Abstract:
:Hydroxyapatite was coated with 1 microm thickness on titanium columns of a length of 10 mm, an outer diameter of 4.0 mm by radio frequency magnetron sputtering. The hydroxyapatite coating titanium columns were implanted in the diaphysis of femora of 3 adult dogs, and push-out test was carried out after 2, 4 and 12 weeks of implantation using a testing machine. The interface of bone/column was observed histologically after the test. At 12 weeks the push-out strengths of coating and non-coating columns were 3.5 and 1 MPa, respectively. Histological observation indicated a formation of thin connective tissue with 5-30 microm thickness at the interface of the bone/column. No inflammation was observed during the implantation periods.
journal_name
Biomed Mater Engjournal_title
Bio-medical materials and engineeringauthors
Ozeki K,Yuhta T,Aoki H,Nishimura I,Fukui Ysubject
Has Abstractpub_date
2001-01-01 00:00:00pages
63-8issue
1eissn
0959-2989issn
1878-3619journal_volume
11pub_type
杂志文章abstract::Some computer applications for cell characterization in medicine and biology, such as analysis of surface structure of cell wall-deficient EVC (El Tor Vibrio of Cholera), operate with cell samples taken from very small areas of interest. In order to perform texture characterization in such an application, only a few t...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2001-01-01 00:00:00
abstract::The mechanical behavior of three styrenic thermoplastic block copolymer elastomers with applied surgical sutures was studied by uniaxial tensile testing. The materials exhibited oriented cylindrical microstructure. Distinct macroscopic deformation mechanisms have been observed upon stretching of samples with vertical ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130843
更新日期:2014-01-01 00:00:00
abstract:BACKGROUND:Introduction of a new generation of artificial ligaments for ACL reconstruction, the Ligament Augmentation and Reconstruction System (LARS), gives promising clinical results [1]. The current literature supports the use of LARS from short to medium term. To go even further to improve the biocompatibility of t...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130753
更新日期:2013-01-01 00:00:00
abstract::In this investigation, ultrasonic parameters of kidney stones are measured, in vitro, using a double probe ultrasonic-through-transmission technique. Due to the complex chemical structure of these stones, a large variation in the values of the ultrasonic parameters is found. A correlation between ultrasonic properties...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1992-07-01 00:00:00
abstract::Morse code is now being harnessed for use in rehabilitation applications of augmentative-alternative communication and assistive technology, including mobility, environmental control and adapted worksite access. In this paper, Morse code is selected as a communication adaptive device for disabled persons who suffer fr...
journal_title:Bio-medical materials and engineering
pub_type: 临床试验,杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract::A potassium-doped synthetic apatite was prepared by soaking hydroxyapatite in potassium carbonate and potassium chloride solutions. The hydroxyapatite was prepared by firing slip cast ceramic bodies in vacuum at 1100 degrees C. The conical ceramic samples and a crushed material of this were soaked in carbonate and chl...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipu...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-141023
更新日期:2014-01-01 00:00:00
abstract::The interactions between carbon nanotubes and important biomolecules, above all collagen molecules, have not been studied in detail. This situation is partly due to the fact that CNT are solid entities, while most of the biomolecules can be prepared in solution. We used turbidity as a means of evaluating the interacti...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2009-0557
更新日期:2009-01-01 00:00:00
abstract:BACKGROUND:The most common cause of coronary artery disease (CAD) is vascular damage with the cholesterol built-up and other materials on the inner arterial wall, known as atherosclerosis. OBJECTIVE:This paper aims to investigate the effect of stenosis on the hemodynamics in the four suspected coronary artery disease ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-191067
更新日期:2019-01-01 00:00:00
abstract::Age-related macular degeneration (ARMD) and intraocular neovascular diseases have been treated clinically by anti-VEGF antibody drug bevacizumab. However, the use of bevacizumab in the treatment of retinal neovascular diseases has been limited due to the short half-life and frequent injections. In this research, novel...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-141003
更新日期:2014-01-01 00:00:00
abstract::The objective of the present study was to find a standard substance for use as a reference in the cytotoxicity assay of biomaterials, as an alternative to animal experiments in recent years. Eight kinds of rubber were made in a plate shape to keep their surface area at 1 cm2 against 10 ml of extract volume. They were ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::In this work composite materials, based on quartz fibers and epoxy resins, were employed with the aim to restore damaged teeth. The composite materials were chosen because they show biomechanical features very similar to that of the dentine, the main constituent of the tooth. Extracted teeth were rebuilt with two diff...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2006-01-01 00:00:00
abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130811
更新日期:2014-01-01 00:00:00
abstract::To select tag single nucleotide polymorphisms (SNPs) within and around human p75 neurotrophin receptor (p75NTR) gene in Chinese Han population, the sequence involving p75NTR gene as well as the upstream and downstream of the gene was identified according to the data from National Center for Biotechnology Information (...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-141213
更新日期:2014-01-01 00:00:00
abstract::The in vivo and in vitro drug release profiles from a self-setting bioactive CaO-SiO2-P2O5 glass bone cement containing indomethacin as a model drug were investigated. The cement containing 2% and 5% indomethacin (IMC) powder hardened within 5 min after mixing with ammonium phosphate buffer. After setting, in vitro dr...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1997-01-01 00:00:00
abstract::The current density of Ti-56mass%Ni (Ti-50at.%) alloy after abrasion in simulated bioliquids was measured using a potentiostat to estimate the amount of metallic ions released from the alloy during repassivation and maturation. The current density in saline, saline with and without N2 bubbling, and Hanks' solutions wi...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:1999-01-01 00:00:00
abstract::Polycrystalline diamond (PCD) exhibits excellent abrasive characteristics and is commonly used as loose grains for precision machining of hard ceramics and other materials that are difficult to grind and polish. In the present study, we investigated using bonded PCD for polishing dental porcelain, for which a lustrous...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2010-0642
更新日期:2010-01-01 00:00:00
abstract::Bioartificial liver support provides a bridge to transplantation which is at present the only proven specific treatment for acute liver failure. In this paper, a novel multi-coaxial hollow fiber bioreactor so-called "Fibre-in-Fibre FIF Bioartificial liver device" with three compartments is experimentally and mathemati...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130762
更新日期:2013-01-01 00:00:00
abstract::The balance between extracellular inorganic phosphate (ePi) and extracellular inorganic pyrophosphate (ePPi) is controlled by four membrane proteins: the transporters ANK (exporting PPi outside the cells) and PiT-1 (importing ePi into the cells), and the enzymes PC-1 (generating ePPi from nucleotides) and Tissue Non-s...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2010-0634
更新日期:2010-01-01 00:00:00
abstract::The aim of this work was to investigate the effect of 2.4 MeV proton irradiation on the dielectric property of polyethylene terephthalate (PET) microfibre nondestructively. The dielectric constant εd of single-microfibre has been measured as-such applying laser diffraction technique. Applying this methodology εd is fo...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130947
更新日期:2014-01-01 00:00:00
abstract::The hip stem design based upon X-ray films requires sufficient information in order to customize for the patient. If the errors are resulted from rotating angles, more X-ray films may carry out the solution. The present study aimed to realize the improvement of multiple X-ray films for hip stem design. Eight X-ray fil...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract::This study aimed to determine the optimal starting material for the development of an acellular osteochondral graft. Osteochondral tissues from three different species were characterised; pig (6 months), cow (18 months) and two ages of sheep (8-12 months and >4 year old). Tissues from the acetabulum and femoral head o...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-151533
更新日期:2015-01-01 00:00:00
abstract::The ion selective transport plays an important role in the function of cell membranes, and promotes the application of artificial permeable membranes. This phenomenon has been studied in case for different diameters and functional groups of nanopores. In this work, we focus on the effect of anions on cation selectivit...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130822
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:To establish a method for mouse coronary angiography in vivo using synchrotron radiation, which is essential for physiological and pathological research on coronary diseases. METHODS:1) The imaging parameters (e.g., photon energy, spatial resolution of the detector, and injection rate of contrast agent) optima...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130937
更新日期:2014-01-01 00:00:00
abstract:INTRODUCTION:Repairing contour defects is a challenge in plastic surgery. Different filling materials have been used with inadequate results and complications. The autologous fat transfer is the standard technique at the moment, but adipose tissue reserves are limited. The aim of our study was to compare in vivo on an ...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2008-01-01 00:00:00
abstract::Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydro...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:
更新日期:2007-01-01 00:00:00
abstract:OBJECTIVE:To characterize the structure and to evaluate the cytotoxicity of cellulose nanowhiskers (CNW) prepared from cotton linters. METHODS:A series of CNW dispersions was prepared by hydrolyzing cotton linters with sulfuric acid. The structure of CNW was characterized by scanning electron microscopy (SEM), transmi...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2012-0697
更新日期:2012-01-01 00:00:00
abstract::Stroke is a major cause of death and disability throughout the world. Subtotal occlusion of the carotid artery is an important risk factor for stroke. Carotid artery stenting (CAS) is increasingly being used for treatment of carotid artery stenosis. There are many reports on treating carotid artery stenosis by CAS; ho...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-2012-0687
更新日期:2012-01-01 00:00:00
abstract::This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value of kidney imaging with phase contrast imaging technology. In our experiment, spatial resolution and tissue contrast serve as element evaluation and comparison....
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-130917
更新日期:2014-01-01 00:00:00
abstract::Wearable robotic devices provide safe and intensive rehabilitation, enabling repeated motions for motor function recovery in stroke patients. The aim of this small case series was to demonstrate the training effects of a three-week robotic leg orthosis, and to investigate possible mechanisms of the sensory-motor alter...
journal_title:Bio-medical materials and engineering
pub_type: 杂志文章
doi:10.3233/BME-151320
更新日期:2015-01-01 00:00:00