Abstract:
:The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely large flow-blockage from impeller blades, low stiffness of bearings with concomitant impeller displacement under pulsatile load conditions, and very small running clearances. Low specific speed and radial blade off-flow were selected in order to minimize the hemolysis. Pulsatile and steady-flow tests show the impeller is stable under normal operating conditions. Computational fluid dynamics (CFD) has been used to optimize flow paths and reduce net axial force imbalance to acceptably small values. The latest design of the pump achieved a system efficiency of 18% (in 30% hematocrit of red blood cells suspended in phosphate-buffered saline), and efficiency was optimized over the range of operating conditions. Parameters critical to improving pump efficiency were investigated.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Tansley G,Vidakovic S,Reizes Jdoi
10.1046/j.1525-1594.2000.06584.xsubject
Has Abstractpub_date
2000-06-01 00:00:00pages
483-7issue
6eissn
0160-564Xissn
1525-1594pii
aor6584journal_volume
24pub_type
杂志文章abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03364.x
更新日期:1994-07-01 00:00:00
abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06594.x
更新日期:2000-06-01 00:00:00
abstract::This study evaluates the effect of poly(L-lactic acid) (PLLA) and poly(hydroxybutyrate-cohydroxyvalerate) (PHBV) bioabsorbable polymers and their blends on the induction of alteration of cell growth pattern in vitro. Vero cells were cultured on PLLA, PHBV, and different blends (100/0, 60/40, 50/50, 40/60, and 0/100). ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.47199.x
更新日期:2004-04-01 00:00:00
abstract::Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD inv...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12600
更新日期:2016-06-01 00:00:00
abstract::Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) wa...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12611
更新日期:2016-07-01 00:00:00
abstract::The aims of this study were to investigate whether introducing an interphase interval (IPI) to biphasic pulses during stimulation of the dorsiflexor muscles would affect force production and to determine whether the IPI effect is dependent on electrode position. Twelve healthy volunteers participated in the study. Eac...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12346
更新日期:2014-11-01 00:00:00
abstract::Extracorporeal human lymphatic organs are expected to be excellent tools in the study of human molecular and cellular bases of the immunologic balance and tissue harmony. A rational approach and process to design a device and a procedure to recreate the human lymph node environment in vitro is described with emphasis ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00303.x
更新日期:2006-10-01 00:00:00
abstract::Early in 1956, the first model of a biological artificial liver, using a live dog's liver incorporated in a cross-hemodialyzer, was placed in an experimental animal with portocaval encephalopathy. This "biological artificial liver," a hybrid artificial liver in the present terminology, was the first in the world. In O...
journal_title:Artificial organs
pub_type: 历史文章,杂志文章
doi:10.1111/j.1525-1594.1986.tb02548.x
更新日期:1986-06-01 00:00:00
abstract::Mesenchymal stem cells (MSCs) are regarded as a potential autologous source for cartilage repair, because they can differentiate into chondrocytes by transforming growth factor-beta (TGF-beta) treatment under the 3-dimensional (3-D) culture condition. However, more efficient and versatile methods for chondrogenic diff...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00288.x
更新日期:2006-09-01 00:00:00
abstract::The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrati...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03724.x
更新日期:1997-07-01 00:00:00
abstract::Cell-contracted collagen gels could provide rejection-free biomaterials for tissue engineering, but their application is limited by relatively low mechanical strength. We developed a special type I collagen construct (based on embedded fibroblasts) that was formed into a gel thread by using two anchors to constrain ge...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00314.x
更新日期:2006-11-01 00:00:00
abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06109.x
更新日期:1998-03-01 00:00:00
abstract::The use of electrical stimulation for denervated muscles is still considered to be a controversial issue by many rehabilitation facilities and medical professionals because prior clinical experience has shown that treating denervated muscle tissue using exponential current over a long time period constitutes an imposs...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06376.x
更新日期:1999-05-01 00:00:00
abstract::A beta2-microglobulin (beta2M) selective adsorbent (Lixelle) for direct hemoperfusion has been used for the treatment of hemodialysis patients with the long-term complication of dialysis related amyloidosis (DRA), but there is no significant correlation between the serum level of beta2M and the occurrence of DRA. Infl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06179.x
更新日期:1998-12-01 00:00:00
abstract::Thirteen percent of 99 patients undergoing maintenance hemodialysis showed an increased predialysis peripheral blood eosinophil count (mean value of 828 cells/mm3, range 410-2,710). Patients with eosinophilia were predominantly male and evidenced more frequent elevation of total plasma IgE levels. Otherwise, no differ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02635.x
更新日期:1987-04-01 00:00:00
abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01421.x
更新日期:2012-07-01 00:00:00
abstract::The cochlea is an end organ, which is metabolically dependent on a nutrient and oxygen supply to maintain its normal physiological function. Cochlear ischemia and reperfusion (IR) injury is considered one of the most important causes of human idiopathic sudden sensorineural hearing loss. The aim of the present study w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12863
更新日期:2017-08-01 00:00:00
abstract::A relative contraindication to intermittent peritoneal dialysis (IPD) is chronic lung disease. To evaluate whether the instillation of 2 L of fluid into the peritoneal cavity affects respiratory function, five IPD patients were studied in the supine position during the first 4 h of a routine IPD session. Blood gas ten...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1988.tb02768.x
更新日期:1988-06-01 00:00:00
abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04563.x
更新日期:1996-08-01 00:00:00
abstract::Artificial cells are prepared in the laboratory for medical and biotechnological applications. Encapsulated cells are being studied for the treatment of diabetes, liver failure, and other conditions. More recently, there have been extensive studies into the use of encapsulated genetically engineered cells for gene the...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06243.x
更新日期:1998-11-01 00:00:00
abstract::Solute clearance during high-flux hemodialysis is determined by the combined effects of solute convection and diffusion in the membrane, blood, and dialysate. Previous studies have focused almost entirely on the membrane transport phenomena, largely ignoring the potential contribution from bulk mass transport across t...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00403.x
更新日期:1993-11-01 00:00:00
abstract::To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04189.x
更新日期:1983-05-01 00:00:00
abstract::To evaluate their toxicity at the cellular level, middle molecules from uremic serum were incubated with erythrocytes from healthy subjects and the activity of the enzyme Delta-aminolevulinic acid dehydrase (D-ALA-D) and peroxidative hemolysis were investigated. Uremic middle molecules caused a significant decrease of...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1978.tb01626.x
更新日期:1978-11-01 00:00:00
abstract::Artificial oxygen (O2 ) carriers were reported to be protective in ischemia/reperfusion (I/R) in various organs including the heart. In the current study, 20 rats underwent ligation (MI) of the left anterior descending artery, were treated with 10 mL/kg of PEGylated carboxyhemoglobin bovine (SANGUINATE, S+, n = 10) or...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13384
更新日期:2018-12-01 00:00:00
abstract::Bone marrow mesenchymal stem cells (MSCs) have demonstrated their pluripotency to differentiate into different cell lineages and may be an alternative cell source for vascular tissue engineering. The objective of this study is to create small diameter vessels by seeding and culture of genetically modified MSCs onto a ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00322.x
更新日期:2006-12-01 00:00:00
abstract::Central extracorporeal life support (ECLS) is an effective treatment method of cardiogenic shock patients with or without lung failure. However, complications like infection and bleeding are common. The classical implantation approach requires full sternotomy, mobilization of the heart, with the well-known risks of bl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12344
更新日期:2015-02-01 00:00:00
abstract::Recently, there has been an increase in the use of rat models of cardiopulmonary bypass (CPB) for research purposes. Much of this work has focused on cerebral injury associated with CPB. Many of these studies employ a peripheral cannulation approach, often utilizing the caudal artery and internal or external jugular v...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00917.x
更新日期:2010-06-01 00:00:00
abstract::Two series of experiments were conducted to assess the potential of artificial ventricular bypass in restoring cardiac activity. One series evaluated use of a paracorporeal left ventricle in 17 calves; the other evaluated biventricular bypass in 11 calves. Module pumps with a seamless blood chamber of polyurethane wer...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02622.x
更新日期:1987-02-01 00:00:00
abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06397.x
更新日期:1999-06-01 00:00:00
abstract::We carried out this retrospective study to examine the magnesium status of our chronic ambulatory peritoneal dialysis (CAPD) patients dialyzed with 0.75 mmol/L (group I) or 0.50 mmol/L (group II) magnesium peritoneal dialysis solution. A total of 34 anuric patients on CAPD (age:31-72 years; duration of CAPD:7-74 month...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.07193.x
更新日期:2003-09-01 00:00:00