In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.

Abstract:

:The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygenator or a Maquet Quadrox-I Pediatric oxygenator without integrated arterial filter (parallel arrangement), 1/4 in. ID tubing A-V loop, and a 12-Fr arterial cannula, primed with lactated Ringer's solution and packed red blood cells. Trials were conducted at flow rates ranging from 500 to 2000 mL/min (500 mL/min increment) at 35°C and 28°C. Real-time pressure and flow data were recorded using a custom-based data acquisition system. For GME testing, 5 cc of air was manually injected into the venous line. GME were recorded using the Emboli Detection and Classification Quantifier (EDAC) System. An additional experiment using a separate arterial filter was conducted. There was no difference in the mean circuit pressure, pressure drop, total hemodynamic energy level, and energy loss between the two oxygenators. The venous line pressures were higher in the Braile than in the Quadrox group during all trials (P <0.01). GME count and volume at pre-/post oxygenator and pre-cannula sites in the Quadrox were lower than the Braile group at high flow rates (P < 0.05). In the additional experiment, an arterial filter captured a significant number of microemboli at all flow rates. The Braile Infant oxygenator has a matched hemodynamic characteristic with the Quadrox-i Pediatric oxygenator. The Quadrox-i has a better GME handling ability compared with the Braile Infant oxygenator. Regardless of type of oxygenator an additional arterial filter decreases the number of GME.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Wang S,Caneo LF,Jatene MB,Jatene FB,Cestari IA,Kunselman AR,Ündar A

doi

10.1111/aor.12912

subject

Has Abstract

pub_date

2017-09-01 00:00:00

pages

865-874

issue

9

eissn

0160-564X

issn

1525-1594

journal_volume

41

pub_type

杂志文章,多中心研究
  • Cytotoxicity and genotoxicity of bovine pericardium preserved in glycerol.

    abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00542.x

    authors: Rodas AC,Maizato MJ,Leirner AA,Pitombo RN,Polakiewicz B,Beppu MM,Higa OZ

    更新日期:2008-04-01 00:00:00

  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00

  • Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design.

    abstract::Planar particle image velocimetry was used to explore the flow behavior of the newly designed 12-cc Penn State pneumatic pediatric assist pump. Wall shear maps complemented the velocity data. Bjork-Shiley Monostrut 17-mm mechanical heart valves were used in the inlet and outlet ports. In comparison with larger Penn St...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00565.x

    authors: Manning KB,Wivholm BD,Yang N,Fontaine AA,Deutsch S

    更新日期:2008-06-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • Promigratory activity of oxytocin on umbilical cord blood-derived mesenchymal stem cells.

    abstract::Recent studies show that oxytocin has various effects on cellular behaviors. Oxytocin is reported to stimulate cardiomyogenesis of embryonic stem cells and endothelial cell proliferation. Mesenchymal stem cells (MSCs) are widely used for cardiac repair, and we elucidated the effect of oxytocin on umbilical cord derive...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00894.x

    authors: Kim YS,Kwon JS,Hong MH,Kim J,Song CH,Jeong MH,Cho JG,Park JC,Kang JC,Ahn Y

    更新日期:2010-06-01 00:00:00

  • Numerical estimation of hemolysis from the point of view of signal and system.

    abstract::The power-law based models for predicting shear-induced hemolysis are widely used in the optimization design of blood-contacting devices. However, this category of models has fallen short of accuracy when compared with the results of the in vitro experiments. The aim of this study is to develop an alternative model fr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12294

    authors: Li H,Ruan X,Qian W,Fu X

    更新日期:2014-12-01 00:00:00

  • Judicious usage of estrogen/progesterone for angiodysplasia.

    abstract::We recently experienced a case of a female hemodialysis patient with multiple intestinal angiodysplasias. In 2001, she complained of melena, and angiographic embolization halted bleeding from ileum angiodysplasia. In 2002, she again complained of black stool. Abdominal angiography found jejunum angiodysplasia, and pha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29003.x

    authors: Takenaka T,Kanno Y,Suzuki H

    更新日期:2005-01-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Effect of age on calcification of poly(hydroxyethyl methacrylate) in animals.

    abstract::The effect of age on the calcification of biomaterials was studied by the subcutaneous implantation of poly(hydroxyethyl methacrylate) hydrogel in rats. The hydrogel sheets were implanted in rats 6, 12, 24, and 52 weeks (1 year) of age. The retrieved implants were compared and the percentage weight increase by mineral...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04388.x

    authors: Imai Y

    更新日期:1985-08-01 00:00:00

  • The mitroflow pericardial valve. First results of a follow-up study.

    abstract::One hundred eighty-eight Mitroflow pericardial valves, implanted on 166 patients from March 1983 to December 1986, have been followed for a total of 4316 patients x months. Mortality rate in the first three postoperative months is approximately 10% related to noncardiac complications. One hundred forty-nine patients a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02781.x

    authors: Loisance D,Hillion ML,Cachera JP

    更新日期:1988-08-01 00:00:00

  • Influence of middle molecules on the anemia of uremic patients.

    abstract::To evaluate their toxicity at the cellular level, middle molecules from uremic serum were incubated with erythrocytes from healthy subjects and the activity of the enzyme Delta-aminolevulinic acid dehydrase (D-ALA-D) and peroxidative hemolysis were investigated. Uremic middle molecules caused a significant decrease of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01626.x

    authors: Leber HW,Spiegelhalter R,Ulm A,Goubeaud G,Rawer P

    更新日期:1978-11-01 00:00:00

  • A novel method to evaluate thromboresistance of drip chambers with filter used in extracorporeal blood circuits for hemodialysis.

    abstract::We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were for...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00354.x

    authors: Yamazaki M,Kobayashi K,Mori Y,Satoh T,Kubota S

    更新日期:1997-02-01 00:00:00

  • Extracorporeal membrane oxygenator compatible with centrifugal blood pumps.

    abstract::Coil-type silicone membrane oxygenators can only be used with roller blood pumps due to the resistance from the high blood flow. Therefore, during extracorporeal membrane oxygenation (ECMO) treatment, the combination of a roller pump and an oxygenator with a high blood flow resistance will induce severe hemolysis, whi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07117.x

    authors: Motomura T,Maeda T,Kawahito S,Matsui T,Ichikawa S,Ishitoya H,Kawamura M,Nishimura I,Shinohara T,Oestmann D,Glueck J,Kawaguchi Y,Sato K,Nosé Y

    更新日期:2002-11-01 00:00:00

  • Low-intensity ultrasound stimulation enhances chondrogenic differentiation in alginate culture of mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are regarded as a potential autologous source for cartilage repair, because they can differentiate into chondrocytes by transforming growth factor-beta (TGF-beta) treatment under the 3-dimensional (3-D) culture condition. However, more efficient and versatile methods for chondrogenic diff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00288.x

    authors: Lee HJ,Choi BH,Min BH,Son YS,Park SR

    更新日期:2006-09-01 00:00:00

  • Regenerative medicine for cardiovascular disorders-new milestones: adult stem cells.

    abstract::Cardiovascular disorders are the leading causes of mortality and morbidity in the developed world. Cell-based modalities have received considerable scientific attention over the last decade for their potential use in this clinical arena. This review was intended as a brief overview on the subject of therapeutic potent...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2006.00209.x

    authors: Akar AR,Durdu S,Corapcioglu T,Ozyurda U

    更新日期:2006-04-01 00:00:00

  • Comparison between standard single chamber versus dual chamber low glucose degradation product peritoneal dialysis fluids.

    abstract::Dual chamber (DC) peritoneal dialysis (PD) dialysates contain fewer glucose degradation products (GDPs), so potentially reducing advanced glycosylation end products (AGEs), which have been reported to increase inflammation and cardiovascular risk. We wished to determine whether use of DC dialysates resulted in demonst...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13768

    authors: Vareesangthip K,Vongsanim S,Fan S,Davenport A

    更新日期:2020-07-09 00:00:00

  • Flow through an outlet cannula of a rotary ventricular assist device.

    abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06931_4.x

    authors: Manning KB,Miller GE

    更新日期:2002-08-01 00:00:00

  • Combining novel biomolecules and stimuli-sensitive biomaterials into new recognition-response biomaterial systems.

    abstract::An important present and emerging trend in biomaterials development is the synthesis of polymers which combine capabilities of biologic recognition ("biomimetic") with sensitivity to small environmental changes ("stimuli-responsive"). This short article highlights some of the many opportunities and challenges in this ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02813.x

    authors: Hoffman AS

    更新日期:1988-12-01 00:00:00

  • Intravenous prostacyclin mitigates inhaled nitric oxide rebound effect: A case control study.

    abstract::Although extracorporeal membrane oxygenation (ECMO) improves oxygenation, pulmonary vascular resistance may be increased due to endothelial function impairment. Inhaled nitric oxide (iNO) is increasingly used for treatment of pulmonary hypertension after surgical repair of congenital heart defects, with or without ECM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06448.x

    authors: Hermon M,Golej J,Burda G,Marx M,Trittenwein G,Pollak A

    更新日期:1999-11-01 00:00:00

  • A New 2D Echocardiographic Approach to Evaluate the Membrane and Valve Movement of the Berlin Heart EXCOR VAD Chamber in Pediatric VAD Patients.

    abstract::The use of Berlin Heart EXCOR VAD (BH) is a validated therapy to bridge pediatric patients to heart transplant. Serial echocardiographic (ECHO) assessment of VAD patients is necessary to support patients' management. This work aims at developing an innovative strategy to evaluate the BH device functioning by ECHO and ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13122

    authors: Di Molfetta A,Iacobelli R,Ferrari G,Filippelli S,Perri G,Toscano A,Adorisio R,Guccione P,Amodeo A

    更新日期:2018-04-01 00:00:00

  • Clinical evaluation of a new type of centrifugal pump.

    abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03403.x

    authors: Ninomiya J,Shoji T,Tanaka S,Ikeshita M,Ochi M,Yamauchi S,Yajima T,Yamauchi H,Sugimoto T,Aizawa T

    更新日期:1994-09-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Research into the development of a wearable bioartificial kidney with a continuous hemofilter and a bioartificial tubule device using tubular epithelial cells.

    abstract::Current hemodialysis treatment is insufficient because of intermittent treatment and loss of tubular function. In order to overcome the loss of tubular function, a bioartificial kidney has been developed consisting of continuous hemofiltration (CHF) with 10 L/day of filtrate and a bioartificial tubule device using pro...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2004.07323.x

    authors: Saito A

    更新日期:2004-01-01 00:00:00

  • A novel, valveless ventricular assist device: the FishTail pump. First experimental in vivo studies.

    abstract::This article presents the first in vivo experiments with a new type of valveless ventricular assist device, a wave-generating pump. Our goal was to evaluate the hemodynamic performance of the pump by comparing it with the Biomedicus BP-80 centrifugal pump and by sustaining a 3 h long left ventricular assistance. We co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06973.x

    authors: Feier H,Mekkaoui C,Drevet JB,Sérée Y,Richomme C,Rolland PH,Mesana TG

    更新日期:2002-12-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • Severe meprobamate intoxication treated by hemoperfusion over amberlite resin.

    abstract::A 36-year-old female was treated successfully by hemoperfusion over Amberlite XAD-4 resin after ingestion of 40 gm of meprobamate. Hemoperfusion was started five hours after the ingestion. At that time the patient was in deep coma. The patient was treated by hemoperfusion for five hours, at the end of which time she w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Freund LG

    更新日期:1981-02-01 00:00:00

  • Numerical simulations of blood flow in artificial and natural hearts with fluid-structure interaction.

    abstract::This article describes two ongoing numerical studies of fluid-structure interaction in the cardiovascular system: an idealized pulsatile ventricular assist device (VAD), consisting of two fluid chambers separated by a flexible diaphragm; and blood flow and heart wall motion during passive filling of a canine heart. Si...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00644.x

    authors: Doyle MG,Vergniaud JB,Tavoularis S,Bourgault Y

    更新日期:2008-11-01 00:00:00

  • The monomeric formulation optimization of dental composite: mechanical and kinetic studies.

    abstract::The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07250.x

    authors: López Palacio RE,de Carvalho Zavaglia CA

    更新日期:2003-05-01 00:00:00

  • Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle.

    abstract::Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mai...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06258.x

    authors: Lanmüller H,Sauermann S,Unger E,Schnetz G,Mayr W,Bijak M,Girsch W

    更新日期:1999-04-01 00:00:00