The impact of obesity on outcomes in patients receiving extracorporeal life support.

Abstract:

:Extracorporeal life support (ECLS) has been increasingly utilized to manage cardiac and pulmonary dysfunction. The impact of obesity on outcomes of ECLS is poorly defined. The purpose of the study was to compare in-hospital mortality, resource use, complications, and readmissions in obese versus non-obese patients receiving ECLS. We performed a retrospective cohort study of all adult ECLS patients with and without an obesity diagnosis using the 2010-2016 Nationwide Readmissions Database (NRD). Mortality, length of stay (LOS), hospital charges, complications, and readmissions were evaluated using multivariable logistic and linear regression. Of 23 876, patients who received ECLS, 1924 (8.1%) were obese. Obese patients received ECLS more frequently for respiratory failure (29.5% vs. 23.7%, P = .001). After adjustment for patient and hospital factors, obesity was not associated with increased odds of mortality (AOR = 1.06, P = .44) and was associated with decreased LOS (13.7 vs. 21.2 days, P < .001), hospital charges ($171 866 vs. $211 445, P < .001), and 30-day readmission (AOR = 0.71, P = .03). Obesity was also associated with reduced odds of hemorrhage (AOR = 0.43, P < .001), neurologic complications (AOR = 0.55, P = .004), and acute kidney injury (AOR=0.83, P = .04). After stratification by ECLS indication, obesity remained predictive of shorter LOS (AOR range: 0.53-0.78, all P < .05 ) and did not impact mortality (all P > .05). Respiratory support remains the most common indication for ECLS among obese patients. Among all patients, as well as by individual ECLS indication, obesity was not associated with increased odds of mortality. These findings suggest that obesity should not be considered a high-risk contraindication to ECLS.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Christian-Miller N,Hadaya J,Nakhla M,Sanaiha Y,Madrigal J,Emami S,Cale M,Sareh S,Benharash P

doi

10.1111/aor.13752

subject

Has Abstract

pub_date

2020-11-01 00:00:00

pages

1184-1191

issue

11

eissn

0160-564X

issn

1525-1594

journal_volume

44

pub_type

杂志文章
  • Electrotactile stimulator for artificial proprioception.

    abstract::With the goal of investigating artificial proprioception elicited by electrical stimulation, we have developed a tactile phi phenomenon-based stimulator. This two-channel microprocessed pulse amplitude modulation system generates two different envelope waveforms (triangular and elliptical) and allows programming and v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02318.x

    authors: Nohama P,Lopes AV,Cliquet Júnior A

    更新日期:1995-03-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • Prevention of right heart failure after left ventricular assist device implantation by phosphodiesterase 5 inhibitor.

    abstract::Right ventricular (RV) function immediately after left ventricular assist device (LVAD) implantation is a crucial prognostic factor. RV failure is linked to increased mortality and worse outcome. A phosphodiesterase 5 inhibitor, sildenafil, was shown to decrease pulmonary vascular resistance and pulmonary artery press...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12277

    authors: Hamdan R,Mansour H,Nassar P,Saab M

    更新日期:2014-11-01 00:00:00

  • A reduced priming system.

    abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2006.00275.x

    authors: Sato K,Namura O,Sogawa M,Shimada K,Tosaka Y,Hayashi J

    更新日期:2006-08-01 00:00:00

  • Venoarterial extracorporeal membrane oxygenation for postcardiotomy cardiogenic shock-A six-year service evaluation.

    abstract::Only a small number of English hospitals provide postcardiotomy venoarterial extracorporeal membrane oxygenation (VA-ECMO) and there are doubts about its efficacy and safety. The aim of this service evaluation was to determine local survival rates and report on patient demographics. This was a retrospective service ev...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13647

    authors: Charlesworth M,Garcia M,Head L,Barker JM,Ashworth AD,Barnard JB,Feddy L,Venkateswaran RV

    更新日期:2020-07-01 00:00:00

  • Is the New Infant Jarvik 2015 Suitable for Patients

    abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13302

    authors: Di Molfetta A,Zielinski K,Ferrari G,Kozarski M,Okrzeja P,Iacobelli R,Filippelli S,Perri G,Darowski M,Massetti M,Jarvik R,Amodeo A

    更新日期:2019-01-01 00:00:00

  • Can We Develop a Nonpulsatile Permanent Rotary Blood Pump? Yes, We Can.

    abstract::For many years, it was thought that nonpulsatile perfusion produced physiological and circulatory abnormalities. Since 1977, Yukihiko Nosé and his colleagues have challenged this misconception. Toward that end, they did show that if a 20% higher blood flow uses more than that required for a pulsatile blood pump, then ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04466.x

    authors: Nosé Y,Kawahito K,Nakazawa T

    更新日期:1996-05-01 00:00:00

  • A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs.

    abstract::A microcapsule suspension, a substitute for animal blood in hemolysis tests, has been developed for evaluation of the absolute hemolytic properties of circulatory artificial organs. The microcapsule suspension was made by dispersing microcapsule slurry into an ethylene glycol sodium chloride solution. The microcapsule...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06316.x

    authors: Maruyama O,Yamane T,Tsunemoto N,Nishida M,Tsutsui T,Jikuya T

    更新日期:1999-03-01 00:00:00

  • Application of a pressure-relieving air compliance chamber in a single-pulsatile extracorporeal life support system: an experimental study.

    abstract::Nonpulsatile blood pumps are mainly used in extracorporeal life support systems. Although pulsating blood flow is known to be physiological, a pulsatile pump is not commonly applied in a circuit with a membrane oxygenator because of damage to the blood cells. The hypothesis that the placement of a pressure-relieving c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07341.x

    authors: Kim TS,Sun K,Lee KB,Lee HW,Baek KJ,Park SY,Son HS,Kim KT,Kim HM

    更新日期:2004-12-01 00:00:00

  • Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

    abstract::This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlat...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13663

    authors: Nikfar M,Razizadeh M,Zhang J,Paul R,Wu ZJ,Liu Y

    更新日期:2020-08-01 00:00:00

  • Use of an integrated sideport for diagnosis and management of decreased flow rates in a programmable implanted insulin delivery system. Implantable Insulin Pump Trial Study Group.

    abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04586.x

    authors: Scavini M,Reich S,Eaton RP,Charles MA,Dunn FL

    更新日期:1996-09-01 00:00:00

  • The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump.

    abstract::A centrifugal blood pump with a double pivot impeller and an eccentric inlet port is being developed as an implantable artificial heart by the Baylor College of Medicine and Miwatec Co. Ltd. Flow visualization measurements were conducted to compare the flow around the pivot for two impeller operational modes: the top ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00155.x

    authors: Yamane T,Kodama T,Nishida M,Maruyama O,Yamamoto Y,Shinohara T,Motomura T,Nosé Y

    更新日期:2006-01-01 00:00:00

  • Application of computational fluid dynamics techniques to blood pumps.

    abstract::Present-day computational fluid dynamics (CFD) techniques can be used to analyze the behavior of fluid flow in a variety of pumps. CFD can be a powerful tool during the design stage for rapid virtual prototyping of different designs, analyzing performance parameters, and making design improvements. Computational flow ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Sukumar R,Athavale MM,Makhijani VB,Przekwas AJ

    更新日期:1996-06-01 00:00:00

  • Flow visualization study on centrifugal blood pump using a high speed video camera.

    abstract::Flow visualization is widely applied to evaluate rotary blood pumps; however, it is very difficult to visualize flow near the vanes of centrifugal blood pumps because the rotational speed of the impeller is usually several thousand rpm. In this study, a tracer method with a high speed video camera that can take more t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02399.x

    authors: Sakuma I,Tadokoro H,Fukui Y,Dohi T

    更新日期:1995-07-01 00:00:00

  • Cytotoxicity of two novel formulations of calcium phosphate cements: a comparative in vitro study.

    abstract::The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29022.x

    authors: Rossa C Jr,Marcantonio E Jr,Santos LA,Boschi AO,Raddi MS

    更新日期:2005-02-01 00:00:00

  • Simple evaluation method of biocompatibility of artificial oxygenator hollow fiber.

    abstract::We made miniature modules filled with artificial oxygenator hollow fibers and conducted a simple experiment to study the effect of different membrane structures on the blood. Three types of modules were made: one filled with polyolefin, one filled with polypropylene, and a blank module. The 3 modules were connected th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb00677.x

    authors: Nishida H,Shibuya M,Endo M,Koyanagi H

    更新日期:1996-12-01 00:00:00

  • Development of cellulose-DNA immunoadsorbent.

    abstract::The aim of this study was to prepare a DNA immunoadsorbent for the specific, extracorporeal removal of anti-DNA antibodies from the blood of patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA). Two kinds of cellulose beads were applied as a carrier. Calf thymus DNA was covalently coupled to ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06721.x

    authors: Kong D,Schuett W,Dai J,Kunkel S,Holtz M,Yamada R,Yu Y,Klinkmann H

    更新日期:2002-02-01 00:00:00

  • Peritoneal dialysis solutions for the 21st century.

    abstract::Existing peritoneal dialysis (PD) solutions were formulated for the maintenance of fluid and electrolyte balance, correction of metabolic acidosis, and the removal of metabolic waste products. Solutions currently in development are designed to improve biocompatibility by neutralizing pH and reducing glucose degradatio...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06022.x

    authors: Martis L,Chen C,Moberly JB

    更新日期:1998-01-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • Nonstimulated cardiomyoplasty improves hemodynamics in myocardial-infarcted rats.

    abstract::Cardiomyoplasty has been proposed as an alternative surgical treatment for congestive heart failure. The girdling effect of the muscle wrap is believed to reduce diastolic wall stress. We tested the hypothesis that nonstimulated or passive cardiomyoplasty (CDM) would reduce hemodynamic deficits in rats with experiment...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06907.x

    authors: De Angelis K,Leirner AA,Irigoyen MC,Cestari IA

    更新日期:2001-11-01 00:00:00

  • Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12359

    authors: Assmann A,Gül F,Benim AC,Joos F,Akhyari P,Lichtenberg A

    更新日期:2015-03-01 00:00:00

  • Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

    abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06594.x

    authors: Mesana T,Collart F,Caus T,Pomane C,Graziani N,Bruder N,Dufour H,Grisoli F,Montiès JR

    更新日期:2000-06-01 00:00:00

  • The impact of polyethylene glycol conjugation on bovine hemoglobin's circulatory half-life and renal effects in a rabbit top-loaded transfusion model.

    abstract::This study compares the effects of polyethylene glycol (PEG) modified bovine hemoglobin on vascular half-life and renal function in rabbits to those of unmodified bovine hemoglobin. Renal function was assessed by the measurement of the glomerular filtration rate, urinalysis, blood chemistries, hemoglobin (Hb) excretio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00250.x

    authors: Conover CD,Gilbert CW,Shum KL,Shorr RG

    更新日期:1997-08-01 00:00:00

  • Selective removal of anti-acetylcholine receptor antibodies and IgG in vitro with an immunoadsorbent containing immobilized sulfathiazole.

    abstract::Adsorption therapy, which treats the autoimmune disease by the selective removal of pathogenic substances from the blood, is an active subject. In this therapy, bioactive molecules such as antigen, antibodies and protein A are usually used as affinity-ligands. The disadvantages of using these substances as affinity-li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02977.x

    authors: Yamamoto Y,Sameshima T,Akaike T

    更新日期:1990-10-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation.

    abstract::Extracorporeal membrane oxygenation (ECMO) has long been the sole means of mechanical support for pediatric patients with end-stage cardiac failure, but has a high waitlist mortality and a reported survival to hospital discharge of less than 50%. The purpose of this study was to compare waitlist mortality and survival...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00969.x

    authors: Jeewa A,Manlhiot C,McCrindle BW,Van Arsdell G,Humpl T,Dipchand AI

    更新日期:2010-12-01 00:00:00

  • Phosphorylcholine and poly(D,L-lactic acid) containing copolymers as substrates for cell adhesion.

    abstract::Fibroblast cell culture was performed to evaluate cell adhesion and cell morphology on novel hydrolyzable copolymers composed of poly(D,L-lactic acid) (PDLA) macromonomer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and n-butyl methacrylate. The copolymers were used as cell culture materials for regulating the int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07015.x

    authors: Watanabe J,Ishihara K

    更新日期:2003-03-01 00:00:00

  • Adverse events of subcutaneous recombinant human erythropoietin therapy: results of a controlled multicenter European study.

    abstract::In a controlled European multicenter study, clinical tolerance of subcutaneously administered recombinant human erythropoietin (rh-EPO) therapy and its influence on the course of illness in 362 hemodialyzed patients (162 males, 200 females) from 16 European dialysis centers was studied. Of these, 181 patients served a...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1993.tb00571.x

    authors: Klinkmann H,Wieczorek L,Scigalla P