Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.

Abstract:

BACKGROUND:Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. OBJECTIVE:To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompatible and mechanically useful arch wire and mouthwash combination. METHODS:Each group comprised of 4 wire samples of 2 cm 0.016 × 0.022 inch. 1st group: ion implanted nickel titanium (INT), 2nd group: nickel titanium, without ion implantation (NT), 3rd group: micro layered esthetic nickel titanium (ENT), 4th group: stainless steel (SS) wires. They were immersed inside 2 ml of artificial saliva solutions (AS) for the control, or AS (9%) combined with 1 of the 3 mouthwashes (91%) for study groups, for 24 hours. These mouthwashes were essential oil (EO), chlorhexidine (CHX), sodium-fluoride (NaF). An electrochemical analyzer was used for electrochemical impedance spectroscopy measurements. RESULTS:High corrosion resistance was obtained for ENT than the other wires. The corrosion potentials are 0.007, -0.042, 0.074 and -0.015 V (Ag/AgCl) for ENT, INT, SS and NT in the artificial salivary, respectively. In NaF containing mouthwash Rp value of ENT is significantly high in comparison to others. The impedance responses of all materials increased significantly in the presence of NaF mouthwash as well as in the CHX mouthwash. Low frequencies are seen at all materials in EO mouthwash. Diameters of loops are 22, 5.9, 5.9 and 3.7 MΩ at ENT, INT, SS and NT. CONCLUSIONS:In this study, micro layered esthetic nickel titanium wires are found biocompatible among other wires and NaF and CHX mouthwashes can be recommend for their good corrosion resistance during fixed orthodontic therapy.

journal_name

Biomed Mater Eng

authors

Nalbantgil D,Ulkur F,Kardas G,Culha M

doi

10.3233/BME-161607

subject

Has Abstract

pub_date

2016-11-25 00:00:00

pages

539-549

issue

5

eissn

0959-2989

issn

1878-3619

pii

BME1607

journal_volume

27

pub_type

杂志文章
  • A new method to accurately assess post-laser-surgery refractive changes with the intrinsic corneal power changes.

    abstract::To evaluate the ability of assessing the refractive change induced by myopic laser surgery using the intrinsic data, obtained from a reference intrinsic to the cornea. Twenty-nine eyes with laser in situ keratomileusis for myopia were included in the study. Statistical analyses were performed to determine the relation...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-151374

    authors: Liu Y,Wang Z,Wang Y

    更新日期:2015-01-01 00:00:00

  • Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.

    abstract::Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141023

    authors: Wang F,Mohammed A,Li C,Ge P,Wang L,King MW

    更新日期:2014-01-01 00:00:00

  • Control of FES in paraplegia: modeling voluntary arm forces.

    abstract::Skilled behavior is difficult or impossible to articulate explicitly by the performers. Likewise biomechanical models of skilled motor actions are often limited by the lack of knowledge of the underlying mechanisms. A 'behavioral cloning' technique is described, based on a trained artificial neural network (ANN), that...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Andrews BJ,Davoodi R,Kamnik R,Bajd T

    更新日期:1998-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00

  • New clinical failure mode triggered by a new coronary stent design.

    abstract::Longitudinal stent compression (LSC) is a new failure mode not previously observed in coronary stents. This phenomenon occurs when the physician tries to cross the deployed stent with other devices. While this phenomenon has been observed with a number of stent designs, it seems more common with the Element stent. A c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130781

    authors: Hsiao HM,Yeh CT,Chiu YH,Wang C,Chen CP

    更新日期:2014-01-01 00:00:00

  • Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130811

    authors: Yu CH,Piao YJ,Kim K,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Cellular compatibility of highly degradable bioactive ceramics for coating of metal implants.

    abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0678

    authors: Radetzki F,Wohlrab D,Zeh A,Delank KS,Mendel T,Berger G,Syrowatka F,Mayr O,Bernstein A

    更新日期:2011-01-01 00:00:00

  • Rapid counting method of living cells by fluorescent enzyme substrates.

    abstract::The 5(and 6)-carboxyfluorescein diacetate (C-FDA) is used for a rapid and continuous counting of living cells. Nonfluorescent C-FDA is converted into fluorescent 5(and 6)-carboxyfluorescein (C-F) by the reaction with esterase, which is an enzyme of living cells. The conversion makes it possible to count the number of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sugata K,Ohnishi T,Matsumoto K

    更新日期:1991-01-01 00:00:00

  • Microencapsulated rBMMSCs/calcium phosphate cement for bone formation in vivo.

    abstract::As an injectable scaffold material for bone tissue engineering, calcium phosphate cement (CPC) has good biocompatibility, self-setting, and osteoconduction properties. Alginate-microencapsulated seed cells can pick up the degradation speed and bioactivity of CPC. The aim of this study was to explore the osteogenic abi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130875

    authors: Wang J,Qiao P,Dong L,Li F,Xu T,Xie Q

    更新日期:2014-01-01 00:00:00

  • The influence of Zn on the deposition of HA on sol-gel derived bioactive glass.

    abstract::To evaluate the influence of Zn on the formation of hydroxyapatite (HA), zinc-containing glass 58S4Z was prepared by substitution of CaO with 4 wt% ZnO in 58S bioactive glass, and Zn-containing simulated body fluid (ZnSBF) was prepared as soaking fluid. During the soaking, all samples could induce the deposition of HA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du RL,Chang J

    更新日期:2006-01-01 00:00:00

  • Selection of human p75NTR tag SNPs and its biological significance for clinical association studies.

    abstract::To select tag single nucleotide polymorphisms (SNPs) within and around human p75 neurotrophin receptor (p75NTR) gene in Chinese Han population, the sequence involving p75NTR gene as well as the upstream and downstream of the gene was identified according to the data from National Center for Biotechnology Information (...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141213

    authors: Wang YT,Lu XM,Shu YH,Xiao L,Chen KT

    更新日期:2014-01-01 00:00:00

  • A novel approach for arrhythmia diagnosis: Self-adaptive and distribution-free mode.

    abstract::Arrhythmia diagnosis is very significant to ensure human health. In this paper, a new model is developed for arrhythmia diagnosis. A salient feature of the algorithm is a synergistic combination of statistical and fuzzy set-based techniques. It is distribution-free and is realized in an unsupervised mode. Arrhythmia d...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151400

    authors: Li F,Zheng D,Zhao T

    更新日期:2015-01-01 00:00:00

  • Titanium-porcelain system. Part II: Bond strength of fired porcelain on nitrided pure titanium.

    abstract::Commercially pure titanium (CPT) substrate was subjected to porcelain firing and bond strengths under three-point bending mode (span length: 15 mm; crosshead speed: 0.5 mm/min) were evaluated. Experimental variables included surface treatments of CPT and porcelain firing schedules. Variables for the surface treatments...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshida Y,Fung LW,Isikbay SC

    更新日期:1997-01-01 00:00:00

  • Biocompatibility of 17-4 PH stainless steel foam for implant applications.

    abstract::In this study, biocompatibility of 17-4 PH stainless steel foam for biomedical implant applications was investigated. 17-4 PH stainless steel foams having porosities in the range of 40-82% with an average pore size of around 600 μm were produced by space holder-sintering technique. Sintered foams were precipitation ha...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0671

    authors: Mutlu I,Oktay E

    更新日期:2011-01-01 00:00:00

  • Counter-propagation network with variable degree variable step size LMS for single switch typing recognition.

    abstract::Morse code is now being harnessed for use in rehabilitation applications of augmentative-alternative communication and assistive technology, including mobility, environmental control and adapted worksite access. In this paper, Morse code is selected as a communication adaptive device for disabled persons who suffer fr...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:

    authors: Yang CH,Luo CH,Yang CH,Chuang LY

    更新日期:2004-01-01 00:00:00

  • Deterioration in the superelasticity of Ti sputter coated on NiTi orthodontic wire.

    abstract::To evaluate the deterioration in the superelasticity of Ti-coated NiTi orthodontic wires, titanium was coated onto wires to form a 1-microm thick film using radio frequency magnetron sputtering. In superelasticity cycle tests, the sigma5.0 value (the stress at 5.0% strain) of a Ti-coated wire was lower than that of a ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Asaoka T,Daisaku T,Fukui Y

    更新日期:2003-01-01 00:00:00

  • Effect of cancellous bone on the functionally graded dental implant concept.

    abstract::In a previous work by the author [H.S. Hedia and M. Nemat-Alla, Design optimization of functionally graded dental implant, submitted to be published in the J. Bio-Medical Materials and Engineering], a functionally graded material dental implant was designed without cansellous bone in the model. In this investigation t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Hedia HS

    更新日期:2005-01-01 00:00:00

  • Hyaluronic acid as an internal phase additive to obtain ofloxacin/PLGA microsphere by double emulsion method.

    abstract::Hyaluronic acid (HA) was used as an internal phase additive to improve the loading efficiency of ofloxacin, a hydrophilic drug encapsulated by hydrophobic polylactic-co-glycolic acid (PLGA) materials, through a double emulsion (water-in-oil-in-water) solvent extraction/evaporation method. Results from laser distributi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130863

    authors: Wu G,Chen L,Li H,Wang YJ

    更新日期:2014-01-01 00:00:00

  • Fracture behavior of dental composite resins.

    abstract::Fracture toughness (KIC), critical stress intensity factor, and bending strength of 3 types of commercially available dental composite resins (macrofilled, hybrid and microfilled type) were determined using three point bend specimens. Acoustic Emission (AE), which is the generation of elastic wave due to the release o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Kim KH,Park JH,Imai Y,Kishi T

    更新日期:1991-01-01 00:00:00

  • Bone regeneration from human mesenchymal stem cells on porous hydroxyapatite-PLGA-collagen bioactive polymer scaffolds.

    abstract::We have developed a novel multicomponent nano-hydroxyapatite-poly(D,L-lactide-co-glycolide)-collagen biomaterial (nHAP-PLGA-collagen) with mechanical properties similar to human cancellous bone. To demonstrate the bone forming capacity of nHAP-PLGA-collagen prior to in vivo experiments, nHAP-PLGA-collagen films and 3D...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171703

    authors: Bhuiyan DB,Middleton JC,Tannenbaum R,Wick TM

    更新日期:2017-01-01 00:00:00

  • Thermal-mechanical deformation modelling of soft tissues for thermal ablation.

    abstract::Modeling of thermal-induced mechanical behaviors of soft tissues is of great importance for thermal ablation. This paper presents a method by integrating the heating process with thermal-induced mechanical deformations of soft tissues for simulation and analysis of the thermal ablation process. This method combines bi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141043

    authors: Li X,Zhong Y,Jazar R,Subic A

    更新日期:2014-01-01 00:00:00

  • Improved bond performance of a dental adhesive system using nano-technology.

    abstract::Since adhesive technology was introduced into dental field, metal-based restoration has been gradually replaced by metal-free restoration. Using the adhesive technology, minimum invasive technique has been possible in daily clinical practice as well as esthetic tooth-colored restorations have become very popular all o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-2009-0587

    authors: Nagano F,Selimovic D,Noda M,Ikeda T,Tanaka T,Miyamoto Y,Koshiro K,Sano H

    更新日期:2009-01-01 00:00:00

  • Effect of calcium alginate concentration on viability and proliferation of encapsulated fibroblasts.

    abstract::Alginate hydrogels have been used widely in tissue engineering for cell encapsulation for several reasons: low toxicity, the ability to gel under gentle condition and compatibility with cells. In this study, we determined the effect of different concentrations of alginate on encapsulation of 3T3 fibroblast cells at tw...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0665

    authors: Bohari SP,Hukins DW,Grover LM

    更新日期:2011-01-01 00:00:00

  • Evaluation of NiTi Superelastic Retraction Coil Springs for orthodontic tooth movement in rats.

    abstract::The purpose of this investigation was to assess mechanical properties of Superelastic Retraction Coil Springs for orthodontic use. To reach a goal, a test frame, comprising measuring force transducers was developed. To perform metallographic analyses of the nickel-titanium wire the samples of Superelastic Retraction C...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0647

    authors: Rozman J,Mrvar P,Drevenšek M,Pečlin P

    更新日期:2010-01-01 00:00:00

  • Mechanical loading characteristics of total hip prosthetics subjected to dynamic loading cycles.

    abstract::The selection of best material pair in the hip prosthetics design for improved performance and life relies on the estimation of hip joint contact stresses and contact pressure distribution during various dynamic loading cycles: Climbing Upstairs, Climbing downstairs and Knee bending. The maximum Von Mises stress, cont...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181019

    authors: Kalayarasan M,Shankar S,Manikandan M,Adithan K

    更新日期:2018-01-01 00:00:00

  • Analysis of the effects of different materials in a tooth implant-supported fixed prosthesis using finite element method.

    abstract::In this study, design optimization of a tooth implant-supported fixed prosthesis was investigated theoretically. A three-dimensional finite element analysis was utilized to simulate the stress distribution and deformation, with an emphasis on the material selection for various parts of the prosthesis. This mandibular ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dargahi J,Najarian S,Talebi M

    更新日期:2005-01-01 00:00:00

  • Predicting the minimal inhibitory concentration of fluoroquinolones for Escherichia coli using an accumulation model.

    abstract::The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the "Fick-Nernst-Planck" equatio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141203

    authors: Zhang W,Wang C,Tam KY

    更新日期:2014-01-01 00:00:00

  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • Evaluation of the pro-angiogenic effect of nanoscale extracellular vesicles derived from human umbilical cord mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are a common tool in regenerative medicine. The nanoscale extracellular vesicles (nEVs) secreted by these cells were recently brought up to light thanks to their therapeutic potential. In this study, we assessed the in vitro behaviour of human umbilical vein endothelial cells (HUVECs) exp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171626

    authors: Dostert G,Willemin AS,Jouan-Hureaux V,Louis H,Hupont S,Gillet P,Menu P,Decot V,Moby V,Velot É

    更新日期:2017-01-01 00:00:00