Initial experience with Impella RP in a quaternary transplant center.

Abstract:

:Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of flow. We analyzed all the patients with right ventricular failure that were treated with Impella RP in our institution. The Impella RP was implanted percutaneously in the catheterization laboratory guided by fluoroscopy. Overall, 7 patients required the implantation of an Impella RP due to right ventricular failure: 2 after long-term LVAD, 3 presented with acute right ventricular failure immediately after LVAD implantation, and 2 needed it after heart transplantation. Regarding complications, we report 2 patients with hemolysis. Hemodynamic parameters as well as end-organ perfusion and inotropic requirements improved after the insertion of the Impella. Overall, 30-day survival is 58%. Median time of support was 9 (5-19) days. RV failure is one of the most challenging complications after LVAD implantation and heart transplantation. The major challenge is the timing of implantation. The minimally invasive nature of the Impella RP facilitates de-escalation of treatment and paves the road to recovery. Impella RP proved useful in facilitating ECMO wean. Used in a prompt manner alongside the ease of implantation and the minimal rate of complications, Impella RP seems to be an appropriate device to tackle RV failure providing enough flow to allow for recovery or escalation decision-making.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Monteagudo-Vela M,Simon A,Panoulas V

doi

10.1111/aor.13610

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

473-477

issue

5

eissn

0160-564X

issn

1525-1594

journal_volume

44

pub_type

杂志文章
  • Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13128

    authors: Hoxha S,Abbasciano RG,Sandrini C,Rossetti L,Menon T,Barozzi L,Linardi D,Rungatscher A,Faggian G,Luciani GB

    更新日期:2018-04-01 00:00:00

  • Development of high-efficiency molecular adsorbent recirculating system: preliminary report.

    abstract::Molecular Adsorbent Recirculating System (MARS) is a liver support system widely employed in the treatment of liver failure. The method is normally well tolerated. To develop a liver support system combining high efficiency and tolerability, we modified the MARS albumin circuit with the insertion of double adsorption ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12250

    authors: Marangoni R,Bellati G,Castelli A,Romagnoli E

    更新日期:2014-10-01 00:00:00

  • Results of the European clinical trial of Arrow CorAide left ventricular assist system.

    abstract::The aim of this study was to evaluate the safety and performance of the Arrow CorAide left ventricular assist system (LVAS) (Arrow International, Reading, PA, USA), a continuous-flow left ventricular assist device, as bridge to transplantation or recovery as well as destination therapy in patients with New York Heart ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.2012.01539.x

    authors: Saeed D,Arusoglu L,Gazzoli F,Hetzer R,Morshius M,Alloni A,Viganò M,Koerfer R,Golding LA,El Banayosy A

    更新日期:2013-02-01 00:00:00

  • Pre- and postoperative magnetic resonance imaging in neonatal arterial switch operation using warm perfusion.

    abstract::Neurological morbidity is a major concern in pediatric cardiac surgery. Cardiopulmonary bypass is one of the few modifiable factors affecting neurodevelopmental outcome. This study aimed to measure the incidence of abnormalities apparent by magnetic resonance imaging (MRI) after neonatal arterial switch operation usin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01325.x

    authors: Durandy Y,Rubatti M,Couturier R,Rohnean A

    更新日期:2011-11-01 00:00:00

  • Use of hemoperfusion in experimental intoxication with nerve agents.

    abstract::The aim of this study was to evaluate the efficiency of hemoperfusion (HP) through coated resin adsorbent Synachrom E-5 in animal intoxications with organophosphate inhibitors of cholinesterases type of nerve agents. Five anesthetized dogs were intoxicated with 2 to 6 LD50 of VX substance and another 4 with 2 to 3 LD5...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03317.x

    authors: Monhart V,Fusek J,Brndiar M,Tlustakova M

    更新日期:1994-10-01 00:00:00

  • A hybrid mock circulation loop for a total artificial heart.

    abstract::Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the development of physiological control algorithms is accelerated with new evaluation environments. In this article, we present a novel hybrid mock circulation loop (HMCL) designed specifically for evaluation of rotary total artif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12380

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL,Frazier OH,Cohn WE

    更新日期:2014-09-01 00:00:00

  • Can the human lumbar posterior columns be stimulated by transcutaneous spinal cord stimulation? A modeling study.

    abstract::Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation, and movement. The human lumbar cord has become a target for modification of motor control by epidural and, more recently, by transcutaneous spinal cord stimulation. Posterior col...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01213.x

    authors: Danner SM,Hofstoetter US,Ladenbauer J,Rattay F,Minassian K

    更新日期:2011-03-01 00:00:00

  • What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

    abstract::Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately cont...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12702

    authors: Naito N,Nishimura T,Takewa Y,Kishimoto S,Date K,Umeki A,Ando M,Ono M,Tatsumi E

    更新日期:2016-11-01 00:00:00

  • The impact of obesity on outcomes in patients receiving extracorporeal life support.

    abstract::Extracorporeal life support (ECLS) has been increasingly utilized to manage cardiac and pulmonary dysfunction. The impact of obesity on outcomes of ECLS is poorly defined. The purpose of the study was to compare in-hospital mortality, resource use, complications, and readmissions in obese versus non-obese patients rec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13752

    authors: Christian-Miller N,Hadaya J,Nakhla M,Sanaiha Y,Madrigal J,Emami S,Cale M,Sareh S,Benharash P

    更新日期:2020-11-01 00:00:00

  • Pulsatile flow and simple flow control method during weaning period in centrifugal pump: toward more expanded usage in open heart surgery.

    abstract::To expand the usage of the centrifugal pump (CP) in open heart surgery, we performed two studies. In the first, we evaluated pulsatile flow in the CP. In vitro pump performance of the Terumo Capiox pump (TCP) and the Sarns Delphin pump (SDP) and increase of free hemoglobin (mg/dl) after driving 6 h were investigated u...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03393.x

    authors: Nishida H,Koyanagi H,Endo M,Suzuki S,Oshiyama H,Nojiri C,Fukasawa H,Akutsu T

    更新日期:1994-09-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.

    abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02279.x

    authors: Allen R,Frost TH,Hoenich NA

    更新日期:1995-11-01 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • Pseudoendothelium formation in expanded polytetrafluoroethylene grafts implanted in the inferior vena cava of normal and defibrinogenated dogs.

    abstract::The outgrowth of endothelial cells in an expanded polytetrafluoroethylene graft implanted in the canine inferior vena cava was studied by scanning electron microscopy. The adjacent endothelial cells of the vena cava started to invade the anastomotic area three days after the implantation and reached approximately the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04020.x

    authors: Ishimaru S,Berglin E,Hansson HA,Teger-Nilsson AC,William-Olsson G

    更新日期:1981-11-01 00:00:00

  • Hemoperfusion and DNA synthesis in the rat liver. Part I: the effect of hemoperfusion on the rate of DNA synthesis.

    abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04080.x

    authors: Ryan CJ,Courtney JM,Wood CB,Blumgart LH

    更新日期:1982-05-01 00:00:00

  • Pathways for water absorption and physiological role of the lateral interspaces in the kidney tubule.

    abstract::Possible routes for water and salt flow and the most likely theories that describe coupling between water and salt flow across leaky epithelia are presented. The osmotic theories seem the most likely ones. However, several of the theories have weaknesses that render them unsatisfactory, in particular because of the po...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1987.tb02713.x

    authors: Whittembury G,Carpi-Medina P,González E,Linares H

    更新日期:1987-12-01 00:00:00

  • Effects of pK variability on bicarbonate balance evaluation in dialysis patients.

    abstract::Bicarbonate balance is usually calculated from the Henderson-Hasselbalch equation under the assumption that pK is constant. To evaluate the pK variability and its effects on bicarbonate computed with autoanalyzers in dialysis patients, we studied 44 patients on maintenance hemodialysis. The pH, PCO2, total CO2, and pK...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02715.x

    authors: Santoro A,Ferrari G,Spongano M,Cavalli F,Zucchelli P

    更新日期:1987-12-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Extracorporeal life support during and after bilateral sequential lung transplantation in patients with pulmonary artery hypertension.

    abstract::The use of extracorporeal membrane oxygenator instead of standard cardiopulmonary bypass during lung transplantation is debatable. Moreover, recently, the concept of prolonged postoperative extracorporeal membrane oxygenator (ECMO) support has been introduced in many transplant centers to prevent primary graft dysfunc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13628

    authors: Dell'Amore A,Campisi A,Congiu S,Mazzarra S,Pastore S,Dolci G,Baiocchi M,Frascaroli G

    更新日期:2020-06-01 00:00:00

  • Differentiation pattern of Vero cells cultured on poly(L-lactic acid)/poly(hydroxybutyrate-co-hydroxyvalerate) blends.

    abstract::This study evaluates the effect of poly(L-lactic acid) (PLLA) and poly(hydroxybutyrate-cohydroxyvalerate) (PHBV) bioabsorbable polymers and their blends on the induction of alteration of cell growth pattern in vitro. Vero cells were cultured on PLLA, PHBV, and different blends (100/0, 60/40, 50/50, 40/60, and 0/100). ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47199.x

    authors: Santos AR Jr,Ferreira BM,Duek EA,Dolder H,Wada RS,Wada ML

    更新日期:2004-04-01 00:00:00

  • Modified DALI LDL-apheresis using trisodium citrate anticoagulation plus bicarbonate or lactate-buffered hemofiltration substitution fluids as primers.

    abstract:BACKGROUND:DALI (direct adsorption of lipids) is the first LDL-apheresis technique able to adsorb low-density lipoprotein (LDL) and lipoproteina) directly from whole blood. In the standard procedure, acid citrate dextrose (ACD-A) is used as anticoagulation and the adsorber is rinsed with a specially manufactured primin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2003.07104.x

    authors: Bosch T,Wendler T,Maschke H

    更新日期:2003-06-01 00:00:00

  • Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.

    abstract::Neurologic complications during neonatal extracorporeal life support (ECLS) are associated with significant morbidity and mortality. Gaseous microemboli (GME) in the ECLS circuit may be a possible cause. Advances in neonatal circuitry may improve hemodynamic performance and GME handling leading to reduction in patient...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12908

    authors: Glass K,Trivedi P,Wang S,Woitas K,Kunselman AR,Ündar A

    更新日期:2017-04-01 00:00:00

  • Evaluation of the thrombogenicity of selected microporous oxygenator membranes.

    abstract::A comparative study of the thrombogenicity of several microporous membranes was performed using an ex vivo system simulating the conditions in an artificial lung. A study of platelet adhesion and adsorbed protein layer indicated that the membranes separated into three groups. Copolyurethane membranes adsorbed very few...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04343.x

    authors: Knight PM,Lyman DJ

    更新日期:1985-02-01 00:00:00

  • Substantial early loss of induced pluripotent stem cells following transplantation in myocardial infarction.

    abstract::The limited success of cardiac stem cell therapy has lately generated discussion regarding its effectiveness. We hypothesized that immediate cell loss after intramyocardial injection significantly obscures the regenerative potential of stem cell therapy. Therefore, our aim was to assess the distribution and quantity o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12268

    authors: Martens A,Rojas SV,Baraki H,Rathert C,Schecker N,Zweigerdt R,Schwanke K,Rojas-Hernandez S,Martin U,Saito S,Schmitto JD,Haverich A,Kutschka I

    更新日期:2014-11-01 00:00:00

  • Experiencing Functional Electrical Stimulation Roots on Education, and Clinical Developments in Paraplegia and Tetraplegia With Technological Innovation.

    abstract::Cybernetics-based concepts can allow for complete independence for paralyzed individuals, including sensory motor recovery. Spinal cord injuries are responsible for a huge stress on health and a financial burden to society. This article focuses on novel procedures such as functional diagnosis for paraplegics and tetra...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12620

    authors: Varoto R,Cliquet A Jr

    更新日期:2015-10-01 00:00:00

  • Modeling of a rotary blood pump.

    abstract::The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12142

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL

    更新日期:2014-03-01 00:00:00

  • Use of clinical guidelines for treatment of anemia among hemodialysis patients.

    abstract::Changing financial incentives have strongly influenced dosing patterns of recombinant human erythropoietin (rHuEPO) since its introduction in 1989. Although guidelines for prescribing rHuEPO exist, the extent to which they are adhered to is unknown. Using a retrospective cohort observational study design, the factors ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06495.x

    authors: Thamer M,Richard CM,Klinkmann J,Ivanovich P,Lang G,Cotter DJ

    更新日期:2000-02-01 00:00:00

  • Potential mechanisms for muscle-powered cardiac support.

    abstract::Biomechanical actuation of an implanted ventricular assist device (VAD) is an attractive means of providing long-term circulatory support. Studies show that energy from electrically stimulated skeletal muscle can, in principle, be used to provide tether-free cardiac assistance without the need for percutaneous driveli...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01170.x

    authors: Trumble DR

    更新日期:2011-07-01 00:00:00

  • Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model.

    abstract::We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13795

    authors: Ogawa D,Kobayashi S,Yamazaki K,Motomura T,Nishimura T,Shimamura J,Tsukiya T,Mizuno T,Takewa Y,Tatsumi E,Nishinaka T

    更新日期:2020-08-19 00:00:00