Evaluation of chondrocytes expression embedded in thermoresponsive poly(amino acid)s with sol-gel transition.

Abstract:

:Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydrogel with encapsulated cells at physiological body temperature. Chondrocytes were isolated from joint of 4-week-old Japanese white rabbits, dispersed within the thermoresponsive polymer solution and maintained for up to 72 hours in vitro. The polymer solutions demonstrated concentration-dependent inhibitory effect on chondrocytes multiplication. After the three-day cultivation, the survival rate of the chondrocytes fell into a 70~90% ranges among all the tested polymer concentrations. The morphology studies showed that there were some physical and/or chemical stress leading cells to necrosis and some extent apoptosis. Some physical and/or chemical stress may be applied, and over 70% of the chondrocytes could survive through the stress, suggesting that some phenotype could have been selected from the heterogeneous mixture of chondrocytes.

journal_name

Biomed Mater Eng

authors

Chueh SK,Tachibana Y,Uyama H,Kobayashi S,Tomita N

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

137-46

issue

3

eissn

0959-2989

issn

1878-3619

journal_volume

17

pub_type

杂志文章
  • Application of polyethylene air-bubble cushions to improve the shock absorption performance of Type I construction helmets for repeated impacts.

    abstract:BACKGROUND:The use of helmets was considered to be one of the important prevention strategies employed on construction sites. The shock absorption performance of a construction (or industrial) helmet is its most important performance parameter. Industrial helmets will experience cumulative structural damage when being ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201132

    authors: Wu JZ,Pan CS,Ronaghi M,Wimer BM,Reischl U

    更新日期:2021-01-01 00:00:00

  • Contact stress at articular surfaces in total joint replacements. Part II: Analytical and numerical methods.

    abstract::In this second part of the series of reviews, attention focuses on analytical and numerical methods that have been used to estimate the magnitude of the contact stress in: models of articular joints; models of total joint replacements, without and with the associated joint; or models of simple physical systems that ar...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:

    authors: Lewis G

    更新日期:1998-01-01 00:00:00

  • SIFT algorithm-based 3D pose estimation of femur.

    abstract::To address the lack of 3D space information in the digital radiography of a patient femur, a pose estimation method based on 2D-3D rigid registration is proposed in this study. The method uses two digital radiography images to realize the preoperative 3D visualization of a fractured femur. Compared with the pure Digit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141103

    authors: Zhang X,Zhu Y,Li C,Zhao J,Li G

    更新日期:2014-01-01 00:00:00

  • Material removal during the sliding of hydroxyapatite against UHMWPE.

    abstract::Hydroxyapatite has been rubbed against ultra-high-molecular-weight-polyethylene (UHMWPE) under calcium-containg aqueous solutions. Further, hardness tests were carried out in air and in calcium-containing solutions whose pH ranged from pH 5 to pH 9. Hardness was found to vary with pH with a peak at around pH 7, i.e. -...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Mazeau G,Czernuszka JT

    更新日期:2001-01-01 00:00:00

  • Dentin bonding system. Part I: Literature review.

    abstract::Currently, clinicians face choices of restoration including amalgams (mercury-based, gallium-based alloys, or mercury-free silver-based substitutes), composite resins, ceramics, and gold alloy. In order to choose an appropriate restorative material, many parameters are involved; they include preparation time requireme...

    journal_title:Bio-medical materials and engineering

    pub_type: 历史文章,杂志文章,评审

    doi:

    authors: Miyazaki M,Oshida Y,Xirouchaki L

    更新日期:1996-01-01 00:00:00

  • Cellulose sponge as a scaffold for cartilage tissue engineering.

    abstract::One goal of functional tissue engineering is to manufacture scaffolds infiltrated with chondrocytes which are suitable for transplantation into the lesion areas of articular cartilage. Various research strategies are used to fabricate cartilage transplants which would have the correct phenotype, contain enough extrace...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Pulkkinen H,Tiitu V,Lammentausta E,Laasanen MS,Hämäläinen ER,Kiviranta I,Lammi MJ

    更新日期:2006-01-01 00:00:00

  • Simultaneous quantitative analysis of indomethacin and benzoic acid in gel using ultra-violet-visible spectrophotometry and chemometrics.

    abstract:BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out qu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181034

    authors: Peerapattana J,Hattori Y,Otsuka M

    更新日期:2019-01-01 00:00:00

  • Modelling the mechanical response of skin in vivo using the Bossinesq and the Michell stress functions.

    abstract::Local strains acting across an area of skin loaded uniaxially in vivo are converted to stresses using the standard elastic formulae. The stress values are compared to those obtained using the classical Bossinesq and Michell stress functions. The results indicate that these functions are capable of describing the respo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wan Abas WA,Asseli MR

    更新日期:1994-01-01 00:00:00

  • Chimerism analysis following nonmyeloablative stem cell transplantation using a new cell subset separation method: Robosep.

    abstract::Chimerism analysis has become an important tool to manage patients in the peri-transplant period of allogenic stem cell transplantation. During this period, cells of donor and host origin can coexist and increasing proportion of cells of host origin is considered as a recurrence of the underlying disease. We currently...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Decot V,Latger-Cannard V,Lecompte T,Clément L,Salmon A,Bordigoni P,Stoltz JF,Bensoussan D

    更新日期:2008-01-01 00:00:00

  • Influence of the hypothalamic paraventricular nucleus (PVN) on heart rate variability (HRV) in rat hearts via electronic lesion.

    abstract::Previous literatures have indicated that hypothalamic paraventricular nucleus (PVN) neurons are important for regulating the level of sympathetic and vagal nervous activity. Sympathovagal balance is closely related to heart rate variability (HRV). However, it still requires further elucidation regarding the effect of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151338

    authors: Deng X,Feng X,Li S,Gao Y,Yu B,Li G

    更新日期:2015-01-01 00:00:00

  • Adipose tissue regeneration in a 3D-printed poly(lactic acid) frame-supported space in the inguinal region of rats.

    abstract:BACKGROUND:Adipose tissue engineering has been studied as an alternative to current options for breast reconstruction, such as lipofilling, flap reconstruction, and silicone implants. Previously, we demonstrated that a poly(L-lactic acid) mesh containing a collagen sponge, containing neither cells nor growth factors, c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201103

    authors: Kambe Y,Ogino S,Yamanaka H,Morimoto N,Yamaoka T

    更新日期:2020-01-01 00:00:00

  • Development of asymmetric stent for treatment of eccentric plaque.

    abstract::The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat ecce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181737

    authors: Syaifudin A,Takeda R,Sasaki K

    更新日期:2018-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • New clinical failure mode triggered by a new coronary stent design.

    abstract::Longitudinal stent compression (LSC) is a new failure mode not previously observed in coronary stents. This phenomenon occurs when the physician tries to cross the deployed stent with other devices. While this phenomenon has been observed with a number of stent designs, it seems more common with the Element stent. A c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130781

    authors: Hsiao HM,Yeh CT,Chiu YH,Wang C,Chen CP

    更新日期:2014-01-01 00:00:00

  • Studies on quantitative analysis and automatic recognition of cell types of lung cancer.

    abstract::Recognition of lung cancer cells is very important to the clinical diagnosis of lung cancer. In this paper we present a novel method to extract the structure characteristics of lung cancer cells and automatically recognize their types. Firstly soft mathematical morphology methods are used to enhance the grayscale imag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chen YC,Hu KH,Li FZ,Li SY,Su WF,Huang ZY,Hu YX

    更新日期:2006-01-01 00:00:00

  • Real-time 3D visual tracking of laparoscopic instruments for robotized endoscope holder.

    abstract::Robotized endoscope holder in laparoscopic surgeries allows surgeons to control the endoscope without the assistants' intervention. In this paper, a new method is proposed for the automatic 3D-tracking of laparoscopic instruments in real-time to provide more convenient interactions between surgeons and the robotized e...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141083

    authors: Zhao Z

    更新日期:2014-01-01 00:00:00

  • Predicting the minimal inhibitory concentration of fluoroquinolones for Escherichia coli using an accumulation model.

    abstract::The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the "Fick-Nernst-Planck" equatio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141203

    authors: Zhang W,Wang C,Tam KY

    更新日期:2014-01-01 00:00:00

  • Interaction of collagen triple-helix with carbon nanotubes: Geometric property of rod-like molecules.

    abstract::The interactions between carbon nanotubes and important biomolecules, above all collagen molecules, have not been studied in detail. This situation is partly due to the fact that CNT are solid entities, while most of the biomolecules can be prepared in solution. We used turbidity as a means of evaluating the interacti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0557

    authors: Kuboki Y,Terada M,Kitagawa Y,Abe S,Uo M,Watari F

    更新日期:2009-01-01 00:00:00

  • Prevention of blood cell adhesion in porous inner wall of double-layered tube by saline perfusion.

    abstract::A double-layered tube consisting of a porous inner tube and a solid outer tube was used to perfuse isotonic saline solution into blood to prevent blood cell adhesion. Polystyrene/poly(styrene-co-butadiene) (PS-SBR) porous tubes were made using a dipping method. Citrated canine blood was circulated for 30 min with the ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Kim SS,Park JB

    更新日期:1993-07-01 00:00:00

  • Nonholonomic mobile system control by combining EEG-based BCI with ANFIS.

    abstract::Motor imagery EEG-based BCI has advantages in the assistance of human control of peripheral devices, such as the mobile robot or wheelchair, because the subject is not exposed to any stimulation and suffers no risk of fatigue. However, the intensive training necessary to recognize the numerous classes of data makes it...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151409

    authors: Yu W,Feng H,Feng Y,Madani K,Sabourin C

    更新日期:2015-01-01 00:00:00

  • Individual tooth region segmentation using modified watershed algorithm with morphological characteristic.

    abstract::In this paper, a new method for individual tooth segmentation was proposed. The proposed method is composed of enhancement and extraction of boundary and seed of watershed algorithm using trisection areas by morphological characteristic of teeth. The watershed algorithm is one of the conventional methods for tooth seg...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141153

    authors: Na SD,Lee G,Lee JH,Kim MN

    更新日期:2014-01-01 00:00:00

  • Push-out strength of hydroxyapatite coated by sputtering technique in bone.

    abstract::Hydroxyapatite was coated with 1 microm thickness on titanium columns of a length of 10 mm, an outer diameter of 4.0 mm by radio frequency magnetron sputtering. The hydroxyapatite coating titanium columns were implanted in the diaphysis of femora of 3 adult dogs, and push-out test was carried out after 2, 4 and 12 wee...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Nishimura I,Fukui Y

    更新日期:2001-01-01 00:00:00

  • Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130811

    authors: Yu CH,Piao YJ,Kim K,Kwon TK

    更新日期:2014-01-01 00:00:00

  • In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): feasibility and reproducibility.

    abstract:OBJECTIVES:to assess reliability and reproducibility of quantitative MRI (7 T) in assessing rat femoro-tibial cartilage volume. METHODS:5 healthy rat knees were scanned in vivo using a 7 T experimental imager. Sagittal high resolution 3D Gradient Echo with fat suppression sequences were performed with a dedicated home...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Goebel JC,Bolbos R,Pinzano A,Schaeffer M,Rengle A,Galois L,Etienne S,Netter P,Loeuille D,Beuf O,Gillet P

    更新日期:2008-01-01 00:00:00

  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • Assessment of the nanostructure of acid-base resistant zone by the application of all-in-one adhesive systems: Super dentin formation.

    abstract::An acid-base resistant zone (ABRZ) has been shown to be created under a hybrid layer in a self-etching adhesive system at the adhesive/dentin interface. The purpose of this study was to assess the nanostructure of the ABRZ by applying all-in-one adhesive systems. Human premolar dentin was treated with one of two all-i...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0576

    authors: Nikaido T,Weerasinghe DD,Waidyasekera K,Inoue G,Foxton RM,Tagami J

    更新日期:2009-01-01 00:00:00

  • Failed attempts and improvement strategies in peripheral intravenous catheterization.

    abstract:BACKGROUND:Access to peripheral veins is necessary for sample collection, transfusion and infusion of fluids or medications. The peripheral intravenous catheterization (PIVC) procedure is the introduction of a short catheter into a peripheral vein and can be problematic, leading to multiple failed attempts. PURPOSE:To...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-120735

    authors: Sabri A,Szalas J,Holmes KS,Labib L,Mussivand T

    更新日期:2013-01-01 00:00:00

  • SAR and thermal response effects of a two-arm Archimedean spiral coil in a magnetic induction sensor on a human head.

    abstract::This study investigates the radiation safety of a newly designed magnetic induction sensor. This novel magnetic induction sensor uses a two-arm Archimedean spiral coil (TAASC) as the exciter. A human head model with a real anatomical structure was used to calculate the specific absorption rate (SAR) and temperature ch...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151329

    authors: Zhang Z,Liu P,Zhou D,Zhang L,Ding L

    更新日期:2015-01-01 00:00:00

  • Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.

    abstract:BACKGROUND:Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. OBJECTIVE:To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompat...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161607

    authors: Nalbantgil D,Ulkur F,Kardas G,Culha M

    更新日期:2016-11-25 00:00:00

  • In vitro evaluation of a multifunctional nano drug delivery system based on tigecycline-loaded calcium-phosphate/ poly-DL-lactide-co-glycolide.

    abstract::Most drug delivery systems as treatment modalities for osteomyelitis have not been evaluated for resistant infections. Tigecycline (TG) is an antimicrobial agent that could be used in the treatment of multi-drug-resistant orthopedic infections. The objective of this in vitro study has been to determine what dosage of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140978

    authors: Ignjatović NL,Ninkov P,Sabetrasekh R,Lyngstadaas SP,Uskoković DP

    更新日期:2014-01-01 00:00:00