Calcium phosphate fibers coated with collagen: In vivo evaluation of the effects on bone repair.

Abstract:

:The aim of this study was to assess the characteristics of the CaP/Col composites, in powder and fiber form, via scanning electron microscopy (SEM), pH and calcium release evaluation after immersion in SBF and to evaluate the performance of these materials on the bone repair process in a tibial bone defect model. For this, four different formulations (CaP powder - CaPp, CaP powder with collagen - CaPp/Col, CaP fibers - CaPf and CaP fibers with collagen - CaPf/Col) were developed. SEM images indicated that both material forms were successfully coated with collagen and that CaPp and CaPf presented HCA precursor crystals on their surface. Although presenting different forms, FTIR analysis indicated that CaPp and CaPf maintained the characteristic peaks for this class of material. Additionally, the calcium assay study demonstrated a higher Ca uptake for CaPp compared to CaPf for up to 5 days. Furthermore, pH measurements revealed that the collagen coating prevented the acidification of the medium, leading to higher pH values for CaPp/Col and CaPf/Col. The histological analysis showed that CaPf/Col demonstrated a higher amount of newly formed bone in the region of the defect and a reduced presence of material. In summary, the results indicated that the fibrous CaP enriched with the organic part (collagen) glassy scaffold presented good degradability and bone-forming properties and also supported Runx2 and RANKL expression. These results show that the present CaP/Col fibrous composite may be used as a bone graft for inducing bone repair.

journal_name

Biomed Mater Eng

authors

Ueno FR,Kido HW,Granito RN,Gabbai-Armelin PR,Magri AM,Fernandes KR,da Silva AC,Braga FJ,Renno AC

doi

10.3233/BME-161581

subject

Has Abstract

pub_date

2016-08-12 00:00:00

pages

259-73

issue

2-3

eissn

0959-2989

issn

1878-3619

pii

BME1581

journal_volume

27

pub_type

杂志文章
  • Feasibility study of custom hip stem design based on X-ray films.

    abstract::The hip stem design based upon X-ray films requires sufficient information in order to customize for the patient. If the errors are resulted from rotating angles, more X-ray films may carry out the solution. The present study aimed to realize the improvement of multiple X-ray films for hip stem design. Eight X-ray fil...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wei HW,Chung MY,Huang VW,Cheng CK

    更新日期:2004-01-01 00:00:00

  • Experimental exploration of mouse kidney imaging with the SR PCI technology.

    abstract::This paper explores mouse kidney imaging with diffraction enhanced imaging (DEI) and inline outline X-ray imaging (IOXI) technology, and evaluates latent value of kidney imaging with phase contrast imaging technology. In our experiment, spatial resolution and tissue contrast serve as element evaluation and comparison....

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130917

    authors: Xia C,Peng YF,Arun KY,Xiao T,Zhu P,He W

    更新日期:2014-01-01 00:00:00

  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • Amount of metallic ions released from Ti-Ni alloy by abrasion in simulated bioliquids.

    abstract::The current density of Ti-56mass%Ni (Ti-50at.%) alloy after abrasion in simulated bioliquids was measured using a potentiostat to estimate the amount of metallic ions released from the alloy during repassivation and maturation. The current density in saline, saline with and without N2 bubbling, and Hanks' solutions wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Watarai M,Hanawa T,Moriyama K,Asaoka K

    更新日期:1999-01-01 00:00:00

  • A novel registration method for image-guided neurosurgery system based on stereo vision.

    abstract::This study presents a novel spatial registration method of Image-guided neurosurgery system (IGNS) based on stereo-vision. Images of the patient's head are captured by a video camera, which is calibrated and tracked by an optical tracking system. Then, a set of sparse facial data points are reconstructed from them by ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151391

    authors: An Y,Wang M,Song Z

    更新日期:2015-01-01 00:00:00

  • Evaluation of the pro-angiogenic effect of nanoscale extracellular vesicles derived from human umbilical cord mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are a common tool in regenerative medicine. The nanoscale extracellular vesicles (nEVs) secreted by these cells were recently brought up to light thanks to their therapeutic potential. In this study, we assessed the in vitro behaviour of human umbilical vein endothelial cells (HUVECs) exp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171626

    authors: Dostert G,Willemin AS,Jouan-Hureaux V,Louis H,Hupont S,Gillet P,Menu P,Decot V,Moby V,Velot É

    更新日期:2017-01-01 00:00:00

  • Optically-guided scalpel with light-scattering module for carpal tunnel surgical procedure via minimally invasive surgery.

    abstract::A novel technique and product for carpal tunnel microscopic surgical procedures using a modified medical device containing a head as a surgical scalpel under light guidance were designed and studied. The novel design of the medical device was developed and applied in a new carpal tunnel microscopic surgical procedure ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151303

    authors: Chiang MC,Huang CC

    更新日期:2015-01-01 00:00:00

  • Degradability in vitro of polyurethanes based on synthetic atactic poly[(R,S)-3-hydroxybutyrate].

    abstract::The aim of the present study was to determine the degradability of aliphatic polyurethanes, based on a different amount of synthetic, atactic poly[(R,S)-3-hydroxybutyrate] (a-PHB), in hydrolytic (phosphate buffer) and oxidative (H2O2/CoCl2) solutions. The soft segments were built with atactic poly[(R,S)-3-hydroxybutyr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151262

    authors: Brzeska J,Janeczek H,Janik H,Kowalczuk M,Rutkowska M

    更新日期:2015-01-01 00:00:00

  • Rapid counting method of living cells by fluorescent enzyme substrates.

    abstract::The 5(and 6)-carboxyfluorescein diacetate (C-FDA) is used for a rapid and continuous counting of living cells. Nonfluorescent C-FDA is converted into fluorescent 5(and 6)-carboxyfluorescein (C-F) by the reaction with esterase, which is an enzyme of living cells. The conversion makes it possible to count the number of ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sugata K,Ohnishi T,Matsumoto K

    更新日期:1991-01-01 00:00:00

  • Development of asymmetric stent for treatment of eccentric plaque.

    abstract::The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat ecce...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181737

    authors: Syaifudin A,Takeda R,Sasaki K

    更新日期:2018-01-01 00:00:00

  • A molecule-imprinted polyaniline membrane modified on carbon fiber for detection of glycine.

    abstract::A layer of L-glycine-molecule-imprinted polyaniline (LMIP-PANI) polymer film has been modified on a carbon fiber electrode for the determination of L-glycine standard samples and L-glycine in cerebrospinal fluid of wistar mice. It has been found that a linear relationship exists between current and concentration for t...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130907

    authors: Zeng H,Wang D,Yu J

    更新日期:2014-01-01 00:00:00

  • A study of load cycling in a NiTi shape memory alloy with pseudoelastic behaviour used in dental prosthetic fixators.

    abstract::NiTi alloy used in dental prosthetic fixators shows pseudoelastic behaviour and exhibits a great potential in dental and orthopaedic applications where constant correcting loads are required. In order to use such materials in dental prosthetic fixators, where the device is cyclically deformed, it is necessary to inves...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sabrià J,Cortada M,Giner L,Gil FJ,Fernández E,Manero JM,Planell JA

    更新日期:1996-01-01 00:00:00

  • Selection of human p75NTR tag SNPs and its biological significance for clinical association studies.

    abstract::To select tag single nucleotide polymorphisms (SNPs) within and around human p75 neurotrophin receptor (p75NTR) gene in Chinese Han population, the sequence involving p75NTR gene as well as the upstream and downstream of the gene was identified according to the data from National Center for Biotechnology Information (...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141213

    authors: Wang YT,Lu XM,Shu YH,Xiao L,Chen KT

    更新日期:2014-01-01 00:00:00

  • Chimerism analysis following nonmyeloablative stem cell transplantation using a new cell subset separation method: Robosep.

    abstract::Chimerism analysis has become an important tool to manage patients in the peri-transplant period of allogenic stem cell transplantation. During this period, cells of donor and host origin can coexist and increasing proportion of cells of host origin is considered as a recurrence of the underlying disease. We currently...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Decot V,Latger-Cannard V,Lecompte T,Clément L,Salmon A,Bordigoni P,Stoltz JF,Bensoussan D

    更新日期:2008-01-01 00:00:00

  • Cellular compatibility of highly degradable bioactive ceramics for coating of metal implants.

    abstract::Resorbable ceramics can promote the bony integration of implants. Their rate of degradation should ideally be synchronized with bone regeneration. This study examined the effect of rapidly resorbable calcium phosphate ceramics 602020, GB14, 305020 on adherence, proliferation and morphology of human bone-derived cells ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2012-0678

    authors: Radetzki F,Wohlrab D,Zeh A,Delank KS,Mendel T,Berger G,Syrowatka F,Mayr O,Bernstein A

    更新日期:2011-01-01 00:00:00

  • Tinting effect of ultraviolet radiation on intraocular lenses of polymethyl methacrylate.

    abstract::Intraocular lenses (IOL) made of polymethyl methacrylate (PMMA) lack an important yellowish pigment useful as a filter in the visual process and in the protection of the retina from short wavelength light. It was found that the PMMA used for IOL manufacturing can be tinted by dry exposure to mercury near-UV emitting l...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Babizhayev MA,Chumayevskii NA

    更新日期:1994-01-01 00:00:00

  • Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.

    abstract::The present review surveys studies on physical-chemical properties and biological response of living tissues to NiTi (Nitinol) carried out recently, aiming at an understanding of the place of this material among the implant alloys in use. Advantages of shape memory and superelasticity are analyzed in respect to functi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:

    authors: Shabalovskaya SA

    更新日期:2002-01-01 00:00:00

  • Simultaneous quantitative analysis of indomethacin and benzoic acid in gel using ultra-violet-visible spectrophotometry and chemometrics.

    abstract:BACKGROUND:In order to manufacture pharmaceutical products, real-time monitoring in the manufacturing process is necessary, but large equipment cost is required to achieve it. OBJECTIVE:The aim of this research is to use ultra-violet-visible spectroscopy along with chemometrics procedure to simultaneously carry out qu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-181034

    authors: Peerapattana J,Hattori Y,Otsuka M

    更新日期:2019-01-01 00:00:00

  • Effect of surface roughness on the initial response of MC3T3-E1 cells cultured on polished titanium alloy.

    abstract::Surface roughness has been considered as an important influencing factor for cell response. The aim of this study was to find out whether MC3T3-E1 cells, a mouse osteoblast-like cell line, can sense the amplitudes of surface topography of titanium alloy (Ti6Al4V), and if surface-dependent cell morphology would be pres...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151301

    authors: Wu C,Chen M,Zheng T,Yang X

    更新日期:2015-01-01 00:00:00

  • Thyroid hormone disorders and sepsis.

    abstract::Sepsis is a systemic inflammatory response syndrome with high mortality, which results from severe infection and can lead to secondary organ dysfunction. It is one of the most common cause of death in intensive care unit. Clinical reports have shown that sepsis was often accompanied by thyroid dysfunction, which is ca...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-171646

    authors: Luo B,Yu Z,Li Y

    更新日期:2017-01-01 00:00:00

  • The effects of restricting the flexion-extension motion of the first metatarsophalangeal joint on human walking gait.

    abstract::The first metatarsophalangeal (MTP) joint is a critical component for normal walking. The present study aimed to investigate the effects of restricting the flexion-extension motion of the first MTP joint on human walking gait. Ten male participants were recruited to perform walking trials under barefoot (BF) and the f...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141073

    authors: Zhang J,Si Y,Zhang Y,Liu Y

    更新日期:2014-01-01 00:00:00

  • Parameter optimization for the visco-hyperelastic constitutive model of tendon using FEM.

    abstract::Numerous constitutive models describing the mechanical properties of tendons have been proposed during the past few decades. However, few were widely used owing to the lack of implementation in the general finite element (FE) software, and very few systematic studies have been done on selecting the most appropriate pa...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0653

    authors: Tang CY,Ng GY,Wang ZW,Tsui CP,Zhang G

    更新日期:2011-01-01 00:00:00

  • Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.

    abstract::In recent years, there is an increasing utilization and demand to use magnetic fields in bioengineering applications due to its beneficial effects. Although in the last decade more attention has been given by tribologists to the electromagnetic processes taking place between sliding surfaces, which influence the tribo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zaki M,Aljinaidi A,Hamed M

    更新日期:2003-01-01 00:00:00

  • Assessment of the nanostructure of acid-base resistant zone by the application of all-in-one adhesive systems: Super dentin formation.

    abstract::An acid-base resistant zone (ABRZ) has been shown to be created under a hybrid layer in a self-etching adhesive system at the adhesive/dentin interface. The purpose of this study was to assess the nanostructure of the ABRZ by applying all-in-one adhesive systems. Human premolar dentin was treated with one of two all-i...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0576

    authors: Nikaido T,Weerasinghe DD,Waidyasekera K,Inoue G,Foxton RM,Tagami J

    更新日期:2009-01-01 00:00:00

  • Cellulose sponge as a scaffold for cartilage tissue engineering.

    abstract::One goal of functional tissue engineering is to manufacture scaffolds infiltrated with chondrocytes which are suitable for transplantation into the lesion areas of articular cartilage. Various research strategies are used to fabricate cartilage transplants which would have the correct phenotype, contain enough extrace...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Pulkkinen H,Tiitu V,Lammentausta E,Laasanen MS,Hämäläinen ER,Kiviranta I,Lammi MJ

    更新日期:2006-01-01 00:00:00

  • Controlled release bevacizumab in thermoresponsive hydrogel found to inhibit angiogenesis.

    abstract::Age-related macular degeneration (ARMD) and intraocular neovascular diseases have been treated clinically by anti-VEGF antibody drug bevacizumab. However, the use of bevacizumab in the treatment of retinal neovascular diseases has been limited due to the short half-life and frequent injections. In this research, novel...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141003

    authors: Hu CC,Chaw JR,Chen CF,Liu HW

    更新日期:2014-01-01 00:00:00

  • Increased intrinsic stiffness and mineralization in femurs of adult rats after high intensity treadmill running training.

    abstract:BACKGROUND:Physical activity plays a tremendous role in determining bone mechanical behavior, which is superimposed to gravidity. OBJECTIVE:Compare the geometric and material responses of the rat femur to a high intensity treadmill running training of a relatively short duration, as assessed by 3-point mechanical test...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171684

    authors: Bozzini C,Viscor G,Kristjánsson JCR,Picasso E,Champin G,Alippi RM,Bozzini CE

    更新日期:2017-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • Effect of platelet-rich plasma on bone engineering with an alloplastic substitute containing BMP2.

    abstract::A robust method for inducing bone-formation without an autograft has not been established. Currently, both platelet-rich plasma (PRP) and bone morphogenetic protein (BMP) have been widely investigated for their clinical use in such cases. However, their synergistic effect is still controversial and previously shown di...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130741

    authors: Yoshida K,Sumita Y,Marukawa E,Harashima M,Asahina I

    更新日期:2013-01-01 00:00:00

  • Predicting the minimal inhibitory concentration of fluoroquinolones for Escherichia coli using an accumulation model.

    abstract::The objective of this study is to evaluate whether the accumulation model developed by Zarfl et al. (2008) could be used to predict the minimal inhibitory concentration (MIC) of a group of antibacterial fluoroquinolones (FQs) for Escherichia coli (E. coli). Our model, which is based on the "Fick-Nernst-Planck" equatio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141203

    authors: Zhang W,Wang C,Tam KY

    更新日期:2014-01-01 00:00:00