Abstract:
:Present-day computational fluid dynamics (CFD) techniques can be used to analyze the behavior of fluid flow in a variety of pumps. CFD can be a powerful tool during the design stage for rapid virtual prototyping of different designs, analyzing performance parameters, and making design improvements. Computational flow solutions provide information such as the location and size of stagnation zones and the local shear rate. These parameters can be correlated to the extent of hemolysis and thrombus formation and are critical to the success of a blood pump. CFD-ACE, an advanced commercial CFD code developed by CFD Research Corporation, has been applied to fluid flows in rotary machines, such as axial flow pumps and inducers. Preprocessing and postprocessing tools for efficient grid generation and advanced graphical flow visualization are integrated seamlessly with CFD-ACE. The code has structured multiblock grid capability, non-Newtonian fluid treatment, a variety of turbulence models, and an Eulerian-Langrangian particle tracking model. CFD-ACE has been used successfully to study the flow characteristics in an axial flow blood pump. An unstructured flow solver that greatly automates the process of grid generation and speeds up the flow simulation is under development.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Sukumar R,Athavale MM,Makhijani VB,Przekwas AJsubject
Has Abstractpub_date
1996-06-01 00:00:00pages
529-33issue
6eissn
0160-564Xissn
1525-1594journal_volume
20pub_type
杂志文章abstract::Visual prostheses are the focus of intensive research efforts to restore some measure of useful vision to blind or near-blind patients. The development of such technology is being guided to an extent by tools that simulate prosthesis behavior for healthy sighted subjects in order to assess system requirements and conf...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00878.x
更新日期:2010-05-01 00:00:00
abstract::Temporary extracorporeal membrane oxygenation (ECMO) has been established as an essential part of therapy in patients with pulmonary or cardiac failure. As physiological gaseous exchange is artificially altered in this patient group, it is debatable whether a (13) C-breath test can be carried out. In this proof of tec...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12634
更新日期:2016-07-01 00:00:00
abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00311.x
更新日期:1992-06-01 00:00:00
abstract::Implantation of left ventricular assist devices typically requires cardiopulmonary bypass support, which is associated with postoperative complications. A novel suture-less inflow cannula, which can be implanted without bypass, uses mild myocardial compression to seal the interface, however, this may lead to necrosis ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13018
更新日期:2018-05-01 00:00:00
abstract::Our study investigated the reliability of appearance of rapid atrial swirl flow (RASF) by ultrasonography (US) in the right atrium (RA), which occurred as a result of rapid isotonic saline infusion (RISI) into the central venous catheter (CVC), in predicting catheter tip position. This prospective observational study ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13281
更新日期:2018-12-01 00:00:00
abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02310.x
更新日期:1995-02-01 00:00:00
abstract::Bubble blood oxygenators equipped with baffles of various types in the oxygenating column were studied. The rate of hemolysis, the volumetric coefficient for oxygen absorption into blood, and the fractional gas holdup were found to be affected mainly by the superficial gas velocity. When compared with the conventional...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1979.tb01032.x
更新日期:1979-05-01 00:00:00
abstract::In a multicenter study including 5 dialysis units, blood acetate changes during 4 h dialysis sessions in 141 patients treated with a 4 mM acetate-containing bicarbonate dialysate (ABD) were evaluated and compared to the values of 114 patients using an acetate-free bicarbonate dialysate (AFD). Acetate-free bicarbonate ...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1046/j.1525-1594.1998.06205.x
更新日期:1998-07-01 00:00:00
abstract::Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the development of physiological control algorithms is accelerated with new evaluation environments. In this article, we present a novel hybrid mock circulation loop (HMCL) designed specifically for evaluation of rotary total artif...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12380
更新日期:2014-09-01 00:00:00
abstract::Using computed tomography (CT)-based preoperative planning software, we can define with good accuracy the position of a cementless hip stem inside the host bone, but previous studies suggest that the pose the surgeon achieves during freehand surgery may differ from the planned one even by some millimeters. Advances in...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00577.x
更新日期:2008-07-01 00:00:00
abstract::Ten dialysis patients were followed in a prospective study to determine the neurotoxicity of metabolites in the middle molecule (MM) molecular weight (mol wt) range of 500-200 daltons/molecule. In the absence of readily available direct serum measurements of MM concentrations, a theoretically calculated dialysis index...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1978.tb01002.x
更新日期:1978-02-01 00:00:00
abstract::This paper describes a new miniaturized implantable bladder controller that is composed of 4 main parts: a volume monitoring device based on the tomography approach, a fully programmable miniaturized central processor and stimulator, a bidirectional data and power link, and an external controller. The proposed system ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1997-03-01 00:00:00
abstract::The Genius is a convenient single-pass batch hemodialysis system. Dialysate is heated during the preparation phase. Once the container is filled at one of the three available starting temperatures, dialysate cools spontaneously. As dialysate temperature plays an important role in hemodynamic stability, knowledge of th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00981.x
更新日期:2010-12-01 00:00:00
abstract::Activated clotting time (ACT) is the most commonly used laboratory test to control the heparin effect during extracorporeal techniques. The study was undertaken in order to test in vitro the influence of heparin, platelet count, hematocrit, platelet fragmentation, and platelet activation on ACT. Blood was drawn from v...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06552.x
更新日期:2000-07-01 00:00:00
abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00735.x
更新日期:1997-05-01 00:00:00
abstract::Following implantation of a left ventricular assist device (LVAD), acceptable functional performance is now being achieved; however, peak VO2 and peak work load (watts) remain considerably limited. Maximum physical capacity is essentially dependent on generated cardiac output (CO) and arteriovenous oxygen difference (...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13102
更新日期:2018-07-01 00:00:00
abstract::We report on 10 patients with acute renal involvement in Hantaan virus infection observed at the Department of Nephrology, Faculty of Medicine, Skopje, Republic of Macedonia, during a period of 3 years (October 1987-July 1990). Eight patients were male and 2 were female, aged 37.5 +/- 4.8 years. The diagnosis of Hanta...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1995.tb02432.x
更新日期:1995-08-01 00:00:00
abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00924.x
更新日期:2010-02-01 00:00:00
abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1980.tb03894.x
更新日期:1980-02-01 00:00:00
abstract::EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system for supporting extremely premature infants that replicates in utero conditions by maintaining a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit connected to the umbilical vessels. Target g...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13524
更新日期:2019-12-01 00:00:00
abstract::The DexAide right ventricular assist device (RVAD) has been developed to provide an implantable RVAD option to surgeons. The aim of this study was to determine the optimal cannula design and optimal implantation location of the DexAide RVAD in preparation for its clinical use. Separately, a HeartMate XVE left ventricu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00438.x
更新日期:2007-08-01 00:00:00
abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12955
更新日期:2018-01-01 00:00:00
abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12390
更新日期:2015-04-01 00:00:00
abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00537.x
更新日期:1992-08-01 00:00:00
abstract::An important present and emerging trend in biomaterials development is the synthesis of polymers which combine capabilities of biologic recognition ("biomimetic") with sensitivity to small environmental changes ("stimuli-responsive"). This short article highlights some of the many opportunities and challenges in this ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1988.tb02813.x
更新日期:1988-12-01 00:00:00
abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1996.tb04586.x
更新日期:1996-09-01 00:00:00
abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.06931_4.x
更新日期:2002-08-01 00:00:00
abstract::A computational fluid dynamic model to assess the impact of flow-diverter device on intra-aneurysmal flow in complex aortic aneurysm from the viewpoint of hemodynamics is presented. The aim of this study is to investigate the hemodynamic effects of an endovascular flow-diverter technique using multiple overlapping unc...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12993
更新日期:2018-02-01 00:00:00
abstract::Our aim was to study the aging effects on the in vitro biological properties of bone marrow-derived mesenchymal stem cells (BMSCs) for construction of tissue-engineered heart valves. BMSCs were taken from teenagers with congenital heart diseases, and middle-aged and elderly patients with valvular diseases. Proliferati...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00824.x
更新日期:2010-03-01 00:00:00
abstract::We designed a 24-field array and an on-line control box that selects which and how many of 24 fields will conduct electrical charge during functional electrical stimulation. The array was made using a conductive microfiber textile, silver two-component adhesive, and the conductive ink imprint on the polycarbonate. The...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2005.29075.x
更新日期:2005-06-01 00:00:00