Double-blind evaluation of plasmapheresis in schizophrenic patients: a pilot study.

Abstract:

:Interest in the effects and possible mechanisms of hemodialysis on schizophrenic patients has led to a double-blind evaluation of the effects of plasmapheresis on symptoms of schizophrenia. Also, plasmapheresis was felt to be an invaluable tool for investigating the autoimmune theory of schizophrenia. Patients (n = 10) in the study fulfilled Research Diagnostic Criteria for schizophrenia and were randomly assigned to either sham or active plasmapheresis. They were blindly assessed by staff psychiatrists and nurses. Evaluation of the behavioral ratings revealed no significant decrease in psychosis for either the active or sham group. Also, no individual responding patient was identified. This finding complements our group's early negative results of a hemodialysis experiment and casts doubt on a simple autoimmune hypothesis of schizophrenia.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Schulz SC,van Kammen DP,Waters R,Klein HG,Balow JE,Bunney WE Jr

doi

10.1111/j.1525-1594.1983.tb04203.x

subject

Has Abstract

pub_date

1983-08-01 00:00:00

pages

317-21

issue

3

eissn

0160-564X

issn

1525-1594

journal_volume

7

pub_type

临床试验,杂志文章,随机对照试验
  • Paracorporeal artificial heart in postoperative heart failure.

    abstract::A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03465.x

    authors: Turina MT,Bosio R,Senning A

    更新日期:1978-08-01 00:00:00

  • Heart Transplant Waiting List Implications of Increased Ventricular Assist Device Use as a Bridge Strategy: A National Analysis.

    abstract:BACKGROUND:The use of ventricular assist devices (VAD) as a bridge to heart transplant (HT) is increasing, while HT volume remains stagnant. This may portend longer waiting times and an otherwise more competitive environment for all patients on the HT waiting list. METHODS:A retrospective analysis of patients who were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13833

    authors: Han JJ,Elzayn H,Duda MM,Iyengar A,Acker AM,Patrick WL,Helmers M,Birati EY,Atluri P

    更新日期:2020-10-01 00:00:00

  • Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

    abstract::In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06228.x

    authors: Mueller XM,Tevaearai HT,Hayoz D,von Segesser LK

    更新日期:1999-02-01 00:00:00

  • Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

    abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02200.x

    authors: Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

    更新日期:1994-04-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • Prevention of right heart failure after left ventricular assist device implantation by phosphodiesterase 5 inhibitor.

    abstract::Right ventricular (RV) function immediately after left ventricular assist device (LVAD) implantation is a crucial prognostic factor. RV failure is linked to increased mortality and worse outcome. A phosphodiesterase 5 inhibitor, sildenafil, was shown to decrease pulmonary vascular resistance and pulmonary artery press...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12277

    authors: Hamdan R,Mansour H,Nassar P,Saab M

    更新日期:2014-11-01 00:00:00

  • In Vitro Assessment of Electric Currents Increasing the Effectiveness of Vancomycin Against Staphylococcus epidermidis Biofilms.

    abstract::Biofilms are communities of bacteria that can cause infections which are resistant to the immune system and antimicrobial treatments, posing a significant threat for patients with implantable and indwelling medical devices. The purpose of our research was to determine if utilizing specific parameters for electric curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12678

    authors: Haddad PA,Mah TF,Mussivand T

    更新日期:2016-08-01 00:00:00

  • Beta-2-microglobulin and main granulocyte components in hemodialysis patients.

    abstract::Plasma levels of granulocyte elastase in complex with alpha 1-proteinase inhibitor (E-alpha 1-PI) increased during hemodialysis from 110 +/- 10 to 506 +/- 66 micrograms/L using dialyzers made of polyamide, from 95 +/- 2.2 to 211 +/- 54 micrograms/ml with hemophane and from 114 +/- 10 to 203 +/- 25 using dialyzers made...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02842.x

    authors: Haag-Weber M,Schollmeyer P,Hörl WH

    更新日期:1989-04-01 00:00:00

  • Artificial liver: present and future.

    abstract::Early in 1956, the first model of a biological artificial liver, using a live dog's liver incorporated in a cross-hemodialyzer, was placed in an experimental animal with portocaval encephalopathy. This "biological artificial liver," a hybrid artificial liver in the present terminology, was the first in the world. In O...

    journal_title:Artificial organs

    pub_type: 历史文章,杂志文章

    doi:10.1111/j.1525-1594.1986.tb02548.x

    authors: Hori M

    更新日期:1986-06-01 00:00:00

  • Fluid dynamic characteristics of the VentrAssist rotary blood pump.

    abstract::The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06584.x

    authors: Tansley G,Vidakovic S,Reizes J

    更新日期:2000-06-01 00:00:00

  • Use of an integrated sideport for diagnosis and management of decreased flow rates in a programmable implanted insulin delivery system. Implantable Insulin Pump Trial Study Group.

    abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04586.x

    authors: Scavini M,Reich S,Eaton RP,Charles MA,Dunn FL

    更新日期:1996-09-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Further development of hybrid functional electrical stimulation orthoses.

    abstract::In this study two aspects of hybrid functional electrical stimulation (FES) orthoses were investigated: joint motion constraints and FES control strategies. First, the effects of joint motion constraints on the gait of normal subjects were investigated using modern motion analysis systems, including electromyogram (EM...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb04648.x

    authors: Yang L,Granat MH,Paul JP,Condie DN,Rowley DI

    更新日期:1997-03-01 00:00:00

  • Anticoagulation with fondaparinux for hemodiafiltration in patients with heparin-induced thrombocytopenia: dose-finding study and safety evaluation.

    abstract::The optimal anticoagulation regimen for hemodialysis (HD) in patients with heparin-induced thrombocytopenia (HIT) has not been defined. Hemodiafiltration (HDF) adds a large convective component to HD, thereby changing the pharmacokinetics of most anticoagulants. Data on coagulation regimens for HDF are scant. We there...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12002

    authors: Mahieu E,Claes K,Jacquemin M,Evenepoel P,Op De Beek K,Bogaert AM,Kuypers D,Verhamme P,Meijers B

    更新日期:2013-05-01 00:00:00

  • In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.

    abstract::The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygen...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12912

    authors: Wang S,Caneo LF,Jatene MB,Jatene FB,Cestari IA,Kunselman AR,Ündar A

    更新日期:2017-09-01 00:00:00

  • The mitroflow pericardial valve. First results of a follow-up study.

    abstract::One hundred eighty-eight Mitroflow pericardial valves, implanted on 166 patients from March 1983 to December 1986, have been followed for a total of 4316 patients x months. Mortality rate in the first three postoperative months is approximately 10% related to noncardiac complications. One hundred forty-nine patients a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02781.x

    authors: Loisance D,Hillion ML,Cachera JP

    更新日期:1988-08-01 00:00:00

  • HandS ECMO: Preliminary Experience With "Hub and Spoke" Model in Neonates With Meconium Aspiration Syndrome.

    abstract::We aim to evaluate clinical outcomes of emergent extracorporeal membrane oxygenation (ECMO) implantation in newborns with life-threatening meconium aspiration syndrome (MAS) in peripheral hospitals with Hub and Spoke (HandS) setting. We retrospectively reviewed all neonates presenting with MAS, with no other comorbidi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13270

    authors: Fichera D,Zanella F,Fabozzo A,Doglioni N,Trevisanuto D,Lolli E,Vida V,Ceccherini E,Ebraico A,Stellin G,Padalino M

    更新日期:2019-01-01 00:00:00

  • Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers.

    abstract::We were encouraged to investigate the reasons for large amounts of foam observed in bloodlines during hemodialysis (HD). Foam was visible in the venous air trap within the Artis Gambro dialysis device. Estimates of the extent of foam were graded (0-no foam, 10-extensive foam) by two persons that were blind to the type...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13070

    authors: Jonsson P,Lindmark L,Axelsson J,Karlsson L,Lundberg L,Stegmayr B

    更新日期:2018-05-01 00:00:00

  • Chronic animal experiment with magnetically suspended centrifugal pump.

    abstract::We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03713.x

    authors: Yamada T,Nishimura K,Park CH,Kono S,Yuasa S,Tsukiya T,Akamatsu T,Matsuda K,Ban T

    更新日期:1997-07-01 00:00:00

  • A novel method to evaluate thromboresistance of drip chambers with filter used in extracorporeal blood circuits for hemodialysis.

    abstract::We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were for...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00354.x

    authors: Yamazaki M,Kobayashi K,Mori Y,Satoh T,Kubota S

    更新日期:1997-02-01 00:00:00

  • Effects of atrial arrhytmias on the regurgitation of a monoleaflet prosthetic heart valve.

    abstract::Many patients who receive a prosthetic heart valve also have or acquire cardiac arrhythmias. However, most in vitro studies of prosthetic valves examine them under normal rhythms. In this study, a monoleaflet prosthetic heart valve was tested in vitro under conditions that simulated normal sinus rhythm, first degree a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29101.x

    authors: Zapanta CM

    更新日期:2005-08-01 00:00:00

  • Impact of hemoglobin concentration and affinity for oxygen on tissue oxygenation: the case of hemoglobin-based oxygen carriers.

    abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01296.x

    authors: Samaja M,Terraneo L

    更新日期:2012-02-01 00:00:00

  • A novel in vitro assessment of tissue valve calcification by a continuous flow type method.

    abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06482-2.x

    authors: Park JC,Hwang YS,Han DW,Suh H

    更新日期:2000-02-01 00:00:00

  • Hypertension and end-stage renal disease in the developing world.

    abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07067.x

    authors: El-Khashab O

    更新日期:2002-09-01 00:00:00

  • Reversal of experimental posthepatectomy liver failure in pigs: a new application of hepatocyte bioreactors.

    abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01016.x

    authors: Arkadopoulos N,Kostopanagiotou G,Nastos C,Papalois A,Papoutsidakis N,Kalimeris K,Defterevos G,Kanna T,Polyzois K,Kampouroglou G,Kypriotis D,Costopanagiotou C,Pafiti A,Tzanatos H,Smyrniotis V

    更新日期:2011-01-01 00:00:00

  • Wear-Resistant, Hemocompatible Ti-Nb-Zr and Zr-Nb Alloys to Improve Blood Pump Design and Performance.

    abstract::Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04473.x

    authors: Davidson JA,Daigle KP,Kovacs P

    更新日期:1996-05-01 00:00:00

  • Engineering of vascular grafts with genetically modified bone marrow mesenchymal stem cells on poly (propylene carbonate) graft.

    abstract::Bone marrow mesenchymal stem cells (MSCs) have demonstrated their pluripotency to differentiate into different cell lineages and may be an alternative cell source for vascular tissue engineering. The objective of this study is to create small diameter vessels by seeding and culture of genetically modified MSCs onto a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00322.x

    authors: Zhang J,Qi H,Wang H,Hu P,Ou L,Guo S,Li J,Che Y,Yu Y,Kong D

    更新日期:2006-12-01 00:00:00

  • Ductular cholestasis, an unusual form of intrahepatic cholestasis, associated with cardiogenic shock and ventricular assist device.

    abstract::Ventricular assist devices have been shown to be effective in advanced heart failure selected patients. They often have borderline end-organ function, what facilitates organ dysfunction. Liver failure is difficult to manage and leads to increased morbidity and mortality. We report a case of ductular cholestasis, an un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00760.x

    authors: Mohedano-Gómez A,Pérez-Vela JL,Renes-Carreño E,De-Andrés CI,Corres-Peiretti MA,Arribas-López P,Gutierrez-Rodriguez J,Perales-Rodríguez-De-Viguri N

    更新日期:2010-02-01 00:00:00

  • Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump.

    abstract::A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male piv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.6184r.x

    authors: Takami Y,Yamane S,Makinouchi K,Niimi Y,Sueoka A,Nosé Y

    更新日期:1998-09-01 00:00:00

  • A hybrid mock circulation loop for a total artificial heart.

    abstract::Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the development of physiological control algorithms is accelerated with new evaluation environments. In this article, we present a novel hybrid mock circulation loop (HMCL) designed specifically for evaluation of rotary total artif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12380

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL,Frazier OH,Cohn WE

    更新日期:2014-09-01 00:00:00