A novel method to evaluate thromboresistance of drip chambers with filter used in extracorporeal blood circuits for hemodialysis.

Abstract:

:We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were formed with 2 test circuits consisting of polyvinyl chloride tubing and two types of drip chambers with filters. Blood flow was derived into the drip chambers with a filter and returned to the femoral vein without using peristaltic pumps and systemic anticoagulants. By monitoring the quantitative changes of the blood flow rate through each drip chamber with a filter and measuring the time elapsed before the blood flow through its was completely obstructed by clots, thromboresistance of the drip chambers was evaluated under the same blood conditions. The drip chamber with a filter that had a small effective filter area, a big pore size, and slitlike pores showed better thromboresistance. This novel method proved useful in evaluating the thromboresistance of differently designed drip chambers with a filter.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Yamazaki M,Kobayashi K,Mori Y,Satoh T,Kubota S

doi

10.1111/j.1525-1594.1997.tb00354.x

subject

Has Abstract

pub_date

1997-02-01 00:00:00

pages

160-3

issue

2

eissn

0160-564X

issn

1525-1594

journal_volume

21

pub_type

杂志文章
  • A bedside micromethod for the determination of total carbon dioxide in biological fluids.

    abstract::The quality control of bicarbonate hemodialysis requires the determination of TCO2, either in blood or in dialysate. The use of the M + D TCO2 kit, a bedside micromethod, gave the authors an economical and reliable solution to this problem. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04404.x

    authors: Canaud B,Araujo A,Nguyen QV,Flavier JL,Mion C

    更新日期:1985-11-01 00:00:00

  • Pulsatile flow and simple flow control method during weaning period in centrifugal pump: toward more expanded usage in open heart surgery.

    abstract::To expand the usage of the centrifugal pump (CP) in open heart surgery, we performed two studies. In the first, we evaluated pulsatile flow in the CP. In vitro pump performance of the Terumo Capiox pump (TCP) and the Sarns Delphin pump (SDP) and increase of free hemoglobin (mg/dl) after driving 6 h were investigated u...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03393.x

    authors: Nishida H,Koyanagi H,Endo M,Suzuki S,Oshiyama H,Nojiri C,Fukasawa H,Akutsu T

    更新日期:1994-09-01 00:00:00

  • Is vecuronium toxicity abolished by hemodialysis? A case report.

    abstract::Vecuronium is a curaric agent, largely used in anesthesia. Indications as to its employ in uremic patients appear to be debated because of partial renal elimination of the drug. A 52-year-old hemodialyzed woman required transplantectomy for rejection. At awakeness after general anesthesia (induced with fentanyl, propo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06496.x

    authors: Rollino C,Visetti E,Borsa S,Pignataro A,Pozzato M,Vallero A,Quarello F

    更新日期:2000-05-01 00:00:00

  • The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.

    abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05074.x

    authors: Nawrat Z,Malota Z

    更新日期:1998-10-01 00:00:00

  • Extracorporeal membrane oxygenator compatible with centrifugal blood pumps.

    abstract::Coil-type silicone membrane oxygenators can only be used with roller blood pumps due to the resistance from the high blood flow. Therefore, during extracorporeal membrane oxygenation (ECMO) treatment, the combination of a roller pump and an oxygenator with a high blood flow resistance will induce severe hemolysis, whi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07117.x

    authors: Motomura T,Maeda T,Kawahito S,Matsui T,Ichikawa S,Ishitoya H,Kawamura M,Nishimura I,Shinohara T,Oestmann D,Glueck J,Kawaguchi Y,Sato K,Nosé Y

    更新日期:2002-11-01 00:00:00

  • Liposome encapsulated hemoglobin as a resuscitation fluid for hemorrhagic shock.

    abstract::The effectiveness of the blood substitute neo red cells (NRC) on hemorrhagic shock was evaluated in dogs. Shock was induced by bloodletting, and NRC was infused immediately until the dogs recovered from shock; the process was repeated 3 times (mild shock), or NRC was infused after shock was maintained for 30 min, and ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Usuba A,Osuka F,Kimura T,Sato R,Fujita Y,Yamashita M,Hoshino C

    更新日期:1998-02-01 00:00:00

  • Clinical long-term results of vascular prosthesis sealed with fragmented autologous adipose tissue.

    abstract::Tissue engineering can improve the former limitations of artificial organs. This article reports the long-term clinical results of grafts constructed with fragmented autologous adipose tissue. We did a retrospective analysis of a series of 53 patients with lower leg ischemia that received 69 fragmented adipose tissue ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025003218.x

    authors: Karube N,Soma T,Noishiki Y,Yamazaki I,Kosuge T,Ichikawa Y,Takanashi Y

    更新日期:2001-03-01 00:00:00

  • Cytotoxicity of two novel formulations of calcium phosphate cements: a comparative in vitro study.

    abstract::The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29022.x

    authors: Rossa C Jr,Marcantonio E Jr,Santos LA,Boschi AO,Raddi MS

    更新日期:2005-02-01 00:00:00

  • Pre- and postoperative magnetic resonance imaging in neonatal arterial switch operation using warm perfusion.

    abstract::Neurological morbidity is a major concern in pediatric cardiac surgery. Cardiopulmonary bypass is one of the few modifiable factors affecting neurodevelopmental outcome. This study aimed to measure the incidence of abnormalities apparent by magnetic resonance imaging (MRI) after neonatal arterial switch operation usin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01325.x

    authors: Durandy Y,Rubatti M,Couturier R,Rohnean A

    更新日期:2011-11-01 00:00:00

  • Expression of inflammation in myocardial tissue of rabbits: comparison of two miniaturized heart-lung machines.

    abstract::The majority of cases involving the surgical treatment of congenital heart disease require implementation of cardiopulmonary bypass (CPB). However, neonates and infants are particularly prone to serious complications associated with CPB as a result of capillary leak due to cardiovascular failure. These complications a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12025

    authors: Schnoering H,Arens J,Detering SM,Sachweh JS,Goetzenich A,Schmitz-Rode T,Steinseifer U,Vazquez-Jimenez JF

    更新日期:2013-06-01 00:00:00

  • Effects of atrial arrhytmias on the regurgitation of a monoleaflet prosthetic heart valve.

    abstract::Many patients who receive a prosthetic heart valve also have or acquire cardiac arrhythmias. However, most in vitro studies of prosthetic valves examine them under normal rhythms. In this study, a monoleaflet prosthetic heart valve was tested in vitro under conditions that simulated normal sinus rhythm, first degree a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29101.x

    authors: Zapanta CM

    更新日期:2005-08-01 00:00:00

  • Ripple reduction control of the undulation pump total artificial heart.

    abstract::An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06798.x

    authors: Saito I,Chinzei T,Mochizuki S,Abe Y,Isoyama T,Iwasaki K,Suzuki T,Karita T,Ono T,Kouno A,Ishimaru M,Baba A,Ozeki T,Tohyama T,Kobayashi Si S,Imachi K

    更新日期:2002-01-01 00:00:00

  • Ultrasonic pulsed Doppler blood flowmeter for use in extracorporeal circulation.

    abstract::In cardiac surgeries, it is frequently necessary to make the external blood circulation and oxygenation artificially. This procedure is called extracorporeal circulation (EC) or heart-lung bypass. During EC, one of the most important parameters, which demands continuous monitoring, is the blood flow. In many cases, th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06532.x

    authors: Dantas RG,Costa ET

    更新日期:2000-03-01 00:00:00

  • New immunosuppressive proteins (KX-2, -4, and -5) induced by liver transplantation.

    abstract::The presence in rat serum of three novel immunosuppressive proteins is associated with induction of tolerance after liver grafting. One of these, KX-5 (40 kilodalton molecular weight) is present 40-100 days after grafting of DA liver into PVG, a combination in which liver grafts are not rejected; two others, KX-2 (87 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00646.x

    authors: Kamada N

    更新日期:1996-10-01 00:00:00

  • Plasma middle molecules in asymptomatic and "sick" uremic patients.

    abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Asaba H,Bergström J,Fürst P,Johnson C,Yahiel V

    更新日期:1981-01-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • Biomechanical properties of decellularized porcine pulmonary valve conduits.

    abstract::Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00452.x

    authors: Seebacher G,Grasl C,Stoiber M,Rieder E,Kasimir MT,Dunkler D,Simon P,Weigel G,Schima H

    更新日期:2008-01-01 00:00:00

  • The BiVACOR rotary biventricular assist device: concept and in vitro investigation.

    abstract::The BiVACOR is a novel rotary Biventricular Assist Device (BiVAD) undergoing development to treat global end-stage heart failure. The design includes left and right vanes positioned on a shared rotating hub to form a double-sided magnetically and hydrodynamically suspended centrifugal impeller. The performance of the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00633.x

    authors: Timms D,Fraser J,Hayne M,Dunning J,McNeil K,Pearcy M

    更新日期:2008-10-01 00:00:00

  • Determination of plasma C3a des Arg levels after blood contact with foreign surfaces.

    abstract::The products of complement activation, including C3a, C4a, C5a, and their des Arg derivatives, have been used by many investigators as indicators of blood or foreign surface bioincompatibility, e.g., during hemodialysis. One problem encountered is that after extracorporeal circulation over some dialysis membranes very...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02518.x

    authors: Spencer PC,Schmidt B,Gurland HJ

    更新日期:1986-02-01 00:00:00

  • A comparative study between flow visualization and computational fluid dynamic analysis for the sun medical centrifugal blood pump.

    abstract::Flow visualization experiments and computational fluid dynamic (CFD) analyses were performed and the results were compared to clarify the detailed fluid dynamic characteristics for the prototype design of a centrifugal pump, namely, an implantable ventricular assist system from Sun Medical, whose hemocompatibility was...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07161.x

    authors: Yamane T,Miyamoto Y,Tajima K,Yamazaki K

    更新日期:2004-05-01 00:00:00

  • Dual-pump support in the inferior and superior vena cavae of a patient-specific fontan physiology.

    abstract::The implementation of simultaneous mechanical cavopulmonary assistance having blood pumps located in both of the vena cavae is investigated as an approach to treating patients with an ailing Fontan physiology. Identical intravascular blood pumps are employed to model the hemodynamic support of a patient-specific Fonta...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12039

    authors: Throckmorton AL,Lopez-Isaza S,Moskowitz W

    更新日期:2013-06-01 00:00:00

  • The PediPump: a new ventricular assist device for children.

    abstract::Options for mechanical circulatory support for the treatment of end-stage heart failure in children are limited. Ventricular assist devices (VADs), which have revolutionized cardiac care in adults, remain largely unavailable for pediatric applications. The PediPump is a new rotary dynamic VAD designed to provide suppo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29088.x

    authors: Duncan BW,Lorenz M,Kopcak MW,Fukamachi K,Ootaki Y,Chen HM,Chapman PA,Davis SJ,Smith WA

    更新日期:2005-07-01 00:00:00

  • An in vitro investigation into the hemodynamic effects of orifice geometry and position on left ventricular vortex formation and turbulence intensity.

    abstract::In a healthy human cardiac system, a large asymmetric clockwise vortex present in the left ventricle (LV) efficiently diverts the filling jet from the mitral annulus to the left ventricular outflow track. However, prior clinical studies have shown that artificial mitral valve replacement can affect the formation of ph...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13781

    authors: Tan SG,Hon JKF,Nguyen YN,Kim S,Leo HL

    更新日期:2020-12-01 00:00:00

  • Effect of a balanced biventricular bypass system on left ventricular energies.

    abstract::Left dominant biventricular failure is a common type of heart failure after cardiac surgery. We developed a biventricular bypass (BVB) system for treatment of postcardiotomy ventricular failure, and we previously reported that the clinical results of the BVB system were superior to those obtained with venoarterial byp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06015.x

    authors: Kodera K,Kitamura M,Shibuya M,Kurihara H,Koyanagi H

    更新日期:1998-09-01 00:00:00

  • A reduced priming system.

    abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2006.00275.x

    authors: Sato K,Namura O,Sogawa M,Shimada K,Tosaka Y,Hayashi J

    更新日期:2006-08-01 00:00:00

  • Sensitivity of the primary stability of a cementless hip stem to its position and orientation.

    abstract::Using computed tomography (CT)-based preoperative planning software, we can define with good accuracy the position of a cementless hip stem inside the host bone, but previous studies suggest that the pose the surgeon achieves during freehand surgery may differ from the planned one even by some millimeters. Advances in...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00577.x

    authors: Reggiani B,Cristofolini L,Taddei F,Viceconti M

    更新日期:2008-07-01 00:00:00

  • Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing.

    abstract::To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We st...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00244.x

    authors: Dobsák P,Novakova M,Baba A,Vasku J,Isoyama T,Saito I,Abe Y,Chinzei T,Imachi K

    更新日期:2006-06-01 00:00:00

  • Preservation of human saphenous vein against reactive oxygen species-induced oxidative stress by green tea polyphenol pretreatment.

    abstract::The injurious effects of reactive oxygen species on venous tissues and the potential protective role played by green tea polyphenol (GTPP) on human saphenous veins were investigated. Oxidative stress was induced exogenously in the vein segments, either by adding 0.8 or 1.6 M of H2O2, or by using 80 or 160 U/L of xanth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07163.x

    authors: Han DW,Suh H,Park YH,Cho BK,Hyon SH,Park JC

    更新日期:2003-12-01 00:00:00

  • The need for standardizing the index of hemolysis.

    abstract::Hemolysis is one of the most important performance parameters of blood pumps. However, comparative in vitro evaluation of the reported hemolysis effect is difficult owing to the lack of uniformity in the test methods used. Currently, three types of formulas are generally accepted and widely used for the index of hemol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03292.x

    authors: Naito K,Mizuguchi K,Nosé Y

    更新日期:1994-01-01 00:00:00

  • Numerical estimation of hemolysis from the point of view of signal and system.

    abstract::The power-law based models for predicting shear-induced hemolysis are widely used in the optimization design of blood-contacting devices. However, this category of models has fallen short of accuracy when compared with the results of the in vitro experiments. The aim of this study is to develop an alternative model fr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12294

    authors: Li H,Ruan X,Qian W,Fu X

    更新日期:2014-12-01 00:00:00