Aligned polyvinylpyrrolidone nanofibers with advanced electrospinning for biomedical applications.

Abstract:

BACKGROUND:Electrospinning is a highly effective method in order to generate nano-scaled fibers. In conventional electrospinning technique, geometry of nanofibers are mostly random due to the chaotic behavior of polymer jet. OBJECTIVE:Purpose of this study is to produce aligned nanofibers from PVP polymers with advanced electrospinning technique in order to be used in a potential novel sensor applications, tissue regeneration and engineering. METHODS:In this study, by using finite hollow cylinder focusing electrodes, an external electrostatic field is created. With these electrodes, it is aimed to decrease whipping instability of polymer jet. In addition, it is also investigated that the alignment ratio of nanofibers by using conductive parallel electrodes which placed through jet trajectory. RESULTS:In conclusion, with the effect of electrical field created by cylinder electrodes, radius of the fiber dispersion on the collector was able to be reduced and aligned nanofibers were successfully produced by using electrical field generated from the parallel plates. CONCLUSIONS:Radius of the fiber dispersion on the collector is 9.95 mm and fiber diameters varied between 800 nm and 3 μm. Additionally, alignment ratio of the fibers is determined with ImageJ software. These alignment of nanofibers can be used in tissue engineering applications and sensor applications.

journal_name

Biomed Mater Eng

authors

Karayeğen G,Koçum IC,Çökeli Ler Serdaroğlu D,Doğan M

doi

10.3233/BME-181017

subject

Has Abstract

pub_date

2018-01-01 00:00:00

pages

685-697

issue

5

eissn

0959-2989

issn

1878-3619

pii

BME181017

journal_volume

29

pub_type

杂志文章
  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00

  • Injectable CMC/PEI gel as an in vivo scaffold for demineralized bone matrix.

    abstract::A number of materials have been considered as sources of grafts to repair bone defects. Here, we examined the possibility of creating in situ-forming gels from sodium carboxymethylcellulose (CMC) and poly(ethyleneimine) (PEI) for use as an in vivo carrier of demineralized bone matrix (DBM). The interaction between ani...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0603

    authors: Kim KS,Kang YM,Lee JY,Kim ES,Kim CH,Min BH,Lee HB,Kim JH,Kim MS

    更新日期:2009-01-01 00:00:00

  • Age-related alterations in TGF beta signaling as a causal factor of cartilage degeneration in osteoarthritis.

    abstract:BACKGROUND:Age is the most important risk factor for primary osteoarthritis (OA). Members of the TGF-β superfamily play a crucial role in chondrocyte differentiation and maintenance of healthy articular cartilage. OBJECTIVE:We have investigated whether age-related changes in TGF-β superfamily signaling components play...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140976

    authors: van der Kraan PM

    更新日期:2014-01-01 00:00:00

  • Studies on quantitative analysis and automatic recognition of cell types of lung cancer.

    abstract::Recognition of lung cancer cells is very important to the clinical diagnosis of lung cancer. In this paper we present a novel method to extract the structure characteristics of lung cancer cells and automatically recognize their types. Firstly soft mathematical morphology methods are used to enhance the grayscale imag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chen YC,Hu KH,Li FZ,Li SY,Su WF,Huang ZY,Hu YX

    更新日期:2006-01-01 00:00:00

  • pH-responsive mesoporous silica nanocarriers based on layer-by-layer self-assembly.

    abstract::Significant progress has been achieved in the field of pH-sensitive drug delivery system in recent years. For layer-by-layer self-assembly nanocarriers, various pH values can induce the change of permeability and structural stability of the outer polyelectrolyte multi-layers, resulting in the release of the loaded dru...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141033

    authors: Zhang HY,Sun YF,Sun YL,Zhou M

    更新日期:2014-01-01 00:00:00

  • Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis.

    abstract:BACKGROUND:The simulated Doppler blood flow signals are widely used to assess the performance of the clutter filters for removing wall components while reserving low-velocity signals scattered from physiological blood flow approaching the inner vessel-wall injured by a stenosed lesion. OBJECTIVE:By simultaneously taki...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161573

    authors: Gao L,Zhang Y,Zhou Y,Hu X,Deng L,Zhang K,Cai G,Zhang J

    更新日期:2016-08-12 00:00:00

  • The in vitro and in vivo indomethacin release from self-setting bioactive glass bone cement.

    abstract::The in vivo and in vitro drug release profiles from a self-setting bioactive CaO-SiO2-P2O5 glass bone cement containing indomethacin as a model drug were investigated. The cement containing 2% and 5% indomethacin (IMC) powder hardened within 5 min after mixing with ammonium phosphate buffer. After setting, in vitro dr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Otsuka M,Nakahigashi Y,Matsuda Y,Kokubo T,Yoshihara S,Fujita H,Nakamura T

    更新日期:1997-01-01 00:00:00

  • Reinforcement of acrylic resins for provisional fixed restorations. Part III: effects of addition of titania and zirconia mixtures on some mechanical and physical properties.

    abstract::Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems assoc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Panyayong W,Oshida Y,Andres CJ,Barco TM,Brown DT,Hovijitra S

    更新日期:2002-01-01 00:00:00

  • Mechanical behavior of quartz fiber reinforced epoxy resins for teeth restoration.

    abstract::In this work composite materials, based on quartz fibers and epoxy resins, were employed with the aim to restore damaged teeth. The composite materials were chosen because they show biomechanical features very similar to that of the dentine, the main constituent of the tooth. Extracted teeth were rebuilt with two diff...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Visco AM,Calabrese L,Campo N,Torrisi L,Oteri G,Lo Giudice G,Cicciù D

    更新日期:2006-01-01 00:00:00

  • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.

    abstract::The debris generated by the progressive wear of total joint replacement (TJR) devices is considered a primary cause of osteolysis, bone resorption, and premature failure of artificial hips and knees. The vast majority of this debris originates from the UHMWPE articulating surfaces caused by tribological interaction wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Davidson JA,Poggie RA,Mishra AK

    更新日期:1994-01-01 00:00:00

  • A study of quality control method for IMRT planning based on prior knowledge and novel measures derived from both OVHs and DVHs.

    abstract::Intensity-Modulated Radiation Therapy (IMRT) mathematically forms a large-scale optimization problem. The development of an IMRT plan is computationally expensive resulting in time-consuming, inefficient, and difficult to develop high-quality IMRT plans. By combining prior knowledge with proposed novel measures derive...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141173

    authors: Zhou Z,Chen Y,Yu Z,Wang D,Zhao C,Xu J,Song W,Li B,Shen J,Zhu X

    更新日期:2014-01-01 00:00:00

  • Phosphorylated chitin increased bone formation when implanted into rat calvaria with the Ti-device.

    abstract:BACKGROUND:Previously we found that a group of phosphorylated proteins (SIBLINGs) in bone binds with the Ti-device, and increases the early bone formation around the Ti-implants remarkably. From these results, we explained the biochemical mechanism of a strong bond between living bone and Ti, which was discovered by Br...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201079

    authors: Song Q,Yagami K,Furusawa T,Takita H,Kurasaki M,Tokura S,Morimoto K,Sammons R,Iku S,Kuboki Y

    更新日期:2020-01-01 00:00:00

  • Push-out strength of hydroxyapatite coated by sputtering technique in bone.

    abstract::Hydroxyapatite was coated with 1 microm thickness on titanium columns of a length of 10 mm, an outer diameter of 4.0 mm by radio frequency magnetron sputtering. The hydroxyapatite coating titanium columns were implanted in the diaphysis of femora of 3 adult dogs, and push-out test was carried out after 2, 4 and 12 wee...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Nishimura I,Fukui Y

    更新日期:2001-01-01 00:00:00

  • Assessment of the nanostructure of acid-base resistant zone by the application of all-in-one adhesive systems: Super dentin formation.

    abstract::An acid-base resistant zone (ABRZ) has been shown to be created under a hybrid layer in a self-etching adhesive system at the adhesive/dentin interface. The purpose of this study was to assess the nanostructure of the ABRZ by applying all-in-one adhesive systems. Human premolar dentin was treated with one of two all-i...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0576

    authors: Nikaido T,Weerasinghe DD,Waidyasekera K,Inoue G,Foxton RM,Tagami J

    更新日期:2009-01-01 00:00:00

  • Ultrathin polymer monolayers for promotion of cell growth on bioprosthetic materials -- evolution of a new concept to improve long term performance of biologic heart vales.

    abstract::Reoperation of aldehyde tanned bioprotheses due to calcific degeneration remains their major drawback. Based on experiments studying mechanisms and factors that influence the time phase, extent and progression of calcification and evaluating the efficiency of anticalcification treatments and the effects of surface see...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dahm M,Rühe J,Berchthold B,Prüfer D,Prucker O,Chang BJ,Wallrath A,Oelert H

    更新日期:2004-01-01 00:00:00

  • Real-time 3D visual tracking of laparoscopic instruments for robotized endoscope holder.

    abstract::Robotized endoscope holder in laparoscopic surgeries allows surgeons to control the endoscope without the assistants' intervention. In this paper, a new method is proposed for the automatic 3D-tracking of laparoscopic instruments in real-time to provide more convenient interactions between surgeons and the robotized e...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141083

    authors: Zhao Z

    更新日期:2014-01-01 00:00:00

  • Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    abstract::A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130811

    authors: Yu CH,Piao YJ,Kim K,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Controlled release bevacizumab in thermoresponsive hydrogel found to inhibit angiogenesis.

    abstract::Age-related macular degeneration (ARMD) and intraocular neovascular diseases have been treated clinically by anti-VEGF antibody drug bevacizumab. However, the use of bevacizumab in the treatment of retinal neovascular diseases has been limited due to the short half-life and frequent injections. In this research, novel...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141003

    authors: Hu CC,Chaw JR,Chen CF,Liu HW

    更新日期:2014-01-01 00:00:00

  • A bioelectrical impedance phase angle measuring system for assessment of nutritional status.

    abstract::Bioelectrical impedance phase angle has been recommended as a tool to assess nutrition state, but there are no measuring devices have been specially designed for hospital residents. In this study, a system was established for the measurement of bioelectrical impedance phase angle. The electrical composition, calculati...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141193

    authors: Zhang G,Huo X,Wu C,Zhang C,Duan Z

    更新日期:2014-01-01 00:00:00

  • Analysis of basal physical fitness and lumbar muscle function according to indoor horse riding exercise.

    abstract::The aim of this study is to verify the effect of indoor horse riding exercise on basal physical exercise and lumbar muscular function. The subjects included were 20 healthy females, who participated in the horse riding exercise using SRider (Rider Co. & ChonbuK National Univ, Korea) for 30 minutes per day, 3 days per ...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-141053

    authors: Yu CH,Hong CU,Kang SR,Kwon TK

    更新日期:2014-01-01 00:00:00

  • A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent.

    abstract:BACKGROUND:Stenting has been proposed as an effective treatment to restore blood flow in obstructed arteries by plaques. Although several modified designs for stents have been suggested, most designs have the risk of disturbing blood flow. OBJECTIVE:The main objective is to propose a stent design to attain a uniform l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171691

    authors: Beigzadeh B,Mirmohammadi SA,Ayatollahi MR

    更新日期:2017-01-01 00:00:00

  • Polishing of dental porcelain by polycrystalline diamond.

    abstract::Polycrystalline diamond (PCD) exhibits excellent abrasive characteristics and is commonly used as loose grains for precision machining of hard ceramics and other materials that are difficult to grind and polish. In the present study, we investigated using bonded PCD for polishing dental porcelain, for which a lustrous...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0642

    authors: Nakamura Y,Sato H,Ohtsuka M,Hojo S

    更新日期:2010-01-01 00:00:00

  • Theoretical foundation on a noninvasive estimation for viscoelastic mechanical property of blood vessels by ultrasonic Doppler effect.

    abstract::The method used in this paper is developed to estimate the degree of viscoelasticity of the blood vessel wall in a noninvasive mechanical method. In this proposed method, we can obtain an output waveform connected with mechanical behavior of blood vessels by using Ultrasonic Doppler Effect Sensory (UDES). Characterizi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Yoshinari H,Yokobori AT Jr,Ohkuma T

    更新日期:1994-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • SIFT algorithm-based 3D pose estimation of femur.

    abstract::To address the lack of 3D space information in the digital radiography of a patient femur, a pose estimation method based on 2D-3D rigid registration is proposed in this study. The method uses two digital radiography images to realize the preoperative 3D visualization of a fractured femur. Compared with the pure Digit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141103

    authors: Zhang X,Zhu Y,Li C,Zhao J,Li G

    更新日期:2014-01-01 00:00:00

  • Design of a quasi-passive 3 DOFs ankle-foot wearable rehabilitation orthosis.

    abstract::Muscular rigidity and atrophy caused by long-term underactivity usually lead to foot drop, strephenopodia, foot extorsion or some other complications for the lower limb movement disorders or lower limb surgery sufferers. The ankle-foot orthosis can help patients conduct the right ankle motion mode training, inhibit sp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151356

    authors: Zhang C,Zhu Y,Fan J,Zhao J,Yu H

    更新日期:2015-01-01 00:00:00

  • In vitro evaluation of a multifunctional nano drug delivery system based on tigecycline-loaded calcium-phosphate/ poly-DL-lactide-co-glycolide.

    abstract::Most drug delivery systems as treatment modalities for osteomyelitis have not been evaluated for resistant infections. Tigecycline (TG) is an antimicrobial agent that could be used in the treatment of multi-drug-resistant orthopedic infections. The objective of this in vitro study has been to determine what dosage of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140978

    authors: Ignjatović NL,Ninkov P,Sabetrasekh R,Lyngstadaas SP,Uskoković DP

    更新日期:2014-01-01 00:00:00

  • The fracture toughness characteristics of three dental composite resins.

    abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

    更新日期:1991-01-01 00:00:00

  • Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.

    abstract::The fretting corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium ball-and-socket-joint with tetrafluoroethylene under mechanical load. ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gil FJ,Canedo R,Padrós A,Bañeres MV,Arano JM

    更新日期:2003-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00