An improved finite element modeling of the cerebrospinal fluid layer in the head impact analysis.

Abstract:

:The finite element (FE) method has been widely used to investigate the mechanism of traumatic brain injuries (TBIs), because it is technically difficult to quantify the responses of the brain tissues to the impact in experiments. One of technical challenges to build a FE model of a human head is the modeling of the cerebrospinal fluid (CSF) of the brain. In the current study, we propose to use membrane elements to construct the CSF layer. Using the proposed approach, we demonstrate that a head model can be built by using existing meshes available in commercial databases, without using any advanced meshing software tool, and with the sole use of native functions of the FE package Abaqus. The calculated time histories of the intracranial pressures at frontal, posterior fossa, parietal, and occipital positions agree well with the experimental data and the simulations in the literature, indicating that the physical effects of the CSF layer have been accounted for in the proposed modeling approach. The proposed modeling approach would be useful for bioengineers to solve practical problems.

journal_name

Biomed Mater Eng

authors

Wu JZ,Pan CS,Wimer BM,Rosen CL

doi

10.3233/BME-171666

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

187-199

issue

2

eissn

0959-2989

issn

1878-3619

pii

BME1666

journal_volume

28

pub_type

杂志文章
  • Evaluation of the pro-angiogenic effect of nanoscale extracellular vesicles derived from human umbilical cord mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are a common tool in regenerative medicine. The nanoscale extracellular vesicles (nEVs) secreted by these cells were recently brought up to light thanks to their therapeutic potential. In this study, we assessed the in vitro behaviour of human umbilical vein endothelial cells (HUVECs) exp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171626

    authors: Dostert G,Willemin AS,Jouan-Hureaux V,Louis H,Hupont S,Gillet P,Menu P,Decot V,Moby V,Velot É

    更新日期:2017-01-01 00:00:00

  • A comparison study on the flexural strength and compressive strength of four resin-modified luting glass ionomer cements.

    abstract::The purpose of this study is to compare the differences in flexural strength and compressive strength between four resin-modified luting glass ionomer cements that are commonly used in clinics. Furthermore, this study investigates the influence of curing mode on the flexural strength and compressive strength of dual-c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151284

    authors: Li Y,Lin H,Zheng G,Zhang X,Xu Y

    更新日期:2015-01-01 00:00:00

  • Effect of platelet-rich plasma on bone engineering with an alloplastic substitute containing BMP2.

    abstract::A robust method for inducing bone-formation without an autograft has not been established. Currently, both platelet-rich plasma (PRP) and bone morphogenetic protein (BMP) have been widely investigated for their clinical use in such cases. However, their synergistic effect is still controversial and previously shown di...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130741

    authors: Yoshida K,Sumita Y,Marukawa E,Harashima M,Asahina I

    更新日期:2013-01-01 00:00:00

  • Application of polyethylene air-bubble cushions to improve the shock absorption performance of Type I construction helmets for repeated impacts.

    abstract:BACKGROUND:The use of helmets was considered to be one of the important prevention strategies employed on construction sites. The shock absorption performance of a construction (or industrial) helmet is its most important performance parameter. Industrial helmets will experience cumulative structural damage when being ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201132

    authors: Wu JZ,Pan CS,Ronaghi M,Wimer BM,Reischl U

    更新日期:2021-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • SIFT algorithm-based 3D pose estimation of femur.

    abstract::To address the lack of 3D space information in the digital radiography of a patient femur, a pose estimation method based on 2D-3D rigid registration is proposed in this study. The method uses two digital radiography images to realize the preoperative 3D visualization of a fractured femur. Compared with the pure Digit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141103

    authors: Zhang X,Zhu Y,Li C,Zhao J,Li G

    更新日期:2014-01-01 00:00:00

  • Reinforcement of acrylic resins for provisional fixed restorations. Part III: effects of addition of titania and zirconia mixtures on some mechanical and physical properties.

    abstract::Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems assoc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Panyayong W,Oshida Y,Andres CJ,Barco TM,Brown DT,Hovijitra S

    更新日期:2002-01-01 00:00:00

  • The effects of restricting the flexion-extension motion of the first metatarsophalangeal joint on human walking gait.

    abstract::The first metatarsophalangeal (MTP) joint is a critical component for normal walking. The present study aimed to investigate the effects of restricting the flexion-extension motion of the first MTP joint on human walking gait. Ten male participants were recruited to perform walking trials under barefoot (BF) and the f...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141073

    authors: Zhang J,Si Y,Zhang Y,Liu Y

    更新日期:2014-01-01 00:00:00

  • Evaluation of NiTi Superelastic Retraction Coil Springs for orthodontic tooth movement in rats.

    abstract::The purpose of this investigation was to assess mechanical properties of Superelastic Retraction Coil Springs for orthodontic use. To reach a goal, a test frame, comprising measuring force transducers was developed. To perform metallographic analyses of the nickel-titanium wire the samples of Superelastic Retraction C...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0647

    authors: Rozman J,Mrvar P,Drevenšek M,Pečlin P

    更新日期:2010-01-01 00:00:00

  • Calcium phosphate fibers coated with collagen: In vivo evaluation of the effects on bone repair.

    abstract::The aim of this study was to assess the characteristics of the CaP/Col composites, in powder and fiber form, via scanning electron microscopy (SEM), pH and calcium release evaluation after immersion in SBF and to evaluate the performance of these materials on the bone repair process in a tibial bone defect model. For ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161581

    authors: Ueno FR,Kido HW,Granito RN,Gabbai-Armelin PR,Magri AM,Fernandes KR,da Silva AC,Braga FJ,Renno AC

    更新日期:2016-08-12 00:00:00

  • The development of artificial articular cartilage--PVA-hydrogel.

    abstract::Aqueous poly(vinyl alcohol) solutions were frozen at -20 degrees C for 6-12 h, and subsequently thawed for 1-2 h. The above mentioned process repeated for 1-3 times. After the specimen was dehydrated in vacuum, a kind of artificial articular cartilage--PVA-hydrogel--was developed. The micromorphology of PVA-hydrogel h...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Gu ZQ,Xiao JM,Zhang XH

    更新日期:1998-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00

  • Mouse coronary angiography in vivo using synchrotron radiation.

    abstract:PURPOSE:To establish a method for mouse coronary angiography in vivo using synchrotron radiation, which is essential for physiological and pathological research on coronary diseases. METHODS:1) The imaging parameters (e.g., photon energy, spatial resolution of the detector, and injection rate of contrast agent) optima...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130937

    authors: Xu L,Zhang A,Du G,Xie H,Chen Y

    更新日期:2014-01-01 00:00:00

  • Oxymatrine inhibited cell proliferation by inducing apoptosis in human lung cancer A549 cells.

    abstract::To investigate the inhibition effect of oxymatrine induces human lung cancer A549 cells apoptosis. The A549 cells were cultured for 24 h, than the various concentration of oxymatrine (2 mmol/L, 4 mmol/L, 8 mmol/L, 15 mmol/L) were added into different experimental group cells, and 5-fluorouracil were added into the pos...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151302

    authors: Wang B,Han Q,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Self-expanding stents in the treatment of carotid artery subtotal occlusion: a clinical study on the patients of Hubei and Sichuan in China.

    abstract::Stroke is a major cause of death and disability throughout the world. Subtotal occlusion of the carotid artery is an important risk factor for stroke. Carotid artery stenting (CAS) is increasingly being used for treatment of carotid artery stenosis. There are many reports on treating carotid artery stenosis by CAS; ho...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0687

    authors: Zhang C,Wang Z,Zheng H,Qiu Y,He X,Yang H,Liu W

    更新日期:2012-01-01 00:00:00

  • Effect of hydroxyapatite sol on cell proliferation and alkaline phosphatase activity of osteoblastic MC3T3-E1 cells.

    abstract::The effect of hydroxyapatite sol (HAm) which is composed of unheating hydroxyapatite microcrystal particle on cell proliferation and alkaline phophatase activity in osteoblastic MC3T3-E1 cells, was examined in the presence or absence of fetal calfe serum (FCS) in the medium. In the absence of FCS, HAm inhibited the ce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Iwakami T,Imai T

    更新日期:2002-01-01 00:00:00

  • Prediction model of sinoatrial node field potential using high order partial least squares.

    abstract::High order partial least squares (HOPLS) is a novel data processing method. It is highly suitable for building prediction model which has tensor input and output. The objective of this study is to build a prediction model of the relationship between sinoatrial node field potential and high glucose using HOPLS. The thr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151482

    authors: Feng Y,Cao H,Zhang Y

    更新日期:2015-01-01 00:00:00

  • Interaction of collagen triple-helix with carbon nanotubes: Geometric property of rod-like molecules.

    abstract::The interactions between carbon nanotubes and important biomolecules, above all collagen molecules, have not been studied in detail. This situation is partly due to the fact that CNT are solid entities, while most of the biomolecules can be prepared in solution. We used turbidity as a means of evaluating the interacti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0557

    authors: Kuboki Y,Terada M,Kitagawa Y,Abe S,Uo M,Watari F

    更新日期:2009-01-01 00:00:00

  • A novel diagnostic system for Doppler ultrasound of the peripheral arteries to detect the presence of thoracic aortic aneurysm.

    abstract:OBJECTIVE:We aimed to develop a novel ultrasound system and examine its feasibility for noninvasively detecting thoracic aortic aneurysm (TAA) in clinical settings. METHODS:We developed a novel ultrasound system consisting of a modified console and data analysis algorithm. The exploratory study included 100 patients h...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191047

    authors: Hayatsu Y,Watanabe K,Sasaki K,Masaki N,Katahira S,Kumagai K,Kawamoto S,Ohmi T,Yokobori AT Jr,Saiki Y

    更新日期:2019-01-01 00:00:00

  • Electrochemical behaviour of a cobalt-chromium-molybdenum dental alloy in artificial salivas: Influence of phosphate ions and mucin components.

    abstract::The stability of the Co-Cr-Mo dental alloy immersed in artificial salivas (pH 6.7) was investigated over 24 h. Three artificial salivas have been studied: saline saliva (saliva I); saline saliva buffered with phosphate ions (saliva II) and saliva II plus mucin molecules (saliva III). For all the systems, open circuit ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141241

    authors: de Aguiar SR,Nicolai M,Almeida M,Gomes A

    更新日期:2015-01-01 00:00:00

  • A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent.

    abstract:BACKGROUND:Stenting has been proposed as an effective treatment to restore blood flow in obstructed arteries by plaques. Although several modified designs for stents have been suggested, most designs have the risk of disturbing blood flow. OBJECTIVE:The main objective is to propose a stent design to attain a uniform l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171691

    authors: Beigzadeh B,Mirmohammadi SA,Ayatollahi MR

    更新日期:2017-01-01 00:00:00

  • Adipose tissue regeneration in a 3D-printed poly(lactic acid) frame-supported space in the inguinal region of rats.

    abstract:BACKGROUND:Adipose tissue engineering has been studied as an alternative to current options for breast reconstruction, such as lipofilling, flap reconstruction, and silicone implants. Previously, we demonstrated that a poly(L-lactic acid) mesh containing a collagen sponge, containing neither cells nor growth factors, c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201103

    authors: Kambe Y,Ogino S,Yamanaka H,Morimoto N,Yamaoka T

    更新日期:2020-01-01 00:00:00

  • Cellulose nanowhiskers: preparation, characterization and cytotoxicity evaluation.

    abstract:OBJECTIVE:To characterize the structure and to evaluate the cytotoxicity of cellulose nanowhiskers (CNW) prepared from cotton linters. METHODS:A series of CNW dispersions was prepared by hydrolyzing cotton linters with sulfuric acid. The structure of CNW was characterized by scanning electron microscopy (SEM), transmi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0697

    authors: Ni H,Zeng S,Wu J,Cheng X,Luo T,Wang W,Zeng W,Chen Y

    更新日期:2012-01-01 00:00:00

  • Extracellular matrices as advanced scaffolds for vascular tissue engineering.

    abstract::An alternative non-vascular extracellular material was obtained by decellularisation of porcine urinary bladder and examined for its potential as scaffold for vascular tissue engineering. Analysis using Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Laser Scanning Microscopy (LSCM) showed a poro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0598

    authors: Piterina AV,Callanan A,Davis L,Meaney C,Walsh M,McGloughlin TM

    更新日期:2009-01-01 00:00:00

  • Cellular compatibility of highly degradable bioactive ceramics for coating of metal implants.

    abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0678

    authors: Radetzki F,Wohlrab D,Zeh A,Delank KS,Mendel T,Berger G,Syrowatka F,Mayr O,Bernstein A

    更新日期:2011-01-01 00:00:00

  • Multi-boundary cardiac data visualization based on multidimensional transfer function with ray distance.

    abstract::A crucial role during the implementation of volume visualization is to identify the optimal transfer function, since the vital information and structure can be highlighted and revealed. The boundary of the volume is shared by respective portion of the two materials formed out of it, which causes undesirable thickening...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141123

    authors: Yang F,Zhang L,Lu W,Zuo W,Wang K,Zhang H,Li Y

    更新日期:2014-01-01 00:00:00

  • The fracture toughness characteristics of three dental composite resins.

    abstract::A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture to...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

    更新日期:1991-01-01 00:00:00

  • Evaluation of chondrocytes expression embedded in thermoresponsive poly(amino acid)s with sol-gel transition.

    abstract::Poly(N-substituted alpha/beta-asparagine) was evaluated as a thermoresponsible and an injectable scaffold for cartilage regeneration. Solutions of this polymer are liquid state below 25 degrees C and nonfluid hydrogel above 35 degrees C, allowing an aqueous solution containing cells at room temperature to form a hydro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Chueh SK,Tachibana Y,Uyama H,Kobayashi S,Tomita N

    更新日期:2007-01-01 00:00:00

  • Rapid counting method of living cells by fluorescent enzyme substrates.

    abstract::The 5(and 6)-carboxyfluorescein diacetate (C-FDA) is used for a rapid and continuous counting of living cells. Nonfluorescent C-FDA is converted into fluorescent 5(and 6)-carboxyfluorescein (C-F) by the reaction with esterase, which is an enzyme of living cells. The conversion makes it possible to count the number of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sugata K,Ohnishi T,Matsumoto K

    更新日期:1991-01-01 00:00:00

  • Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    abstract::A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Jones VC,Barton DC,Auger DD,Hardaker C,Stone MH,Fisher J

    更新日期:2001-01-01 00:00:00