The mechanical-chemical attachment between the artificial articular cartilage (PVA-hydrogel) and metal substrate (or underlying bone).

Abstract:

:PVA-hydrogel has excellent biocompatibility as well as preferable tribological characteristics as an artificial articular cartilage. One of the most difficult problems is the attachment of PVA-hydrogel to the underlying bone (or metal substrate). In the present study, the micro-mechanical attachment between the PVA-hydrogel and metal fibre mesh was at first accomplished to obtain a composite artificial cartilage device (CACD), then the surface of fibre mesh is chemically bonded to the metal substrate (or underlying bone) by adhesive (PMMA). This method can be used to accomplish mechanical-chemical attachment between composite artificial cartilage device and underlying bone (or metal substrate). Microstructure analysis and mechanical tests indicate that the CACD can be firmly bonded to the metal substrate (or underlying bone).

journal_name

Biomed Mater Eng

authors

Gu ZQ,Xiao JM,Lou SQ

subject

Has Abstract

pub_date

1999-01-01 00:00:00

pages

347-51

issue

5-6

eissn

0959-2989

issn

1878-3619

journal_volume

9

pub_type

杂志文章
  • Hyaluronic acid as an internal phase additive to obtain ofloxacin/PLGA microsphere by double emulsion method.

    abstract::Hyaluronic acid (HA) was used as an internal phase additive to improve the loading efficiency of ofloxacin, a hydrophilic drug encapsulated by hydrophobic polylactic-co-glycolic acid (PLGA) materials, through a double emulsion (water-in-oil-in-water) solvent extraction/evaporation method. Results from laser distributi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130863

    authors: Wu G,Chen L,Li H,Wang YJ

    更新日期:2014-01-01 00:00:00

  • Interaction of collagen triple-helix with carbon nanotubes: Geometric property of rod-like molecules.

    abstract::The interactions between carbon nanotubes and important biomolecules, above all collagen molecules, have not been studied in detail. This situation is partly due to the fact that CNT are solid entities, while most of the biomolecules can be prepared in solution. We used turbidity as a means of evaluating the interacti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0557

    authors: Kuboki Y,Terada M,Kitagawa Y,Abe S,Uo M,Watari F

    更新日期:2009-01-01 00:00:00

  • Effect of hydroxyapatite sol on cell proliferation and alkaline phosphatase activity of osteoblastic MC3T3-E1 cells.

    abstract::The effect of hydroxyapatite sol (HAm) which is composed of unheating hydroxyapatite microcrystal particle on cell proliferation and alkaline phophatase activity in osteoblastic MC3T3-E1 cells, was examined in the presence or absence of fetal calfe serum (FCS) in the medium. In the absence of FCS, HAm inhibited the ce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Iwakami T,Imai T

    更新日期:2002-01-01 00:00:00

  • Enhanced oral bioavailability and antiasthmatic efficacy of curcumin using redispersible dry emulsion.

    abstract::Dry emulsion containing curcumin (DE-CUR) was prepared for oral delivery of poorly water-soluble curcumin, and its oral bioavailability and antiasthmatic efficacy was evaluated. After comparison of the solubility of curcumin in various oils, Plurol® Oleique CC497 was selected to be the oil phase due to its higher solu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130886

    authors: Jang DJ,Kim ST,Oh E,Lee K

    更新日期:2014-01-01 00:00:00

  • Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    abstract::A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Jones VC,Barton DC,Auger DD,Hardaker C,Stone MH,Fisher J

    更新日期:2001-01-01 00:00:00

  • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.

    abstract::The debris generated by the progressive wear of total joint replacement (TJR) devices is considered a primary cause of osteolysis, bone resorption, and premature failure of artificial hips and knees. The vast majority of this debris originates from the UHMWPE articulating surfaces caused by tribological interaction wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Davidson JA,Poggie RA,Mishra AK

    更新日期:1994-01-01 00:00:00

  • Multiple platelet-rich plasma preparations can solubilize freeze-dried chitosan formulations to form injectable implants for orthopedic indications.

    abstract:BACKGROUND:Platelet-rich plasma (PRP) has been used to solubilize freeze-dried chitosan (CS) formulations to form injectable implants for tissue repair. OBJECTIVE:To determine whether the in vitro performance of the formulations depends on the type of PRP preparation used to solubilize CS. METHODS:Formulations contai...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191058

    authors: Ghazi Zadeh L,Chevrier A,Lamontagne M,Buschmann MD,Hoemann CD,Lavertu M

    更新日期:2019-01-01 00:00:00

  • Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    abstract::Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151427

    authors: Zhang Y,Gao Y,Li H,Teng Y,Kang Y

    更新日期:2015-01-01 00:00:00

  • The fracture toughness characteristics of three dental composite resins.

    abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

    更新日期:1991-01-01 00:00:00

  • Selection of human p75NTR tag SNPs and its biological significance for clinical association studies.

    abstract::To select tag single nucleotide polymorphisms (SNPs) within and around human p75 neurotrophin receptor (p75NTR) gene in Chinese Han population, the sequence involving p75NTR gene as well as the upstream and downstream of the gene was identified according to the data from National Center for Biotechnology Information (...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141213

    authors: Wang YT,Lu XM,Shu YH,Xiao L,Chen KT

    更新日期:2014-01-01 00:00:00

  • A hybrid ensemble method based on double disturbance for classifying microarray data.

    abstract::Microarray data has small samples and high dimension, and it contains a significant amount of irrelevant and redundant genes. This paper proposes a hybrid ensemble method based on double disturbance to improve classification performance. Firstly, original genes are ranked through reliefF algorithm and part of the gene...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151499

    authors: Chen T,Xue H,Hong Z,Cui M,Zhao H

    更新日期:2015-01-01 00:00:00

  • Short-term human chondrocyte culturing on oriented collagen coated gelatine scaffolds for cartilage replacement.

    abstract::The biological, biochemical, mechanical, and structural properties of artificial scaffolds for tissue engineering are known to be of great importance. Therefore, in this study a hydrogel derived scaffold with biomechanical and structural properties similar to native articular cartilage was synthesized. The gelatine-ba...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zehbe R,Libera J,Gross U,Schubert H

    更新日期:2005-01-01 00:00:00

  • A novel approach for arrhythmia diagnosis: Self-adaptive and distribution-free mode.

    abstract::Arrhythmia diagnosis is very significant to ensure human health. In this paper, a new model is developed for arrhythmia diagnosis. A salient feature of the algorithm is a synergistic combination of statistical and fuzzy set-based techniques. It is distribution-free and is realized in an unsupervised mode. Arrhythmia d...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151400

    authors: Li F,Zheng D,Zhao T

    更新日期:2015-01-01 00:00:00

  • Ultrasonic velocity and attenuation measurement in kidney stones: correlation to constituents and hardness.

    abstract::In this investigation, ultrasonic parameters of kidney stones are measured, in vitro, using a double probe ultrasonic-through-transmission technique. Due to the complex chemical structure of these stones, a large variation in the values of the ultrasonic parameters is found. A correlation between ultrasonic properties...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Singh VR,Dhawan JB

    更新日期:1992-07-01 00:00:00

  • A bioelectrical impedance phase angle measuring system for assessment of nutritional status.

    abstract::Bioelectrical impedance phase angle has been recommended as a tool to assess nutrition state, but there are no measuring devices have been specially designed for hospital residents. In this study, a system was established for the measurement of bioelectrical impedance phase angle. The electrical composition, calculati...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141193

    authors: Zhang G,Huo X,Wu C,Zhang C,Duan Z

    更新日期:2014-01-01 00:00:00

  • Rapid counting method of living cells by fluorescent enzyme substrates.

    abstract::The 5(and 6)-carboxyfluorescein diacetate (C-FDA) is used for a rapid and continuous counting of living cells. Nonfluorescent C-FDA is converted into fluorescent 5(and 6)-carboxyfluorescein (C-F) by the reaction with esterase, which is an enzyme of living cells. The conversion makes it possible to count the number of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sugata K,Ohnishi T,Matsumoto K

    更新日期:1991-01-01 00:00:00

  • Studies on quantitative analysis and automatic recognition of cell types of lung cancer.

    abstract::Recognition of lung cancer cells is very important to the clinical diagnosis of lung cancer. In this paper we present a novel method to extract the structure characteristics of lung cancer cells and automatically recognize their types. Firstly soft mathematical morphology methods are used to enhance the grayscale imag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chen YC,Hu KH,Li FZ,Li SY,Su WF,Huang ZY,Hu YX

    更新日期:2006-01-01 00:00:00

  • Does artificial aging correctly predict the long-term in-vivo degradation behavior in zirconia hip prostheses?

    abstract:BACKGROUND:Accelerated hydrothermal aging has long been one of the most widely accepted quality control tests for simulating low-temperature degradation (LTD) in zirconia-containing implants used in total hip arthroplasty (THA). However, it is still unclear how much consistency there is between the experimental predict...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201083

    authors: Tateiwa T,Takahashi Y,Pezzotti G,Shishido T,Masaoka T,Sano K,Yamamoto K

    更新日期:2020-01-01 00:00:00

  • Phosphorylated chitin increased bone formation when implanted into rat calvaria with the Ti-device.

    abstract:BACKGROUND:Previously we found that a group of phosphorylated proteins (SIBLINGs) in bone binds with the Ti-device, and increases the early bone formation around the Ti-implants remarkably. From these results, we explained the biochemical mechanism of a strong bond between living bone and Ti, which was discovered by Br...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201079

    authors: Song Q,Yagami K,Furusawa T,Takita H,Kurasaki M,Tokura S,Morimoto K,Sammons R,Iku S,Kuboki Y

    更新日期:2020-01-01 00:00:00

  • Aligned polyvinylpyrrolidone nanofibers with advanced electrospinning for biomedical applications.

    abstract:BACKGROUND:Electrospinning is a highly effective method in order to generate nano-scaled fibers. In conventional electrospinning technique, geometry of nanofibers are mostly random due to the chaotic behavior of polymer jet. OBJECTIVE:Purpose of this study is to produce aligned nanofibers from PVP polymers with advanc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181017

    authors: Karayeğen G,Koçum IC,Çökeli Ler Serdaroğlu D,Doğan M

    更新日期:2018-01-01 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Improved bond performance of a dental adhesive system using nano-technology.

    abstract::Since adhesive technology was introduced into dental field, metal-based restoration has been gradually replaced by metal-free restoration. Using the adhesive technology, minimum invasive technique has been possible in daily clinical practice as well as esthetic tooth-colored restorations have become very popular all o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-2009-0587

    authors: Nagano F,Selimovic D,Noda M,Ikeda T,Tanaka T,Miyamoto Y,Koshiro K,Sano H

    更新日期:2009-01-01 00:00:00

  • Reliability of the portable gait rhythmogram in post-stroke patients.

    abstract:BACKGROUND:Gait analysis, such as portable gait rhythmogram (PGR), provides objective information that helps in the quantitative evaluation of human locomotion. OBJECTIVE:The purpose of this study was to assess the reliability of PGR in post-stroke patients. METHODS:Two raters (A and B) examined 48 post-stroke patien...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-206007

    authors: Miyata R,Matsumoto S,Miura S,Kawamura K,Uema T,Miyara K,Niibo A,Hoei T,Ogura T,Shimodozono M

    更新日期:2020-01-01 00:00:00

  • Control of FES in paraplegia: modeling voluntary arm forces.

    abstract::Skilled behavior is difficult or impossible to articulate explicitly by the performers. Likewise biomechanical models of skilled motor actions are often limited by the lack of knowledge of the underlying mechanisms. A 'behavioral cloning' technique is described, based on a trained artificial neural network (ANN), that...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Andrews BJ,Davoodi R,Kamnik R,Bajd T

    更新日期:1998-01-01 00:00:00

  • Biodegradable/biocompatible coated metal implants for orthopedic applications.

    abstract::Biocompatible metals have been suggested as revolutionary biomaterials for bone-grafting therapies. Although metals and their alloys are widely and successfully used in producing biomedical implants due to their good mechanical properties and corrosion resistance, they have a lack in bioactivity. Therefore coating of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-161568

    authors: Saleh MM,Touny AH,Al-Omair MA,Saleh MM

    更新日期:2016-05-12 00:00:00

  • Reinforcement of acrylic resins for provisional fixed restorations. Part III: effects of addition of titania and zirconia mixtures on some mechanical and physical properties.

    abstract::Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems assoc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Panyayong W,Oshida Y,Andres CJ,Barco TM,Brown DT,Hovijitra S

    更新日期:2002-01-01 00:00:00

  • Effects of hydrogen sulfide on myocardial fibrosis in diabetic rats: Changes in matrix metalloproteinases parameters.

    abstract::In order to explore the effects of hydrogen sulfide (H2S) on myocardial fibrosis in diabetic rats and its underlying mechanisms, intraperitoneal injections of streptozotocin were used to establish the diabetes models and sodium hydrosulfide (NaHS) was used as an exogenous donor of H2S. Eight weeks later, Van Gieson st...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151508

    authors: Xiao T,Zeng O,Luo J,Wu Z,Li F,Yang J

    更新日期:2015-01-01 00:00:00

  • A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent.

    abstract:BACKGROUND:Stenting has been proposed as an effective treatment to restore blood flow in obstructed arteries by plaques. Although several modified designs for stents have been suggested, most designs have the risk of disturbing blood flow. OBJECTIVE:The main objective is to propose a stent design to attain a uniform l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171691

    authors: Beigzadeh B,Mirmohammadi SA,Ayatollahi MR

    更新日期:2017-01-01 00:00:00

  • An experimental study on the biomechanical properties of the cancellous bones of distal femur.

    abstract:OBJECTIVE:To study the comprehensive biomechanical properties of the cancellous bone of distal femur through a series of mechanical tests, and provide relevant subjects with the basic technical data. BACKGROUND:The study on bone mechanics is a commonly used approach to evaluate the biomechanical competency of bone. Th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du C,Ma H,Ruo M,Zhang Z,Yu X,Zeng Y

    更新日期:2006-01-01 00:00:00

  • Microencapsulated rBMMSCs/calcium phosphate cement for bone formation in vivo.

    abstract::As an injectable scaffold material for bone tissue engineering, calcium phosphate cement (CPC) has good biocompatibility, self-setting, and osteoconduction properties. Alginate-microencapsulated seed cells can pick up the degradation speed and bioactivity of CPC. The aim of this study was to explore the osteogenic abi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130875

    authors: Wang J,Qiao P,Dong L,Li F,Xu T,Xie Q

    更新日期:2014-01-01 00:00:00