Li F,Zheng D,Zhao T

    更新日期:2015-01-01 00:00:00

  • The effect of counter-ions on the ion selectivity of potassium and sodium ions in nanopores.

    abstract::The ion selective transport plays an important role in the function of cell membranes, and promotes the application of artificial permeable membranes. This phenomenon has been studied in case for different diameters and functional groups of nanopores. In this work, we focus on the effect of anions on cation selectivit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130822

    authors: Tang D,Kim D

    更新日期:2014-01-01 00:00:00

  • A new method to accurately assess post-laser-surgery refractive changes with the intrinsic corneal power changes.

    abstract::To evaluate the ability of assessing the refractive change induced by myopic laser surgery using the intrinsic data, obtained from a reference intrinsic to the cornea. Twenty-nine eyes with laser in situ keratomileusis for myopia were included in the study. Statistical analyses were performed to determine the relation...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-151374

    authors: Liu Y,Wang Z,Wang Y

    更新日期:2015-01-01 00:00:00

  • Design of a quasi-passive 3 DOFs ankle-foot wearable rehabilitation orthosis.

    abstract::Muscular rigidity and atrophy caused by long-term underactivity usually lead to foot drop, strephenopodia, foot extorsion or some other complications for the lower limb movement disorders or lower limb surgery sufferers. The ankle-foot orthosis can help patients conduct the right ankle motion mode training, inhibit sp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151356

    authors: Zhang C,Zhu Y,Fan J,Zhao J,Yu H

    更新日期:2015-01-01 00:00:00

  • Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    abstract::Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151427

    authors: Zhang Y,Gao Y,Li H,Teng Y,Kang Y

    更新日期:2015-01-01 00:00:00

  • Experimental exploration of mouse kidney imaging with the SR PCI technology.

    abstract::This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value of kidney imaging with phase contrast imaging technology. In our experiment, spatial resolution and tissue contrast serve as element evaluation and comparison....

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130917

    authors: Xia C,Peng YF,Arun KY,Xiao T,Zhu P,He W

    更新日期:2014-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.

    abstract::Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141023

    authors: Wang F,Mohammed A,Li C,Ge P,Wang L,King MW

    更新日期:2014-01-01 00:00:00

  • Hollow calcium phosphate microcarriers for bone regeneration: in vitro osteoproduction and ex vivo mechanical assessment.

    abstract::Synthetic grafting materials, such as calcium phosphates (hydroxyapatite, HA; tricalcium phosphate, TCP), polymers, or composites thereof, can be used as osteoconductive scaffolds and delivery vehicles for osteoinductive growth factors. Carrier materials must be engineered to deliver these factors in a controlled fash...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Santoni BG,Pluhar GE,Motta T,Wheeler DL

    更新日期:2007-01-01 00:00:00

  • SAR and thermal response effects of a two-arm Archimedean spiral coil in a magnetic induction sensor on a human head.

    abstract::This study investigates the radiation safety of a newly designed magnetic induction sensor. This novel magnetic induction sensor uses a two-arm Archimedean spiral coil (TAASC) as the exciter. A human head model with a real anatomical structure was used to calculate the specific absorption rate (SAR) and temperature ch...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151329

    authors: Zhang Z,Liu P,Zhou D,Zhang L,Ding L

    更新日期:2015-01-01 00:00:00

  • Multiple platelet-rich plasma preparations can solubilize freeze-dried chitosan formulations to form injectable implants for orthopedic indications.

    abstract:BACKGROUND:Platelet-rich plasma (PRP) has been used to solubilize freeze-dried chitosan (CS) formulations to form injectable implants for tissue repair. OBJECTIVE:To determine whether the in vitro performance of the formulations depends on the type of PRP preparation used to solubilize CS. METHODS:Formulations contai...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191058

    authors: Ghazi Zadeh L,Chevrier A,Lamontagne M,Buschmann MD,Hoemann CD,Lavertu M

    更新日期:2019-01-01 00:00:00

  • Nonholonomic mobile system control by combining EEG-based BCI with ANFIS.

    abstract::Motor imagery EEG-based BCI has advantages in the assistance of human control of peripheral devices, such as the mobile robot or wheelchair, because the subject is not exposed to any stimulation and suffers no risk of fatigue. However, the intensive training necessary to recognize the numerous classes of data makes it...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151409

    authors: Yu W,Feng H,Feng Y,Madani K,Sabourin C

    更新日期:2015-01-01 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Mechanical loading characteristics of total hip prosthetics subjected to dynamic loading cycles.

    abstract::The selection of best material pair in the hip prosthetics design for improved performance and life relies on the estimation of hip joint contact stresses and contact pressure distribution during various dynamic loading cycles: Climbing Upstairs, Climbing downstairs and Knee bending. The maximum Von Mises stress, cont...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181019

    authors: Kalayarasan M,Shankar S,Manikandan M,Adithan K

    更新日期:2018-01-01 00:00:00

  • Characterization and human osteoblastic proliferation- and differentiation-stimulatory effects of phosphatidylcholine liposomes-encapsulated propranolol hydrochloride.

    abstract::DMPC and DSPC liposomes were prepared via thin film hydration method followed by sonication. Propranolol solution was incorporated into liposomes at hydration stage. TEM images showed the sizes of DSPC and DMPC were around 88 and 137 nm, respectively. The highest encapsulation ratio of propranolol was approximately 70...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140997

    authors: Teong B,Kuo SM,Chen CH,Chen YK,Cheng ZJ,Huang HH

    更新日期:2014-01-01 00:00:00

  • Bone regeneration from human mesenchymal stem cells on porous hydroxyapatite-PLGA-collagen bioactive polymer scaffolds.

    abstract::We have developed a novel multicomponent nano-hydroxyapatite-poly(D,L-lactide-co-glycolide)-collagen biomaterial (nHAP-PLGA-collagen) with mechanical properties similar to human cancellous bone. To demonstrate the bone forming capacity of nHAP-PLGA-collagen prior to in vivo experiments, nHAP-PLGA-collagen films and 3D...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171703

    authors: Bhuiyan DB,Middleton JC,Tannenbaum R,Wick TM

    更新日期:2017-01-01 00:00:00

  • A viscoelastic material model to represent smooth muscle shortening.

    abstract::The mechanical properties of a contracting smooth muscle can be changed by changing its length. A viscoelastic material model was developed to predict the length-dependent stiffness changes when a constrained muscle is allowed to shorten under a constant external force. Three-dimensional finite element simulations wer...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Pidaparti RM,Liu Y,Meiss RA

    更新日期:1997-01-01 00:00:00

  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00