Wave propagation in the silicon tube: comparison of the two-point and three-point pressure methods.

Abstract:

:The values of the propagation coefficient measured on a silicon rubber tube in the frequency range 1-15 Hz were compared, using four different equations. The first formula is based on three simultaneous pressure measurements performed at equidistant points; the remaining three equations are original, and make use of only two of the three pressure measurements together with a no-flow condition at the terminal tube section. The results of our trials demonstrate that the experimental phase velocity, obtained with all equations, settles at a value about 25% in excess of the theoretical one computed with a classic linear mathematical model. This result may be explained by an increase in the dynamical Young modulus with respect to that measured in static conditions. However, the three-point method introduces great errors in the results in the frequency range 11-14 Hz where the spectrum of the second signal becomes minimum. In all cases, the experimental value of attenuation per wavelength at mid-high frequencies is greater than the theoretical one valid for a purely elastic tube. The attenuation values obtained with the two-point method can be explained by introducing a small contribution of wall viscoelasticity (2-3 degrees) into the linear model. Attenuation per wavelength computed with the three-point methods turns out about threefold that computed with each of the two-point formulas. This result supports the idea that the accuracy of the three-point method may be insufficient to achieve correct estimation of wave attenuation, especially when the distance between transducers is small compared to wavelength.

journal_name

Biomed Mater Eng

authors

Ursino M,Artioli E

subject

Has Abstract

pub_date

1992-10-01 00:00:00

pages

155-69

issue

3

eissn

0959-2989

issn

1878-3619

journal_volume

2

pub_type

杂志文章
  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00

  • Short-term human chondrocyte culturing on oriented collagen coated gelatine scaffolds for cartilage replacement.

    abstract::The biological, biochemical, mechanical, and structural properties of artificial scaffolds for tissue engineering are known to be of great importance. Therefore, in this study a hydrogel derived scaffold with biomechanical and structural properties similar to native articular cartilage was synthesized. The gelatine-ba...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zehbe R,Libera J,Gross U,Schubert H

    更新日期:2005-01-01 00:00:00

  • Self-expanding stents in the treatment of carotid artery subtotal occlusion: a clinical study on the patients of Hubei and Sichuan in China.

    abstract::Stroke is a major cause of death and disability throughout the world. Subtotal occlusion of the carotid artery is an important risk factor for stroke. Carotid artery stenting (CAS) is increasingly being used for treatment of carotid artery stenosis. There are many reports on treating carotid artery stenosis by CAS; ho...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0687

    authors: Zhang C,Wang Z,Zheng H,Qiu Y,He X,Yang H,Liu W

    更新日期:2012-01-01 00:00:00

  • A method to visualize transdermal nickel permeation in mouse skin using a nickel allergy patch.

    abstract::Metal patch test is often used in clinical settings when metal-induced contact dermatitis is suspected. However, the transdermal permeation behavior of metal ions from the patch test remains unclear. Current patch tests using high concentrations of metal salt solutions have some side effects, e.g. acute skin reactions...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151543

    authors: Sugiyama T,Uo M,Wada T,Hongo T,Omagari D,Komiyama K,Oikawa M,Kusama M,Mori Y

    更新日期:2015-01-01 00:00:00

  • Does artificial aging correctly predict the long-term in-vivo degradation behavior in zirconia hip prostheses?

    abstract:BACKGROUND:Accelerated hydrothermal aging has long been one of the most widely accepted quality control tests for simulating low-temperature degradation (LTD) in zirconia-containing implants used in total hip arthroplasty (THA). However, it is still unclear how much consistency there is between the experimental predict...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201083

    authors: Tateiwa T,Takahashi Y,Pezzotti G,Shishido T,Masaoka T,Sano K,Yamamoto K

    更新日期:2020-01-01 00:00:00

  • Sterilization of auto-crosslinked hyaluronic acid scaffolds structured in microparticles and sponges.

    abstract::This work evaluated the effects of UV irradiation, plasma radiation, steam and 70% ethanol treatments on the sterilization and integrity of auto-crosslinked hyaluronic acid (HA-ACP) scaffolds structured in microparticles and sponges aiming in vivo applications for regenerative medicine of bone tissue. The integrity of...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151558

    authors: Shimojo AA,de Souza Brissac IC,Pina LM,Lambert CS,Santana MH

    更新日期:2015-01-01 00:00:00

  • Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.

    abstract::Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141023

    authors: Wang F,Mohammed A,Li C,Ge P,Wang L,King MW

    更新日期:2014-01-01 00:00:00

  • Characterization of biomedical polymer surface interaction with human factor Xa.

    abstract::Two surface analytical spectroscopic techniques (namely, angular-dependent X-ray photoelectron spectroscopy and static secondary ion mass spectrometry) were used to characterize the nature and composition of the surface and near-surface layers formed on three biomedical polymers (namely, low-density polyethylene, expa...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G,Newman J,Katz W

    更新日期:1995-01-01 00:00:00

  • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.

    abstract::The debris generated by the progressive wear of total joint replacement (TJR) devices is considered a primary cause of osteolysis, bone resorption, and premature failure of artificial hips and knees. The vast majority of this debris originates from the UHMWPE articulating surfaces caused by tribological interaction wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Davidson JA,Poggie RA,Mishra AK

    更新日期:1994-01-01 00:00:00

  • Evaluation of chondrocytes expression embedded in thermoresponsive poly(amino acid)s with sol-gel transition.

    abstract::Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chueh SK,Tachibana Y,Uyama H,Kobayashi S,Tomita N

    更新日期:2007-01-01 00:00:00

  • Characterization and human osteoblastic proliferation- and differentiation-stimulatory effects of phosphatidylcholine liposomes-encapsulated propranolol hydrochloride.

    abstract::DMPC and DSPC liposomes were prepared via thin film hydration method followed by sonication. Propranolol solution was incorporated into liposomes at hydration stage. TEM images showed the sizes of DSPC and DMPC were around 88 and 137 nm, respectively. The highest encapsulation ratio of propranolol was approximately 70...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140997

    authors: Teong B,Kuo SM,Chen CH,Chen YK,Cheng ZJ,Huang HH

    更新日期:2014-01-01 00:00:00

  • Inorganic phosphate (Pi) modulates the expression of key regulatory proteins of the inorganic pyrophosphate (PPi) metabolism in TGF-β1-stimulated chondrocytes.

    abstract::The balance between extracellular inorganic phosphate (ePi) and extracellular inorganic pyrophosphate (ePPi) is controlled by four membrane proteins: the transporters ANK (exporting PPi outside the cells) and PiT-1 (importing ePi into the cells), and the enzymes PC-1 (generating ePPi from nucleotides) and Tissue Non-s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0634

    authors: Hamade T,Bianchi A,Sebillaud S,Netter P,Jouzeau JY,Cailotto F

    更新日期:2010-01-01 00:00:00

  • Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

    abstract::In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zaki M,Aljinaidi A,Hamed M

    更新日期:2003-01-01 00:00:00

  • Ultrathin polymer monolayers for promotion of cell growth on bioprosthetic materials -- evolution of a new concept to improve long term performance of biologic heart vales.

    abstract::Reoperation of aldehyde tanned bioprotheses due to calcific degeneration remains their major drawback. Based on experiments studying mechanisms and factors that influence the time phase, extent and progression of calcification and evaluating the efficiency of anticalcification treatments and the effects of surface see...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dahm M,Rühe J,Berchthold B,Prüfer D,Prucker O,Chang BJ,Wallrath A,Oelert H

    更新日期:2004-01-01 00:00:00

  • Material removal during the sliding of hydroxyapatite against UHMWPE.

    abstract::Hydroxyapatite has been rubbed against ultra-high-molecular-weight-polyethylene (UHMWPE) under calcium-containg aqueous solutions. Further, hardness tests were carried out in air and in calcium-containing solutions whose pH ranged from pH 5 to pH 9. Hardness was found to vary with pH with a peak at around pH 7, i.e. -...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Mazeau G,Czernuszka JT

    更新日期:2001-01-01 00:00:00

  • Automatic quantitative analysis of bipolysaccharide liposome by image processing method.

    abstract::This paper established the extracting method and algorithm for liposome images on the basis of analyzing the form feature of liposome, and its corresponding automatic analysis software. Some algorithms, such as the logical algorithms of mathematical morphology, the grayscale-gradient co-occurrence matrix-based method ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Haitao X,Kuanghu H,Wanfang S,Shuyu L,Desen S

    更新日期:2002-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • Biodegradable/biocompatible coated metal implants for orthopedic applications.

    abstract::Biocompatible metals have been suggested as revolutionary biomaterials for bone-grafting therapies. Although metals and their alloys are widely and successfully used in producing biomedical implants due to their good mechanical properties and corrosion resistance, they have a lack in bioactivity. Therefore coating of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-161568

    authors: Saleh MM,Touny AH,Al-Omair MA,Saleh MM

    更新日期:2016-05-12 00:00:00

  • Mouse coronary angiography in vivo using synchrotron radiation.

    abstract:PURPOSE:To establish a method for mouse coronary angiography in vivo using synchrotron radiation, which is essential for physiological and pathological research on coronary diseases. METHODS:1) The imaging parameters (e.g., photon energy, spatial resolution of the detector, and injection rate of contrast agent) optima...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130937

    authors: Xu L,Zhang A,Du G,Xie H,Chen Y

    更新日期:2014-01-01 00:00:00

  • Accelerating sino-atrium computer simulations with graphic processing units.

    abstract::Sino-atrial node cells (SANCs) play a significant role in rhythmic firing. To investigate their role in arrhythmia and interactions with the atrium, computer simulations based on cellular dynamic mathematical models are generally used. However, the large-scale computation usually makes research difficult, given the li...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151365

    authors: Zhang H,Xiao Z,Lin SF

    更新日期:2015-01-01 00:00:00

  • Optically-guided scalpel with light-scattering module for carpal tunnel surgical procedure via minimally invasive surgery.

    abstract::A novel technique and product for carpal tunnel microscopic surgical procedures using a modified medical device containing a head as a surgical scalpel under light guidance were designed and studied. The novel design of the medical device was developed and applied in a new carpal tunnel microscopic surgical procedure ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151303

    authors: Chiang MC,Huang CC

    更新日期:2015-01-01 00:00:00

  • The pulse wave analysis of normal pregnancy: investigating the gestational effects on photoplethysmographic signals.

    abstract:OBJECTIVE:Normal pregnancy is associated with profound alterations in the maternal cardiovascular system and PPG represents a sensitive and convenient technique capable of tracking changes in the pulsatile function of arteries. The aim of this study was to investigate the effects of maternal cardiovascular alterations ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130801

    authors: Su F,Li Z,Sun X,Han N,Wang L,Luo X

    更新日期:2014-01-01 00:00:00

  • Use of enzyme-linked immunosorbent assay (ELISA) for detection and quantification of monoclonal antibodies.

    abstract::The thrust of the present work is the demonstration of the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of a monoclonal antibody human serum. The antibodies used, 7E3 and D3GP3, have been proposed as platelet receptor blockers, being directed specifically again...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G

    更新日期:1994-01-01 00:00:00

  • Cultured blood versus donated blood: long-run perspectives of the economy of blood.

    abstract::Recent advances of fundamental research on the in vitro generation of red blood cells (RBCs) from hematopoietic stem cells in the laboratory open new possibilities of the utilization of cultured RBCs in transfusion medicine. We study the economic challenge of the setup and development of the mass industrial production...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141251

    authors: Mercier Ythier J

    更新日期:2015-01-01 00:00:00

  • Effect of calcium alginate concentration on viability and proliferation of encapsulated fibroblasts.

    abstract::Alginate hydrogels have been used widely in tissue engineering for cell encapsulation for several reasons: low toxicity, the ability to gel under gentle condition and compatibility with cells. In this study, we determined the effect of different concentrations of alginate on encapsulation of 3T3 fibroblast cells at tw...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0665

    authors: Bohari SP,Hukins DW,Grover LM

    更新日期:2011-01-01 00:00:00

  • The dynein-triggered ciliary motion in embryonic nodes: an exploratory study based on computational models.

    abstract::The cilia, presenting a rotational movement in the embryonic nodes, play a crucial role in the left-right specification during embryogenesis. The characteristic architecture of these cilia is based on a cylindrical arrangement of 9 doublet microtubules and the motion of the cilia is triggered by the dynein motors loca...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141063

    authors: Chen D,Zhong Y,Shinohara K,Nishida T,Hasegawa T,Hamada H

    更新日期:2014-01-01 00:00:00

  • Synthesis and enhanced bone regeneration of carbonate substituted octacalcium phosphate.

    abstract::Using a wet method, we have synthesized octacalcium phosphate carbonate, in which HPO42- in octacalcium phosphate is replaced with CO32-. The physical, crystal, and chemical properties of this new material were compared to octacalcium phosphate, Ca-deficient hydroxyapatite, and Ca-deficient carbonate apatite using X-r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171651

    authors: Shen D,Horiuchi N,Nozaki S,Miyashin M,Yamashita K,Nagai A

    更新日期:2017-01-01 00:00:00

  • Fracture behavior of dental composite resins.

    abstract::Fracture toughness (KIC), critical stress intensity factor, and bending strength of 3 types of commercially available dental composite resins (macrofilled, hybrid and microfilled type) were determined using three point bend specimens. Acoustic Emission (AE), which is the generation of elastic wave due to the release o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Kim KH,Park JH,Imai Y,Kishi T

    更新日期:1991-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00

  • Sparse-view computed tomography image reconstruction via a combination of L(1) and SL(0) regularization.

    abstract::Low-dose computed tomography reconstruction is an important issue in the medical imaging domain. Sparse-view has been widely studied as a potential strategy. Compressed sensing (CS) method has shown great potential to reconstruct high-quality CT images from sparse-view projection data. Nonetheless, low-contrast struct...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151437

    authors: Qi H,Chen Z,Guo J,Zhou L

    更新日期:2015-01-01 00:00:00