Development of SPR biosensor for simultaneous detection of multiplex respiratory viruses.

Abstract:

:A surface plasmon resonance (SPR)-based biosensor was developed for specific detection of nine common respiratory virus, including influenza A and influenza B, H1N1, respiratory syncytial virus (RSV), parainfluenza virus 1-3 (PIV1, 2, 3), adenovirus, and severe acute respiratory syndrome coronavirus (SARS). The SPR biosensor was developed by immobilizing nine respiratory virus-specific oligonucleotides in an SPR chip. To increase the biosensor sensitivity, biotin was used to label the PCR primer and further amplify the signal by introducing streptavidin after hybridization. Throat swab specimens representing nine common respiratory viruses were tested by the innovative SPR-based biosensor to evaluate the sensitivity, specificity and reproducibility of this method. Results suggest that this biosensor has the potential to simultaneously identify common respiratory viruses.

journal_name

Biomed Mater Eng

authors

Shi L,Sun Q,He J,Xu H,Liu C,Zhao C,Xu Y,Wu C,Xiang J,Gu D,Long J,Lan H

doi

10.3233/BME-151526

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

S2207-16

eissn

0959-2989

issn

1878-3619

pii

BME1526

journal_volume

26 Suppl 1

pub_type

杂志文章
  • Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    abstract::A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Jones VC,Barton DC,Auger DD,Hardaker C,Stone MH,Fisher J

    更新日期:2001-01-01 00:00:00

  • Tinting effect of ultraviolet radiation on intraocular lenses of polymethyl methacrylate.

    abstract::Intraocular lenses (IOL) made of polymethyl methacrylate (PMMA) lack an important yellowish pigment useful as a filter in the visual process and in the protection of the retina from short wavelength light. It was found that the PMMA used for IOL manufacturing can be tinted by dry exposure to mercury near-UV emitting l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Babizhayev MA,Chumayevskii NA

    更新日期:1994-01-01 00:00:00

  • Regulation of periodontal ligament-derived cells by type III collagen-coated hydroxyapatite.

    abstract:BACKGROUND:The periodontal ligament (PDL), which maintains homeostasis in the periodontium, is a group of specialized connective tissue fibers attached to both the cementum and alveolar bone. Regeneration of periodontium with PDL cells has been investigated, and the chemical and molecular structures of scaffolds contro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171709

    authors: Fujita K,Nozaki K,Horiuchi N,Yamashita K,Miura H,Nagai A

    更新日期:2018-01-01 00:00:00

  • Biological, biochemical and biomechanical characterisation of articular cartilage from the porcine, bovine and ovine hip and knee.

    abstract::This study aimed to determine the optimal starting material for the development of an acellular osteochondral graft. Osteochondral tissues from three different species were characterised; pig (6 months), cow (18 months) and two ages of sheep (8-12 months and >4 year old). Tissues from the acetabulum and femoral head o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151533

    authors: Fermor HL,McLure SW,Taylor SD,Russell SL,Williams S,Fisher J,Ingham E

    更新日期:2015-01-01 00:00:00

  • A new method to accurately assess post-laser-surgery refractive changes with the intrinsic corneal power changes.

    abstract::To evaluate the ability of assessing the refractive change induced by myopic laser surgery using the intrinsic data, obtained from a reference intrinsic to the cornea. Twenty-nine eyes with laser in situ keratomileusis for myopia were included in the study. Statistical analyses were performed to determine the relation...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-151374

    authors: Liu Y,Wang Z,Wang Y

    更新日期:2015-01-01 00:00:00

  • The mechanical-chemical attachment between the artificial articular cartilage (PVA-hydrogel) and metal substrate (or underlying bone).

    abstract::PVA-hydrogel has excellent biocompatibility as well as preferable tribological characteristics as an artificial articular cartilage. One of the most difficult problems is the attachment of PVA-hydrogel to the underlying bone (or metal substrate). In the present study, the micro-mechanical attachment between the PVA-hy...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gu ZQ,Xiao JM,Lou SQ

    更新日期:1999-01-01 00:00:00

  • Sterilization of auto-crosslinked hyaluronic acid scaffolds structured in microparticles and sponges.

    abstract::This work evaluated the effects of UV irradiation, plasma radiation, steam and 70% ethanol treatments on the sterilization and integrity of auto-crosslinked hyaluronic acid (HA-ACP) scaffolds structured in microparticles and sponges aiming in vivo applications for regenerative medicine of bone tissue. The integrity of...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151558

    authors: Shimojo AA,de Souza Brissac IC,Pina LM,Lambert CS,Santana MH

    更新日期:2015-01-01 00:00:00

  • Simultaneous quantitative analysis of indomethacin and benzoic acid in gel using ultra-violet-visible spectrophotometry and chemometrics.

    abstract:BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out qu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181034

    authors: Peerapattana J,Hattori Y,Otsuka M

    更新日期:2019-01-01 00:00:00

  • Biocompatibility of 17-4 PH stainless steel foam for implant applications.

    abstract::In this study, biocompatibility of 17-4 PH stainless steel foam for biomedical implant applications was investigated. 17-4 PH stainless steel foams having porosities in the range of 40-82% with an average pore size of around 600 μm were produced by space holder-sintering technique. Sintered foams were precipitation ha...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0671

    authors: Mutlu I,Oktay E

    更新日期:2011-01-01 00:00:00

  • Wave propagation in the silicon tube: comparison of the two-point and three-point pressure methods.

    abstract::The values of the propagation coefficient measured on a silicon rubber tube in the frequency range 1-15 Hz were compared, using four different equations. The first formula is based on three simultaneous pressure measurements performed at equidistant points; the remaining three equations are original, and make use of o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ursino M,Artioli E

    更新日期:1992-10-01 00:00:00

  • Multiphysics of bone remodeling: A 2D mesoscale activation simulation.

    abstract::In this work, we present an evolutive trabecular model for bone remodeling based on a boundary detection algorithm accounting for both biology and applied mechanical forces, known to be an important factor in bone evolution. A finite element (FE) numerical model using the Abaqus/Standard® software was used with a UMAT...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171636

    authors: Spingarn C,Wagner D,Rémond Y,George D

    更新日期:2017-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00

  • Optically-guided scalpel with light-scattering module for carpal tunnel surgical procedure via minimally invasive surgery.

    abstract::A novel technique and product for carpal tunnel microscopic surgical procedures using a modified medical device containing a head as a surgical scalpel under light guidance were designed and studied. The novel design of the medical device was developed and applied in a new carpal tunnel microscopic surgical procedure ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151303

    authors: Chiang MC,Huang CC

    更新日期:2015-01-01 00:00:00

  • Effect of cancellous bone on the functionally graded dental implant concept.

    abstract::In a previous work by the author [H.S. Hedia and M. Nemat-Alla, Design optimization of functionally graded dental implant, submitted to be published in the J. Bio-Medical Materials and Engineering], a functionally graded material dental implant was designed without cansellous bone in the model. In this investigation t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Hedia HS

    更新日期:2005-01-01 00:00:00

  • Oxymatrine inhibited cell proliferation by inducing apoptosis in human lung cancer A549 cells.

    abstract::To investigate the inhibition effect of oxymatrine induces human lung cancer A549 cells apoptosis. The A549 cells were cultured for 24 h, than the various concentration of oxymatrine (2 mmol/L, 4 mmol/L, 8 mmol/L, 15 mmol/L) were added into different experimental group cells, and 5-fluorouracil were added into the pos...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151302

    authors: Wang B,Han Q,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Biocompatibility of polysulfone II. Platelet adhesion and cho cell growth.

    abstract::Experimental results on the platelet adhesion, and CHO cell adhesion and growth onto nonionic surfactant which is composed of a long alkyl chain (n = 12-18) as the hydrophobic part, and a polyethyleneoxide (PEO) segment (n = 10-23) as the hydrophilic part coated and air-plasma treated PSf surfaces are presented in ter...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Khang G,Jeong BJ,Lee HB,Park JB

    更新日期:1995-01-01 00:00:00

  • Amount of metallic ions released from Ti-Ni alloy by abrasion in simulated bioliquids.

    abstract::The current density of Ti-56mass%Ni (Ti-50at.%) alloy after abrasion in simulated bioliquids was measured using a potentiostat to estimate the amount of metallic ions released from the alloy during repassivation and maturation. The current density in saline, saline with and without N2 bubbling, and Hanks' solutions wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Watarai M,Hanawa T,Moriyama K,Asaoka K

    更新日期:1999-01-01 00:00:00

  • Evaluation of chondrocytes expression embedded in thermoresponsive poly(amino acid)s with sol-gel transition.

    abstract::Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chueh SK,Tachibana Y,Uyama H,Kobayashi S,Tomita N

    更新日期:2007-01-01 00:00:00

  • Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    abstract::Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151427

    authors: Zhang Y,Gao Y,Li H,Teng Y,Kang Y

    更新日期:2015-01-01 00:00:00

  • Prediction model of sinoatrial node field potential using high order partial least squares.

    abstract::High order partial least squares (HOPLS) is a novel data processing method. It is highly suitable for building prediction model which has tensor input and output. The objective of this study is to build a prediction model of the relationship between sinoatrial node field potential and high glucose using HOPLS. The thr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151482

    authors: Feng Y,Cao H,Zhang Y

    更新日期:2015-01-01 00:00:00

  • Control of FES in paraplegia: modeling voluntary arm forces.

    abstract::Skilled behavior is difficult or impossible to articulate explicitly by the performers. Likewise biomechanical models of skilled motor actions are often limited by the lack of knowledge of the underlying mechanisms. A 'behavioral cloning' technique is described, based on a trained artificial neural network (ANN), that...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Andrews BJ,Davoodi R,Kamnik R,Bajd T

    更新日期:1998-01-01 00:00:00

  • Tight medial knot tying may increase retearing risk after transosseous equivalent repair of rotator cuff tendon.

    abstract:BACKGROUND:Retearing mechanism after transosseous equivalent (TOE) rotator cuff repair has not been fully clarified yet. OBJECTIVE:The purposes of this study were to compare the stress distribution pattern in the tendon stump between knotted and knotless TOE repair and to investigate the role of suture tension applied...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171673

    authors: Sano H,Tokunaga M,Noguchi M,Inawashiro T,Irie T,Abe H,Yokobori AT

    更新日期:2017-01-01 00:00:00

  • Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.

    abstract::The fretting corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium ball-and-socket-joint with tetrafluoroethylene under mechanical load. ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gil FJ,Canedo R,Padrós A,Bañeres MV,Arano JM

    更新日期:2003-01-01 00:00:00

  • Patterned layers of adsorbed extracellular matrix proteins: influence on mammalian cell adhesion.

    abstract::Three patterned systems aiming at the control of mammalian cell behavior are presented. The determinant feature common to these systems is the spatial distribution of extracellular matrix (ECM) proteins (mainly collagen) on polymer substrates. This distribution differs from one system to another with respect to the sc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dupont-Gillain CC,Alaerts JA,Dewez JL,Rouxhet PG

    更新日期:2004-01-01 00:00:00

  • The initial attachment and subsequent behavior of osteoblastic cells and oral epithelial cells on titanium.

    abstract::The interaction between implant materials and bone cells or oral epithelial (OE) cells contributes to the clinical success of dental implants. The functional activity of cells in contact with an implant is determined by its surface properties. Before cells attach, extracellular matrix (ECM) in the serum deposits on th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:

    authors: Goto T,Yoshinari M,Kobayashi S,Tanaka T

    更新日期:2004-01-01 00:00:00

  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00

  • A study of quality control method for IMRT planning based on prior knowledge and novel measures derived from both OVHs and DVHs.

    abstract::Intensity-Modulated Radiation Therapy (IMRT) mathematically forms a large-scale optimization problem. The development of an IMRT plan is computationally expensive resulting in time-consuming, inefficient, and difficult to develop high-quality IMRT plans. By combining prior knowledge with proposed novel measures derive...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141173

    authors: Zhou Z,Chen Y,Yu Z,Wang D,Zhao C,Xu J,Song W,Li B,Shen J,Zhu X

    更新日期:2014-01-01 00:00:00

  • PolyNaSS bioactivation of LARS artificial ligament promotes human ligament fibroblast colonisation in vitro.

    abstract:BACKGROUND:Introduction of a new generation of artificial ligaments for ACL reconstruction, the Ligament Augmentation and Reconstruction System (LARS), gives promising clinical results [1]. The current literature supports the use of LARS from short to medium term. To go even further to improve the biocompatibility of t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130753

    authors: Lessim S,Migonney V,Thoreux P,Lutomski D,Changotade S

    更新日期:2013-01-01 00:00:00

  • Evaluation of NiTi Superelastic Retraction Coil Springs for orthodontic tooth movement in rats.

    abstract::The purpose of this investigation was to assess mechanical properties of Superelastic Retraction Coil Springs for orthodontic use. To reach a goal, a test frame, comprising measuring force transducers was developed. To perform metallographic analyses of the nickel-titanium wire the samples of Superelastic Retraction C...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0647

    authors: Rozman J,Mrvar P,Drevenšek M,Pečlin P

    更新日期:2010-01-01 00:00:00

  • Use of enzyme-linked immunosorbent assay (ELISA) for detection and quantification of monoclonal antibodies.

    abstract::The thrust of the present work is the demonstration of the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of a monoclonal antibody human serum. The antibodies used, 7E3 and D3GP3, have been proposed as platelet receptor blockers, being directed specifically again...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Lewis G

    更新日期:1994-01-01 00:00:00