Respiratory gas exchange through the hydrophilic membrane.

Abstract:

:To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates of oxygen output obtained for a membrane fixed in the test chamber and those for a membrane inside the dialyzer showed that the performance of the membrane as an oxygen source in the latter arrangement is much poorer than that in the former one. This was attributed to the inadequate dialysate channel geometry of the dialyzer with respect to the catalytic reaction. However, the dialyzer geometry did not impede a quick removal of carbon dioxide. Washout of the catalyst (cobalt oxide) was observed. Hydrogen peroxide leakage to the blood side of the membrane was negligible.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Zborowski M

doi

10.1111/j.1525-1594.1983.tb04189.x

subject

Has Abstract

pub_date

1983-05-01 00:00:00

pages

221-6

issue

2

eissn

0160-564X

issn

1525-1594

journal_volume

7

pub_type

杂志文章
  • The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump.

    abstract:BACKGROUND:Ventricular assist devices are gaining ground in the therapeutic treatment of chronic heart failure. These devices are sometimes used as a bridge to recovery by unloading the left ventricle (LV) and restoring its function. It is therefore important to preserve the heart muscle and apply less invasive implant...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07374.x

    authors: Vandenberghe S,Nishida T,Segers P,Meyns B,Verdonck P

    更新日期:2004-07-01 00:00:00

  • Improved liver function following treatment with an extracorporeal liver assist device.

    abstract::A 68-year-old woman with fulminant hepatic failure of unknown etiology was treated with a bioartificial liver assist device. Prior to treatment, she had a number of clinical and laboratory features that suggested a hopeless outcome. Treatment was associated with a dramatic change in her mental status, and her clinical...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00381.x

    authors: Sussman NL,Kelly JH

    更新日期:1993-01-01 00:00:00

  • The E4T electric powered total artificial heart (TAH).

    abstract::The E4T is a totally implantable total artificial heart (TAH) resulting from many years of research work at the Cleveland Clinic Foundation (CCF) and Nimbus, Inc. It consists of four implanted subsystems: the pumping unit, the variable volume device, the transcutaneous transformer, and the internal battery. The pumpin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02795.x

    authors: Smith WA,Hete BF,Kiraly RJ,Fujimoto LK,Jacobs GB,Ishikawa M,Butler K,Nosé Y

    更新日期:1988-10-01 00:00:00

  • Fluid dynamic characteristics of the VentrAssist rotary blood pump.

    abstract::The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06584.x

    authors: Tansley G,Vidakovic S,Reizes J

    更新日期:2000-06-01 00:00:00

  • Evaluation of the thrombogenicity of selected microporous oxygenator membranes.

    abstract::A comparative study of the thrombogenicity of several microporous membranes was performed using an ex vivo system simulating the conditions in an artificial lung. A study of platelet adhesion and adsorbed protein layer indicated that the membranes separated into three groups. Copolyurethane membranes adsorbed very few...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04343.x

    authors: Knight PM,Lyman DJ

    更新日期:1985-02-01 00:00:00

  • Hybrid assembly of metal head and femoral stem from different manufacturers during isolated acetabular revision.

    abstract::During revision of a failed acetabular component with well-fixed antiquated femoral stem, the same variant of metal head is usually not available in the inventory production. We gathered the stems retrieved from revision surgeries and tried to reassemble with the commercially available femoral heads. This study report...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01015.x

    authors: Chen CF,Chen WM,Yang CT,Huang CK,Chen TH

    更新日期:2010-08-01 00:00:00

  • Stent treatment of inferior vena cava compression in an ovine with a total artificial heart.

    abstract::Although current continuous-flow total artificial hearts (CFTAHs) are much smaller than previous models, venous kinking may still occur after device implantation, especially in smaller animals. By inserting a self-expanding stent at the site of venous narrowing in a sheep model implanted with a CFTAH, we were able to ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01233.x

    authors: Tuzun E,Parnis S,Rios J,Winkler JA,Cohn WE

    更新日期:2011-07-01 00:00:00

  • Beta-2-microglobulin and main granulocyte components in hemodialysis patients.

    abstract::Plasma levels of granulocyte elastase in complex with alpha 1-proteinase inhibitor (E-alpha 1-PI) increased during hemodialysis from 110 +/- 10 to 506 +/- 66 micrograms/L using dialyzers made of polyamide, from 95 +/- 2.2 to 211 +/- 54 micrograms/ml with hemophane and from 114 +/- 10 to 203 +/- 25 using dialyzers made...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02842.x

    authors: Haag-Weber M,Schollmeyer P,Hörl WH

    更新日期:1989-04-01 00:00:00

  • Miniaturized centrifugal ventricular assist device for bridge to decision: Preclinical chronic study in a bovine model.

    abstract::We developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13459

    authors: Shimamura J,Mizuno T,Takewa Y,Tsukiya T,Naito N,Akiyama D,Iizuka K,Katagiri N,Nishimura T,Ono M,Tatsumi E

    更新日期:2019-09-01 00:00:00

  • Double-blind evaluation of plasmapheresis in schizophrenic patients: a pilot study.

    abstract::Interest in the effects and possible mechanisms of hemodialysis on schizophrenic patients has led to a double-blind evaluation of the effects of plasmapheresis on symptoms of schizophrenia. Also, plasmapheresis was felt to be an invaluable tool for investigating the autoimmune theory of schizophrenia. Patients (n = 10...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1983.tb04203.x

    authors: Schulz SC,van Kammen DP,Waters R,Klein HG,Balow JE,Bunney WE Jr

    更新日期:1983-08-01 00:00:00

  • The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

    abstract::Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged con...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00022.x

    authors: Mizuno T,Nishinaka T,Ohnishi H,Tatsumi E,Tsukiya T,Oshikawa M,Shioya K,Takewa Y,Homma A,Takano H,Kitamura S,Taenaka Y

    更新日期:2003-10-01 00:00:00

  • Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

    abstract::This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlat...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13663

    authors: Nikfar M,Razizadeh M,Zhang J,Paul R,Wu ZJ,Liu Y

    更新日期:2020-08-01 00:00:00

  • Replacing cardiopulmonary bypass with extracorporeal membrane oxygenation in lung transplantation operations.

    abstract::Cardiopulmonary bypass (CPB) is required in some lung transplantation (LTx) operations. However, it increases risks of bleeding and early graft dysfunction. We report our experiences of replacing CPB with heparin-bound extracorporeal membrane oxygenation (ECMO) in LTx operations. If extracorporeal circulation was anti...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025008607.x

    authors: Ko WJ,Chen YS,Lee YC

    更新日期:2001-08-01 00:00:00

  • Development of a composite degradable/nondegradable tissue-engineered vascular graft.

    abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00601.x

    authors: Tschoeke B,Flanagan TC,Cornelissen A,Koch S,Roehl A,Sriharwoko M,Sachweh JS,Gries T,Schmitz-Rode T,Jockenhoevel S

    更新日期:2008-10-01 00:00:00

  • Influence of middle molecules on the anemia of uremic patients.

    abstract::To evaluate their toxicity at the cellular level, middle molecules from uremic serum were incubated with erythrocytes from healthy subjects and the activity of the enzyme Delta-aminolevulinic acid dehydrase (D-ALA-D) and peroxidative hemolysis were investigated. Uremic middle molecules caused a significant decrease of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01626.x

    authors: Leber HW,Spiegelhalter R,Ulm A,Goubeaud G,Rawer P

    更新日期:1978-11-01 00:00:00

  • The mitroflow pericardial valve. First results of a follow-up study.

    abstract::One hundred eighty-eight Mitroflow pericardial valves, implanted on 166 patients from March 1983 to December 1986, have been followed for a total of 4316 patients x months. Mortality rate in the first three postoperative months is approximately 10% related to noncardiac complications. One hundred forty-nine patients a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02781.x

    authors: Loisance D,Hillion ML,Cachera JP

    更新日期:1988-08-01 00:00:00

  • Electrotactile stimulator for artificial proprioception.

    abstract::With the goal of investigating artificial proprioception elicited by electrical stimulation, we have developed a tactile phi phenomenon-based stimulator. This two-channel microprocessed pulse amplitude modulation system generates two different envelope waveforms (triangular and elliptical) and allows programming and v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02318.x

    authors: Nohama P,Lopes AV,Cliquet Júnior A

    更新日期:1995-03-01 00:00:00

  • Experimental high-volume hemofiltration with predilutional tris-hydroxymethylaminomethane for correction of low tidal volume ventilation-induced acidosis.

    abstract::The most common method of controlling acidemia during lung-protective ventilation is CO₂ removal with an extracorporeal lung assist (ECLA) system. Another possibility to prevent acidemia is based on intravenous (i.v.) application of tris-hydroxymethyl-aminomethane (3 mol/L, THAM) buffer, which can bind hydrogen proton...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01204.x

    authors: Russ M,Deja M,Ott S,Bedarf J,Keckel T,Hiebl B,Wagner JJ,Unger JK

    更新日期:2011-06-01 00:00:00

  • A compact mock circulation loop for the in vitro testing of cardiovascular devices.

    abstract::In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing. A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device's ability to treat pathological conditions. To serve this purpose, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01088.x

    authors: Timms DL,Gregory SD,Greatrex NA,Pearcy MJ,Fraser JF,Steinseifer U

    更新日期:2011-04-01 00:00:00

  • Re-endothelialization of non-detergent decellularized porcine vessels.

    abstract::Tissue engineering utilizes an interdisciplinary approach to generate constructs for the treatment and repair of diseased organs. Generation of small vessels as vascular grafts or as envisioned central vessel for vascularized constructs is still a challenge. Here, the decellularization of porcine vessels by a non-dete...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13836

    authors: Eyre K,Samper E,Haverich A,Hilfiker A,Andrée B

    更新日期:2020-10-01 00:00:00

  • Pulse conductance and flow-induced hemolysis during pulsatile cardiopulmonary bypass.

    abstract::In this study, the hypothesis was tested that a low-resistant, high-compliant oxygenator provides better pulse conductance and less hemolysis than a high-resistant, low-compliant oxygenator during pulsatile cardiopulmonary bypass. Forty adults undergoing coronary artery bypass surgery were randomly divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00853.x

    authors: Simons AP,Wortel P,van Kan RA,van der Veen FH,Weerwind PW,Maessen JG

    更新日期:2010-04-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Cytotoxicity of bile in human Hep G2 cells and in primary cultures of rat hepatocytes.

    abstract::There has been increasing interest in the development of a hepatocyte bioreactor for the treatment of acute hepatic failure; however, little is known about the effect of hepatocyte byproducts on the viability of the cells in the bioreactor environment. We investigated the effects of increasing concentrations of bile o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06088.x

    authors: Smirthwaite AD,Gaylor JD,Cousins RB,Grant MH

    更新日期:1998-10-01 00:00:00

  • Dialyzer reuse: interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing.

    abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04418.x

    authors: Ng YY,Yang AH,Wong KC,Lan HY,Hung TL,Kerr PG,Huang TP

    更新日期:1996-01-01 00:00:00

  • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

    abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06414.x

    authors: Wada H,Fukunaga S,Watari M,Sakai H,Sugawara Y,Ochikubo H,Imai K,Shibamura H,Orihashi K,Sueda T,Matsuura Y

    更新日期:1999-08-01 00:00:00

  • Comparison of rapid in situ, regular in situ, and ex vivo flushing on hepatic function.

    abstract::The efficacy of three flushing techniques on subsequent liver function was assessed using the in vivo isolated liver perfusion model (ILPM). Livers from brain-dead mongrel dogs were flushed with cold Euro-Collins as follows: Group I, rapid in situ flushing (10 min); Group II, regular in situ flushing (45 min); Group I...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02760.x

    authors: Castellanos J,Toledo-Pereyra LH,Finkelstein I,Kestenberg W,Chapman M,Choudhury S

    更新日期:1988-06-01 00:00:00

  • Dialyzer membranes: effect of surface area and chemical modification of cellulose on complement and platelet activation.

    abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02648.x

    authors: Mahiout A,Meinhold H,Kessel M,Schulze H,Baurmeister U

    更新日期:1987-04-01 00:00:00

  • Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation.

    abstract::Extracorporeal membrane oxygenation (ECMO) has long been the sole means of mechanical support for pediatric patients with end-stage cardiac failure, but has a high waitlist mortality and a reported survival to hospital discharge of less than 50%. The purpose of this study was to compare waitlist mortality and survival...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00969.x

    authors: Jeewa A,Manlhiot C,McCrindle BW,Van Arsdell G,Humpl T,Dipchand AI

    更新日期:2010-12-01 00:00:00

  • Significance of percutaneous cardiopulmonary bypass support for volume reduction surgery with severe hypercapnia.

    abstract::In patients with reduced respiratory function, lung resection is associated with high risk because separate ventilation is generally needed for safe management. For patients with end-stage emphysema, intraoperative respiratory management is important and particularly difficult because neither incomplete oxygenation no...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06339.x

    authors: Tsunezuka Y,Sato H,Tsubota M,Seki M