Prevention of blood cell adhesion in porous inner wall of double-layered tube by saline perfusion.

Abstract:

:A double-layered tube consisting of a porous inner tube and a solid outer tube was used to perfuse isotonic saline solution into blood to prevent blood cell adhesion. Polystyrene/poly(styrene-co-butadiene) (PS-SBR) porous tubes were made using a dipping method. Citrated canine blood was circulated for 30 min with the flow rate of 100 ml/min using an in vitro blood circulation setup which makes nonpulsatile blood flow. Blood cell adhesion in the PS/SBR porous tubes decreased with increased saline perfusion rate regardless of changes in variables such as tube porosities, tube materials, and perfusion materials. The relationship between blood cell adhesion and perfusion rate was semi-logarithmic. Blood cell adhesion was relatively high in the more porous tube (65% sugar tube), compared to the less porous tube (55% sugar tube) for an identical saline perfusion rate. The blood cell adhesion in the sulfonated PS/SBR porous tube was less than that in the nonsulfonated (control) PS/SBR porous tube. The blood cell adhesion was also decreased by citrate perfusion. The results of this study indicates that the saline perfusion method can be used to prevent blood cell adhesion in the blood lines of extracorporeal circulation systems (such as hemodialysis and heart-lung machines) if certain technical problems involving the surface roughness can be resolved.

journal_name

Biomed Mater Eng

authors

Kim SS,Park JB

subject

Has Abstract

pub_date

1993-07-01 00:00:00

pages

85-100

issue

2

eissn

0959-2989

issn

1878-3619

journal_volume

3

pub_type

杂志文章
  • Prediction model of sinoatrial node field potential using high order partial least squares.

    abstract::High order partial least squares (HOPLS) is a novel data processing method. It is highly suitable for building prediction model which has tensor input and output. The objective of this study is to build a prediction model of the relationship between sinoatrial node field potential and high glucose using HOPLS. The thr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151482

    authors: Feng Y,Cao H,Zhang Y

    更新日期:2015-01-01 00:00:00

  • Inorganic phosphate (Pi) modulates the expression of key regulatory proteins of the inorganic pyrophosphate (PPi) metabolism in TGF-β1-stimulated chondrocytes.

    abstract::The balance between extracellular inorganic phosphate (ePi) and extracellular inorganic pyrophosphate (ePPi) is controlled by four membrane proteins: the transporters ANK (exporting PPi outside the cells) and PiT-1 (importing ePi into the cells), and the enzymes PC-1 (generating ePPi from nucleotides) and Tissue Non-s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0634

    authors: Hamade T,Bianchi A,Sebillaud S,Netter P,Jouzeau JY,Cailotto F

    更新日期:2010-01-01 00:00:00

  • A new method to accurately assess post-laser-surgery refractive changes with the intrinsic corneal power changes.

    abstract::To evaluate the ability of assessing the refractive change induced by myopic laser surgery using the intrinsic data, obtained from a reference intrinsic to the cornea. Twenty-nine eyes with laser in situ keratomileusis for myopia were included in the study. Statistical analyses were performed to determine the relation...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-151374

    authors: Liu Y,Wang Z,Wang Y

    更新日期:2015-01-01 00:00:00

  • Titanium-porcelain system. Part I: Oxidation kinetics of nitrided pure titanium, simulated to porcelain firing process.

    abstract::The bonding strength of porcelains to metals depends on the oxide layer between the porcelain and the metal. Oxidation of a metal surface increases the bonding strength, whereas excessive oxidation decreases it. Titanium and its alloys are gaining acceptance for dental use since they exhibit excellent biocompatibility...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshida Y,Hashem A

    更新日期:1993-01-01 00:00:00

  • Enhanced oral bioavailability and antiasthmatic efficacy of curcumin using redispersible dry emulsion.

    abstract::Dry emulsion containing curcumin (DE-CUR) was prepared for oral delivery of poorly water-soluble curcumin, and its oral bioavailability and antiasthmatic efficacy was evaluated. After comparison of the solubility of curcumin in various oils, Plurol® Oleique CC497 was selected to be the oil phase due to its higher solu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130886

    authors: Jang DJ,Kim ST,Oh E,Lee K

    更新日期:2014-01-01 00:00:00

  • The effect of counter-ions on the ion selectivity of potassium and sodium ions in nanopores.

    abstract::The ion selective transport plays an important role in the function of cell membranes, and promotes the application of artificial permeable membranes. This phenomenon has been studied in case for different diameters and functional groups of nanopores. In this work, we focus on the effect of anions on cation selectivit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130822

    authors: Tang D,Kim D

    更新日期:2014-01-01 00:00:00

  • Biocompatibility of polysulfone II. Platelet adhesion and cho cell growth.

    abstract::Experimental results on the platelet adhesion, and CHO cell adhesion and growth onto nonionic surfactant which is composed of a long alkyl chain (n = 12-18) as the hydrophobic part, and a polyethyleneoxide (PEO) segment (n = 10-23) as the hydrophilic part coated and air-plasma treated PSf surfaces are presented in ter...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Khang G,Jeong BJ,Lee HB,Park JB

    更新日期:1995-01-01 00:00:00

  • Mechanical strength of sutured block copolymers films for load bearing medical applications.

    abstract::The mechanical behavior of three styrenic thermoplastic block copolymer elastomers with applied surgical sutures was studied by uniaxial tensile testing. The materials exhibited oriented cylindrical microstructure. Distinct macroscopic deformation mechanisms have been observed upon stretching of samples with vertical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130843

    authors: Stasiak J,Nair S,Moggridge GD

    更新日期:2014-01-01 00:00:00

  • An ensemble feature selection technique for cancer recognition.

    abstract::Correlation-based feature selection (CFS) using neighborhood mutual information (NMI) and particle swarm optimization (PSO) are combined into an ensemble technique in this paper. Based on this observation, an efficient gene selection algorithm, denoted by NMICFS-PSO, is proposed. Several cancer recognition tasks are g...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130897

    authors: Xu J,Sun L,Gao Y,Xu T

    更新日期:2014-01-01 00:00:00

  • Analysis of basal physical fitness and lumbar muscle function according to indoor horse riding exercise.

    abstract::The aim of this study is to verify the effect of indoor horse riding exercise on basal physical exercise and lumbar muscular function. The subjects included were 20 healthy females, who participated in the horse riding exercise using SRider (Rider Co. & ChonbuK National Univ, Korea) for 30 minutes per day, 3 days per ...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-141053

    authors: Yu CH,Hong CU,Kang SR,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Biological, biochemical and biomechanical characterisation of articular cartilage from the porcine, bovine and ovine hip and knee.

    abstract::This study aimed to determine the optimal starting material for the development of an acellular osteochondral graft. Osteochondral tissues from three different species were characterised; pig (6 months), cow (18 months) and two ages of sheep (8-12 months and >4 year old). Tissues from the acetabulum and femoral head o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151533

    authors: Fermor HL,McLure SW,Taylor SD,Russell SL,Williams S,Fisher J,Ingham E

    更新日期:2015-01-01 00:00:00

  • Automatic recognition of facial movement for paralyzed face.

    abstract::Facial nerve paralysis is a common disease due to nerve damage. Most approaches for evaluating the degree of facial paralysis rely on a set of different facial movements as commanded by doctors. Therefore, automatic recognition of the patterns of facial movement is fundamental to the evaluation of the degree of facial...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141093

    authors: Wang T,Dong J,Sun X,Zhang S,Wang S

    更新日期:2014-01-01 00:00:00

  • Medpor regulates osteoblast's microRNAs.

    abstract::Porous polyethylene (PP or Medpor) is an alloplastic material worldwide used for craniofacial reconstruction. Although several clinical studies are available, there is a lack as regard the genetic effects. Because PP is always fixed on bone and the mechanism by which PP acts on osteoblasts is unknown, we therefore att...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Palmieri A,Pezzetti F,Brunelli G,Martinelli M,Scapoli L,Arlotti M,Masiero E,Carinci F

    更新日期:2008-01-01 00:00:00

  • Effects of hydrogen sulfide on myocardial fibrosis in diabetic rats: Changes in matrix metalloproteinases parameters.

    abstract::In order to explore the effects of hydrogen sulfide (H2S) on myocardial fibrosis in diabetic rats and its underlying mechanisms, intraperitoneal injections of streptozotocin were used to establish the diabetes models and sodium hydrosulfide (NaHS) was used as an exogenous donor of H2S. Eight weeks later, Van Gieson st...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151508

    authors: Xiao T,Zeng O,Luo J,Wu Z,Li F,Yang J

    更新日期:2015-01-01 00:00:00

  • Rapid counting method of living cells by fluorescent enzyme substrates.

    abstract::The 5(and 6)-carboxyfluorescein diacetate (C-FDA) is used for a rapid and continuous counting of living cells. Nonfluorescent C-FDA is converted into fluorescent 5(and 6)-carboxyfluorescein (C-F) by the reaction with esterase, which is an enzyme of living cells. The conversion makes it possible to count the number of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sugata K,Ohnishi T,Matsumoto K

    更新日期:1991-01-01 00:00:00

  • Nonholonomic mobile system control by combining EEG-based BCI with ANFIS.

    abstract::Motor imagery EEG-based BCI has advantages in the assistance of human control of peripheral devices, such as the mobile robot or wheelchair, because the subject is not exposed to any stimulation and suffers no risk of fatigue. However, the intensive training necessary to recognize the numerous classes of data makes it...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151409

    authors: Yu W,Feng H,Feng Y,Madani K,Sabourin C

    更新日期:2015-01-01 00:00:00

  • Phosphorylated chitin increased bone formation when implanted into rat calvaria with the Ti-device.

    abstract:BACKGROUND:Previously we found that a group of phosphorylated proteins (SIBLINGs) in bone binds with the Ti-device, and increases the early bone formation around the Ti-implants remarkably. From these results, we explained the biochemical mechanism of a strong bond between living bone and Ti, which was discovered by Br...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201079

    authors: Song Q,Yagami K,Furusawa T,Takita H,Kurasaki M,Tokura S,Morimoto K,Sammons R,Iku S,Kuboki Y

    更新日期:2020-01-01 00:00:00

  • Effect of platelet-rich plasma on bone engineering with an alloplastic substitute containing BMP2.

    abstract::A robust method for inducing bone-formation without an autograft has not been established. Currently, both platelet-rich plasma (PRP) and bone morphogenetic protein (BMP) have been widely investigated for their clinical use in such cases. However, their synergistic effect is still controversial and previously shown di...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130741

    authors: Yoshida K,Sumita Y,Marukawa E,Harashima M,Asahina I

    更新日期:2013-01-01 00:00:00

  • Automatic quantitative analysis of bipolysaccharide liposome by image processing method.

    abstract::This paper established the extracting method and algorithm for liposome images on the basis of analyzing the form feature of liposome, and its corresponding automatic analysis software. Some algorithms, such as the logical algorithms of mathematical morphology, the grayscale-gradient co-occurrence matrix-based method ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Haitao X,Kuanghu H,Wanfang S,Shuyu L,Desen S

    更新日期:2002-01-01 00:00:00

  • Adipose tissue regeneration in a 3D-printed poly(lactic acid) frame-supported space in the inguinal region of rats.

    abstract:BACKGROUND:Adipose tissue engineering has been studied as an alternative to current options for breast reconstruction, such as lipofilling, flap reconstruction, and silicone implants. Previously, we demonstrated that a poly(L-lactic acid) mesh containing a collagen sponge, containing neither cells nor growth factors, c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201103

    authors: Kambe Y,Ogino S,Yamanaka H,Morimoto N,Yamaoka T

    更新日期:2020-01-01 00:00:00

  • Flow visualization in the outflow cannula of an axial blood pump.

    abstract::The properties of blood flow in the outflow cannula of an axial blood pump play a critical role in potential thrombus formation and vascular injury. In this study, an in vitro flow visualization technique using particle image velocimetry (PIV) was applied to investigate the flow characteristics in the outflow cannula ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130791

    authors: Liu G,Zhang Y,Chen H,Sun H,Zhou J,Hu S

    更新日期:2014-01-01 00:00:00

  • Development of SPR biosensor for simultaneous detection of multiplex respiratory viruses.

    abstract::A surface plasmon resonance (SPR)-based biosensor was developed for specific detection of nine common respiratory virus, including influenza A and influenza B, H1N1, respiratory syncytial virus (RSV), parainfluenza virus 1-3 (PIV1, 2, 3), adenovirus, and severe acute respiratory syndrome coronavirus (SARS). The SPR bi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151526

    authors: Shi L,Sun Q,He J,Xu H,Liu C,Zhao C,Xu Y,Wu C,Xiang J,Gu D,Long J,Lan H

    更新日期:2015-01-01 00:00:00

  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00

  • The development of a physiological hip prosthesis: evaluation of the strains after implantation of a prototype of hip implant: experiment in a dry femur.

    abstract::Based upon previous research on the relation between hip prosthesis designs and strain distributions in a proximal femur model, a prototype of a "physiological" hip prosthesis was designed and manufactured. Strain gauge measurements on a dry femur before and after implantation of this prosthesis were made in different...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Vander Sloten J,Labey L,Van Audekercke R,Van der Perre G

    更新日期:1993-04-01 00:00:00

  • In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): feasibility and reproducibility.

    abstract:OBJECTIVES:to assess reliability and reproducibility of quantitative MRI (7 T) in assessing rat femoro-tibial cartilage volume. METHODS:5 healthy rat knees were scanned in vivo using a 7 T experimental imager. Sagittal high resolution 3D Gradient Echo with fat suppression sequences were performed with a dedicated home...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Goebel JC,Bolbos R,Pinzano A,Schaeffer M,Rengle A,Galois L,Etienne S,Netter P,Loeuille D,Beuf O,Gillet P

    更新日期:2008-01-01 00:00:00

  • Residual stress in bone structure and tissue of rabbit's tibiofibula.

    abstract::This paper presents an X-ray diffraction method of measuring the residual stress/strain in bone tissue of rabbit's tibia. To derive the residual stress, bone powder of the diameter less than 40 micrometers was used as a control specimen at non-stressed state. From the X-ray measurements, it was clear that the distribu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Tadano S,Okoshi T

    更新日期:2006-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • Counter-propagation network with variable degree variable step size LMS for single switch typing recognition.

    abstract::Morse code is now being harnessed for use in rehabilitation applications of augmentative-alternative communication and assistive technology, including mobility, environmental control and adapted worksite access. In this paper, Morse code is selected as a communication adaptive device for disabled persons who suffer fr...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:

    authors: Yang CH,Luo CH,Yang CH,Chuang LY

    更新日期:2004-01-01 00:00:00

  • SAR and thermal response effects of a two-arm Archimedean spiral coil in a magnetic induction sensor on a human head.

    abstract::This study investigates the radiation safety of a newly designed magnetic induction sensor. This novel magnetic induction sensor uses a two-arm Archimedean spiral coil (TAASC) as the exciter. A human head model with a real anatomical structure was used to calculate the specific absorption rate (SAR) and temperature ch...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151329

    authors: Zhang Z,Liu P,Zhou D,Zhang L,Ding L

    更新日期:2015-01-01 00:00:00

  • Contact stress at articular surfaces in total joint replacements. Part II: Analytical and numerical methods.

    abstract::In this second part of the series of reviews, attention focuses on analytical and numerical methods that have been used to estimate the magnitude of the contact stress in: models of articular joints; models of total joint replacements, without and with the associated joint; or models of simple physical systems that ar...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:

    authors: Lewis G

    更新日期:1998-01-01 00:00:00