The monomeric formulation optimization of dental composite: mechanical and kinetic studies.

Abstract:

:The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such as initiator, accelerator, and macro-components composition were optimized. The infrared spectroscopy was the analytical technique used in the kinetic study. On the mechanical characterization, the stress strain, flexure stress and its modulus, were the properties analyzed. The dependency between the polymeric reaction and the physical behavior of the composites and the monomer composition was observed and studied. Finally, the monomer optimum composition was determined.

journal_name

Artif Organs

journal_title

Artificial organs

authors

López Palacio RE,de Carvalho Zavaglia CA

doi

10.1046/j.1525-1594.2003.07250.x

subject

Has Abstract

pub_date

2003-05-01 00:00:00

pages

419-23

issue

5

eissn

0160-564X

issn

1525-1594

pii

7250

journal_volume

27

pub_type

杂志文章
  • Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

    abstract::A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06130.x

    authors: Wakisaka Y,Okuzono Y,Taenaka Y,Chikanari K,Endo S,Masuzawa T,Takano H

    更新日期:1998-06-01 00:00:00

  • Diabetes-induced alterations in latissimus dorsi muscle properties impair effectiveness of dynamic cardiomyoplasty in rats.

    abstract::Short-term diabetes was induced in male Wistar rats with streptozotocin injection. The effects of diabetes on latissimus dorsi (LD) muscle contractile and biochemical properties and acute cardiomyoplasty (CDM) were assessed and compared with data from 16 control rats. Isometric force, contractile properties, and fatig...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47349.x

    authors: De Angelis K,Senna S,Irigoyen MC,Cestari IA

    更新日期:2004-04-01 00:00:00

  • Clinical validation of a predictive modeling equation for sodium.

    abstract::Changes in plasma sodium (Na) concentration during hemodialysis were predicted by changes in Na concentration of the dialysate at equilibrium with the plasma, according to the formula C't = CD - (CD - C'0) [(V0 - QFt)/V0]A/QF, where C'0 and C't are the Na concentration of the dialysate at equilibrium with the plasma a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04365.x

    authors: Man NK,Petitclerc T,Tien NQ,Jehenne G,Funck-Brentano JL

    更新日期:1985-05-01 00:00:00

  • Pretreatment With Inactivated Bacillus Calmette-Guerin Increases CD4+CD25+ Regulatory T Cell Function and Decreases Functional and Structural Effects of Asthma Induction in a Rat Asthma Model.

    abstract::Bacillus Calmette-Guerin (BCG) has been shown to have therapeutic effects on asthma through CD4+CD25+ regulatory T cells (Tregs). We sought to assess pretreatment with inactivated BCG on CD4+CD25+ Tregs and its functional and structural effects in rat asthma model. The rat asthma model was established using ovalbumin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12566

    authors: Gong P,Li Y,Tan YP,Li H

    更新日期:2016-04-01 00:00:00

  • Double filtration plasmapheresis for the treatment of rheumatoid arthritis: a study of 21 cases.

    abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00344.x

    authors: Liu JD,Zhang C,Li WS,Lun LD

    更新日期:1997-02-01 00:00:00

  • Extracorporeal Life Support in Out-of-Hospital Refractory Cardiac Arrest.

    abstract::Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present dur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12655

    authors: Rousse N,Robin E,Juthier F,Hysi I,Banfi C,Al Ibrahim M,Coadou H,Goldstein P,Wiel E,Vincentelli A

    更新日期:2016-09-01 00:00:00

  • Transcutaneous monitoring of blood gas tensions in patients on intermittent peritoneal dialysis.

    abstract::A relative contraindication to intermittent peritoneal dialysis (IPD) is chronic lung disease. To evaluate whether the instillation of 2 L of fluid into the peritoneal cavity affects respiratory function, five IPD patients were studied in the supine position during the first 4 h of a routine IPD session. Blood gas ten...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02768.x

    authors: Korzets Z,Pomeranz A,Shachor Y,Bernheim J

    更新日期:1988-06-01 00:00:00

  • Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers.

    abstract::Doppler ultrasound is a noninvasive technique for monitoring moving objects such as flowing blood while ignoring stationary objects such as shunt tubing. A Doppler system was investigated to determine its sensitivity in detecting particulate release in blood during hemodialysis. Seven hemodialysis procedures with dogs...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04275.x

    authors: Badylak SF,Ash SR,Thornhill JA,Carr DJ

    更新日期:1984-05-01 00:00:00

  • High cell-density culture system of hepatocytes entrapped in a three-dimensional hollow fiber module with collagen gel.

    abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02310.x

    authors: Takeshita K,Ishibashi H,Suzuki M,Yamamoto T,Akaike T,Kodama M

    更新日期:1995-02-01 00:00:00

  • Acquired Von Willebrand Syndrome and Blood Pump Design.

    abstract::The existence of acquired von Willebrand syndrome (AVWS) in patients with continuous flow left ventricular assist devices (LVADs) is well documented and has been verified by numerous investigators. AVWS has not been observed to occur in pulsatile devices such as the SynCardia total artificial heart (TAH), the HeartMat...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.13291

    authors: Rosenberg G,Siedlecki CA,Jhun CS,Weiss WJ,Manning K,Deutsch S,Pierce W

    更新日期:2018-12-01 00:00:00

  • Modified DALI LDL-apheresis using trisodium citrate anticoagulation plus bicarbonate or lactate-buffered hemofiltration substitution fluids as primers.

    abstract:BACKGROUND:DALI (direct adsorption of lipids) is the first LDL-apheresis technique able to adsorb low-density lipoprotein (LDL) and lipoproteina) directly from whole blood. In the standard procedure, acid citrate dextrose (ACD-A) is used as anticoagulation and the adsorber is rinsed with a specially manufactured primin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2003.07104.x

    authors: Bosch T,Wendler T,Maschke H

    更新日期:2003-06-01 00:00:00

  • A nonsurgical technique for blood access in extracorporeal affinity adsorption of antibodies in rats.

    abstract::Monoclonal antibodies for targeting cytotoxic conjugates to tumor cells are currently being evaluated together with extracorporeal affinity adsorption. The aim of the adsorption was to reduce undesired side effects in normal organs and to increase the tumor-to-normal tissue ratios. This technique is also applicable to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00380.x

    authors: Mårtensson L,Nilsson R,Sjögren HO,Strand SE,Tennvall J

    更新日期:2007-04-01 00:00:00

  • Magnevad status of design improvements human blood results and preliminary sheep trial.

    abstract::Magnevad II is an improved version of Magnevad I and both are fourth-generation axial flow left ventricular assist devices. A major simplification has been implemented and tested. Magnevad I used a magnetically suspended rotor requiring active axial control. Magnevad II is completely passive but otherwise similar. A s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29113.x

    authors: Goldowsky M,Lafaro R,Reed G

    更新日期:2005-10-01 00:00:00

  • Demand for and use of functional electrical stimulation systems and conventional orthoses in the spinal lesioned community of the UK.

    abstract::The use of and demand for functional electrical stimulation (FES) systems and conventional orthoses in the spinal cord lesioned population was assessed. The assessment was conducted by a postal survey of the members of the spinal injury associations in the U.K. Out of all the respondents, only 2% had used an FES syste...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06361.x

    authors: Maxwell DJ,Granat MH,Baardman G,Hermens HJ

    更新日期:1999-05-01 00:00:00

  • Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

    abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06594.x

    authors: Mesana T,Collart F,Caus T,Pomane C,Graziani N,Bruder N,Dufour H,Grisoli F,Montiès JR

    更新日期:2000-06-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Lipid apheresis: from a heroic treatment to routine clinical practice.

    abstract::Lipid apheresis has developed from a heroic treatment into a routine clinical therapy and currently is the major indication for performing extracorporeal plasma therapy. Whereas it was once reserved for patients with homozygous familial hypercholesterolemia, today it has a place in the secondary prevention of severe c...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04525.x

    authors: Bosch T

    更新日期:1996-05-01 00:00:00

  • Is the dog a useful model for accelerated calcification study of cardiovascular bioprostheses?

    abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00735.x

    authors: Chanda J,Kuribayashi R,Abe T,Sekine S,Shibata Y,Yamagishi I

    更新日期:1997-05-01 00:00:00

  • The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

    abstract::Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged con...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00022.x

    authors: Mizuno T,Nishinaka T,Ohnishi H,Tatsumi E,Tsukiya T,Oshikawa M,Shioya K,Takewa Y,Homma A,Takano H,Kitamura S,Taenaka Y

    更新日期:2003-10-01 00:00:00

  • Further development of hybrid functional electrical stimulation orthoses.

    abstract::In this study two aspects of hybrid functional electrical stimulation (FES) orthoses were investigated: joint motion constraints and FES control strategies. First, the effects of joint motion constraints on the gait of normal subjects were investigated using modern motion analysis systems, including electromyogram (EM...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb04648.x

    authors: Yang L,Granat MH,Paul JP,Condie DN,Rowley DI

    更新日期:1997-03-01 00:00:00

  • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

    abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06414.x

    authors: Wada H,Fukunaga S,Watari M,Sakai H,Sugawara Y,Ochikubo H,Imai K,Shibamura H,Orihashi K,Sueda T,Matsuura Y

    更新日期:1999-08-01 00:00:00

  • A new smartphone-based method for wound area measurement.

    abstract::Proper wound healing can be assessed by monitoring the wound surface area. Its reduction by 10 or 50% should be achieved after 1 or 4 weeks, respectively, from the start of the applied therapy. There are various methods of wound area measurement, which differ in terms of the cost of the devices and their accuracy. Thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12169

    authors: Foltynski P,Ladyzynski P,Wojcicki JM

    更新日期:2014-04-01 00:00:00

  • Dialysis reduces portal pressure in patients with chronic hepatitis C.

    abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00925.x

    authors: Khurana S,Simcox T,Twaddell W,Drachenberg C,Flasar M

    更新日期:2010-07-01 00:00:00

  • Hemolysis test of disposable type vibrating flow pump.

    abstract::The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03724.x

    authors: Kobayashi S,Nitta S,Yambe T,Sonobe T,Naganuma S,Hashimoto H

    更新日期:1997-07-01 00:00:00

  • Estimation of phosphene spatial variability for visual prosthesis applications.

    abstract::Visual prostheses are the focus of intensive research efforts to restore some measure of useful vision to blind or near-blind patients. The development of such technology is being guided to an extent by tools that simulate prosthesis behavior for healthy sighted subjects in order to assess system requirements and conf...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00878.x

    authors: Obeid I,Veraart C,Delbeke J

    更新日期:2010-05-01 00:00:00

  • Significance of percutaneous cardiopulmonary bypass support for volume reduction surgery with severe hypercapnia.

    abstract::In patients with reduced respiratory function, lung resection is associated with high risk because separate ventilation is generally needed for safe management. For patients with end-stage emphysema, intraoperative respiratory management is important and particularly difficult because neither incomplete oxygenation no...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06339.x

    authors: Tsunezuka Y,Sato H,Tsubota M,Seki M

    更新日期:2000-01-01 00:00:00

  • Development of a novel centrifugal pump: magnetic rotary pump.

    abstract::The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03734.x

    authors: Naganuma S,Yambe T,Sonobe T,Kobayashi S,Nitta S

    更新日期:1997-07-01 00:00:00

  • Heart valve inspired and multi-stream aortic cannula: Novel designs for cardiopulmonary bypass improvement in neonates.

    abstract::In a typical open-heart surgery, the blood flow through the aortic cannula is a critical element of the cardiopulmonary bypass (CPB) procedure. Especially for the neonatal and pediatric CPB flow conditions, the need for small hydraulic diameter and large blood flow results confined turbulent jet flow regimes that exac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13462

    authors: Rasooli R,Pekkan K

    更新日期:2019-10-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00