Simultaneous quantitative analysis of indomethacin and benzoic acid in gel using ultra-violet-visible spectrophotometry and chemometrics.

Abstract:

BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out quantitative analysis of indomethacin (IMC) and benzoic acid (BA) in the gel during pharmaceutical manufacturing process. METHODS:The gel preparations contained 0.1-1.5% IMC, 0.015-0.225% BA, 2% carbopol® 941 and 95% ethanol solution. The calibration models were constructed using the partial least square regression (PLS). RESULTS:The relationships of the measured and predicted concentrations for both IMC and BA had linear plots. The developed PLS calibration models were used to monitor the IMC and BA concentrations during mixing of the gels by the planetary centrifugal and conventional mixers, respectively. IMC and BA were gradually dispersed, dissolved and completely homogeneous within 30 min by the centrifugal mixer. In contrast, IMC and BA were slowly dispersed, dissolved and completely homogeneous at more than 60 min by the conventional mixer. CONCLUSIONS:The ultra-violet-visible spectrophotometric method couples with multivariate chemometric techniques for quantitative data analysis were successfully applied for the simultaneous determination of major component IMC and trace component BA in the gel.

journal_name

Biomed Mater Eng

authors

Peerapattana J,Hattori Y,Otsuka M

doi

10.3233/BME-181034

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

73-84

issue

1

eissn

0959-2989

issn

1878-3619

pii

BME181034

journal_volume

30

pub_type

杂志文章
  • A comparison study on the flexural strength and compressive strength of four resin-modified luting glass ionomer cements.

    abstract::The purpose of this study is to compare the differences in flexural strength and compressive strength between four resin-modified luting glass ionomer cements that are commonly used in clinics. Furthermore, this study investigates the influence of curing mode on the flexural strength and compressive strength of dual-c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151284

    authors: Li Y,Lin H,Zheng G,Zhang X,Xu Y

    更新日期:2015-01-01 00:00:00

  • Electrochemical behaviour of a cobalt-chromium-molybdenum dental alloy in artificial salivas: Influence of phosphate ions and mucin components.

    abstract::The stability of the Co-Cr-Mo dental alloy immersed in artificial salivas (pH 6.7) was investigated over 24 h. Three artificial salivas have been studied: saline saliva (saliva I); saline saliva buffered with phosphate ions (saliva II) and saliva II plus mucin molecules (saliva III). For all the systems, open circuit ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141241

    authors: de Aguiar SR,Nicolai M,Almeida M,Gomes A

    更新日期:2015-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Development of asymmetric stent for treatment of eccentric plaque.

    abstract::The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat ecce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181737

    authors: Syaifudin A,Takeda R,Sasaki K

    更新日期:2018-01-01 00:00:00

  • Cellular compatibility of highly degradable bioactive ceramics for coating of metal implants.

    abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0678

    authors: Radetzki F,Wohlrab D,Zeh A,Delank KS,Mendel T,Berger G,Syrowatka F,Mayr O,Bernstein A

    更新日期:2011-01-01 00:00:00

  • Design of a quasi-passive 3 DOFs ankle-foot wearable rehabilitation orthosis.

    abstract::Muscular rigidity and atrophy caused by long-term underactivity usually lead to foot drop, strephenopodia, foot extorsion or some other complications for the lower limb movement disorders or lower limb surgery sufferers. The ankle-foot orthosis can help patients conduct the right ankle motion mode training, inhibit sp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151356

    authors: Zhang C,Zhu Y,Fan J,Zhao J,Yu H

    更新日期:2015-01-01 00:00:00

  • Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

    abstract::In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zaki M,Aljinaidi A,Hamed M

    更新日期:2003-01-01 00:00:00

  • Mechanical behavior of quartz fiber reinforced epoxy resins for teeth restoration.

    abstract::In this work composite materials, based on quartz fibers and epoxy resins, were employed with the aim to restore damaged teeth. The composite materials were chosen because they show biomechanical features very similar to that of the dentine, the main constituent of the tooth. Extracted teeth were rebuilt with two diff...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Visco AM,Calabrese L,Campo N,Torrisi L,Oteri G,Lo Giudice G,Cicciù D

    更新日期:2006-01-01 00:00:00

  • Tight medial knot tying may increase retearing risk after transosseous equivalent repair of rotator cuff tendon.

    abstract:BACKGROUND:Retearing mechanism after transosseous equivalent (TOE) rotator cuff repair has not been fully clarified yet. OBJECTIVE:The purposes of this study were to compare the stress distribution pattern in the tendon stump between knotted and knotless TOE repair and to investigate the role of suture tension applied...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171673

    authors: Sano H,Tokunaga M,Noguchi M,Inawashiro T,Irie T,Abe H,Yokobori AT

    更新日期:2017-01-01 00:00:00

  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • Experimal study of young male drivers' responses to vehicle collision using EMG of lower extremity.

    abstract::A driver's response to a front-coming vehicle collision consists of braking reaction time and braking behavior. The purpose was to investigate drivers' responses at different speeds, relative distances, and particularly the behavior on the accelerator at the collision moment. Twelve young men participated in driving s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151347

    authors: Gao Z,Li C,Hu H,Zhao H,Chen C,Yu H

    更新日期:2015-01-01 00:00:00

  • Use of enzyme-linked immunosorbent assay (ELISA) for detection and quantification of monoclonal antibodies.

    abstract::The thrust of the present work is the demonstration of the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of a monoclonal antibody human serum. The antibodies used, 7E3 and D3GP3, have been proposed as platelet receptor blockers, being directed specifically again...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G

    更新日期:1994-01-01 00:00:00

  • Effect of calcium alginate concentration on viability and proliferation of encapsulated fibroblasts.

    abstract::Alginate hydrogels have been used widely in tissue engineering for cell encapsulation for several reasons: low toxicity, the ability to gel under gentle condition and compatibility with cells. In this study, we determined the effect of different concentrations of alginate on encapsulation of 3T3 fibroblast cells at tw...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0665

    authors: Bohari SP,Hukins DW,Grover LM

    更新日期:2011-01-01 00:00:00

  • Fracture behavior of dental composite resins.

    abstract::Fracture toughness (KIC), critical stress intensity factor, and bending strength of 3 types of commercially available dental composite resins (macrofilled, hybrid and microfilled type) were determined using three point bend specimens. Acoustic Emission (AE), which is the generation of elastic wave due to the release o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Kim KH,Park JH,Imai Y,Kishi T

    更新日期:1991-01-01 00:00:00

  • Solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC) -- structural investigations on two different carrier systems.

    abstract::Two different types of colloidal lipid particles are presented and compared as innovative carrier systems. Size distribution and storage stability of formulations produced by hot high pressure homogenisation in lab and medium scale production were investigated by laser diffractometry (LD) and photon correlation spectr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Saupe A,Wissing SA,Lenk A,Schmidt C,Müller RH

    更新日期:2005-01-01 00:00:00

  • A novel diagnostic system for Doppler ultrasound of the peripheral arteries to detect the presence of thoracic aortic aneurysm.

    abstract:OBJECTIVE:We aimed to develop a novel ultrasound system and examine its feasibility for noninvasively detecting thoracic aortic aneurysm (TAA) in clinical settings. METHODS:We developed a novel ultrasound system consisting of a modified console and data analysis algorithm. The exploratory study included 100 patients h...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191047

    authors: Hayatsu Y,Watanabe K,Sasaki K,Masaki N,Katahira S,Kumagai K,Kawamoto S,Ohmi T,Yokobori AT Jr,Saiki Y

    更新日期:2019-01-01 00:00:00

  • Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.

    abstract:BACKGROUND:Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. OBJECTIVE:To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompat...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161607

    authors: Nalbantgil D,Ulkur F,Kardas G,Culha M

    更新日期:2016-11-25 00:00:00

  • A novel model for biomechanical behavior of human brain in epidural hematoma injuries.

    abstract::To obtain an appropriate model for the simulation of the biomechanical behavior of brain tissue and the deformation of ventricles, in particular, we have developed a novel computerized plain strain finite element model. For optimum results, a multiple loading solutions approach using various tissue parameters for the ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Farmanzad F,Najarian S,Eslamee MR,Seddighi AS

    更新日期:2007-01-01 00:00:00

  • Crystal chemistry of hydroxyapatite deposited on titanium by sputtering technique.

    abstract::Crystalline hydroxyapatite (HA) powder was coated on titanium substrate by radio frequency (RF) magnetron sputtering. The coating was homogeneous thin film and the thickness was 1microm. Crystallinity of the HA coating was low and Ca/P ratio was high as 3.0. Particle sizes were 40 to approximately 100 nm, and the crys...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Nishimura I,Fukui Y

    更新日期:2000-01-01 00:00:00

  • Individual tooth region segmentation using modified watershed algorithm with morphological characteristic.

    abstract::In this paper, a new method for individual tooth segmentation was proposed. The proposed method is composed of enhancement and extraction of boundary and seed of watershed algorithm using trisection areas by morphological characteristic of teeth. The watershed algorithm is one of the conventional methods for tooth seg...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141153

    authors: Na SD,Lee G,Lee JH,Kim MN

    更新日期:2014-01-01 00:00:00

  • Hyaluronic acid as an internal phase additive to obtain ofloxacin/PLGA microsphere by double emulsion method.

    abstract::Hyaluronic acid (HA) was used as an internal phase additive to improve the loading efficiency of ofloxacin, a hydrophilic drug encapsulated by hydrophobic polylactic-co-glycolic acid (PLGA) materials, through a double emulsion (water-in-oil-in-water) solvent extraction/evaporation method. Results from laser distributi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130863

    authors: Wu G,Chen L,Li H,Wang YJ

    更新日期:2014-01-01 00:00:00

  • Different effects of nanophase and conventional hydroxyapatite thin films on attachment, proliferation and osteogenic differentiation of bone marrow derived mesenchymal stem cells.

    abstract:UNLABELLED:It is suggested that nanophase hydroxyapatite (nHAP) might have advantages over conventional hydroxyapatite (cHAP) as a biomaterial for bone regeneration. To be a satisfactory candidate for bone tissue engineering, it is important to support the growth and differentiation of bone marrow-derived mesenchymal s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zhou GS,Su ZY,Cai YR,Liu YK,Dai LC,Tang RK,Zhang M

    更新日期:2007-01-01 00:00:00

  • The influence of Zn on the deposition of HA on sol-gel derived bioactive glass.

    abstract::To evaluate the influence of Zn on the formation of hydroxyapatite (HA), zinc-containing glass 58S4Z was prepared by substitution of CaO with 4 wt% ZnO in 58S bioactive glass, and Zn-containing simulated body fluid (ZnSBF) was prepared as soaking fluid. During the soaking, all samples could induce the deposition of HA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du RL,Chang J

    更新日期:2006-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • Analysis of the effects of different materials in a tooth implant-supported fixed prosthesis using finite element method.

    abstract::In this study, design optimization of a tooth implant-supported fixed prosthesis was investigated theoretically. A three-dimensional finite element analysis was utilized to simulate the stress distribution and deformation, with an emphasis on the material selection for various parts of the prosthesis. This mandibular ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dargahi J,Najarian S,Talebi M

    更新日期:2005-01-01 00:00:00

  • An improved finite element modeling of the cerebrospinal fluid layer in the head impact analysis.

    abstract::The finite element (FE) method has been widely used to investigate the mechanism of traumatic brain injuries (TBIs), because it is technically difficult to quantify the responses of the brain tissues to the impact in experiments. One of technical challenges to build a FE model of a human head is the modeling of the ce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171666

    authors: Wu JZ,Pan CS,Wimer BM,Rosen CL

    更新日期:2017-01-01 00:00:00

  • Thermomechanical analysis of shape memory devices.

    abstract::Shape memory alloys (SMA) are being increasingly used in various industrial applications as actuators, connectors, or damping materials. In the medical field, superelastic devices such as eyeglass frames, stents or guide catheters have come to market in the recent years. The design of SMA devices has usually been base...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Trochu F,Brailovski V,Meunier MA,Terriault P,Qian YY

    更新日期:1996-01-01 00:00:00

  • Microencapsulated rBMMSCs/calcium phosphate cement for bone formation in vivo.

    abstract::As an injectable scaffold material for bone tissue engineering, calcium phosphate cement (CPC) has good biocompatibility, self-setting, and osteoconduction properties. Alginate-microencapsulated seed cells can pick up the degradation speed and bioactivity of CPC. The aim of this study was to explore the osteogenic abi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130875

    authors: Wang J,Qiao P,Dong L,Li F,Xu T,Xie Q

    更新日期:2014-01-01 00:00:00

  • A method to visualize transdermal nickel permeation in mouse skin using a nickel allergy patch.

    abstract::Metal patch test is often used in clinical settings when metal-induced contact dermatitis is suspected. However, the transdermal permeation behavior of metal ions from the patch test remains unclear. Current patch tests using high concentrations of metal salt solutions have some side effects, e.g. acute skin reactions...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151543

    authors: Sugiyama T,Uo M,Wada T,Hongo T,Omagari D,Komiyama K,Oikawa M,Kusama M,Mori Y

    更新日期:2015-01-01 00:00:00

  • Degradability in vitro of polyurethanes based on synthetic atactic poly[(R,S)-3-hydroxybutyrate].

    abstract::The aim of the present study was to determine the degradability of aliphatic polyurethanes, based on a different amount of synthetic, atactic poly[(R,S)-3-hydroxybutyrate] (a-PHB), in hydrolytic (phosphate buffer) and oxidative (H2O2/CoCl2) solutions. The soft segments were built with atactic poly[(R,S)-3-hydroxybutyr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151262

    authors: Brzeska J,Janeczek H,Janik H,Kowalczuk M,Rutkowska M

    更新日期:2015-01-01 00:00:00