Is Multiple Overlapping Uncovered Stents Technique Suitable for Aortic Aneurysm Repair?

Abstract:

:A computational fluid dynamic model to assess the impact of flow-diverter device on intra-aneurysmal flow in complex aortic aneurysm from the viewpoint of hemodynamics is presented. The aim of this study is to investigate the hemodynamic effects of an endovascular flow-diverter technique using multiple overlapping uncovered stents (MOUS) in the treatment of complex aortic aneurysm involving side branch. The placement of porous barrier such as MOUS across the aneurysm alters the blood flow pattern in the aneurysm sac. Subsequently, flow diversion effect creates a natural hemodynamic environment to promote aneurysm thrombosis, thus stabilizing the aneurysm. The study revealed that intra-aneurysmal flow was reduced and low time average wall shear stress (TAWSS), high relative residence time (RRT), and high oscillatory shear index (OSI) regions were observed in the aneurysm sac. Three to four MOUS stents produced the best hemodynamic environment for the formation of thrombus, with saccular aneurysm performing better than fusiform aneurysm from the viewpoint of hemodynamics. A result also revealed that flow in the branch vessel was not compromised suggesting the capacity of preserving patency of branch vessels while at the same time stabilizing the aneurysm. Based on the hemodynamic performance of this study coupled with existing reported clinical studies, deploying three to four MOUS stents is a feasible solution to treat aneurysm with side branch, favorably for saccular shape aneurysm.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Yeow SL,Leo HL

doi

10.1111/aor.12993

subject

Has Abstract

pub_date

2018-02-01 00:00:00

pages

174-183

issue

2

eissn

0160-564X

issn

1525-1594

journal_volume

42

pub_type

杂志文章
  • Comparison of Centrifugal and Roller Pump Hemolysis Rates at Low Flow.

    abstract::We compared in vitro rates of hemolysis for a recently developed centrifugal pump with a conventional roller pump (10-10-00; Stöckert, Munich, Germany). Flow rates of 0.3 L/min and 1 L/min and a pressure of 200 mm Hg were chosen to simulate conditions during neonatal extracorporeal membrane oxygenation (ECMO). There w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04485.x

    authors: Moon YS,Ohtsubo S,Gomez MR,Moon JK,Nose Y

    更新日期:1996-05-01 00:00:00

  • Flow pattern analysis of the Baylor total artificial heart.

    abstract::To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03345.x

    authors: Meier D,Wernicke JT,Orime Y,Takatani S,Tasai K,Damm G,Naito K,Mizuguchi K,Makinouchi K,Glueck J

    更新日期:1994-12-01 00:00:00

  • Heat exchangers for cardioplegia systems: in vitro study of four different concepts.

    abstract::The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07240.x

    authors: Drummond M,Novello WP,de Arruda AC,Braile DM

    更新日期:2003-05-01 00:00:00

  • Electrochemical and Electrophysiological Performance of Platinum Electrodes Within the Ninety-Nine-Electrode Stimulating Nerve Cuff.

    abstract::The trend in neural prostheses using selective nerve stimulation for electrical stimulation therapies is headed toward single-part systems having a large number of working electrodes (WEs), each of which selectively stimulate neural tissue or record neural response (NR). The present article reviews the electrochemical...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12625

    authors: Pečlin P,Mehle A,Karpe B,Rozman J

    更新日期:2015-10-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • Dialysis and Patient Factors Which Determine Convective Volume Exchange in Patients Treated by Postdilution Online Hemodiafiltration.

    abstract::Recent reports suggest a survival advantage for dialysis patients treated by postdilutional online hemodiafiltration (OL-HDF) who achieve higher volume convective exchanges. As such, the factors associated with achieving higher convective volume exchange were determined. The convective exchange volumes during the midw...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12709

    authors: Davenport A

    更新日期:2016-12-01 00:00:00

  • Changes in albumin/platelet interaction with an artificial surface--due to a antibiotics, pyridoxal phosphate, and lymphocytes.

    abstract::Protein adsorption and platelet adhesion are two important biological processes arising at the blood prosthetic interface. The effect of certain antibiotics, namely, neomycin, gentamicin, ampicillin, penicillin-G, and streptomycin to modulate the albumin polycarbonate surface interaction was investigated using 125I al...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02747.x

    authors: Chandy T,Sharma CP

    更新日期:1988-04-01 00:00:00

  • Effects of pyridoxalated hemoglobin polyoxyethylene conjugate and other hemoglobin-related substances on arterial blood pressure in anesthetized and conscious rats.

    abstract::The effects of pyridoxalated hemoglobin polyoxyethylene conjugate (PHP) and other hemoglobin-related substances on arterial blood pressure (ABP) and heart rate (HR) were examined. Infusion of PHP and other hemoglobin-related substances elevated ABP and increased HR. The degree of the increase in ABP and HR did not dif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02300.x

    authors: Kida Y,Maeda M,Iwata S,Iwashita Y,Goto K,Nishi K

    更新日期:1995-02-01 00:00:00

  • Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery.

    abstract::Cardiopulmonary bypass (CPB) is a nonphysiologic environment for an organism. The damage of blood components may also lead to organ dysfunction, some-times recognized as postperfusion syndrome. One possible way to diminish the risk of these complications would be to reduce the thorombogenicity and to improve the bioco...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04573.x

    authors: Horimoto H,Kondo K,Asada K,Sasaki S

    更新日期:1996-08-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00

  • Hemodynamic evaluation of a new left ventricular assist device: an integrated cardioassist catheter as a pulsatile left ventricle-femoral artery bypass.

    abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00311.x

    authors: Ide H,Yamaguchi A,Ino T,Matsumoto H,Fujimasa I

    更新日期:1992-06-01 00:00:00

  • The application of immobilized enzymes in an artificial liver support system.

    abstract::A novel method of extracorporeal support for fulminant liver failure is reported whereby the most important detoxification processes of the liver are reproduced in an enzyme reactor. Most of the endogenous toxins involved in hepatic coma can be deactivated directly by conjugation with a hydrophilic residue such as glu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03801.x

    authors: Brunner G,Holloway CJ,Lösgen H

    更新日期:1979-02-01 00:00:00

  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • Assessment of total hip arthroplasty by means of computed tomography 3D models and fracture risk evaluation.

    abstract::Total hip arthroplasty (THA) can be achieved by using a cemented or noncemented prosthesis. Besides patient's age, weight, and other clinical signs, the evaluation of the quality of the bones is a crucial parameter on which orthopedic surgeons base the choice between cemented and noncemented THA. Although bone density...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12033

    authors: Gargiulo P,Pétursson T,Magnússon B,Bifulco P,Cesarelli M,Izzo GM,Magnúsdóttir G,Halldórsson G,Ludvigsdóttir GK,Tribel J,Jónsson H Jr

    更新日期:2013-06-01 00:00:00

  • Elective decompression of the left ventricle in pediatric patients may reduce the duration of venoarterial extracorporeal membrane oxygenation.

    abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12390

    authors: Hacking DF,Best D,d'Udekem Y,Brizard CP,Konstantinov IE,Millar J,Butt W

    更新日期:2015-04-01 00:00:00

  • The response of articular chondrocytes to type II collagen-Au nanocomposites.

    abstract::The nanocomposites (denoted "CII-Au") of porcine type II collagen (CII) with 0.05, 0.1, 0.5, 1, or 2.5% (wt/wt) Au nanoparticles ( approximately 5 nm) were fabricated for potential use in cartilage tissue engineering. Au formed clusters on the surface of all nanocomposites and appeared to distribute along the collagen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00482.x

    authors: Hsu SH,Yen HJ,Tsai CL

    更新日期:2007-12-01 00:00:00

  • Lixelle adsorbent to remove inflammatory cytokines.

    abstract::A beta2-microglobulin (beta2M) selective adsorbent (Lixelle) for direct hemoperfusion has been used for the treatment of hemodialysis patients with the long-term complication of dialysis related amyloidosis (DRA), but there is no significant correlation between the serum level of beta2M and the occurrence of DRA. Infl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06179.x

    authors: Tsuchida K,Takemoto Y,Nakamura T,Fu O,Okada C,Yamagami S,Kishimoto T

    更新日期:1998-12-01 00:00:00

  • Feasibility of extracorporeal on-line large-scale plasma adsorptions on protein A-sepharose columns in cancer patients.

    abstract::The feasibility of extracorporeal adsorption of 1.5-3 L plasma on protein A-Sepharose was investigated in six patients with advanced cancer. Anticoagulation with heparin was associated with respiratory distress syndrome in two patients, most likely caused by complement activation as indicated by a transient leukopenia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04247.x

    authors: Wallmark A,Grubb A,Freiburghaus C,Flodgren P,Husberg B,Lindholm T,Lindström C,Thysell H,Sjögren HO

    更新日期:1984-02-01 00:00:00

  • A percutaneously accessible pulsatile left ventricular assist device: modified assist device type 5.

    abstract::To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00718.x

    authors: Imanishi K,Imachi K,Yoshito H,Isoyama T,Abe Y,Chinzei T,Mabuchi K,Kanda K,Tsutsui N,Suma K,Fujimasa I

    更新日期:1996-02-01 00:00:00

  • Quantification of Shear-Induced Platelet Activation: High Shear Stresses for Short Exposure Time.

    abstract::Thrombosis and thromboembolism are the life-threatening clinical complications for patients supported or treated with prosthetic cardiovascular devices. The high mechanical shear stress within these devices is believed to be the major contributing factor to cause platelet activation (PA) and function alteration, leadi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12438

    authors: Ding J,Chen Z,Niu S,Zhang J,Mondal NK,Griffith BP,Wu ZJ

    更新日期:2015-07-01 00:00:00

  • Reversal of experimental posthepatectomy liver failure in pigs: a new application of hepatocyte bioreactors.

    abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01016.x

    authors: Arkadopoulos N,Kostopanagiotou G,Nastos C,Papalois A,Papoutsidakis N,Kalimeris K,Defterevos G,Kanna T,Polyzois K,Kampouroglou G,Kypriotis D,Costopanagiotou C,Pafiti A,Tzanatos H,Smyrniotis V

    更新日期:2011-01-01 00:00:00

  • Modified DALI LDL-apheresis using trisodium citrate anticoagulation plus bicarbonate or lactate-buffered hemofiltration substitution fluids as primers.

    abstract:BACKGROUND:DALI (direct adsorption of lipids) is the first LDL-apheresis technique able to adsorb low-density lipoprotein (LDL) and lipoproteina) directly from whole blood. In the standard procedure, acid citrate dextrose (ACD-A) is used as anticoagulation and the adsorber is rinsed with a specially manufactured primin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2003.07104.x

    authors: Bosch T,Wendler T,Maschke H

    更新日期:2003-06-01 00:00:00

  • Dialyzer membranes: effect of surface area and chemical modification of cellulose on complement and platelet activation.

    abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02648.x

    authors: Mahiout A,Meinhold H,Kessel M,Schulze H,Baurmeister U

    更新日期:1987-04-01 00:00:00

  • Fluid dynamic characteristics of the VentrAssist rotary blood pump.

    abstract::The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06584.x

    authors: Tansley G,Vidakovic S,Reizes J

    更新日期:2000-06-01 00:00:00

  • Investigation of parameter estimator and adaptive controller for assist pump by computer simulation.

    abstract::The multi-output adaptive controller of a left ventricular assist device (LVAD) was studied by computer simulation. The controller regulated two outputs--mean aortic pressure (mAoP) and mean atrial pressure (mLAP)--by regulating vacuum pressure (input). The autoregressive models were used to describe the circulatory s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1991.tb00769.x

    authors: Shimooka T,Mitamura Y,Yuhta T

    更新日期:1991-04-01 00:00:00

  • Computational flow optimization of rotary blood pump components.

    abstract::In an effort to improve and automate the fluid dynamic design of rotary blood pumps, a coupled computational fluid dynamics (CFD) shape optimization methodology has been developed and implemented. This program couples a finite element flow simulation with a gradient-based optimization routine to modify automatically t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02389.x

    authors: Antaki JF,Ghattas O,Burgreen GW,He B

    更新日期:1995-07-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Selective removal of anti-acetylcholine receptor antibodies and IgG in vitro with an immunoadsorbent containing immobilized sulfathiazole.

    abstract::Adsorption therapy, which treats the autoimmune disease by the selective removal of pathogenic substances from the blood, is an active subject. In this therapy, bioactive molecules such as antigen, antibodies and protein A are usually used as affinity-ligands. The disadvantages of using these substances as affinity-li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02977.x

    authors: Yamamoto Y,Sameshima T,Akaike T

    更新日期:1990-10-01 00:00:00

  • Effect of variation in systemic blood flow on plasma TNF-alpha in a pig model with left ventricular assist device.

    abstract::Tumor necrosis factor-alpha (TNF-alpha) release has been implicated in a sepsis-like syndrome following cardiopulmonary bypass (CPB). This also may be important in patients who have had a left ventricular assist device (LVAD) implanted. This report investigates the effect of reducing systemic blood flow on hemodynamic...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025002146.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-02-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00