Thermomechanical analysis of shape memory devices.

Abstract:

:Shape memory alloys (SMA) are being increasingly used in various industrial applications as actuators, connectors, or damping materials. In the medical field, superelastic devices such as eyeglass frames, stents or guide catheters have come to market in the recent years. The design of SMA devices has usually been based on trial and error, since until recently no general simulation model was available to assist application engineers. The purpose of this article is to describe the computational methodology developed, validated and used for several industrial projects at Ecole Polytechnique of Montréal to simulate the thermomechanical behavior of shape memory materials. This new approach includes three main stages: experimental characterization, construction of a nonlinear material law based on dual kriging interpolation and finally, calculation of the thermomechanical response of SMA devices. For complex geometry, finite element analysis is used, but for simple devices such as springs or electrically activated SMA wires, simplified calculation methods are satisfactory. Validation results recently obtained will also be presented, and examples of industrial applications briefly reviewed.

journal_name

Biomed Mater Eng

authors

Trochu F,Brailovski V,Meunier MA,Terriault P,Qian YY

subject

Has Abstract

pub_date

1996-01-01 00:00:00

pages

389-403

issue

6

eissn

0959-2989

issn

1878-3619

journal_volume

6

pub_type

杂志文章
  • Automatic quantitative analysis of bipolysaccharide liposome by image processing method.

    abstract::This paper established the extracting method and algorithm for liposome images on the basis of analyzing the form feature of liposome, and its corresponding automatic analysis software. Some algorithms, such as the logical algorithms of mathematical morphology, the grayscale-gradient co-occurrence matrix-based method ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Haitao X,Kuanghu H,Wanfang S,Shuyu L,Desen S

    更新日期:2002-01-01 00:00:00

  • A statistical approach to segmentation of diffusion tensor imaging.

    abstract::The aim of this study is to design a statistical segmentation technique to allow extraction of grey matter, white matter and cerebral spinal fluid volumes from diffusion tensor imaging. Four channel maps of the DTI are used as the input features, which provide more information for brain tissue segmentation compared wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130927

    authors: Wen Y,He L

    更新日期:2014-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00

  • Multiple platelet-rich plasma preparations can solubilize freeze-dried chitosan formulations to form injectable implants for orthopedic indications.

    abstract:BACKGROUND:Platelet-rich plasma (PRP) has been used to solubilize freeze-dried chitosan (CS) formulations to form injectable implants for tissue repair. OBJECTIVE:To determine whether the in vitro performance of the formulations depends on the type of PRP preparation used to solubilize CS. METHODS:Formulations contai...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191058

    authors: Ghazi Zadeh L,Chevrier A,Lamontagne M,Buschmann MD,Hoemann CD,Lavertu M

    更新日期:2019-01-01 00:00:00

  • Flow visualization in the outflow cannula of an axial blood pump.

    abstract::The properties of blood flow in the outflow cannula of an axial blood pump play a critical role in potential thrombus formation and vascular injury. In this study, an in vitro flow visualization technique using particle image velocimetry (PIV) was applied to investigate the flow characteristics in the outflow cannula ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130791

    authors: Liu G,Zhang Y,Chen H,Sun H,Zhou J,Hu S

    更新日期:2014-01-01 00:00:00

  • Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

    abstract::In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zaki M,Aljinaidi A,Hamed M

    更新日期:2003-01-01 00:00:00

  • Predicting the minimal inhibitory concentration of fluoroquinolones for Escherichia coli using an accumulation model.

    abstract::The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the "Fick-Nernst-Planck" equatio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141203

    authors: Zhang W,Wang C,Tam KY

    更新日期:2014-01-01 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Mouse coronary angiography in vivo using synchrotron radiation.

    abstract:PURPOSE:To establish a method for mouse coronary angiography in vivo using synchrotron radiation, which is essential for physiological and pathological research on coronary diseases. METHODS:1) The imaging parameters (e.g., photon energy, spatial resolution of the detector, and injection rate of contrast agent) optima...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130937

    authors: Xu L,Zhang A,Du G,Xie H,Chen Y

    更新日期:2014-01-01 00:00:00

  • A study of load cycling in a NiTi shape memory alloy with pseudoelastic behaviour used in dental prosthetic fixators.

    abstract::NiTi alloy used in dental prosthetic fixators shows pseudoelastic behaviour and exhibits a great potential in dental and orthopaedic applications where constant correcting loads are required. In order to use such materials in dental prosthetic fixators, where the device is cyclically deformed, it is necessary to inves...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sabrià J,Cortada M,Giner L,Gil FJ,Fernández E,Manero JM,Planell JA

    更新日期:1996-01-01 00:00:00

  • Controlled release bevacizumab in thermoresponsive hydrogel found to inhibit angiogenesis.

    abstract::Age-related macular degeneration (ARMD) and intraocular neovascular diseases have been treated clinically by anti-VEGF antibody drug bevacizumab. However, the use of bevacizumab in the treatment of retinal neovascular diseases has been limited due to the short half-life and frequent injections. In this research, novel...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141003

    authors: Hu CC,Chaw JR,Chen CF,Liu HW

    更新日期:2014-01-01 00:00:00

  • Increased intrinsic stiffness and mineralization in femurs of adult rats after high intensity treadmill running training.

    abstract:BACKGROUND:Physical activity plays a tremendous role in determining bone mechanical behavior, which is superimposed to gravidity. OBJECTIVE:Compare the geometric and material responses of the rat femur to a high intensity treadmill running training of a relatively short duration, as assessed by 3-point mechanical test...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171684

    authors: Bozzini C,Viscor G,Kristjánsson JCR,Picasso E,Champin G,Alippi RM,Bozzini CE

    更新日期:2017-01-01 00:00:00

  • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.

    abstract::The debris generated by the progressive wear of total joint replacement (TJR) devices is considered a primary cause of osteolysis, bone resorption, and premature failure of artificial hips and knees. The vast majority of this debris originates from the UHMWPE articulating surfaces caused by tribological interaction wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Davidson JA,Poggie RA,Mishra AK

    更新日期:1994-01-01 00:00:00

  • Ultrasonic velocity and attenuation measurement in kidney stones: correlation to constituents and hardness.

    abstract::In this investigation, ultrasonic parameters of kidney stones are measured, in vitro, using a double probe ultrasonic-through-transmission technique. Due to the complex chemical structure of these stones, a large variation in the values of the ultrasonic parameters is found. A correlation between ultrasonic properties...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Singh VR,Dhawan JB

    更新日期:1992-07-01 00:00:00

  • Studies on poly(propylene fumarate-co-ethylene glycol) based bone cement.

    abstract::Poly(propylene fumarate-co-ethylene glycol) random (PPF-1) and block (PPF-2) copolymer oligomers were prepared. Comparing the setting characteristics of PPF-1 and PPF-2 with comonomer n-vinyl pyrrolidone (n-VP) and swelling characteristics of cured PPF-1 and PPF-2, lower setting temperature and setting time was observ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Jayabalan M,Thomas V,Sreelatha PK

    更新日期:2000-01-01 00:00:00

  • Aligned polyvinylpyrrolidone nanofibers with advanced electrospinning for biomedical applications.

    abstract:BACKGROUND:Electrospinning is a highly effective method in order to generate nano-scaled fibers. In conventional electrospinning technique, geometry of nanofibers are mostly random due to the chaotic behavior of polymer jet. OBJECTIVE:Purpose of this study is to produce aligned nanofibers from PVP polymers with advanc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181017

    authors: Karayeğen G,Koçum IC,Çökeli Ler Serdaroğlu D,Doğan M

    更新日期:2018-01-01 00:00:00

  • Amount of metallic ions released from Ti-Ni alloy by abrasion in simulated bioliquids.

    abstract::The current density of Ti-56mass%Ni (Ti-50at.%) alloy after abrasion in simulated bioliquids was measured using a potentiostat to estimate the amount of metallic ions released from the alloy during repassivation and maturation. The current density in saline, saline with and without N2 bubbling, and Hanks' solutions wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Watarai M,Hanawa T,Moriyama K,Asaoka K

    更新日期:1999-01-01 00:00:00

  • Evaluation of chondrocytes expression embedded in thermoresponsive poly(amino acid)s with sol-gel transition.

    abstract::Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chueh SK,Tachibana Y,Uyama H,Kobayashi S,Tomita N

    更新日期:2007-01-01 00:00:00

  • The in vitro and in vivo indomethacin release from self-setting bioactive glass bone cement.

    abstract::The in vivo and in vitro drug release profiles from a self-setting bioactive CaO-SiO2-P2O5 glass bone cement containing indomethacin as a model drug were investigated. The cement containing 2% and 5% indomethacin (IMC) powder hardened within 5 min after mixing with ammonium phosphate buffer. After setting, in vitro dr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Otsuka M,Nakahigashi Y,Matsuda Y,Kokubo T,Yoshihara S,Fujita H,Nakamura T

    更新日期:1997-01-01 00:00:00

  • Improved bond performance of a dental adhesive system using nano-technology.

    abstract::Since adhesive technology was introduced into dental field, metal-based restoration has been gradually replaced by metal-free restoration. Using the adhesive technology, minimum invasive technique has been possible in daily clinical practice as well as esthetic tooth-colored restorations have become very popular all o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-2009-0587

    authors: Nagano F,Selimovic D,Noda M,Ikeda T,Tanaka T,Miyamoto Y,Koshiro K,Sano H

    更新日期:2009-01-01 00:00:00

  • An experimental study on the biomechanical properties of the cancellous bones of distal femur.

    abstract:OBJECTIVE:To study the comprehensive biomechanical properties of the cancellous bone of distal femur through a series of mechanical tests, and provide relevant subjects with the basic technical data. BACKGROUND:The study on bone mechanics is a commonly used approach to evaluate the biomechanical competency of bone. Th...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Du C,Ma H,Ruo M,Zhang Z,Yu X,Zeng Y

    更新日期:2006-01-01 00:00:00

  • An improved finite element modeling of the cerebrospinal fluid layer in the head impact analysis.

    abstract::The finite element (FE) method has been widely used to investigate the mechanism of traumatic brain injuries (TBIs), because it is technically difficult to quantify the responses of the brain tissues to the impact in experiments. One of technical challenges to build a FE model of a human head is the modeling of the ce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171666

    authors: Wu JZ,Pan CS,Wimer BM,Rosen CL

    更新日期:2017-01-01 00:00:00

  • Electrochemical behaviour of a cobalt-chromium-molybdenum dental alloy in artificial salivas: Influence of phosphate ions and mucin components.

    abstract::The stability of the Co-Cr-Mo dental alloy immersed in artificial salivas (pH 6.7) was investigated over 24 h. Three artificial salivas have been studied: saline saliva (saliva I); saline saliva buffered with phosphate ions (saliva II) and saliva II plus mucin molecules (saliva III). For all the systems, open circuit ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141241

    authors: de Aguiar SR,Nicolai M,Almeida M,Gomes A

    更新日期:2015-01-01 00:00:00

  • Deterioration in the superelasticity of Ti sputter coated on NiTi orthodontic wire.

    abstract::To evaluate the deterioration in the superelasticity of Ti-coated NiTi orthodontic wires, titanium was coated onto wires to form a 1-microm thick film using radio frequency magnetron sputtering. In superelasticity cycle tests, the sigma5.0 value (the stress at 5.0% strain) of a Ti-coated wire was lower than that of a ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ozeki K,Yuhta T,Aoki H,Asaoka T,Daisaku T,Fukui Y

    更新日期:2003-01-01 00:00:00

  • Injectable CMC/PEI gel as an in vivo scaffold for demineralized bone matrix.

    abstract::A number of materials have been considered as sources of grafts to repair bone defects. Here, we examined the possibility of creating in situ-forming gels from sodium carboxymethylcellulose (CMC) and poly(ethyleneimine) (PEI) for use as an in vivo carrier of demineralized bone matrix (DBM). The interaction between ani...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0603

    authors: Kim KS,Kang YM,Lee JY,Kim ES,Kim CH,Min BH,Lee HB,Kim JH,Kim MS

    更新日期:2009-01-01 00:00:00

  • Patient specific respiratory motion modeling using a limited number of 3D lung CT images.

    abstract::To build a patient specific respiratory motion model with a low dose, a novel method was proposed that uses a limited number of 3D lung CT volumes with an external respiratory signal. 4D lung CT volumes were acquired for patients with in vitro labeling on the upper abdominal surface. Meanwhile, 3D coordinates of in vi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141133

    authors: Cui X,Gao X,Xia W,Liu Y,Liang Z

    更新日期:2014-01-01 00:00:00

  • Introduction to tissue engineering and application for cartilage engineering.

    abstract::Tissue engineering is a multidisciplinary field that applies the principles of engineering, life sciences, cell and molecular biology toward the development of biological substitutes that restore, maintain, and improve tissue function. In Western Countries, tissues or cells management for clinical uses is a medical ac...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0624

    authors: de Isla N,Huseltein C,Jessel N,Pinzano A,Decot V,Magdalou J,Bensoussan D,Stoltz JF

    更新日期:2010-01-01 00:00:00

  • Mechanical properties of cancellous tissue in compression test and nanoindentation.

    abstract::The goal of the study was to determine material constants of cancellous tissue in a compression test taking into account stress-strain characteristics. The nineteen test samples were resected from a femoral head of a patient qualified for a hip replacement surgery. During the compression tests, load-displacement curve...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-180999

    authors: Kokot G,Makuch A,Skalski K,Bańczerowski J

    更新日期:2018-01-01 00:00:00

  • Milkvetch root improves immune function in patients with acute exacerbation of COPD.

    abstract::Milkvetch root as a medicine has been used for more over 2000 years in China, can strengthen immune function, protect liver, promote urination, resist aging and stress, reduce blood pressure and extensively resist bacterium. This study explored the effects of milkvetch root on the immune function of patients with a de...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.3233/BME-151517

    authors: Jiang D,Wang X,Su Q,Jiang S,Yuan F,Zhang C,Gong F,Dong Q,Shi J,Chen B

    更新日期:2015-01-01 00:00:00

  • Cellular compatibility of highly degradable bioactive ceramics for coating of metal implants.

    abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0678

    authors: Radetzki F,Wohlrab D,Zeh A,Delank KS,Mendel T,Berger G,Syrowatka F,Mayr O,Bernstein A

    更新日期:2011-01-01 00:00:00