Cellulose nanowhiskers: preparation, characterization and cytotoxicity evaluation.

Abstract:

OBJECTIVE:To characterize the structure and to evaluate the cytotoxicity of cellulose nanowhiskers (CNW) prepared from cotton linters. METHODS:A series of CNW dispersions was prepared by hydrolyzing cotton linters with sulfuric acid. The structure of CNW was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and X-ray diffraction (XRD). The cytotoxicity of CNW dispersions to L929 cells was preliminarily investigated by cell culture and MTT assay. RESULTS:SEM and TEM observation showed that the original cotton litters have been successfully acid-hydrolyzed into cellulose nanowhiskers having needle- or short rod-like structure with an average length of 250 nm and diameter of 10 nm. XRD patterns suggested that degree of crystalline in the CNW was much higher than that in the cotton linters as a result that the acid-hydrolysis process has removed the amorphous domains in the cotton linters. The results from MTT assay and cell morphology observation indicated that CNW with concentration from 0.01% to 0.2% had low toxicity to L929 cells, while cytotoxicity showed an increase tendency with an increase in the concentration of CNW. CONCLUSIONS:Cellulose nanowhiskers dispersion could be prepared from cotton linters by acid-hydrolysis process. CNW showed potential applications as nanobiomaterials due to its low cytotoxicity.

journal_name

Biomed Mater Eng

authors

Ni H,Zeng S,Wu J,Cheng X,Luo T,Wang W,Zeng W,Chen Y

doi

10.3233/BME-2012-0697

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

121-7

issue

1-3

eissn

0959-2989

issn

1878-3619

pii

V3278M2723151721

journal_volume

22

pub_type

杂志文章
  • Tinting effect of ultraviolet radiation on intraocular lenses of polymethyl methacrylate.

    abstract::Intraocular lenses (IOL) made of polymethyl methacrylate (PMMA) lack an important yellowish pigment useful as a filter in the visual process and in the protection of the retina from short wavelength light. It was found that the PMMA used for IOL manufacturing can be tinted by dry exposure to mercury near-UV emitting l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Babizhayev MA,Chumayevskii NA

    更新日期:1994-01-01 00:00:00

  • Different effects of nanophase and conventional hydroxyapatite thin films on attachment, proliferation and osteogenic differentiation of bone marrow derived mesenchymal stem cells.

    abstract:UNLABELLED:It is suggested that nanophase hydroxyapatite (nHAP) might have advantages over conventional hydroxyapatite (cHAP) as a biomaterial for bone regeneration. To be a satisfactory candidate for bone tissue engineering, it is important to support the growth and differentiation of bone marrow-derived mesenchymal s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zhou GS,Su ZY,Cai YR,Liu YK,Dai LC,Tang RK,Zhang M

    更新日期:2007-01-01 00:00:00

  • The influence of Zn on the deposition of HA on sol-gel derived bioactive glass.

    abstract::To evaluate the influence of Zn on the formation of hydroxyapatite (HA), zinc-containing glass 58S4Z was prepared by substitution of CaO with 4 wt% ZnO in 58S bioactive glass, and Zn-containing simulated body fluid (ZnSBF) was prepared as soaking fluid. During the soaking, all samples could induce the deposition of HA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du RL,Chang J

    更新日期:2006-01-01 00:00:00

  • Failed attempts and improvement strategies in peripheral intravenous catheterization.

    abstract:BACKGROUND:Access to peripheral veins is necessary for sample collection, transfusion and infusion of fluids or medications. The peripheral intravenous catheterization (PIVC) procedure is the introduction of a short catheter into a peripheral vein and can be problematic, leading to multiple failed attempts. PURPOSE:To...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-120735

    authors: Sabri A,Szalas J,Holmes KS,Labib L,Mussivand T

    更新日期:2013-01-01 00:00:00

  • Effect of contacts configuration and location on selective stimulation of cuff electrode.

    abstract:BACKGROUND:Cuff electrodes have been widely used chronically in different clinical applications. Advancements have been made in selective stimulation by using multi-contact cuff electrodes. Steering anodic current is a strategy to increase selectivity by reshaping and localizing electric fields. There are two configura...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151281

    authors: Taghipour-Farshi H,Frounchi J,Ahmadiasl N,Shahabi P,Salekzamani Y

    更新日期:2015-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • 4D model of hemodynamics in the abdominal aorta.

    abstract::The paper presents an application of the FSI technique to determine hemodynamics in the abdominal aorta (AA). To establish boundary conditions for the FSI study, MR anatomical data and 4D MRI velocity-mapping data (in three blood flow velocity directions and time) were collected to acquire realistic geometry of the AA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151312

    authors: Zbicinski I,Veshkina N,Stefańczyk L

    更新日期:2015-01-01 00:00:00

  • An experimental study on the biomechanical properties of the cancellous bones of distal femur.

    abstract:OBJECTIVE:To study the comprehensive biomechanical properties of the cancellous bone of distal femur through a series of mechanical tests, and provide relevant subjects with the basic technical data. BACKGROUND:The study on bone mechanics is a commonly used approach to evaluate the biomechanical competency of bone. Th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du C,Ma H,Ruo M,Zhang Z,Yu X,Zeng Y

    更新日期:2006-01-01 00:00:00

  • Fracture behavior of dental composite resins.

    abstract::Fracture toughness (KIC), critical stress intensity factor, and bending strength of 3 types of commercially available dental composite resins (macrofilled, hybrid and microfilled type) were determined using three point bend specimens. Acoustic Emission (AE), which is the generation of elastic wave due to the release o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Kim KH,Park JH,Imai Y,Kishi T

    更新日期:1991-01-01 00:00:00

  • Studies on poly(propylene fumarate-co-ethylene glycol) based bone cement.

    abstract::Poly(propylene fumarate-co-ethylene glycol) random (PPF-1) and block (PPF-2) copolymer oligomers were prepared. Comparing the setting characteristics of PPF-1 and PPF-2 with comonomer n-vinyl pyrrolidone (n-VP) and swelling characteristics of cured PPF-1 and PPF-2, lower setting temperature and setting time was observ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Jayabalan M,Thomas V,Sreelatha PK

    更新日期:2000-01-01 00:00:00

  • Investigation of mechanical compatibility of hernia meshes and human abdominal fascia.

    abstract:OBJECTIVE:Understanding the biomechanical properties of hernia meshes is essential in facilitating their selection. The aim of this study was to evaluate the mechanical compatibility of hernia meshes and human abdominal fascia and assess their applicability in hernia repair. METHODS:Uniaxial tensile tests were perform...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171719

    authors: Doneva M,Pashkouleva D

    更新日期:2018-01-01 00:00:00

  • Sparse-view computed tomography image reconstruction via a combination of L(1) and SL(0) regularization.

    abstract::Low-dose computed tomography reconstruction is an important issue in the medical imaging domain. Sparse-view has been widely studied as a potential strategy. Compressed sensing (CS) method has shown great potential to reconstruct high-quality CT images from sparse-view projection data. Nonetheless, low-contrast struct...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151437

    authors: Qi H,Chen Z,Guo J,Zhou L

    更新日期:2015-01-01 00:00:00

  • Mechanical properties of cancellous tissue in compression test and nanoindentation.

    abstract::The goal of the study was to determine material constants of cancellous tissue in a compression test taking into account stress-strain characteristics. The nineteen test samples were resected from a femoral head of a patient qualified for a hip replacement surgery. During the compression tests, load-displacement curve...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-180999

    authors: Kokot G,Makuch A,Skalski K,Bańczerowski J

    更新日期:2018-01-01 00:00:00

  • Effect of calcium alginate concentration on viability and proliferation of encapsulated fibroblasts.

    abstract::Alginate hydrogels have been used widely in tissue engineering for cell encapsulation for several reasons: low toxicity, the ability to gel under gentle condition and compatibility with cells. In this study, we determined the effect of different concentrations of alginate on encapsulation of 3T3 fibroblast cells at tw...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0665

    authors: Bohari SP,Hukins DW,Grover LM

    更新日期:2011-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • Automatic analysis of image of surface structure of cell wall-deficient EVC.

    abstract::Some computer applications for cell characterization in medicine and biology, such as analysis of surface structure of cell wall-deficient EVC (El Tor Vibrio of Cholera), operate with cell samples taken from very small areas of interest. In order to perform texture characterization in such an application, only a few t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Li S,Hu K,Cai N,Su W,Xiong H,Lou Z,Lin T,Hu Y

    更新日期:2001-01-01 00:00:00

  • Analysis of basal physical fitness and lumbar muscle function according to indoor horse riding exercise.

    abstract::The aim of this study is to verify the effect of indoor horse riding exercise on basal physical exercise and lumbar muscular function. The subjects included were 20 healthy females, who participated in the horse riding exercise using SRider (Rider Co. & ChonbuK National Univ, Korea) for 30 minutes per day, 3 days per ...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-141053

    authors: Yu CH,Hong CU,Kang SR,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Mechanical strength of sutured block copolymers films for load bearing medical applications.

    abstract::The mechanical behavior of three styrenic thermoplastic block copolymer elastomers with applied surgical sutures was studied by uniaxial tensile testing. The materials exhibited oriented cylindrical microstructure. Distinct macroscopic deformation mechanisms have been observed upon stretching of samples with vertical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130843

    authors: Stasiak J,Nair S,Moggridge GD

    更新日期:2014-01-01 00:00:00

  • A study of load cycling in a NiTi shape memory alloy with pseudoelastic behaviour used in dental prosthetic fixators.

    abstract::NiTi alloy used in dental prosthetic fixators shows pseudoelastic behaviour and exhibits a great potential in dental and orthopaedic applications where constant correcting loads are required. In order to use such materials in dental prosthetic fixators, where the device is cyclically deformed, it is necessary to inves...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sabrià J,Cortada M,Giner L,Gil FJ,Fernández E,Manero JM,Planell JA

    更新日期:1996-01-01 00:00:00

  • Crystal chemistry of hydroxyapatite deposited on titanium by sputtering technique.

    abstract::Crystalline hydroxyapatite (HA) powder was coated on titanium substrate by radio frequency (RF) magnetron sputtering. The coating was homogeneous thin film and the thickness was 1microm. Crystallinity of the HA coating was low and Ca/P ratio was high as 3.0. Particle sizes were 40 to approximately 100 nm, and the crys...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Nishimura I,Fukui Y

    更新日期:2000-01-01 00:00:00

  • Wave propagation in the silicon tube: comparison of the two-point and three-point pressure methods.

    abstract::The values of the propagation coefficient measured on a silicon rubber tube in the frequency range 1-15 Hz were compared, using four different equations. The first formula is based on three simultaneous pressure measurements performed at equidistant points; the remaining three equations are original, and make use of o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ursino M,Artioli E

    更新日期:1992-10-01 00:00:00

  • Use of enzyme-linked immunosorbent assay (ELISA) for detection and quantification of monoclonal antibodies.

    abstract::The thrust of the present work is the demonstration of the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of a monoclonal antibody human serum. The antibodies used, 7E3 and D3GP3, have been proposed as platelet receptor blockers, being directed specifically again...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G

    更新日期:1994-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Experimental exploration of mouse kidney imaging with the SR PCI technology.

    abstract::This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value of kidney imaging with phase contrast imaging technology. In our experiment, spatial resolution and tissue contrast serve as element evaluation and comparison....

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130917

    authors: Xia C,Peng YF,Arun KY,Xiao T,Zhu P,He W

    更新日期:2014-01-01 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Titanium-porcelain system. Part I: Oxidation kinetics of nitrided pure titanium, simulated to porcelain firing process.

    abstract::The bonding strength of porcelains to metals depends on the oxide layer between the porcelain and the metal. Oxidation of a metal surface increases the bonding strength, whereas excessive oxidation decreases it. Titanium and its alloys are gaining acceptance for dental use since they exhibit excellent biocompatibility...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshida Y,Hashem A

    更新日期:1993-01-01 00:00:00

  • Material removal during the sliding of hydroxyapatite against UHMWPE.

    abstract::Hydroxyapatite has been rubbed against ultra-high-molecular-weight-polyethylene (UHMWPE) under calcium-containg aqueous solutions. Further, hardness tests were carried out in air and in calcium-containing solutions whose pH ranged from pH 5 to pH 9. Hardness was found to vary with pH with a peak at around pH 7, i.e. -...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Mazeau G,Czernuszka JT

    更新日期:2001-01-01 00:00:00

  • Studies on quantitative analysis and automatic recognition of cell types of lung cancer.

    abstract::Recognition of lung cancer cells is very important to the clinical diagnosis of lung cancer. In this paper we present a novel method to extract the structure characteristics of lung cancer cells and automatically recognize their types. Firstly soft mathematical morphology methods are used to enhance the grayscale imag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chen YC,Hu KH,Li FZ,Li SY,Su WF,Huang ZY,Hu YX

    更新日期:2006-01-01 00:00:00

  • SIFT algorithm-based 3D pose estimation of femur.

    abstract::To address the lack of 3D space information in the digital radiography of a patient femur, a pose estimation method based on 2D-3D rigid registration is proposed in this study. The method uses two digital radiography images to realize the preoperative 3D visualization of a fractured femur. Compared with the pure Digit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141103

    authors: Zhang X,Zhu Y,Li C,Zhao J,Li G

    更新日期:2014-01-01 00:00:00

  • Development of SPR biosensor for simultaneous detection of multiplex respiratory viruses.

    abstract::A surface plasmon resonance (SPR)-based biosensor was developed for specific detection of nine common respiratory virus, including influenza A and influenza B, H1N1, respiratory syncytial virus (RSV), parainfluenza virus 1-3 (PIV1, 2, 3), adenovirus, and severe acute respiratory syndrome coronavirus (SARS). The SPR bi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151526

    authors: Shi L,Sun Q,He J,Xu H,Liu C,Zhao C,Xu Y,Wu C,Xiang J,Gu D,Long J,Lan H

    更新日期:2015-01-01 00:00:00