pH-responsive mesoporous silica nanocarriers based on layer-by-layer self-assembly.

Abstract:

:Significant progress has been achieved in the field of pH-sensitive drug delivery system in recent years. For layer-by-layer self-assembly nanocarriers, various pH values can induce the change of permeability and structural stability of the outer polyelectrolyte multi-layers, resulting in the release of the loaded drug. In the present study, carboxyl-modified mesoporous silica nanoparticles (MSNs-COOH) were prepared as reservoirs to hold model cargo, i.e. Rhodamine B (RhB). Polycations, including 1, 4-butanediamine (BDA)-modified linear poly (glycerol methacrylate) (L-B) or BDA-modified star-shaped poly (glycerol methacrylate) (S5-B) and 1,2-ethanediamine (EDA)-modified star-shaped poly (glycerol methacrylate) (S5-E), and polyanion, i.e. poly (acrylic acid) (PAA), are self-assembled by electrostatic interactions as coating. The loading process of RhB was characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, thermo-gravimetric analysis, and dynamic light scattering, and the release of RhB was controlled by changing the pH of phosphate buffer saline. The results showed that the loading capacity and entrapment efficiency of RhB were the highest for S5-B/PAA, which were 10.1% and 44.4%, respectively. In addition, the release of RhB was about 90% at pH 2.0 and 35% at pH 7.4, which was indicative of obvious pH-responsivity. The MSNs-COOH coated by S5-B/PAA proposed in the present study show potential applications in targeted drug delivery.

journal_name

Biomed Mater Eng

authors

Zhang HY,Sun YF,Sun YL,Zhou M

doi

10.3233/BME-141033

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

2211-8

issue

6

eissn

0959-2989

issn

1878-3619

pii

X6806641J0706867

journal_volume

24

pub_type

杂志文章
  • Polishing of dental porcelain by polycrystalline diamond.

    abstract::Polycrystalline diamond (PCD) exhibits excellent abrasive characteristics and is commonly used as loose grains for precision machining of hard ceramics and other materials that are difficult to grind and polish. In the present study, we investigated using bonded PCD for polishing dental porcelain, for which a lustrous...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0642

    authors: Nakamura Y,Sato H,Ohtsuka M,Hojo S

    更新日期:2010-01-01 00:00:00

  • Bioshell calcium oxide (BiSCaO) for cleansing and healing Pseudomonas aeruginosa-infected wounds in hairless rats.

    abstract:BACKGROUND:Scallop shell powder is called bioshell calcium oxide (BiSCaO), which is known to possess deodorizing properties and broad antimicrobial activity against various pathogenic microbes, including viruses, bacteria, spores, and fungi. OBJECTIVE:This study aims to investigate the applications of BiSCaO suspensio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201082

    authors: Takayama T,Ishihara M,Sato Y,Nakamura S,Fukuda K,Murakami K,Yokoe H

    更新日期:2020-01-01 00:00:00

  • Controlled release bevacizumab in thermoresponsive hydrogel found to inhibit angiogenesis.

    abstract::Age-related macular degeneration (ARMD) and intraocular neovascular diseases have been treated clinically by anti-VEGF antibody drug bevacizumab. However, the use of bevacizumab in the treatment of retinal neovascular diseases has been limited due to the short half-life and frequent injections. In this research, novel...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141003

    authors: Hu CC,Chaw JR,Chen CF,Liu HW

    更新日期:2014-01-01 00:00:00

  • Individual tooth region segmentation using modified watershed algorithm with morphological characteristic.

    abstract::In this paper, a new method for individual tooth segmentation was proposed. The proposed method is composed of enhancement and extraction of boundary and seed of watershed algorithm using trisection areas by morphological characteristic of teeth. The watershed algorithm is one of the conventional methods for tooth seg...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141153

    authors: Na SD,Lee G,Lee JH,Kim MN

    更新日期:2014-01-01 00:00:00

  • Computer-aided detection of lung nodules using outer surface features.

    abstract::In this study, a computer-aided detection (CAD) system was developed for the detection of lung nodules in computed tomography images. The CAD system consists of four phases, including two-dimensional and three-dimensional preprocessing phases. In the feature extraction phase, four different groups of features are extr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151418

    authors: Demir Ö,Yılmaz Çamurcu A

    更新日期:2015-01-01 00:00:00

  • The fracture toughness characteristics of three dental composite resins.

    abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

    更新日期:1991-01-01 00:00:00

  • Microencapsulated rBMMSCs/calcium phosphate cement for bone formation in vivo.

    abstract::As an injectable scaffold material for bone tissue engineering, calcium phosphate cement (CPC) has good biocompatibility, self-setting, and osteoconduction properties. Alginate-microencapsulated seed cells can pick up the degradation speed and bioactivity of CPC. The aim of this study was to explore the osteogenic abi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130875

    authors: Wang J,Qiao P,Dong L,Li F,Xu T,Xie Q

    更新日期:2014-01-01 00:00:00

  • Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.

    abstract::The present review surveys studies on physical-chemical properties and biological response of living tissues to NiTi (Nitinol) carried out recently, aiming at an understanding of the place of this material among the implant alloys in use. Advantages of shape memory and superelasticity are analyzed in respect to functi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:

    authors: Shabalovskaya SA

    更新日期:2002-01-01 00:00:00

  • A study of load cycling in a NiTi shape memory alloy with pseudoelastic behaviour used in dental prosthetic fixators.

    abstract::NiTi alloy used in dental prosthetic fixators shows pseudoelastic behaviour and exhibits a great potential in dental and orthopaedic applications where constant correcting loads are required. In order to use such materials in dental prosthetic fixators, where the device is cyclically deformed, it is necessary to inves...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sabrià J,Cortada M,Giner L,Gil FJ,Fernández E,Manero JM,Planell JA

    更新日期:1996-01-01 00:00:00

  • Different effects of nanophase and conventional hydroxyapatite thin films on attachment, proliferation and osteogenic differentiation of bone marrow derived mesenchymal stem cells.

    abstract:UNLABELLED:It is suggested that nanophase hydroxyapatite (nHAP) might have advantages over conventional hydroxyapatite (cHAP) as a biomaterial for bone regeneration. To be a satisfactory candidate for bone tissue engineering, it is important to support the growth and differentiation of bone marrow-derived mesenchymal s...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zhou GS,Su ZY,Cai YR,Liu YK,Dai LC,Tang RK,Zhang M

    更新日期:2007-01-01 00:00:00

  • The mechanical-chemical attachment between the artificial articular cartilage (PVA-hydrogel) and metal substrate (or underlying bone).

    abstract::PVA-hydrogel has excellent biocompatibility as well as preferable tribological characteristics as an artificial articular cartilage. One of the most difficult problems is the attachment of PVA-hydrogel to the underlying bone (or metal substrate). In the present study, the micro-mechanical attachment between the PVA-hy...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gu ZQ,Xiao JM,Lou SQ

    更新日期:1999-01-01 00:00:00

  • Investigation of mechanical compatibility of hernia meshes and human abdominal fascia.

    abstract:OBJECTIVE:Understanding the biomechanical properties of hernia meshes is essential in facilitating their selection. The aim of this study was to evaluate the mechanical compatibility of hernia meshes and human abdominal fascia and assess their applicability in hernia repair. METHODS:Uniaxial tensile tests were perform...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171719

    authors: Doneva M,Pashkouleva D

    更新日期:2018-01-01 00:00:00

  • The influence of Zn on the deposition of HA on sol-gel derived bioactive glass.

    abstract::To evaluate the influence of Zn on the formation of hydroxyapatite (HA), zinc-containing glass 58S4Z was prepared by substitution of CaO with 4 wt% ZnO in 58S bioactive glass, and Zn-containing simulated body fluid (ZnSBF) was prepared as soaking fluid. During the soaking, all samples could induce the deposition of HA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du RL,Chang J

    更新日期:2006-01-01 00:00:00

  • Degradable/non-degradable polymer composites for in-situ tissue engineering small diameter vascular prosthesis application.

    abstract::Various tissue-engineered vascular grafts have been studied in order to overcome the clinical disadvantages associated with conventional prostheses. However, previous tissue-engineered vascular grafts have possessed insufficient mechanical properties and thus have generally required either preoperative cellular manipu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141023

    authors: Wang F,Mohammed A,Li C,Ge P,Wang L,King MW

    更新日期:2014-01-01 00:00:00

  • Nonholonomic mobile system control by combining EEG-based BCI with ANFIS.

    abstract::Motor imagery EEG-based BCI has advantages in the assistance of human control of peripheral devices, such as the mobile robot or wheelchair, because the subject is not exposed to any stimulation and suffers no risk of fatigue. However, the intensive training necessary to recognize the numerous classes of data makes it...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151409

    authors: Yu W,Feng H,Feng Y,Madani K,Sabourin C

    更新日期:2015-01-01 00:00:00

  • Improved bond performance of a dental adhesive system using nano-technology.

    abstract::Since adhesive technology was introduced into dental field, metal-based restoration has been gradually replaced by metal-free restoration. Using the adhesive technology, minimum invasive technique has been possible in daily clinical practice as well as esthetic tooth-colored restorations have become very popular all o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-2009-0587

    authors: Nagano F,Selimovic D,Noda M,Ikeda T,Tanaka T,Miyamoto Y,Koshiro K,Sano H

    更新日期:2009-01-01 00:00:00

  • A comparison study on the flexural strength and compressive strength of four resin-modified luting glass ionomer cements.

    abstract::The purpose of this study is to compare the differences in flexural strength and compressive strength between four resin-modified luting glass ionomer cements that are commonly used in clinics. Furthermore, this study investigates the influence of curing mode on the flexural strength and compressive strength of dual-c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151284

    authors: Li Y,Lin H,Zheng G,Zhang X,Xu Y

    更新日期:2015-01-01 00:00:00

  • Evaluation of corrosion resistance and surface characteristics of orthodontic wires immersed in different mouthwashes.

    abstract:BACKGROUND:Patients use mouthwashes in addition to mechanical cleaning during orthodontic treatment. The effects of mouthwashes on the archwires have not been examined yet. OBJECTIVE:To compare the corrosion resistance of four different arch wires and corrosion effects of different mouthwashes to formulate a biocompat...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161607

    authors: Nalbantgil D,Ulkur F,Kardas G,Culha M

    更新日期:2016-11-25 00:00:00

  • An improved finite element modeling of the cerebrospinal fluid layer in the head impact analysis.

    abstract::The finite element (FE) method has been widely used to investigate the mechanism of traumatic brain injuries (TBIs), because it is technically difficult to quantify the responses of the brain tissues to the impact in experiments. One of technical challenges to build a FE model of a human head is the modeling of the ce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171666

    authors: Wu JZ,Pan CS,Wimer BM,Rosen CL

    更新日期:2017-01-01 00:00:00

  • New clinical failure mode triggered by a new coronary stent design.

    abstract::Longitudinal stent compression (LSC) is a new failure mode not previously observed in coronary stents. This phenomenon occurs when the physician tries to cross the deployed stent with other devices. While this phenomenon has been observed with a number of stent designs, it seems more common with the Element stent. A c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130781

    authors: Hsiao HM,Yeh CT,Chiu YH,Wang C,Chen CP

    更新日期:2014-01-01 00:00:00

  • Nondestructive analysis of dielectric properties: application to ion beam irradiated tissue response microfibre.

    abstract::The aim of this work was to investigate the effect of 2.4 MeV proton irradiation on the dielectric property of polyethylene terephthalate (PET) microfibre nondestructively. The dielectric constant εd of single-microfibre has been measured as-such applying laser diffraction technique. Applying this methodology εd is fo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130947

    authors: Mallick B

    更新日期:2014-01-01 00:00:00

  • Short-term human chondrocyte culturing on oriented collagen coated gelatine scaffolds for cartilage replacement.

    abstract::The biological, biochemical, mechanical, and structural properties of artificial scaffolds for tissue engineering are known to be of great importance. Therefore, in this study a hydrogel derived scaffold with biomechanical and structural properties similar to native articular cartilage was synthesized. The gelatine-ba...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zehbe R,Libera J,Gross U,Schubert H

    更新日期:2005-01-01 00:00:00

  • Thermomechanical analysis of shape memory devices.

    abstract::Shape memory alloys (SMA) are being increasingly used in various industrial applications as actuators, connectors, or damping materials. In the medical field, superelastic devices such as eyeglass frames, stents or guide catheters have come to market in the recent years. The design of SMA devices has usually been base...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Trochu F,Brailovski V,Meunier MA,Terriault P,Qian YY

    更新日期:1996-01-01 00:00:00

  • A novel approach for arrhythmia diagnosis: Self-adaptive and distribution-free mode.

    abstract::Arrhythmia diagnosis is very significant to ensure human health. In this paper, a new model is developed for arrhythmia diagnosis. A salient feature of the algorithm is a synergistic combination of statistical and fuzzy set-based techniques. It is distribution-free and is realized in an unsupervised mode. Arrhythmia d...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151400

    authors: Li F,Zheng D,Zhao T

    更新日期:2015-01-01 00:00:00

  • Automatic quantitative analysis of bipolysaccharide liposome by image processing method.

    abstract::This paper established the extracting method and algorithm for liposome images on the basis of analyzing the form feature of liposome, and its corresponding automatic analysis software. Some algorithms, such as the logical algorithms of mathematical morphology, the grayscale-gradient co-occurrence matrix-based method ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Haitao X,Kuanghu H,Wanfang S,Shuyu L,Desen S

    更新日期:2002-01-01 00:00:00

  • A study on reference standard for cytotoxicity assay of biomaterials.

    abstract::The objective of the present study was to find a standard substance for use as a reference in the cytotoxicity assay of biomaterials, as an alternative to animal experiments in recent years. Eight kinds of rubber were made in a plate shape to keep their surface area at 1 cm2 against 10 ml of extract volume. They were ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshima H,Nakamura M

    更新日期:1994-01-01 00:00:00

  • Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.

    abstract::The fretting corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium ball-and-socket-joint with tetrafluoroethylene under mechanical load. ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gil FJ,Canedo R,Padrós A,Bañeres MV,Arano JM

    更新日期:2003-01-01 00:00:00

  • Development of SPR biosensor for simultaneous detection of multiplex respiratory viruses.

    abstract::A surface plasmon resonance (SPR)-based biosensor was developed for specific detection of nine common respiratory virus, including influenza A and influenza B, H1N1, respiratory syncytial virus (RSV), parainfluenza virus 1-3 (PIV1, 2, 3), adenovirus, and severe acute respiratory syndrome coronavirus (SARS). The SPR bi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151526

    authors: Shi L,Sun Q,He J,Xu H,Liu C,Zhao C,Xu Y,Wu C,Xiang J,Gu D,Long J,Lan H

    更新日期:2015-01-01 00:00:00

  • Failures of yttria-stabilised tetragonal zirconia: 52 retrieved ceramic femoral heads of total hip prostheses.

    abstract::Fifty two ceramic femoral heads have been investigated after implantation. All heads had articulated against ultra high molecular weight polyethylene (UHMWPE) cups. Examination of the heads shows changes in sphericity and surface roughness due to the wear. The behaviour of these retrieved heads after clinical use conf...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Fernández-Fairén M,Sala P,Gil FJ

    更新日期:2006-01-01 00:00:00

  • The dynein-triggered ciliary motion in embryonic nodes: an exploratory study based on computational models.

    abstract::The cilia, presenting a rotational movement in the embryonic nodes, play a crucial role in the left-right specification during embryogenesis. The characteristic architecture of these cilia is based on a cylindrical arrangement of 9 doublet microtubules and the motion of the cilia is triggered by the dynein motors loca...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141063

    authors: Chen D,Zhong Y,Shinohara K,Nishida T,Hasegawa T,Hamada H

    更新日期:2014-01-01 00:00:00