Extracorporeal Life Support in Out-of-Hospital Refractory Cardiac Arrest.

Abstract:

:Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present during cardiopulmonary resuscitation (CPR), or if cardiac arrest was secondary to intoxication or hypothermia (≤32°C). Otherwise, patients would receive ECLS if (i) no-flow duration was less than 5 min; (ii) time delays from CPR to ECLS start (low flow) were less than 100 min; and (iii) expiratory end tidal CO2 (ETCO2 ) was more than 10 mm Hg 20 min after initiating CPR. We have reported here our experience with ECLS in OHrCA according to the previous guidelines. We retrospectively analyzed mortality rates of patients supported with ECLS in case of OHrCA. From December 2009 to December 2013, 183 patients were assisted with ECLS, among which 32 cases were of OHrCA. Mean age for the OHrCA patients was 43.6 years. Over two-thirds were male (71.9%). Causes of OHrCA included intoxication, isolated hypothermia <32°C, acute coronary syndrome, pulmonary edema, and other cardiac pathology. Despite adherence to protocols, only two patients (6.2%) with hypothermia and acute myocardium ischemia, respectively, could be discharged from hospital after cardiac recovery. Causes of death were brain death and multiple organ failure. Despite ECLS support setting in accordance with French guidelines in case of refractory OHrCA, mortality rates remained high. French ECLS support recommendations for OHrCA due to presumed cardiac cause should be re-examined through new studies. Low flow duration should be improved by a shorter time of CPR before hospital transfer.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Rousse N,Robin E,Juthier F,Hysi I,Banfi C,Al Ibrahim M,Coadou H,Goldstein P,Wiel E,Vincentelli A

doi

10.1111/aor.12655

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

904-9

issue

9

eissn

0160-564X

issn

1525-1594

journal_volume

40

pub_type

杂志文章
  • Anticoagulation with fondaparinux for hemodiafiltration in patients with heparin-induced thrombocytopenia: dose-finding study and safety evaluation.

    abstract::The optimal anticoagulation regimen for hemodialysis (HD) in patients with heparin-induced thrombocytopenia (HIT) has not been defined. Hemodiafiltration (HDF) adds a large convective component to HD, thereby changing the pharmacokinetics of most anticoagulants. Data on coagulation regimens for HDF are scant. We there...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12002

    authors: Mahieu E,Claes K,Jacquemin M,Evenepoel P,Op De Beek K,Bogaert AM,Kuypers D,Verhamme P,Meijers B

    更新日期:2013-05-01 00:00:00

  • The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers.

    abstract::Recently, the use of electrolyzed solutions has attracted considerable interest in Japan. This study investigates the efficiency of electrolyzed solutions as disinfecting agents (DA) in the reuse of dialyzers and compares their efficiency to that of other disinfectants currently in use. The following 3 methods were em...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06611.x

    authors: Tanaka N,Tanaka N,Fujisawa T,Daimon T,Fujiwara K,Yamamoto M,Abe T

    更新日期:2000-12-01 00:00:00

  • Opening-wedge high tibial osteotomy with and without bone graft.

    abstract::Medial opening-wedge has gained popularity in comparison to other techniques of high tibial osteotomy. This technique involves the creation of a gap in the tibia. Filling the gap with autologous iliac bone graft was recommended in the classic description, to prevent complications such as correction loss or delayed bon...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2010.01058.x

    authors: Zorzi AR,da Silva HG,Muszkat C,Marques LC,Cliquet A Jr,de Miranda JB

    更新日期:2011-03-01 00:00:00

  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • Kinetics of group IB and IIA phospholipase A2 during low-volume continuous hemodiafiltration in severe acute pancreatitis.

    abstract::Continuous hemodiafiltration (CHDF) has been performed for the treatment of severe acute pancreatitis. Phospholipase A2 (PLA2) is one of the important mediators which exacerbate acute pancreatitis, but whether PLA2 can be removed by CHDF is unclear. In this study, the kinetics of group IB and group IIA PLA2 was examin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2007.00398.x

    authors: Suzuki M,Okahisa T,Sogabe M,Iwaki H,Okita Y,Ohnishi Y,Ito S

    更新日期:2007-05-01 00:00:00

  • Heart Transplant Waiting List Implications of Increased Ventricular Assist Device Use as a Bridge Strategy: A National Analysis.

    abstract:BACKGROUND:The use of ventricular assist devices (VAD) as a bridge to heart transplant (HT) is increasing, while HT volume remains stagnant. This may portend longer waiting times and an otherwise more competitive environment for all patients on the HT waiting list. METHODS:A retrospective analysis of patients who were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13833

    authors: Han JJ,Elzayn H,Duda MM,Iyengar A,Acker AM,Patrick WL,Helmers M,Birati EY,Atluri P

    更新日期:2020-10-01 00:00:00

  • Flow through an outlet cannula of a rotary ventricular assist device.

    abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06931_4.x

    authors: Manning KB,Miller GE

    更新日期:2002-08-01 00:00:00

  • Potential mechanisms for muscle-powered cardiac support.

    abstract::Biomechanical actuation of an implanted ventricular assist device (VAD) is an attractive means of providing long-term circulatory support. Studies show that energy from electrically stimulated skeletal muscle can, in principle, be used to provide tether-free cardiac assistance without the need for percutaneous driveli...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01170.x

    authors: Trumble DR

    更新日期:2011-07-01 00:00:00

  • Physical testing of elastomers for cardiovascular applications.

    abstract::There are presently no short-term in vitro fatigue tests available that can predict long-term in vivo performance of elastomers in physiological environments. Thus, the introduction of new and better elastomers for cardiovascular applications is hampered in the development stage by lack of data about which materials s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04162.x

    authors: McMillin CR

    更新日期:1983-02-01 00:00:00

  • In Vitro Assessment of Electric Currents Increasing the Effectiveness of Vancomycin Against Staphylococcus epidermidis Biofilms.

    abstract::Biofilms are communities of bacteria that can cause infections which are resistant to the immune system and antimicrobial treatments, posing a significant threat for patients with implantable and indwelling medical devices. The purpose of our research was to determine if utilizing specific parameters for electric curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12678

    authors: Haddad PA,Mah TF,Mussivand T

    更新日期:2016-08-01 00:00:00

  • Stent treatment of inferior vena cava compression in an ovine with a total artificial heart.

    abstract::Although current continuous-flow total artificial hearts (CFTAHs) are much smaller than previous models, venous kinking may still occur after device implantation, especially in smaller animals. By inserting a self-expanding stent at the site of venous narrowing in a sheep model implanted with a CFTAH, we were able to ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01233.x

    authors: Tuzun E,Parnis S,Rios J,Winkler JA,Cohn WE

    更新日期:2011-07-01 00:00:00

  • Judicious usage of estrogen/progesterone for angiodysplasia.

    abstract::We recently experienced a case of a female hemodialysis patient with multiple intestinal angiodysplasias. In 2001, she complained of melena, and angiographic embolization halted bleeding from ileum angiodysplasia. In 2002, she again complained of black stool. Abdominal angiography found jejunum angiodysplasia, and pha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29003.x

    authors: Takenaka T,Kanno Y,Suzuki H

    更新日期:2005-01-01 00:00:00

  • Experimental study on shear stress distributions in a centrifugal blood pump.

    abstract::Wall shear stress on the pump casing cover was measured using a surface-mounted hot-film sensor. In addition, the shear stress distribution in the pump was qualitatively investigated by means of oil-film visualization. The characteristics of shear stress in the pump are discussed, including the results on the oil-film...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00421.x

    authors: Mizunuma H,Nakajima R

    更新日期:2007-07-01 00:00:00

  • Survival of patients on chronic hemodialysis: single center experience.

    abstract::Patient survival from our hemodialysis (HD) center over the past 11 years was analyzed. Four hundred four patients, 212 female and 192 male, were treated by chronic intermittent HD. Patients were offered standard acetate-cellulosic membranes of 1.0-1.3 m2. During this period 181 patients died. One hundred three patien...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06291.x

    authors: Polenakovik M,Sikole A,Stojcev N,Spasovski G,Amitov V,Nikolov V,Masin G,Klinkmann H

    更新日期:1999-01-01 00:00:00

  • Renal effects of multiple infusion of pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) solution in dogs.

    abstract::Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP), which is made from out-dated human red blood cells by two major chemical modifications, namely pyridoxalation and conjugation with polyoxyethylene (POE), is currently under development as a physiological oxygen carrier. This study assessed the effects of PHP-88...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00424.x

    authors: Takahashi T,Iwasaki K,Malchesky PS,Harasaki H,Matsushita M,Nosé Y,Rolin H 3rd,Hall PM

    更新日期:1993-03-01 00:00:00

  • A novel, valveless ventricular assist device: the FishTail pump. First experimental in vivo studies.

    abstract::This article presents the first in vivo experiments with a new type of valveless ventricular assist device, a wave-generating pump. Our goal was to evaluate the hemodynamic performance of the pump by comparing it with the Biomedicus BP-80 centrifugal pump and by sustaining a 3 h long left ventricular assistance. We co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06973.x

    authors: Feier H,Mekkaoui C,Drevet JB,Sérée Y,Richomme C,Rolland PH,Mesana TG

    更新日期:2002-12-01 00:00:00

  • Peritoneal dialysis solutions for the 21st century.

    abstract::Existing peritoneal dialysis (PD) solutions were formulated for the maintenance of fluid and electrolyte balance, correction of metabolic acidosis, and the removal of metabolic waste products. Solutions currently in development are designed to improve biocompatibility by neutralizing pH and reducing glucose degradatio...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06022.x

    authors: Martis L,Chen C,Moberly JB

    更新日期:1998-01-01 00:00:00

  • Biodegradation and biocompatibility of polyorganophosphazene.

    abstract::We investigated biodegradation and biocompatibility of poly(organophosphazenes). We prepared poly(organophosphazenes) having different side chain groups. The blood compatibility of poly(organophosphazenes) containing fluorinated side groups, poly(bis[trifluoroethoxy]phosphazene) (PbFP) and poly([trifluoroethoxy][ethyl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07029.x

    authors: Kawakami H,Kanezaki S,Sudo M,Kanno M,Nagaoka S,Kubota S

    更新日期:2002-10-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • Intensive Home Hemodialysis: An Eye at the Past Looking for the Hemodialysis of the Future.

    abstract::Multiple observational studies along with a limited number of randomized clinical trials suggest that intensive hemodialysis (IHD) not only improves outcomes for uremic patients undergoing chronic dialysis but does so with a more favorable cost/benefit ratio compared with conventional hemodialysis. As a result of this...

    journal_title:Artificial organs

    pub_type: 历史文章,杂志文章,评审

    doi:10.1111/aor.12458

    authors: Naso A,Scaparrotta G,Naso E,Calò LA

    更新日期:2015-09-01 00:00:00

  • Hemolysis Related to Turbulent Eddy Size Distributions Using Comparisons of Experiments to Computations.

    abstract::Turbulent blood flow in medical devices contributes to blood trauma, yet the exact mechanism(s) have not been fully elucidated. Local turbulent stresses, viscous stresses, and the rate of dissipation of the turbulent kinetic energy have been proffered as hypotheses to describe and predict blood damage. In this work, s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12572

    authors: Ozturk M,O'Rear EA,Papavassiliou DV

    更新日期:2015-12-01 00:00:00

  • Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump.

    abstract::A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male piv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.6184r.x

    authors: Takami Y,Yamane S,Makinouchi K,Niimi Y,Sueoka A,Nosé Y

    更新日期:1998-09-01 00:00:00

  • Adsorption of microorganism components by lixelle beads.

    abstract::We reported previously that Lixelle, which was used for beta-2 microglobulin (BMG) adsorption columns, could adsorb not only BMG but also inflammatory cytokines. We then were interested in the application of Lixelle to patients with systemic inflammatory response syndrome (SIRS) and tried to find out its ability to ad...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06502-2.x

    authors: Tsuchida K,Takemoto Y,Nakatani T,Nakamura T,Sugimura K,Yamamoto K

    更新日期:2000-07-01 00:00:00

  • Implantation of the total artificial heart by lateral thoracotomy.

    abstract::Progress in the techniques for surgical implantation of the artificial heart has progressed in parallel with the technology and design of the prosthesis. In the author's first experience with total artificial heart (TAH) implantation (1968) a trans-sternal split was used opening the sixth intercostal space on the righ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1977.tb00984.x

    authors: Olsen DB,Fukumasu H,Kolff J,Nakagaki M,Finch LR,Kolff WJ

    更新日期:1977-11-01 00:00:00

  • Cellulose acetate beads activate the complement system but inactivate the anaphylatoxins generated.

    abstract::The generation of anaphylatoxins, particularly C5a, is important in extracorporeal circulation therapies such as granulocyte/monocyte apheresis, which activates the complement system and elevates C5a levels. However, no side effects of granulocyte/monocyte apheresis using cellulose acetate beads have been reported. To...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00995.x

    authors: Takeda Y,Ohba M,Ueno M,Saniabadi AR,Wakabayashi I

    更新日期:2010-12-01 00:00:00

  • An implantable two channel drop foot stimulator: initial clinical results.

    abstract::This article reports preliminary results of pilot studies of a new implantable two channel drop foot stimulator. The stimulator consists of an externally worn transmitter inductively coupled to an implanted receiver unit located in the lower leg, lateral and distal to the knee. The receiver is connected to electrodes ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2002.06949.x

    authors: Kenney L,Bultstra G,Buschman R,Taylor P,Mann G,Hermens H,Holsheimer J,Nene A,Tenniglo M,van der Aa H,Hobby J

    更新日期:2002-03-01 00:00:00

  • Baroreflex sensitivity of an arterial wall during rotary blood pump assistance.

    abstract::It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex sy...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00864.x

    authors: Yambe T,Imachi K,Shiraishi Y,Yamaguchi T,Shibata M,Kameyama T,Yoshizawa M,Sugita N

    更新日期:2009-09-01 00:00:00

  • Re-endothelialization of non-detergent decellularized porcine vessels.

    abstract::Tissue engineering utilizes an interdisciplinary approach to generate constructs for the treatment and repair of diseased organs. Generation of small vessels as vascular grafts or as envisioned central vessel for vascularized constructs is still a challenge. Here, the decellularization of porcine vessels by a non-dete...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13836

    authors: Eyre K,Samper E,Haverich A,Hilfiker A,Andrée B

    更新日期:2020-10-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00