New clinical failure mode triggered by a new coronary stent design.

Abstract:

:Longitudinal stent compression (LSC) is a new failure mode not previously observed in coronary stents. This phenomenon occurs when the physician tries to cross the deployed stent with other devices. While this phenomenon has been observed with a number of stent designs, it seems more common with the Element stent. A computational LSC model using finite element analysis was developed. Computational simulations were performed on two representative coronary stents in the current market resembling Element and Endeavor in attempts to quantify individual contribution of the stent design pattern and connector number on LSC. Simulation results show that the connector number plays the most significant role in the development of the LSC issue. The LSC could be easily tripled for the Element stent simply by increasing the connector number from two to three. The stent design pattern plays a secondary role in LSC. The LSC could be improved by up to 30% when the design pattern changes from the offset peak-to-peak design (Element) to the peak-to-peak design (Endeavor). Conclusions obtained from this paper may help clinical stent selection and future stent design optimization to reduce the risk associated with longitudinal stent compression.

journal_name

Biomed Mater Eng

authors

Hsiao HM,Yeh CT,Chiu YH,Wang C,Chen CP

doi

10.3233/BME-130781

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

37-43

issue

1

eissn

0959-2989

issn

1878-3619

pii

T517246G39649J71

journal_volume

24

pub_type

杂志文章
  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.

    abstract::The debris generated by the progressive wear of total joint replacement (TJR) devices is considered a primary cause of osteolysis, bone resorption, and premature failure of artificial hips and knees. The vast majority of this debris originates from the UHMWPE articulating surfaces caused by tribological interaction wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Davidson JA,Poggie RA,Mishra AK

    更新日期:1994-01-01 00:00:00

  • Hollow calcium phosphate microcarriers for bone regeneration: in vitro osteoproduction and ex vivo mechanical assessment.

    abstract::Synthetic grafting materials, such as calcium phosphates (hydroxyapatite, HA; tricalcium phosphate, TCP), polymers, or composites thereof, can be used as osteoconductive scaffolds and delivery vehicles for osteoinductive growth factors. Carrier materials must be engineered to deliver these factors in a controlled fash...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Santoni BG,Pluhar GE,Motta T,Wheeler DL

    更新日期:2007-01-01 00:00:00

  • Studies on quantitative analysis and automatic recognition of cell types of lung cancer.

    abstract::Recognition of lung cancer cells is very important to the clinical diagnosis of lung cancer. In this paper we present a novel method to extract the structure characteristics of lung cancer cells and automatically recognize their types. Firstly soft mathematical morphology methods are used to enhance the grayscale imag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chen YC,Hu KH,Li FZ,Li SY,Su WF,Huang ZY,Hu YX

    更新日期:2006-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Biocompatibility of 17-4 PH stainless steel foam for implant applications.

    abstract::In this study, biocompatibility of 17-4 PH stainless steel foam for biomedical implant applications was investigated. 17-4 PH stainless steel foams having porosities in the range of 40-82% with an average pore size of around 600 μm were produced by space holder-sintering technique. Sintered foams were precipitation ha...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0671

    authors: Mutlu I,Oktay E

    更新日期:2011-01-01 00:00:00

  • Different effects of nanophase and conventional hydroxyapatite thin films on attachment, proliferation and osteogenic differentiation of bone marrow derived mesenchymal stem cells.

    abstract:UNLABELLED:It is suggested that nanophase hydroxyapatite (nHAP) might have advantages over conventional hydroxyapatite (cHAP) as a biomaterial for bone regeneration. To be a satisfactory candidate for bone tissue engineering, it is important to support the growth and differentiation of bone marrow-derived mesenchymal s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zhou GS,Su ZY,Cai YR,Liu YK,Dai LC,Tang RK,Zhang M

    更新日期:2007-01-01 00:00:00

  • Predicting the minimal inhibitory concentration of fluoroquinolones for Escherichia coli using an accumulation model.

    abstract::The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the "Fick-Nernst-Planck" equatio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141203

    authors: Zhang W,Wang C,Tam KY

    更新日期:2014-01-01 00:00:00

  • Does artificial aging correctly predict the long-term in-vivo degradation behavior in zirconia hip prostheses?

    abstract:BACKGROUND:Accelerated hydrothermal aging has long been one of the most widely accepted quality control tests for simulating low-temperature degradation (LTD) in zirconia-containing implants used in total hip arthroplasty (THA). However, it is still unclear how much consistency there is between the experimental predict...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201083

    authors: Tateiwa T,Takahashi Y,Pezzotti G,Shishido T,Masaoka T,Sano K,Yamamoto K

    更新日期:2020-01-01 00:00:00

  • Introduction to tissue engineering and application for cartilage engineering.

    abstract::Tissue engineering is a multidisciplinary field that applies the principles of engineering, life sciences, cell and molecular biology toward the development of biological substitutes that restore, maintain, and improve tissue function. In Western Countries, tissues or cells management for clinical uses is a medical ac...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0624

    authors: de Isla N,Huseltein C,Jessel N,Pinzano A,Decot V,Magdalou J,Bensoussan D,Stoltz JF

    更新日期:2010-01-01 00:00:00

  • Experimal study of young male drivers' responses to vehicle collision using EMG of lower extremity.

    abstract::A driver's response to a front-coming vehicle collision consists of braking reaction time and braking behavior. The purpose was to investigate drivers' responses at different speeds, relative distances, and particularly the behavior on the accelerator at the collision moment. Twelve young men participated in driving s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151347

    authors: Gao Z,Li C,Hu H,Zhao H,Chen C,Yu H

    更新日期:2015-01-01 00:00:00

  • Thyroid hormone disorders and sepsis.

    abstract::Sepsis is a systemic inflammatory response syndrome with high mortality, which results from severe infection and can lead to secondary organ dysfunction. It is one of the most common cause of death in intensive care unit. Clinical reports have shown that sepsis was often accompanied by thyroid dysfunction, which is ca...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-171646

    authors: Luo B,Yu Z,Li Y

    更新日期:2017-01-01 00:00:00

  • The initial attachment and subsequent behavior of osteoblastic cells and oral epithelial cells on titanium.

    abstract::The interaction between implant materials and bone cells or oral epithelial (OE) cells contributes to the clinical success of dental implants. The functional activity of cells in contact with an implant is determined by its surface properties. Before cells attach, extracellular matrix (ECM) in the serum deposits on th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:

    authors: Goto T,Yoshinari M,Kobayashi S,Tanaka T

    更新日期:2004-01-01 00:00:00

  • Titanium-porcelain system. Part I: Oxidation kinetics of nitrided pure titanium, simulated to porcelain firing process.

    abstract::The bonding strength of porcelains to metals depends on the oxide layer between the porcelain and the metal. Oxidation of a metal surface increases the bonding strength, whereas excessive oxidation decreases it. Titanium and its alloys are gaining acceptance for dental use since they exhibit excellent biocompatibility...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshida Y,Hashem A

    更新日期:1993-01-01 00:00:00

  • Characterization of biomedical polymer surface interaction with human factor Xa.

    abstract::Two surface analytical spectroscopic techniques (namely, angular-dependent X-ray photoelectron spectroscopy and static secondary ion mass spectrometry) were used to characterize the nature and composition of the surface and near-surface layers formed on three biomedical polymers (namely, low-density polyethylene, expa...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G,Newman J,Katz W

    更新日期:1995-01-01 00:00:00

  • Effect of contacts configuration and location on selective stimulation of cuff electrode.

    abstract:BACKGROUND:Cuff electrodes have been widely used chronically in different clinical applications. Advancements have been made in selective stimulation by using multi-contact cuff electrodes. Steering anodic current is a strategy to increase selectivity by reshaping and localizing electric fields. There are two configura...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151281

    authors: Taghipour-Farshi H,Frounchi J,Ahmadiasl N,Shahabi P,Salekzamani Y

    更新日期:2015-01-01 00:00:00

  • Does adipose tissue cultured with collagen matrix and preadipocytes give comparable results to the standard technique in plastic surgery?

    abstract:INTRODUCTION:Repairing contour defects is a challenge in plastic surgery. Different filling materials have been used with inadequate results and complications. The autologous fat transfer is the standard technique at the moment, but adipose tissue reserves are limited. The aim of our study was to compare in vivo on an ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Mojallal A,Lequeux C,Auxenfans C,Braye F,Damour O

    更新日期:2008-01-01 00:00:00

  • Multiphysics of bone remodeling: A 2D mesoscale activation simulation.

    abstract::In this work, we present an evolutive trabecular model for bone remodeling based on a boundary detection algorithm accounting for both biology and applied mechanical forces, known to be an important factor in bone evolution. A finite element (FE) numerical model using the Abaqus/Standard® software was used with a UMAT...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171636

    authors: Spingarn C,Wagner D,Rémond Y,George D

    更新日期:2017-01-01 00:00:00

  • A statistical approach to segmentation of diffusion tensor imaging.

    abstract::The aim of this study is to design a statistical segmentation technique to allow extraction of grey matter, white matter and cerebral spinal fluid volumes from diffusion tensor imaging. Four channel maps of the DTI are used as the input features, which provide more information for brain tissue segmentation compared wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130927

    authors: Wen Y,He L

    更新日期:2014-01-01 00:00:00

  • Analysis of basal physical fitness and lumbar muscle function according to indoor horse riding exercise.

    abstract::The aim of this study is to verify the effect of indoor horse riding exercise on basal physical exercise and lumbar muscular function. The subjects included were 20 healthy females, who participated in the horse riding exercise using SRider (Rider Co. & ChonbuK National Univ, Korea) for 30 minutes per day, 3 days per ...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-141053

    authors: Yu CH,Hong CU,Kang SR,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Tight medial knot tying may increase retearing risk after transosseous equivalent repair of rotator cuff tendon.

    abstract:BACKGROUND:Retearing mechanism after transosseous equivalent (TOE) rotator cuff repair has not been fully clarified yet. OBJECTIVE:The purposes of this study were to compare the stress distribution pattern in the tendon stump between knotted and knotless TOE repair and to investigate the role of suture tension applied...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171673

    authors: Sano H,Tokunaga M,Noguchi M,Inawashiro T,Irie T,Abe H,Yokobori AT

    更新日期:2017-01-01 00:00:00

  • Flow visualization in the outflow cannula of an axial blood pump.

    abstract::The properties of blood flow in the outflow cannula of an axial blood pump play a critical role in potential thrombus formation and vascular injury. In this study, an in vitro flow visualization technique using particle image velocimetry (PIV) was applied to investigate the flow characteristics in the outflow cannula ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130791

    authors: Liu G,Zhang Y,Chen H,Sun H,Zhou J,Hu S

    更新日期:2014-01-01 00:00:00

  • Stability of gabexate mesilate products: Influence of the addition of mannitol.

    abstract::Gabexate mesilate is a non-peptide protease inhibitor, developed in Japan, which is used in the treatment of acute pancreatitis and disseminated intravascular coagulation. This compound is readily hydrolyzed as it has ester bonds in its structure. It is now out of patent in Japan and there are many generic versions on...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0611

    authors: Sakurai M,Abe H,Okamura N,Inoue Y,Akiyoshi T,Matsuyama K,Uchida T,Otsuka M

    更新日期:2010-01-01 00:00:00

  • Mechanical strength of sutured block copolymers films for load bearing medical applications.

    abstract::The mechanical behavior of three styrenic thermoplastic block copolymer elastomers with applied surgical sutures was studied by uniaxial tensile testing. The materials exhibited oriented cylindrical microstructure. Distinct macroscopic deformation mechanisms have been observed upon stretching of samples with vertical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130843

    authors: Stasiak J,Nair S,Moggridge GD

    更新日期:2014-01-01 00:00:00

  • Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

    abstract::In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zaki M,Aljinaidi A,Hamed M

    更新日期:2003-01-01 00:00:00

  • The effect of counter-ions on the ion selectivity of potassium and sodium ions in nanopores.

    abstract::The ion selective transport plays an important role in the function of cell membranes, and promotes the application of artificial permeable membranes. This phenomenon has been studied in case for different diameters and functional groups of nanopores. In this work, we focus on the effect of anions on cation selectivit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130822

    authors: Tang D,Kim D

    更新日期:2014-01-01 00:00:00

  • An ensemble feature selection technique for cancer recognition.

    abstract::Correlation-based feature selection (CFS) using neighborhood mutual information (NMI) and particle swarm optimization (PSO) are combined into an ensemble technique in this paper. Based on this observation, an efficient gene selection algorithm, denoted by NMICFS-PSO, is proposed. Several cancer recognition tasks are g...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130897

    authors: Xu J,Sun L,Gao Y,Xu T

    更新日期:2014-01-01 00:00:00

  • Improved bond performance of a dental adhesive system using nano-technology.

    abstract::Since adhesive technology was introduced into dental field, metal-based restoration has been gradually replaced by metal-free restoration. Using the adhesive technology, minimum invasive technique has been possible in daily clinical practice as well as esthetic tooth-colored restorations have become very popular all o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-2009-0587

    authors: Nagano F,Selimovic D,Noda M,Ikeda T,Tanaka T,Miyamoto Y,Koshiro K,Sano H

    更新日期:2009-01-01 00:00:00

  • Accelerating sino-atrium computer simulations with graphic processing units.

    abstract::Sino-atrial node cells (SANCs) play a significant role in rhythmic firing. To investigate their role in arrhythmia and interactions with the atrium, computer simulations based on cellular dynamic mathematical models are generally used. However, the large-scale computation usually makes research difficult, given the li...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151365

    authors: Zhang H,Xiao Z,Lin SF

    更新日期:2015-01-01 00:00:00

  • Rapid counting method of living cells by fluorescent enzyme substrates.

    abstract::The 5(and 6)-carboxyfluorescein diacetate (C-FDA) is used for a rapid and continuous counting of living cells. Nonfluorescent C-FDA is converted into fluorescent 5(and 6)-carboxyfluorescein (C-F) by the reaction with esterase, which is an enzyme of living cells. The conversion makes it possible to count the number of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sugata K,Ohnishi T,Matsumoto K