Application of polyethylene air-bubble cushions to improve the shock absorption performance of Type I construction helmets for repeated impacts.

Abstract:

BACKGROUND:The use of helmets was considered to be one of the important prevention strategies employed on construction sites. The shock absorption performance of a construction (or industrial) helmet is its most important performance parameter. Industrial helmets will experience cumulative structural damage when being impacted repeatedly with impact magnitudes greater than its endurance limit. OBJECTIVE:The current study is to test if the shock absorption performance of Type I construction helmets subjected to repeated impacts can be improved by applying polyethylene air-bubble cushions to the helmet suspension system. METHODS:Drop impact tests were performed using a commercial drop tower test machine following the ANSI Z89.1 Type I drop impact protocol. Typical off-the-shelf Type I construction helmets were evaluated in the study. A 5 mm thick air-bubble cushioning liner was placed between the headform and the helmet to be tested. Helmets were impacted ten times at different drop heights from 0.61 to 1.73 m. The effects of the air-bubble cushioning liner on the helmets' shock absorption performance were evaluated by comparing the peak transmitted forces collected from the original off-the-shelf helmet samples to the helmets equipped with air-bubble cushioning liners. RESULTS:Our results showed that a typical Type I construction helmet can be subjected to repeated impacts with a magnitude less than 22 J (corresponding to a drop height 0.61 m) without compromising its shock absorption performance. In comparison, the same construction helmet, when equipped with an air-bubble cushioning liner, can be subjected to repeated impacts of a magnitude of 54 J (corresponding to a drop height 1.52 m) without compromising its shock absorption performance. CONCLUSIONS:The results indicate that the helmet's shock absorbing endurance limit has been increased by 145% with addition of an air-bubble cushioning liner.

journal_name

Biomed Mater Eng

authors

Wu JZ,Pan CS,Ronaghi M,Wimer BM,Reischl U

doi

10.3233/BME-201132

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

1-14

issue

1

eissn

0959-2989

issn

1878-3619

pii

BME201132

journal_volume

32

pub_type

杂志文章
  • Accelerating sino-atrium computer simulations with graphic processing units.

    abstract::Sino-atrial node cells (SANCs) play a significant role in rhythmic firing. To investigate their role in arrhythmia and interactions with the atrium, computer simulations based on cellular dynamic mathematical models are generally used. However, the large-scale computation usually makes research difficult, given the li...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151365

    authors: Zhang H,Xiao Z,Lin SF

    更新日期:2015-01-01 00:00:00

  • A statistical approach to segmentation of diffusion tensor imaging.

    abstract::The aim of this study is to design a statistical segmentation technique to allow extraction of grey matter, white matter and cerebral spinal fluid volumes from diffusion tensor imaging. Four channel maps of the DTI are used as the input features, which provide more information for brain tissue segmentation compared wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130927

    authors: Wen Y,He L

    更新日期:2014-01-01 00:00:00

  • Injectable CMC/PEI gel as an in vivo scaffold for demineralized bone matrix.

    abstract::A number of materials have been considered as sources of grafts to repair bone defects. Here, we examined the possibility of creating in situ-forming gels from sodium carboxymethylcellulose (CMC) and poly(ethyleneimine) (PEI) for use as an in vivo carrier of demineralized bone matrix (DBM). The interaction between ani...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0603

    authors: Kim KS,Kang YM,Lee JY,Kim ES,Kim CH,Min BH,Lee HB,Kim JH,Kim MS

    更新日期:2009-01-01 00:00:00

  • The effect of counter-ions on the ion selectivity of potassium and sodium ions in nanopores.

    abstract::The ion selective transport plays an important role in the function of cell membranes, and promotes the application of artificial permeable membranes. This phenomenon has been studied in case for different diameters and functional groups of nanopores. In this work, we focus on the effect of anions on cation selectivit...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130822

    authors: Tang D,Kim D

    更新日期:2014-01-01 00:00:00

  • Amount of metallic ions released from Ti-Ni alloy by abrasion in simulated bioliquids.

    abstract::The current density of Ti-56mass%Ni (Ti-50at.%) alloy after abrasion in simulated bioliquids was measured using a potentiostat to estimate the amount of metallic ions released from the alloy during repassivation and maturation. The current density in saline, saline with and without N2 bubbling, and Hanks' solutions wi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Watarai M,Hanawa T,Moriyama K,Asaoka K

    更新日期:1999-01-01 00:00:00

  • Individual tooth region segmentation using modified watershed algorithm with morphological characteristic.

    abstract::In this paper, a new method for individual tooth segmentation was proposed. The proposed method is composed of enhancement and extraction of boundary and seed of watershed algorithm using trisection areas by morphological characteristic of teeth. The watershed algorithm is one of the conventional methods for tooth seg...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141153

    authors: Na SD,Lee G,Lee JH,Kim MN

    更新日期:2014-01-01 00:00:00

  • Short-term human chondrocyte culturing on oriented collagen coated gelatine scaffolds for cartilage replacement.

    abstract::The biological, biochemical, mechanical, and structural properties of artificial scaffolds for tissue engineering are known to be of great importance. Therefore, in this study a hydrogel derived scaffold with biomechanical and structural properties similar to native articular cartilage was synthesized. The gelatine-ba...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Zehbe R,Libera J,Gross U,Schubert H

    更新日期:2005-01-01 00:00:00

  • Effect of stenosis on hemodynamics in left coronary artery based on patient-specific CT scan.

    abstract:BACKGROUND:The most common cause of coronary artery disease (CAD) is vascular damage with the cholesterol built-up and other materials on the inner arterial wall, known as atherosclerosis. OBJECTIVE:This paper aims to investigate the effect of stenosis on the hemodynamics in the four suspected coronary artery disease ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191067

    authors: Kamangar S,Salman Ahmed NJ,Badruddin IA,Al-Rawahi N,Husain A,Govindaraju K,Yunus Khan TM

    更新日期:2019-01-01 00:00:00

  • Bioshell calcium oxide (BiSCaO) for cleansing and healing Pseudomonas aeruginosa-infected wounds in hairless rats.

    abstract:BACKGROUND:Scallop shell powder is called bioshell calcium oxide (BiSCaO), which is known to possess deodorizing properties and broad antimicrobial activity against various pathogenic microbes, including viruses, bacteria, spores, and fungi. OBJECTIVE:This study aims to investigate the applications of BiSCaO suspensio...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-201082

    authors: Takayama T,Ishihara M,Sato Y,Nakamura S,Fukuda K,Murakami K,Yokoe H

    更新日期:2020-01-01 00:00:00

  • Surface degradation study of magnesium tested in simulated body fluid.

    abstract::Magnesium has attracted a lot of attention as a new class of biodegradable material. The surface properties of magnesium in simulated body fluid (SBF) were investigated in the current research work. Cast magnesium samples with different surface characteristics were prepared which were then placed in SBF for 2, 4 and 8...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-191057

    authors: Sana A,Malik I,Mujahid M,Akram MA,Adeel Umer M

    更新日期:2019-01-01 00:00:00

  • Age-related alterations in TGF beta signaling as a causal factor of cartilage degeneration in osteoarthritis.

    abstract:BACKGROUND:Age is the most important risk factor for primary osteoarthritis (OA). Members of the TGF-β superfamily play a crucial role in chondrocyte differentiation and maintenance of healthy articular cartilage. OBJECTIVE:We have investigated whether age-related changes in TGF-β superfamily signaling components play...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140976

    authors: van der Kraan PM

    更新日期:2014-01-01 00:00:00

  • Degradability in vitro of polyurethanes based on synthetic atactic poly[(R,S)-3-hydroxybutyrate].

    abstract::The aim of the present study was to determine the degradability of aliphatic polyurethanes, based on a different amount of synthetic, atactic poly[(R,S)-3-hydroxybutyrate] (a-PHB), in hydrolytic (phosphate buffer) and oxidative (H2O2/CoCl2) solutions. The soft segments were built with atactic poly[(R,S)-3-hydroxybutyr...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151262

    authors: Brzeska J,Janeczek H,Janik H,Kowalczuk M,Rutkowska M

    更新日期:2015-01-01 00:00:00

  • Bone regeneration from human mesenchymal stem cells on porous hydroxyapatite-PLGA-collagen bioactive polymer scaffolds.

    abstract::We have developed a novel multicomponent nano-hydroxyapatite-poly(D,L-lactide-co-glycolide)-collagen biomaterial (nHAP-PLGA-collagen) with mechanical properties similar to human cancellous bone. To demonstrate the bone forming capacity of nHAP-PLGA-collagen prior to in vivo experiments, nHAP-PLGA-collagen films and 3D...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171703

    authors: Bhuiyan DB,Middleton JC,Tannenbaum R,Wick TM

    更新日期:2017-01-01 00:00:00

  • A bioelectrical impedance phase angle measuring system for assessment of nutritional status.

    abstract::Bioelectrical impedance phase angle has been recommended as a tool to assess nutrition state, but there are no measuring devices have been specially designed for hospital residents. In this study, a system was established for the measurement of bioelectrical impedance phase angle. The electrical composition, calculati...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141193

    authors: Zhang G,Huo X,Wu C,Zhang C,Duan Z

    更新日期:2014-01-01 00:00:00

  • Increased intrinsic stiffness and mineralization in femurs of adult rats after high intensity treadmill running training.

    abstract:BACKGROUND:Physical activity plays a tremendous role in determining bone mechanical behavior, which is superimposed to gravidity. OBJECTIVE:Compare the geometric and material responses of the rat femur to a high intensity treadmill running training of a relatively short duration, as assessed by 3-point mechanical test...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171684

    authors: Bozzini C,Viscor G,Kristjánsson JCR,Picasso E,Champin G,Alippi RM,Bozzini CE

    更新日期:2017-01-01 00:00:00

  • A novel approach for arrhythmia diagnosis: Self-adaptive and distribution-free mode.

    abstract::Arrhythmia diagnosis is very significant to ensure human health. In this paper, a new model is developed for arrhythmia diagnosis. A salient feature of the algorithm is a synergistic combination of statistical and fuzzy set-based techniques. It is distribution-free and is realized in an unsupervised mode. Arrhythmia d...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151400

    authors: Li F,Zheng D,Zhao T

    更新日期:2015-01-01 00:00:00

  • IB-LBM simulation on blood cell sorting with a micro-fence structure.

    abstract::A size-based blood cell sorting model with a micro-fence structure is proposed in the frame of immersed boundary and lattice Boltzmann method (IB-LBM). The fluid dynamics is obtained by solving the discrete lattice Boltzmann equation, and the cells motion and deformation are handled by the immersed boundary method. A ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130833

    authors: Wei Q,Xu YQ,Tian FB,Gao TX,Tang XY,Zu WH

    更新日期:2014-01-01 00:00:00

  • Effect of contacts configuration and location on selective stimulation of cuff electrode.

    abstract:BACKGROUND:Cuff electrodes have been widely used chronically in different clinical applications. Advancements have been made in selective stimulation by using multi-contact cuff electrodes. Steering anodic current is a strategy to increase selectivity by reshaping and localizing electric fields. There are two configura...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151281

    authors: Taghipour-Farshi H,Frounchi J,Ahmadiasl N,Shahabi P,Salekzamani Y

    更新日期:2015-01-01 00:00:00

  • Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses.

    abstract::Mechanical testing has been performed to characterize the locking strength of Morse taper locks used for reconstruction of large bone defects. Taper joint pairs were locked with a series of compressive loads increasing from 500 to 3500 N. Following each load application the taper locks were distracted with either an a...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Duda GN,Elias JJ,Valdevit A,Chao EY

    更新日期:1997-01-01 00:00:00

  • Counter-propagation network with variable degree variable step size LMS for single switch typing recognition.

    abstract::Morse code is now being harnessed for use in rehabilitation applications of augmentative-alternative communication and assistive technology, including mobility, environmental control and adapted worksite access. In this paper, Morse code is selected as a communication adaptive device for disabled persons who suffer fr...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:

    authors: Yang CH,Luo CH,Yang CH,Chuang LY

    更新日期:2004-01-01 00:00:00

  • Patterned layers of adsorbed extracellular matrix proteins: influence on mammalian cell adhesion.

    abstract::Three patterned systems aiming at the control of mammalian cell behavior are presented. The determinant feature common to these systems is the spatial distribution of extracellular matrix (ECM) proteins (mainly collagen) on polymer substrates. This distribution differs from one system to another with respect to the sc...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dupont-Gillain CC,Alaerts JA,Dewez JL,Rouxhet PG

    更新日期:2004-01-01 00:00:00

  • Mechanical behavior of quartz fiber reinforced epoxy resins for teeth restoration.

    abstract::In this work composite materials, based on quartz fibers and epoxy resins, were employed with the aim to restore damaged teeth. The composite materials were chosen because they show biomechanical features very similar to that of the dentine, the main constituent of the tooth. Extracted teeth were rebuilt with two diff...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Visco AM,Calabrese L,Campo N,Torrisi L,Oteri G,Lo Giudice G,Cicciù D

    更新日期:2006-01-01 00:00:00

  • Ultrathin polymer monolayers for promotion of cell growth on bioprosthetic materials -- evolution of a new concept to improve long term performance of biologic heart vales.

    abstract::Reoperation of aldehyde tanned bioprotheses due to calcific degeneration remains their major drawback. Based on experiments studying mechanisms and factors that influence the time phase, extent and progression of calcification and evaluating the efficiency of anticalcification treatments and the effects of surface see...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Dahm M,Rühe J,Berchthold B,Prüfer D,Prucker O,Chang BJ,Wallrath A,Oelert H

    更新日期:2004-01-01 00:00:00

  • Regulation of periodontal ligament-derived cells by type III collagen-coated hydroxyapatite.

    abstract:BACKGROUND:The periodontal ligament (PDL), which maintains homeostasis in the periodontium, is a group of specialized connective tissue fibers attached to both the cementum and alveolar bone. Regeneration of periodontium with PDL cells has been investigated, and the chemical and molecular structures of scaffolds contro...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171709

    authors: Fujita K,Nozaki K,Horiuchi N,Yamashita K,Miura H,Nagai A

    更新日期:2018-01-01 00:00:00

  • Interaction of collagen triple-helix with carbon nanotubes: Geometric property of rod-like molecules.

    abstract::The interactions between carbon nanotubes and important biomolecules, above all collagen molecules, have not been studied in detail. This situation is partly due to the fact that CNT are solid entities, while most of the biomolecules can be prepared in solution. We used turbidity as a means of evaluating the interacti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2009-0557

    authors: Kuboki Y,Terada M,Kitagawa Y,Abe S,Uo M,Watari F

    更新日期:2009-01-01 00:00:00

  • Influence of modified alginate hydrogels on mesenchymal stem cells and olfactory bulb-derived glial cells cultures.

    abstract:BACKGROUND:Great potential of cellular therapies has generated extensive research in the field of cells harvesting and culturing. Transplantation of cell cultures has been used in a variety of therapeutic programs but in many cases it appeared that biomaterial scaffold or sheath would enhance cells regenerative potenti...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-140966

    authors: Marycz K,Szarek D,Grzesiak J,Wrzeszcz K

    更新日期:2014-01-01 00:00:00

  • Residual stress in bone structure and tissue of rabbit's tibiofibula.

    abstract::This paper presents an X-ray diffraction method of measuring the residual stress/strain in bone tissue of rabbit's tibia. To derive the residual stress, bone powder of the diameter less than 40 micrometers was used as a control specimen at non-stressed state. From the X-ray measurements, it was clear that the distribu...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Tadano S,Okoshi T

    更新日期:2006-01-01 00:00:00

  • Evaluation of the pro-angiogenic effect of nanoscale extracellular vesicles derived from human umbilical cord mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are a common tool in regenerative medicine. The nanoscale extracellular vesicles (nEVs) secreted by these cells were recently brought up to light thanks to their therapeutic potential. In this study, we assessed the in vitro behaviour of human umbilical vein endothelial cells (HUVECs) exp...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171626

    authors: Dostert G,Willemin AS,Jouan-Hureaux V,Louis H,Hupont S,Gillet P,Menu P,Decot V,Moby V,Velot É

    更新日期:2017-01-01 00:00:00

  • 4D model of hemodynamics in the abdominal aorta.

    abstract::The paper presents an application of the FSI technique to determine hemodynamics in the abdominal aorta (AA). To establish boundary conditions for the FSI study, MR anatomical data and 4D MRI velocity-mapping data (in three blood flow velocity directions and time) were collected to acquire realistic geometry of the AA...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151312

    authors: Zbicinski I,Veshkina N,Stefańczyk L

    更新日期:2015-01-01 00:00:00

  • Control of FES in paraplegia: modeling voluntary arm forces.

    abstract::Skilled behavior is difficult or impossible to articulate explicitly by the performers. Likewise biomechanical models of skilled motor actions are often limited by the lack of knowledge of the underlying mechanisms. A 'behavioral cloning' technique is described, based on a trained artificial neural network (ANN), that...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Andrews BJ,Davoodi R,Kamnik R,Bajd T

    更新日期:1998-01-01 00:00:00