A novel model for biomechanical behavior of human brain in epidural hematoma injuries.

Abstract:

:To obtain an appropriate model for the simulation of the biomechanical behavior of brain tissue and the deformation of ventricles, in particular, we have developed a novel computerized plain strain finite element model. For optimum results, a multiple loading solutions approach using various tissue parameters for the simulation of epidural hematoma have been tested. For this purpose, CT-Scan of a patient with traumatic epidural hematoma has been modeled. By changing the tissue parameters (E and nu) and increasing intraventricular pressure gradient, the displacement of similar points in the modeled ventricle was compared with the true values obtained from patient's CT-Scan taken 3 months later after the resolution of hematoma. The magnitudes leading to least errors were determined. Best solutions were obtained with E=11-12 kPa and DeltaP=1.25-1.5 kPa (7.5-9.4 mmHg), which were consistent with the patient's clinical condition. Biomechanical modeling of unilateral displacement loadings, which are the conditions similar to surgical navigation systems, without considering ventricular geometry and their internal pressure resulted in unacceptable results.

journal_name

Biomed Mater Eng

authors

Farmanzad F,Najarian S,Eslamee MR,Seddighi AS

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

119-25

issue

2

eissn

0959-2989

issn

1878-3619

journal_volume

17

pub_type

杂志文章
  • An experimental study on the biomechanical properties of the cancellous bones of distal femur.

    abstract:OBJECTIVE:To study the comprehensive biomechanical properties of the cancellous bone of distal femur through a series of mechanical tests, and provide relevant subjects with the basic technical data. BACKGROUND:The study on bone mechanics is a commonly used approach to evaluate the biomechanical competency of bone. Th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du C,Ma H,Ruo M,Zhang Z,Yu X,Zeng Y

    更新日期:2006-01-01 00:00:00

  • Counter-propagation network with variable degree variable step size LMS for single switch typing recognition.

    abstract::Morse code is now being harnessed for use in rehabilitation applications of augmentative-alternative communication and assistive technology, including mobility, environmental control and adapted worksite access. In this paper, Morse code is selected as a communication adaptive device for disabled persons who suffer fr...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:

    authors: Yang CH,Luo CH,Yang CH,Chuang LY

    更新日期:2004-01-01 00:00:00

  • The fracture toughness characteristics of three dental composite resins.

    abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

    更新日期:1991-01-01 00:00:00

  • The mechanical-chemical attachment between the artificial articular cartilage (PVA-hydrogel) and metal substrate (or underlying bone).

    abstract::PVA-hydrogel has excellent biocompatibility as well as preferable tribological characteristics as an artificial articular cartilage. One of the most difficult problems is the attachment of PVA-hydrogel to the underlying bone (or metal substrate). In the present study, the micro-mechanical attachment between the PVA-hy...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gu ZQ,Xiao JM,Lou SQ

    更新日期:1999-01-01 00:00:00

  • Residual stress in bone structure and tissue of rabbit's tibiofibula.

    abstract::This paper presents an X-ray diffraction method of measuring the residual stress/strain in bone tissue of rabbit's tibia. To derive the residual stress, bone powder of the diameter less than 40 micrometers was used as a control specimen at non-stressed state. From the X-ray measurements, it was clear that the distribu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Tadano S,Okoshi T

    更新日期:2006-01-01 00:00:00

  • In vitro evaluation of a multifunctional nano drug delivery system based on tigecycline-loaded calcium-phosphate/ poly-DL-lactide-co-glycolide.

    abstract::Most drug delivery systems as treatment modalities for osteomyelitis have not been evaluated for resistant infections. Tigecycline (TG) is an antimicrobial agent that could be used in the treatment of multi-drug-resistant orthopedic infections. The objective of this in vitro study has been to determine what dosage of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140978

    authors: Ignjatović NL,Ninkov P,Sabetrasekh R,Lyngstadaas SP,Uskoković DP

    更新日期:2014-01-01 00:00:00

  • Medpor regulates osteoblast's microRNAs.

    abstract::Porous polyethylene (PP or Medpor) is an alloplastic material worldwide used for craniofacial reconstruction. Although several clinical studies are available, there is a lack as regard the genetic effects. Because PP is always fixed on bone and the mechanism by which PP acts on osteoblasts is unknown, we therefore att...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Palmieri A,Pezzetti F,Brunelli G,Martinelli M,Scapoli L,Arlotti M,Masiero E,Carinci F

    更新日期:2008-01-01 00:00:00

  • Optically-guided scalpel with light-scattering module for carpal tunnel surgical procedure via minimally invasive surgery.

    abstract::A novel technique and product for carpal tunnel microscopic surgical procedures using a modified medical device containing a head as a surgical scalpel under light guidance were designed and studied. The novel design of the medical device was developed and applied in a new carpal tunnel microscopic surgical procedure ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151303

    authors: Chiang MC,Huang CC

    更新日期:2015-01-01 00:00:00

  • Enhanced oral bioavailability and antiasthmatic efficacy of curcumin using redispersible dry emulsion.

    abstract::Dry emulsion containing curcumin (DE-CUR) was prepared for oral delivery of poorly water-soluble curcumin, and its oral bioavailability and antiasthmatic efficacy was evaluated. After comparison of the solubility of curcumin in various oils, Plurol® Oleique CC497 was selected to be the oil phase due to its higher solu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130886

    authors: Jang DJ,Kim ST,Oh E,Lee K

    更新日期:2014-01-01 00:00:00

  • Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130811

    authors: Yu CH,Piao YJ,Kim K,Kwon TK

    更新日期:2014-01-01 00:00:00

  • A study of quality control method for IMRT planning based on prior knowledge and novel measures derived from both OVHs and DVHs.

    abstract::Intensity-Modulated Radiation Therapy (IMRT) mathematically forms a large-scale optimization problem. The development of an IMRT plan is computationally expensive resulting in time-consuming, inefficient, and difficult to develop high-quality IMRT plans. By combining prior knowledge with proposed novel measures derive...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141173

    authors: Zhou Z,Chen Y,Yu Z,Wang D,Zhao C,Xu J,Song W,Li B,Shen J,Zhu X

    更新日期:2014-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • Predicting the minimal inhibitory concentration of fluoroquinolones for Escherichia coli using an accumulation model.

    abstract::The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the "Fick-Nernst-Planck" equatio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141203

    authors: Zhang W,Wang C,Tam KY

    更新日期:2014-01-01 00:00:00

  • Mouse coronary angiography in vivo using synchrotron radiation.

    abstract:PURPOSE:To establish a method for mouse coronary angiography in vivo using synchrotron radiation, which is essential for physiological and pathological research on coronary diseases. METHODS:1) The imaging parameters (e.g., photon energy, spatial resolution of the detector, and injection rate of contrast agent) optima...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130937

    authors: Xu L,Zhang A,Du G,Xie H,Chen Y

    更新日期:2014-01-01 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Experimal study of young male drivers' responses to vehicle collision using EMG of lower extremity.

    abstract::A driver's response to a front-coming vehicle collision consists of braking reaction time and braking behavior. The purpose was to investigate drivers' responses at different speeds, relative distances, and particularly the behavior on the accelerator at the collision moment. Twelve young men participated in driving s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151347

    authors: Gao Z,Li C,Hu H,Zhao H,Chen C,Yu H

    更新日期:2015-01-01 00:00:00

  • Ultrasonic study of processed milk cream and vegetable oils.

    abstract::Food systems are complex and inhomogeneous in nature. Ultrasonic propagation velocity in the food systems, in this case processed milk cream and vegetable oils, is studied. Ultrasonic properties of the food systems are similar to those of complex biological tissues. The presence of vegetable oil as an adulterant in th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Singh VR,Kumar A

    更新日期:1992-04-01 00:00:00

  • Analysis of the effects of different materials in a tooth implant-supported fixed prosthesis using finite element method.

    abstract::In this study, design optimization of a tooth implant-supported fixed prosthesis was investigated theoretically. A three-dimensional finite element analysis was utilized to simulate the stress distribution and deformation, with an emphasis on the material selection for various parts of the prosthesis. This mandibular ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dargahi J,Najarian S,Talebi M

    更新日期:2005-01-01 00:00:00

  • Influence of modified alginate hydrogels on mesenchymal stem cells and olfactory bulb-derived glial cells cultures.

    abstract:BACKGROUND:Great potential of cellular therapies has generated extensive research in the field of cells harvesting and culturing. Transplantation of cell cultures has been used in a variety of therapeutic programs but in many cases it appeared that biomaterial scaffold or sheath would enhance cells regenerative potenti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140966

    authors: Marycz K,Szarek D,Grzesiak J,Wrzeszcz K

    更新日期:2014-01-01 00:00:00

  • Predicting a DNA-binding protein using random forest with multiple mathematical features.

    abstract::DNA-binding proteins are involved and play a crucial role in a lot of important biological processes. Hence, the identification of the DNA-binding proteins is a challenging and significant problem. In order to reveal the intrinsic information correlated to DNA-binding, nine classes of candidate features based on diffe...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151491

    authors: Guan C,Niu X,Shi F,Yang K,Li N

    更新日期:2015-01-01 00:00:00

  • Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.

    abstract::Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141023

    authors: Wang F,Mohammed A,Li C,Ge P,Wang L,King MW

    更新日期:2014-01-01 00:00:00

  • A simple two dimensional culture method to study the hypertrophic differentiation of rat articular chondrocytes.

    abstract:OBJECTIVES:Chondrocytes hypertrophy is a physiological process observed in endochondral ossification during development until adolescence in human. It can also be observed during pathophysiological conditions such as osteoarthritis. Hypertrophic chondrocytes synthesise collagen X and express matrix metalloproteinase 13...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141252

    authors: Filip A,Bianchi A,Mainard D,Lacolley P,Magdalou J,Mercier N

    更新日期:2015-01-01 00:00:00

  • Sterilization of auto-crosslinked hyaluronic acid scaffolds structured in microparticles and sponges.

    abstract::This work evaluated the effects of UV irradiation, plasma radiation, steam and 70% ethanol treatments on the sterilization and integrity of auto-crosslinked hyaluronic acid (HA-ACP) scaffolds structured in microparticles and sponges aiming in vivo applications for regenerative medicine of bone tissue. The integrity of...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151558

    authors: Shimojo AA,de Souza Brissac IC,Pina LM,Lambert CS,Santana MH

    更新日期:2015-01-01 00:00:00

  • In vivo study of osteogenerating properties of calcium-phosphate coating on titanium alloy Ti-6Al-4V.

    abstract::The method of formation of bioactive calcium-phosphate coating on medical titanium alloy Ti-6Al-4V (3.5-5.3% V; 5.3-6.8% Al; balance -Ti) by plasma electrolytic oxidation (PEO) has been developed. Evaluation of osteogenerating properties of the coating at fractures of the shaft of the femur on Wistar line laboratory r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161608

    authors: Gnedenkov SV,Sinebryukhov SL,Puz AV,Egorkin VS,Kostiv RE

    更新日期:2016-01-01 00:00:00

  • Design of a quasi-passive 3 DOFs ankle-foot wearable rehabilitation orthosis.

    abstract::Muscular rigidity and atrophy caused by long-term underactivity usually lead to foot drop, strephenopodia, foot extorsion or some other complications for the lower limb movement disorders or lower limb surgery sufferers. The ankle-foot orthosis can help patients conduct the right ankle motion mode training, inhibit sp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151356

    authors: Zhang C,Zhu Y,Fan J,Zhao J,Yu H

    更新日期:2015-01-01 00:00:00

  • Multiphysics of bone remodeling: A 2D mesoscale activation simulation.

    abstract::In this work, we present an evolutive trabecular model for bone remodeling based on a boundary detection algorithm accounting for both biology and applied mechanical forces, known to be an important factor in bone evolution. A finite element (FE) numerical model using the Abaqus/Standard® software was used with a UMAT...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171636

    authors: Spingarn C,Wagner D,Rémond Y,George D

    更新日期:2017-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • Synthesis and enhanced bone regeneration of carbonate substituted octacalcium phosphate.

    abstract::Using a wet method, we have synthesized octacalcium phosphate carbonate, in which HPO42- in octacalcium phosphate is replaced with CO32-. The physical, crystal, and chemical properties of this new material were compared to octacalcium phosphate, Ca-deficient hydroxyapatite, and Ca-deficient carbonate apatite using X-r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171651

    authors: Shen D,Horiuchi N,Nozaki S,Miyashin M,Yamashita K,Nagai A

    更新日期:2017-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Self-adaptive image denoising based on bidimensional empirical mode decomposition (BEMD).

    abstract::To better analyze images with the Gaussian white noise, it is necessary to remove the noise before image processing. In this paper, we propose a self-adaptive image denoising method based on bidimensional empirical mode decomposition (BEMD). Firstly, normal probability plot confirms that 2D-IMF of Gaussian white noise...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141143

    authors: Guo S,Luan F,Song X,Li C

    更新日期:2014-01-01 00:00:00