Demand for and use of functional electrical stimulation systems and conventional orthoses in the spinal lesioned community of the UK.

Abstract:

:The use of and demand for functional electrical stimulation (FES) systems and conventional orthoses in the spinal cord lesioned population was assessed. The assessment was conducted by a postal survey of the members of the spinal injury associations in the U.K. Out of all the respondents, only 2% had used an FES system for walking. In comparison, 13% had used some kind of orthosis. Of the small numbers who had used an FES system for walking, more than half had no functional walking abilities. The majority of orthosis users had some independent walking ability. The demand for walking improvements was high among the respondents although this was not matched by the demand for improved orthotic solutions. In conclusion, it would appear that there is a need for simple FES systems offering walking improvement to the incomplete spinal cord lesioned (SCI) subject.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Maxwell DJ,Granat MH,Baardman G,Hermens HJ

doi

10.1046/j.1525-1594.1999.06361.x

subject

Has Abstract

pub_date

1999-05-01 00:00:00

pages

410-2

issue

5

eissn

0160-564X

issn

1525-1594

journal_volume

23

pub_type

杂志文章
  • Paper is a compatible bed for rat hepatocytes.

    abstract::To develop an effective hybrid bioartificial liver (BAL) device, the material of the scaffold is very important to support hepatocytes that have both growth ability and hepatic differentiated functions. In this study we used paper (Kimwipe, Kimberly-Clark Corp., Roswell, GA, U.S.A.) as a scaffold. Primary hepatocytes ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06506.x

    authors: Mizuguchi T,Mitaka T,Sato F,Mochizuki Y,Hirata K

    更新日期:2000-04-01 00:00:00

  • Minimally invasive access for central extracorporeal life support: how we do it.

    abstract::Central extracorporeal life support (ECLS) is an effective treatment method of cardiogenic shock patients with or without lung failure. However, complications like infection and bleeding are common. The classical implantation approach requires full sternotomy, mobilization of the heart, with the well-known risks of bl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12344

    authors: Weymann A,Sabashnikov A,Patil NP,Mohite PN,Zych B,Garcia Saez D,Popov AF,Simon AR

    更新日期:2015-02-01 00:00:00

  • Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12359

    authors: Assmann A,Gül F,Benim AC,Joos F,Akhyari P,Lichtenberg A

    更新日期:2015-03-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.

    abstract::The therapy of terminal heart failure with left ventricular assist devices has become a standard in cardiac surgery. Yet the surgical implantation technique is not standardized and differs from center to center. Complications associated with left ventricular assist device (LVAD) inflow cannula placement are thrombosis...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12735

    authors: Hanke JS,Krabatsch T,Rojas SV,Deniz E,Ismail I,Martens A,Shrestha M,Haverich A,Netuka I,Schmitto JD

    更新日期:2017-03-01 00:00:00

  • Beta-2-microglobulin and main granulocyte components in hemodialysis patients.

    abstract::Plasma levels of granulocyte elastase in complex with alpha 1-proteinase inhibitor (E-alpha 1-PI) increased during hemodialysis from 110 +/- 10 to 506 +/- 66 micrograms/L using dialyzers made of polyamide, from 95 +/- 2.2 to 211 +/- 54 micrograms/ml with hemophane and from 114 +/- 10 to 203 +/- 25 using dialyzers made...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02842.x

    authors: Haag-Weber M,Schollmeyer P,Hörl WH

    更新日期:1989-04-01 00:00:00

  • Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.

    abstract::The weight gain of IVOX devices removed from the first 49 human clinical trials patients after from 1 to 29 days of implantation into the venae caval blood stream has been assessed. Each patient had received sufficient systemic heparin to maintain activated clotting times between 150 and 200 s while the IVOX device wa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03329.x

    authors: Imai H,Schaap RN,Mortensen JD

    更新日期:1994-11-01 00:00:00

  • A new technique to increase coronary flow. Preliminary report.

    abstract::This study was planned to investigate whether part of the energy produced by cardiac contraction to propel blood toward the systemic circulation can be used to increase the coronary flow in systole. Ten devices (I-X) designed to divert laterally part of a flow column (without substantially increasing resistance to flo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01080.x

    authors: Moulopoulos S,Stamatelopoulos S,Boufas D,Yannopoulos C,Marousis G,Kouvaras G

    更新日期:1979-11-01 00:00:00

  • A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller.

    abstract::A magnetically levitated (maglev) centrifugal blood pump (CBP), intended for use as a ventricular assist device, needs to be highly durable and reliable for long-term use without any mechanical failure. Furthermore, maglev CBPs should be small enough to be implanted into patients of various size and weight. We have de...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00202.x

    authors: Asama J,Shinshi T,Hoshi H,Takatani S,Shimokohbe A

    更新日期:2006-03-01 00:00:00

  • Dialysate and blood temperature during hemodialysis: comparing isothermic dialysis with a single-pass batch system.

    abstract::The Genius is a convenient single-pass batch hemodialysis system. Dialysate is heated during the preparation phase. Once the container is filled at one of the three available starting temperatures, dialysate cools spontaneously. As dialysate temperature plays an important role in hemodynamic stability, knowledge of th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00981.x

    authors: Dhondt A,Eloot S,Verbeke F,Vanholder R

    更新日期:2010-12-01 00:00:00

  • Superior mesenteric artery mycotic aneurysm in patients with left ventricular assist device support and intravenous drug abuse.

    abstract::Mycotic aneurysm of the superior mesenteric artery (SMA) is one of the complications associated with infective endocarditis. However, there are no previous case reports in the literature describing mycotic SMA aneurysm after left ventricular assist device (LVAD) implantation. We describe the case of a 31-year-old male...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01250.x

    authors: Motomura T,Bruckner B,Leon-Becerril J,Anaya-Ayala JE,de Rienzo-Madero B,Bismuth J,Bunge R,Irwin S,Loebe M

    更新日期:2011-07-01 00:00:00

  • Effect of hemodialysis on T lymphocyte subsets, con-A-activated suppressor cell activity, and interleukin-2 receptor expression on lymphocytes in chronic uremic patients.

    abstract::Effect of hemodialysis (HD) on some indices of immune response was studied in nine chronic uremics. Total lymphocyte, OKT4+, and OKT8+ cell numbers significantly decreased during the first 20 min of HD, and they were decreased till the third hour of the procedure, whereas the OKT4+/OKT8+ cell number ratio did not chan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02861.x

    authors: Tchórzewski H,Luciak M,Trznadel K,Majewska E,Pokoca L

    更新日期:1989-06-01 00:00:00

  • Regenerative medicine for cardiovascular disorders-new milestones: adult stem cells.

    abstract::Cardiovascular disorders are the leading causes of mortality and morbidity in the developed world. Cell-based modalities have received considerable scientific attention over the last decade for their potential use in this clinical arena. This review was intended as a brief overview on the subject of therapeutic potent...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2006.00209.x

    authors: Akar AR,Durdu S,Corapcioglu T,Ozyurda U

    更新日期:2006-04-01 00:00:00

  • A newly designed adapter for testing an ex vivo mitral valve apparatus.

    abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06293.x

    authors: Katoh T,Ikeda N,Nishi K,Gohra H,Hamano K,Noda H,Fujimura Y,Esato K

    更新日期:1999-10-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Experiencing Functional Electrical Stimulation Roots on Education, and Clinical Developments in Paraplegia and Tetraplegia With Technological Innovation.

    abstract::Cybernetics-based concepts can allow for complete independence for paralyzed individuals, including sensory motor recovery. Spinal cord injuries are responsible for a huge stress on health and a financial burden to society. This article focuses on novel procedures such as functional diagnosis for paraplegics and tetra...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12620

    authors: Varoto R,Cliquet A Jr

    更新日期:2015-10-01 00:00:00

  • Double-blind evaluation of plasmapheresis in schizophrenic patients: a pilot study.

    abstract::Interest in the effects and possible mechanisms of hemodialysis on schizophrenic patients has led to a double-blind evaluation of the effects of plasmapheresis on symptoms of schizophrenia. Also, plasmapheresis was felt to be an invaluable tool for investigating the autoimmune theory of schizophrenia. Patients (n = 10...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1983.tb04203.x

    authors: Schulz SC,van Kammen DP,Waters R,Klein HG,Balow JE,Bunney WE Jr

    更新日期:1983-08-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Numerical estimation of hemolysis from the point of view of signal and system.

    abstract::The power-law based models for predicting shear-induced hemolysis are widely used in the optimization design of blood-contacting devices. However, this category of models has fallen short of accuracy when compared with the results of the in vitro experiments. The aim of this study is to develop an alternative model fr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12294

    authors: Li H,Ruan X,Qian W,Fu X

    更新日期:2014-12-01 00:00:00

  • Combining novel biomolecules and stimuli-sensitive biomaterials into new recognition-response biomaterial systems.

    abstract::An important present and emerging trend in biomaterials development is the synthesis of polymers which combine capabilities of biologic recognition ("biomimetic") with sensitivity to small environmental changes ("stimuli-responsive"). This short article highlights some of the many opportunities and challenges in this ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02813.x

    authors: Hoffman AS

    更新日期:1988-12-01 00:00:00

  • Development of a novel centrifugal pump: magnetic rotary pump.

    abstract::The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03734.x

    authors: Naganuma S,Yambe T,Sonobe T,Kobayashi S,Nitta S

    更新日期:1997-07-01 00:00:00

  • Cell exclusion in couette flow: evaluation through flow visualization and mechanical forces.

    abstract::Cell exclusion is the phenomenon whereby the hematocrit and viscosity of blood decrease in areas of high stress. While this is well known in naturally occurring Poiseuille flow in the human body, it has never previously been shown in Couette flow, which occurs in implantable devices including blood pumps. The high-she...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01561.x

    authors: Leslie LJ,Marshall LJ,Devitt A,Hilton A,Tansley GD

    更新日期:2013-03-01 00:00:00

  • Improved retention of endothelial cells seeded on polyurethane small-diameter vascular grafts modified by a recombinant RGD-containing protein.

    abstract::Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07141.x

    authors: Hsu SH,Sun SH,Chen DC

    更新日期:2003-12-01 00:00:00

  • Changes in Spirometry After Left Ventricular Assist Device Implantation.

    abstract::Left ventricular assist devices (LVADs) are increasingly being used as life-saving therapy in patients with end-stage heart failure. The changes in spirometry following LVAD implantation and subsequent unloading of the left ventricle and pulmonary circulation are unknown. In this study, we explored long-term changes i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12507

    authors: Mohamedali B,Bhat G,Yost G,Tatooles A

    更新日期:2015-12-01 00:00:00

  • Is vecuronium toxicity abolished by hemodialysis? A case report.

    abstract::Vecuronium is a curaric agent, largely used in anesthesia. Indications as to its employ in uremic patients appear to be debated because of partial renal elimination of the drug. A 52-year-old hemodialyzed woman required transplantectomy for rejection. At awakeness after general anesthesia (induced with fentanyl, propo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06496.x

    authors: Rollino C,Visetti E,Borsa S,Pignataro A,Pozzato M,Vallero A,Quarello F

    更新日期:2000-05-01 00:00:00

  • Oral treatment for jaundice using immobilized bilirubin oxidase.

    abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00527.x

    authors: Soltys PJ,Mullon C,Langer R

    更新日期:1992-08-01 00:00:00

  • Effects of pyridoxalated hemoglobin polyoxyethylene conjugate and other hemoglobin-related substances on arterial blood pressure in anesthetized and conscious rats.

    abstract::The effects of pyridoxalated hemoglobin polyoxyethylene conjugate (PHP) and other hemoglobin-related substances on arterial blood pressure (ABP) and heart rate (HR) were examined. Infusion of PHP and other hemoglobin-related substances elevated ABP and increased HR. The degree of the increase in ABP and HR did not dif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02300.x

    authors: Kida Y,Maeda M,Iwata S,Iwashita Y,Goto K,Nishi K

    更新日期:1995-02-01 00:00:00

  • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

    abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06414.x

    authors: Wada H,Fukunaga S,Watari M,Sakai H,Sugawara Y,Ochikubo H,Imai K,Shibamura H,Orihashi K,Sueda T,Matsuura Y

    更新日期:1999-08-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • Computational fluid dynamics and stent design.

    abstract::Stents are small, usually metallic tubes that are intended to prop open arteries blocked with atherosclerotic plaques. While stents have been used successfully in recent years, they still suffer from failure due to development of new tissue in stented segment (restenosis). Variations in the failure rates associated wi...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07084.x

    authors: Frank AO,Walsh PW,Moore JE Jr

    更新日期:2002-07-01 00:00:00