Abstract:
:A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial heart has been used in four patients with refractory postoperative heart failure not responding to volume loading, pH and electrolyte correction, catecholamines and intra-aortic balloon pumping. Large cannulae were placed in the atria and great vessels. The ventricles were fixed on the chest paracorporeally. The assist system was used as a left heart bypass in one patient and as a biventricular bypass in three other patients. After 48-72 hours, the ventricular function recovered in three patients, permitting removal of the artificial heart. One patient died of cerebral complications six weeks later; the other two recovered completely and were released in good condition. Profound postoperative heart failure can be completely reversed by the use of the paracorporeal artificial heart; the advantage of the system lies in the simplicity of its implantation and removal.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Turina MT,Bosio R,Senning Adoi
10.1111/j.1525-1594.1978.tb03465.xsubject
Has Abstractpub_date
1978-08-01 00:00:00pages
273-6issue
3eissn
0160-564Xissn
1525-1594journal_volume
2pub_type
杂志文章abstract::From January 1980 through December 1990, implantation of a permanent pacemaker was performed in 34 patients following open heart surgery. The patients were divided into two groups according to the clinical indications for implantation of permanent pacemakers. Group 1 (9 patients) had surgical atrioventricular block, a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00591.x
更新日期:1993-05-01 00:00:00
abstract::Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. Even in the same deformation, the leaflets made in different tissue thickne...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12833
更新日期:2017-08-01 00:00:00
abstract::Left ventricle (LV) unloading caused by a left ventricular assist device (LVAD) has been shown to enhance reverse LV remodeling in end-stage cardiomyopathy. Several reports consistently suggest that a pulsatile-flow LVAD has more profound effects compared to continuous-flow LVAD, though the responsible mechanisms are ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13348
更新日期:2019-04-01 00:00:00
abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06062.x
更新日期:1998-12-01 00:00:00
abstract::In cardiac surgeries, it is frequently necessary to make the external blood circulation and oxygenation artificially. This procedure is called extracorporeal circulation (EC) or heart-lung bypass. During EC, one of the most important parameters, which demands continuous monitoring, is the blood flow. In many cases, th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06532.x
更新日期:2000-03-01 00:00:00
abstract::Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum veloc...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12653
更新日期:2016-05-01 00:00:00
abstract::Bicarbonate balance is usually calculated from the Henderson-Hasselbalch equation under the assumption that pK is constant. To evaluate the pK variability and its effects on bicarbonate computed with autoanalyzers in dialysis patients, we studied 44 patients on maintenance hemodialysis. The pH, PCO2, total CO2, and pK...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02715.x
更新日期:1987-12-01 00:00:00
abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06414.x
更新日期:1999-08-01 00:00:00
abstract::Total artificial hearts (TAHs) and biventricular assist devices (BVADs) have varying levels of acceptance and reliability, and the research on both focuses on their control mechanisms. Efforts generally aim to achieve a response to physiologic demand and left/right output balance, and beneficial cardiac output (CO) an...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04438.x
更新日期:1996-03-01 00:00:00
abstract::Lipid apheresis has developed from a heroic treatment into a routine clinical therapy and currently is the major indication for performing extracorporeal plasma therapy. Whereas it was once reserved for patients with homozygous familial hypercholesterolemia, today it has a place in the secondary prevention of severe c...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/j.1525-1594.1996.tb04525.x
更新日期:1996-05-01 00:00:00
abstract::The design criteria of an extracorporeal circuit suitable for pulsatile flow are quite different and more entangled than for steady flow. The time and costs of the design process could be reduced if mutual influences between the pulsatile pump and other extracorporeal devices were considered without experimental trial...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2003.47197.x
更新日期:2004-02-01 00:00:00
abstract::Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet n...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13507
更新日期:2019-11-01 00:00:00
abstract::Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mai...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06258.x
更新日期:1999-04-01 00:00:00
abstract::The sensitivity of liver allografts to even minimal periods of ischemia currently limits the duration of hepatic preservation prior to liver transplantation. This study evaluates the role of activated carbon hemoperfusion (ACH) for assisting the recovery of canine livers ischemically damaged by a 20-min occlusion of t...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1985.tb04386.x
更新日期:1985-08-01 00:00:00
abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:2001-04-01 00:00:00
abstract::What the most causative factor affecting hemolysis is still controversial. To resolve this problem, we investigated the relationship between hemolysis and heat generation in six types of centrifugal blood pumps (Bio-Pump, Delphin, Capiox, Nikkiso, Isoflow, and Toyobo). The analyzed parameters were index of hemolysis i...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02453.x
更新日期:1995-09-01 00:00:00
abstract::We recently experienced a case of a female hemodialysis patient with multiple intestinal angiodysplasias. In 2001, she complained of melena, and angiographic embolization halted bleeding from ileum angiodysplasia. In 2002, she again complained of black stool. Abdominal angiography found jejunum angiodysplasia, and pha...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.29003.x
更新日期:2005-01-01 00:00:00
abstract::Bubble blood oxygenators equipped with baffles of various types in the oxygenating column were studied. The rate of hemolysis, the volumetric coefficient for oxygen absorption into blood, and the fractional gas holdup were found to be affected mainly by the superficial gas velocity. When compared with the conventional...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1979.tb01032.x
更新日期:1979-05-01 00:00:00
abstract::In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12062
更新日期:2013-08-01 00:00:00
abstract::Implantation of left ventricular assist devices typically requires cardiopulmonary bypass support, which is associated with postoperative complications. A novel suture-less inflow cannula, which can be implanted without bypass, uses mild myocardial compression to seal the interface, however, this may lead to necrosis ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13018
更新日期:2018-05-01 00:00:00
abstract::This paper discussed issues of ethical assessment and moral concern associated with organ replacement and physical enhancement: research, allocation, organ donation, artificial organs, xenografts, biomaterials, and neuromaterials. While emphasizing the medical and moral benefits over associated risks, it calls for a b...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02362.x
更新日期:1995-05-01 00:00:00
abstract::The objective of this clinical study is to determine whether correlation exists among cerebral and renal near-infrared spectroscopy (NIRS) measurements, renal Doppler ultrasonography parameters (resistive index, peak systolic velocity), and early postoperative clinical outcomes following cardiac surgery in neonates an...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12455
更新日期:2015-01-01 00:00:00
abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02310.x
更新日期:1995-02-01 00:00:00
abstract::Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmo...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00452.x
更新日期:2008-01-01 00:00:00
abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00542.x
更新日期:2008-04-01 00:00:00
abstract::Myointimal hyperplasia (MIH) is an arterial wall smooth muscle cell (SMC) proliferative disorder. This process is responsible for a significant number of early and long-term arterial reconstructive and graft failures. Histopathologically, this process is characterized by a proliferation of SMC in the intima of traumat...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/j.1525-1594.1991.tb00758.x
更新日期:1991-02-01 00:00:00
abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00925.x
更新日期:2010-07-01 00:00:00
abstract::Two series of experiments were conducted to assess the potential of artificial ventricular bypass in restoring cardiac activity. One series evaluated use of a paracorporeal left ventricle in 17 calves; the other evaluated biventricular bypass in 11 calves. Module pumps with a seamless blood chamber of polyurethane wer...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02622.x
更新日期:1987-02-01 00:00:00
abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00537.x
更新日期:1992-08-01 00:00:00
abstract::Patients with end-stage renal disease have a very high prevalence and extent of arterial calcification. A number of studies suggest that similar pathophysiologic mechanisms are responsible for development and progression of calcification of atherosclerotic plaque and bone formation. Fetuin-A is a potent calcification ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00814.x
更新日期:2009-10-01 00:00:00