The fracture toughness characteristics of three dental composite resins.

Abstract:

:A fracture mechanics approach has been adopted in the present study to investigate the fracture toughness behavior of three commercial composite resins for dental use named Clearfil photo posterior, P-50 and Occlusin. The resins have been cast in to ring-shaped specimens for the determination of individual fracture toughness values. The experimentally determined values have been compared with fracture toughness values obtained from the indentation micro-fracture method, which is the currently more popular test method for determining fracture toughness characteristics of composite resins. Occlusin was found to exhibit higher fracture toughness values than any other resin, employing the ring specimen test procedure. However, this was not the case when using the indentation method which gave comparable fracture toughness values for all three resins. It was concluded that the ring specimen provides a simple, accurate and reproducible method for providing a measure of the materials fracture toughness.

journal_name

Biomed Mater Eng

authors

Higo Y,Damri D,Nunomura S,Kumada K,Sawa N,Hanaoka K,Teranaka T,Iwamoto T

subject

Has Abstract

pub_date

1991-01-01 00:00:00

pages

223-31

issue

4

eissn

0959-2989

issn

1878-3619

journal_volume

1

pub_type

杂志文章
  • Nonholonomic mobile system control by combining EEG-based BCI with ANFIS.

    abstract::Motor imagery EEG-based BCI has advantages in the assistance of human control of peripheral devices, such as the mobile robot or wheelchair, because the subject is not exposed to any stimulation and suffers no risk of fatigue. However, the intensive training necessary to recognize the numerous classes of data makes it...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-151409

    authors: Yu W,Feng H,Feng Y,Madani K,Sabourin C

    更新日期:2015-01-01 00:00:00

  • New clinical failure mode triggered by a new coronary stent design.

    abstract::Longitudinal stent compression (LSC) is a new failure mode not previously observed in coronary stents. This phenomenon occurs when the physician tries to cross the deployed stent with other devices. While this phenomenon has been observed with a number of stent designs, it seems more common with the Element stent. A c...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130781

    authors: Hsiao HM,Yeh CT,Chiu YH,Wang C,Chen CP

    更新日期:2014-01-01 00:00:00

  • Introduction to tissue engineering and application for cartilage engineering.

    abstract::Tissue engineering is a multidisciplinary field that applies the principles of engineering, life sciences, cell and molecular biology toward the development of biological substitutes that restore, maintain, and improve tissue function. In Western Countries, tissues or cells management for clinical uses is a medical ac...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0624

    authors: de Isla N,Huseltein C,Jessel N,Pinzano A,Decot V,Magdalou J,Bensoussan D,Stoltz JF

    更新日期:2010-01-01 00:00:00

  • Thermal-mechanical deformation modelling of soft tissues for thermal ablation.

    abstract::Modeling of thermal-induced mechanical behaviors of soft tissues is of great importance for thermal ablation. This paper presents a method by integrating the heating process with thermal-induced mechanical deformations of soft tissues for simulation and analysis of the thermal ablation process. This method combines bi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141043

    authors: Li X,Zhong Y,Jazar R,Subic A

    更新日期:2014-01-01 00:00:00

  • A study of load cycling in a NiTi shape memory alloy with pseudoelastic behaviour used in dental prosthetic fixators.

    abstract::NiTi alloy used in dental prosthetic fixators shows pseudoelastic behaviour and exhibits a great potential in dental and orthopaedic applications where constant correcting loads are required. In order to use such materials in dental prosthetic fixators, where the device is cyclically deformed, it is necessary to inves...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Sabrià J,Cortada M,Giner L,Gil FJ,Fernández E,Manero JM,Planell JA

    更新日期:1996-01-01 00:00:00

  • pH-responsive mesoporous silica nanocarriers based on layer-by-layer self-assembly.

    abstract::Significant progress has been achieved in the field of pH-sensitive drug delivery system in recent years. For layer-by-layer self-assembly nanocarriers, various pH values can induce the change of permeability and structural stability of the outer polyelectrolyte multi-layers, resulting in the release of the loaded dru...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141033

    authors: Zhang HY,Sun YF,Sun YL,Zhou M

    更新日期:2014-01-01 00:00:00

  • Wave propagation in the silicon tube: comparison of the two-point and three-point pressure methods.

    abstract::The values of the propagation coefficient measured on a silicon rubber tube in the frequency range 1-15 Hz were compared, using four different equations. The first formula is based on three simultaneous pressure measurements performed at equidistant points; the remaining three equations are original, and make use of o...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Ursino M,Artioli E

    更新日期:1992-10-01 00:00:00

  • Analysis of basal physical fitness and lumbar muscle function according to indoor horse riding exercise.

    abstract::The aim of this study is to verify the effect of indoor horse riding exercise on basal physical exercise and lumbar muscular function. The subjects included were 20 healthy females, who participated in the horse riding exercise using SRider (Rider Co. & ChonbuK National Univ, Korea) for 30 minutes per day, 3 days per ...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-141053

    authors: Yu CH,Hong CU,Kang SR,Kwon TK

    更新日期:2014-01-01 00:00:00

  • Synthesis and enhanced bone regeneration of carbonate substituted octacalcium phosphate.

    abstract::Using a wet method, we have synthesized octacalcium phosphate carbonate, in which HPO42- in octacalcium phosphate is replaced with CO32-. The physical, crystal, and chemical properties of this new material were compared to octacalcium phosphate, Ca-deficient hydroxyapatite, and Ca-deficient carbonate apatite using X-r...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171651

    authors: Shen D,Horiuchi N,Nozaki S,Miyashin M,Yamashita K,Nagai A

    更新日期:2017-01-01 00:00:00

  • A study on reference standard for cytotoxicity assay of biomaterials.

    abstract::The objective of the present study was to find a standard substance for use as a reference in the cytotoxicity assay of biomaterials, as an alternative to animal experiments in recent years. Eight kinds of rubber were made in a plate shape to keep their surface area at 1 cm2 against 10 ml of extract volume. They were ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Oshima H,Nakamura M

    更新日期:1994-01-01 00:00:00

  • Mechanical properties of cancellous tissue in compression test and nanoindentation.

    abstract::The goal of the study was to determine material constants of cancellous tissue in a compression test taking into account stress-strain characteristics. The nineteen test samples were resected from a femoral head of a patient qualified for a hip replacement surgery. During the compression tests, load-displacement curve...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-180999

    authors: Kokot G,Makuch A,Skalski K,Bańczerowski J

    更新日期:2018-01-01 00:00:00

  • Failed attempts and improvement strategies in peripheral intravenous catheterization.

    abstract:BACKGROUND:Access to peripheral veins is necessary for sample collection, transfusion and infusion of fluids or medications. The peripheral intravenous catheterization (PIVC) procedure is the introduction of a short catheter into a peripheral vein and can be problematic, leading to multiple failed attempts. PURPOSE:To...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-120735

    authors: Sabri A,Szalas J,Holmes KS,Labib L,Mussivand T

    更新日期:2013-01-01 00:00:00

  • Mechanical strength of sutured block copolymers films for load bearing medical applications.

    abstract::The mechanical behavior of three styrenic thermoplastic block copolymer elastomers with applied surgical sutures was studied by uniaxial tensile testing. The materials exhibited oriented cylindrical microstructure. Distinct macroscopic deformation mechanisms have been observed upon stretching of samples with vertical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130843

    authors: Stasiak J,Nair S,Moggridge GD

    更新日期:2014-01-01 00:00:00

  • A new method to accurately assess post-laser-surgery refractive changes with the intrinsic corneal power changes.

    abstract::To evaluate the ability of assessing the refractive change induced by myopic laser surgery using the intrinsic data, obtained from a reference intrinsic to the cornea. Twenty-nine eyes with laser in situ keratomileusis for myopia were included in the study. Statistical analyses were performed to determine the relation...

    journal_title:Bio-medical materials and engineering

    pub_type: 临床试验,杂志文章

    doi:10.3233/BME-151374

    authors: Liu Y,Wang Z,Wang Y

    更新日期:2015-01-01 00:00:00

  • Parametric analysis of the stress distribution on the articular cartilage and subchondral bone.

    abstract::Few studies have stressed on the sensitivity of stress distribution in different mechanical properties of the articular cartilage and subchondral bone. The purpose of this study was to establish parametric variations of mechanical factors individually and examine how these biomechanical effects influenced the cartilag...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Wang Y,Wei HW,Yu TC,Cheng CK

    更新日期:2007-01-01 00:00:00

  • An ensemble feature selection technique for cancer recognition.

    abstract::Correlation-based feature selection (CFS) using neighborhood mutual information (NMI) and particle swarm optimization (PSO) are combined into an ensemble technique in this paper. Based on this observation, an efficient gene selection algorithm, denoted by NMICFS-PSO, is proposed. Several cancer recognition tasks are g...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130897

    authors: Xu J,Sun L,Gao Y,Xu T

    更新日期:2014-01-01 00:00:00

  • Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    abstract::A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Jones VC,Barton DC,Auger DD,Hardaker C,Stone MH,Fisher J

    更新日期:2001-01-01 00:00:00

  • Influence of tooth brushing on adhesion strength of orthodontic brackets bonded to porcelain.

    abstract:BACKGROUND:Adhesive resin composite, which is used to bond orthodontic bracket to tooth surface is exposed to the influence of wear by tooth brushing and wear may influence loosening of the bracket. OBJECTIVE:The aim of this study was to evaluate in vitro the effect of tooth brushing on the adhesion strength of orthod...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-161592

    authors: Durgesh BH,Alhijji S,Hashem MI,Al Kheraif AA,Durgesh P,Elsharawy M,Vallittu PK

    更新日期:2016-09-28 00:00:00

  • Biocompatibility of 17-4 PH stainless steel foam for implant applications.

    abstract::In this study, biocompatibility of 17-4 PH stainless steel foam for biomedical implant applications was investigated. 17-4 PH stainless steel foams having porosities in the range of 40-82% with an average pore size of around 600 μm were produced by space holder-sintering technique. Sintered foams were precipitation ha...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2011-0671

    authors: Mutlu I,Oktay E

    更新日期:2011-01-01 00:00:00

  • Renal epithelia in long term gradient culture for biomaterial testing and tissue engineering.

    abstract::In the organism epithelia perform perfect barrier functions. Strong rheological and mechanical influences constitute the normal environment of this tissue throughout life. Most epithelia are exposed to different fluids at the luminal and basal sides. To obtain realistic information about tissue development in modern b...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Minuth WW,Schumacher K,Strehl R

    更新日期:2005-01-01 00:00:00

  • Osteogenic differentiation of cultured marrow stromal stem cells on surface of microporous hydroxyapatite based mica composite and macroporous synthetic hydroxyapatite.

    abstract::In order to investigate the significance of hydroxyapatite based microporous composite (HA/mica composite) surfaces and a macroporous synthetic hydroxyapatite, rat marrow cell culture, which shows osteogenic differentiation, was carried out on six different culture substrata (two control culture dishes, two identical ...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Nordström E,Ohgushi H,Yoshikawa T,Yokobori AT Jr,Yokobori T

    更新日期:1999-01-01 00:00:00

  • Nondestructive analysis of dielectric properties: application to ion beam irradiated tissue response microfibre.

    abstract::The aim of this work was to investigate the effect of 2.4 MeV proton irradiation on the dielectric property of polyethylene terephthalate (PET) microfibre nondestructively. The dielectric constant εd of single-microfibre has been measured as-such applying laser diffraction technique. Applying this methodology εd is fo...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130947

    authors: Mallick B

    更新日期:2014-01-01 00:00:00

  • Effect of platelet-rich plasma on bone engineering with an alloplastic substitute containing BMP2.

    abstract::A robust method for inducing bone-formation without an autograft has not been established. Currently, both platelet-rich plasma (PRP) and bone morphogenetic protein (BMP) have been widely investigated for their clinical use in such cases. However, their synergistic effect is still controversial and previously shown di...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130741

    authors: Yoshida K,Sumita Y,Marukawa E,Harashima M,Asahina I

    更新日期:2013-01-01 00:00:00

  • Hyaluronic acid as an internal phase additive to obtain ofloxacin/PLGA microsphere by double emulsion method.

    abstract::Hyaluronic acid (HA) was used as an internal phase additive to improve the loading efficiency of ofloxacin, a hydrophilic drug encapsulated by hydrophobic polylactic-co-glycolic acid (PLGA) materials, through a double emulsion (water-in-oil-in-water) solvent extraction/evaporation method. Results from laser distributi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-130863

    authors: Wu G,Chen L,Li H,Wang YJ

    更新日期:2014-01-01 00:00:00

  • MicroRNAs: potential biomarkers for disease diagnosis.

    abstract::MicroRNAs (miRNAs) are a group of endogenous noncoding small RNAs characterized by high conservation; furthermore, various studies have shown the capability of miRNAs to impact diseases. For example, a study shows that cell-free miRNAs are stable in bodily fluids, which gives circulating miRNAs the ability to be poten...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章,评审

    doi:10.3233/BME-141223

    authors: Xu L,Qi X,Duan S,Xie Y,Ren X,Chen G,Yang X,Han L,Dong Q

    更新日期:2014-01-01 00:00:00

  • Evaluation of NiTi Superelastic Retraction Coil Springs for orthodontic tooth movement in rats.

    abstract::The purpose of this investigation was to assess mechanical properties of Superelastic Retraction Coil Springs for orthodontic use. To reach a goal, a test frame, comprising measuring force transducers was developed. To perform metallographic analyses of the nickel-titanium wire the samples of Superelastic Retraction C...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-2010-0647

    authors: Rozman J,Mrvar P,Drevenšek M,Pečlin P

    更新日期:2010-01-01 00:00:00

  • The dynein-triggered ciliary motion in embryonic nodes: an exploratory study based on computational models.

    abstract::The cilia, presenting a rotational movement in the embryonic nodes, play a crucial role in the left-right specification during embryogenesis. The characteristic architecture of these cilia is based on a cylindrical arrangement of 9 doublet microtubules and the motion of the cilia is triggered by the dynein motors loca...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141063

    authors: Chen D,Zhong Y,Shinohara K,Nishida T,Hasegawa T,Hamada H

    更新日期:2014-01-01 00:00:00

  • Bone regeneration from human mesenchymal stem cells on porous hydroxyapatite-PLGA-collagen bioactive polymer scaffolds.

    abstract::We have developed a novel multicomponent nano-hydroxyapatite-poly(D,L-lactide-co-glycolide)-collagen biomaterial (nHAP-PLGA-collagen) with mechanical properties similar to human cancellous bone. To demonstrate the bone forming capacity of nHAP-PLGA-collagen prior to in vivo experiments, nHAP-PLGA-collagen films and 3D...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-171703

    authors: Bhuiyan DB,Middleton JC,Tannenbaum R,Wick TM

    更新日期:2017-01-01 00:00:00

  • Patient specific respiratory motion modeling using a limited number of 3D lung CT images.

    abstract::To build a patient specific respiratory motion model with a low dose, a novel method was proposed that uses a limited number of 3D lung CT volumes with an external respiratory signal. 4D lung CT volumes were acquired for patients with in vitro labeling on the upper abdominal surface. Meanwhile, 3D coordinates of in vi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:10.3233/BME-141133

    authors: Cui X,Gao X,Xia W,Liu Y,Liang Z

    更新日期:2014-01-01 00:00:00

  • Theoretical foundation on a noninvasive estimation for viscoelastic mechanical property of blood vessels by ultrasonic Doppler effect.

    abstract::The method used in this paper is developed to estimate the degree of viscoelasticity of the blood vessel wall in a noninvasive mechanical method. In this proposed method, we can obtain an output waveform connected with mechanical behavior of blood vessels by using Ultrasonic Doppler Effect Sensory (UDES). Characterizi...

    journal_title:Bio-medical materials and engineering

    pub_type: 杂志文章

    doi:

    authors: Yoshinari H,Yokobori AT Jr,Ohkuma T

    更新日期:1994-01-01 00:00:00