Abstract:
:Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipulation or the use of bioreactors to improve their performance. In this study, we focused on the concept of in situ cellularization and developed a tissue-engineered vascular graft with degradable/non-degradable polymer composites for arterial reconstruction that would facilitate the renewal of autologous tissue without any pretreatment. Additionally, these composites are designed to improve the mechanical performance of a small-diameter vascular prosthesis scaffold that is made from a flexible membrane of poly(e-caprolactone) (PCL). The PCL scaffold was reinforced by embedding a tubular fabric that was knitted from polyethylene terephthalate (PET) yarns within the freeze-dried composite structure. Adding this knitted fabric component significantly improved the mechanical properties of the composite scaffold, such as its tensile strength and initial modulus, radial compliance, compression recovery, and suture retention force. Finally, this reinforced composite structure is a promising candidate for use as a tissue-engineered scaffold for a future small diameter vascular prosthesis.
journal_name
Biomed Mater Engjournal_title
Bio-medical materials and engineeringauthors
Wang F,Mohammed A,Li C,Ge P,Wang L,King MWdoi
10.3233/BME-141023subject
Has Abstractpub_date
2014-01-01 00:00:00pages
2127-33issue
6eissn
0959-2989issn
1878-3619pii
R41785715N581W45journal_volume
24pub_type
杂志文章abstract::The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat ecce...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-181737
更新日期:2018-01-01 00:00:00
abstract::Polycrystalline diamond (PCD) exhibits excellent abrasive characteristics and is commonly used as loose grains for precision machining of hard ceramics and other materials that are difficult to grind and polish. In the present study, we investigated using bonded PCD for polishing dental porcelain, for which a lustrous...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2010-0642
更新日期:2010-01-01 00:00:00
abstract::The effect of hydroxyapatite sol (HAm) which is composed of unheating hydroxyapatite microcrystal particle on cell proliferation and alkaline phophatase activity in osteoblastic MC3T3-E1 cells, was examined in the presence or absence of fetal calfe serum (FCS) in the medium. In the absence of FCS, HAm inhibited the ce...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract::Robotized endoscope holder in laparoscopic surgeries allows surgeons to control the endoscope without the assistants' intervention. In this paper, a new method is proposed for the automatic 3D-tracking of laparoscopic instruments in real-time to provide more convenient interactions between surgeons and the robotized e...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-141083
更新日期:2014-01-01 00:00:00
abstract:BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out qu...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-181034
更新日期:2019-01-01 00:00:00
abstract::This paper presents an X-ray diffraction method of measuring the residual stress/strain in bone tissue of rabbit's tibia. To derive the residual stress, bone powder of the diameter less than 40 micrometers was used as a control specimen at non-stressed state. From the X-ray measurements, it was clear that the distribu...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2006-01-01 00:00:00
abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1997-01-01 00:00:00
abstract:BACKGROUND:Scallop shell powder is called bioshell calcium oxide (BiSCaO), which is known to possess deodorizing properties and broad antimicrobial activity against various pathogenic microbes, including viruses, bacteria, spores, and fungi. OBJECTIVE:This study aims to investigate the applications of BiSCaO suspensio...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-201082
更新日期:2020-01-01 00:00:00
abstract::The fretting corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium ball-and-socket-joint with tetrafluoroethylene under mechanical load. ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2003-01-01 00:00:00
abstract::We previously reported a simple method for the preparation of size-controlled spherical silver nanoparticles (Ag NPs) generated by autoclaving a mixture of silver-containing glass powder and glucose. The particle size is regulated by the glucose concentration, with concentrations of 0.25, 1.0 and 4.0 wt% glucose provi...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130772
更新日期:2013-01-01 00:00:00
abstract:BACKGROUND:The most common cause of coronary artery disease (CAD) is vascular damage with the cholesterol built-up and other materials on the inner arterial wall, known as atherosclerosis. OBJECTIVE:This paper aims to investigate the effect of stenosis on the hemodynamics in the four suspected coronary artery disease ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-191067
更新日期:2019-01-01 00:00:00
abstract::In this study, biocompatibility of 17-4 PH stainless steel foam for biomedical implant applications was investigated. 17-4 PH stainless steel foams having porosities in the range of 40-82% with an average pore size of around 600 μm were produced by space holder-sintering technique. Sintered foams were precipitation ha...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2011-0671
更新日期:2011-01-01 00:00:00
abstract::Intraocular lenses (IOL) made of polymethyl methacrylate (PMMA) lack an important yellowish pigment useful as a filter in the visual process and in the protection of the retina from short wavelength light. It was found that the PMMA used for IOL manufacturing can be tinted by dry exposure to mercury near-UV emitting l...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1991-01-01 00:00:00
abstract::The interactions between carbon nanotubes and important biomolecules, above all collagen molecules, have not been studied in detail. This situation is partly due to the fact that CNT are solid entities, while most of the biomolecules can be prepared in solution. We used turbidity as a means of evaluating the interacti...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2009-0557
更新日期:2009-01-01 00:00:00
abstract::Skilled behavior is difficult or impossible to articulate explicitly by the performers. Likewise biomechanical models of skilled motor actions are often limited by the lack of knowledge of the underlying mechanisms. A 'behavioral cloning' technique is described, based on a trained artificial neural network (ANN), that...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1998-01-01 00:00:00
abstract::Some computer applications for cell characterization in medicine and biology, such as analysis of surface structure of cell wall-deficient EVC (El Tor Vibrio of Cholera), operate with cell samples taken from very small areas of interest. In order to perform texture characterization in such an application, only a few t...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2001-01-01 00:00:00
abstract::Longitudinal stent compression (LSC) is a new failure mode not previously observed in coronary stents. This phenomenon occurs when the physician tries to cross the deployed stent with other devices. While this phenomenon has been observed with a number of stent designs, it seems more common with the Element stent. A c...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130781
更新日期:2014-01-01 00:00:00
abstract::The objective of the present study was to find a standard substance for use as a reference in the cytotoxicity assay of biomaterials, as an alternative to animal experiments in recent years. Eight kinds of rubber were made in a plate shape to keep their surface area at 1 cm2 against 10 ml of extract volume. They were ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::Based upon previous research on the relation between hip prosthesis designs and strain distributions in a proximal femur model, a prototype of a "physiological" hip prosthesis was designed and manufactured. Strain gauge measurements on a dry femur before and after implantation of this prosthesis were made in different...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1993-04-01 00:00:00
abstract::The values of the propagation coefficient measured on a silicon rubber tube in the frequency range 1-15 Hz were compared, using four different equations. The first formula is based on three simultaneous pressure measurements performed at equidistant points; the remaining three equations are original, and make use of o...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1992-10-01 00:00:00
abstract::Electroencephalograph (EEG) signals feature extraction and processing is one of the most difficult and important part in the brain-computer interface (BCI) research field. EEG signals are generally unstable, complex and have low signal-noise ratio, which is difficult to be analyzed and processed. To solve this problem...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-141113
更新日期:2014-01-01 00:00:00
abstract::A potassium-doped synthetic apatite was prepared by soaking hydroxyapatite in potassium carbonate and potassium chloride solutions. The hydroxyapatite was prepared by firing slip cast ceramic bodies in vacuum at 1100 degrees C. The conical ceramic samples and a crushed material of this were soaked in carbonate and chl...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::To obtain an appropriate model for the simulation of the biomechanical behavior of brain tissue and the deformation of ventricles, in particular, we have developed a novel computerized plain strain finite element model. For optimum results, a multiple loading solutions approach using various tissue parameters for the ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2007-01-01 00:00:00
abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130907
更新日期:2014-01-01 00:00:00
abstract::Modeling of thermal-induced mechanical behaviors of soft tissues is of great importance for thermal ablation. This paper presents a method by integrating the heating process with thermal-induced mechanical deformations of soft tissues for simulation and analysis of the thermal ablation process. This method combines bi...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-141043
更新日期:2014-01-01 00:00:00
abstract::Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems assoc...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2012-0678
更新日期:2011-01-01 00:00:00
abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1999-01-01 00:00:00
abstract::The hip stem design based upon X-ray films requires sufficient information in order to customize for the patient. If the errors are resulted from rotating angles, more X-ray films may carry out the solution. The present study aimed to realize the improvement of multiple X-ray films for hip stem design. Eight X-ray fil...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00