A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller.

Abstract:

:A magnetically levitated (maglev) centrifugal blood pump (CBP), intended for use as a ventricular assist device, needs to be highly durable and reliable for long-term use without any mechanical failure. Furthermore, maglev CBPs should be small enough to be implanted into patients of various size and weight. We have developed a compact maglev CBP employing a two-degree-of-freedom controlled magnetic bearing, with a magnetically suspended impeller directly driven by an internal brushless direct current (DC) motor. The magnetic bearing actively controls the radial motion of the impeller and passively supports axial and angular motions using a permanent magnet embedded in the impeller. The overall dimensions of the maglev CBP are 65 mm in diameter and 40 mm in height. The total power consumption and pump efficiency for pumping 6 L/min against a head pressure of 105 mm Hg were 6.5 W and 21%, respectively. To evaluate the characteristics of the maglev CBP when subjected to a disturbance, excitation of the base, simulating the movement of the patient in various directions, and the sudden interception of the outlet tube connected with the pump in a mock circulatory loop, simulating an unexpected kink and emergent clamp during a heart surgery, were tested by monitoring the five-degree-of-freedom motion of the impeller. Furthermore, the hemolytic characteristics of the maglev CBP were compared with those of the Medtronic Biomedicus BPX-80, which demonstrated the superiority of the maglev CBP.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Asama J,Shinshi T,Hoshi H,Takatani S,Shimokohbe A

doi

10.1111/j.1525-1594.2006.00202.x

subject

Has Abstract

pub_date

2006-03-01 00:00:00

pages

160-7

issue

3

eissn

0160-564X

issn

1525-1594

pii

AOR202

journal_volume

30

pub_type

杂志文章
  • Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves.

    abstract::Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceabili...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13503

    authors: Mao J,Rassoli A,Tong Y,Rouse EN,Le-Bel G,How D,Germain L,Fatouraee N,Zhang Z,Reed RR,Guidoin R

    更新日期:2019-10-01 00:00:00

  • Hemodynamic Evaluation of a Biological and Mechanical Aortic Valve Prosthesis Using Patient-Specific MRI-Based CFD.

    abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12955

    authors: Hellmeier F,Nordmeyer S,Yevtushenko P,Bruening J,Berger F,Kuehne T,Goubergrits L,Kelm M

    更新日期:2018-01-01 00:00:00

  • Hemodynamic evaluation of a new left ventricular assist device: an integrated cardioassist catheter as a pulsatile left ventricle-femoral artery bypass.

    abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00311.x

    authors: Ide H,Yamaguchi A,Ino T,Matsumoto H,Fujimasa I

    更新日期:1992-06-01 00:00:00

  • Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

    abstract::In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06228.x

    authors: Mueller XM,Tevaearai HT,Hayoz D,von Segesser LK

    更新日期:1999-02-01 00:00:00

  • Bone marrow combined with dental bud cells promotes tooth regeneration in miniature pig model.

    abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01064.x

    authors: Kuo TF,Lin HC,Yang KC,Lin FH,Chen MH,Wu CC,Chang HH

    更新日期:2011-02-01 00:00:00

  • Cell exclusion in couette flow: evaluation through flow visualization and mechanical forces.

    abstract::Cell exclusion is the phenomenon whereby the hematocrit and viscosity of blood decrease in areas of high stress. While this is well known in naturally occurring Poiseuille flow in the human body, it has never previously been shown in Couette flow, which occurs in implantable devices including blood pumps. The high-she...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01561.x

    authors: Leslie LJ,Marshall LJ,Devitt A,Hilton A,Tansley GD

    更新日期:2013-03-01 00:00:00

  • Adult polycystic kidney disease: who needs hospital follow-up?

    abstract::Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01441.x

    authors: Griveas I,Bishop K,World M

    更新日期:2012-07-01 00:00:00

  • Application of computational fluid dynamics techniques to blood pumps.

    abstract::Present-day computational fluid dynamics (CFD) techniques can be used to analyze the behavior of fluid flow in a variety of pumps. CFD can be a powerful tool during the design stage for rapid virtual prototyping of different designs, analyzing performance parameters, and making design improvements. Computational flow ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Sukumar R,Athavale MM,Makhijani VB,Przekwas AJ

    更新日期:1996-06-01 00:00:00

  • Antimicrobial Wound Dressing Containing Silver Sulfadiazine With High Biocompatibility: In Vitro Study.

    abstract::Many patients all over the world suffer from acute wounds caused by traumas or burns. In most crucial cases, skin regeneration cannot be promoted spontaneously, and skin grafts are applied as the main treatment. However, this therapy has some drawbacks which motivate researchers to develop wound dressings. In this stu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12682

    authors: Mohseni M,Shamloo A,Aghababaei Z,Vossoughi M,Moravvej H

    更新日期:2016-08-01 00:00:00

  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • Implantable volume monitor and miniaturized stimulator dedicated to bladder control.

    abstract::This paper describes a new miniaturized implantable bladder controller that is composed of 4 main parts: a volume monitoring device based on the tomography approach, a fully programmable miniaturized central processor and stimulator, a bidirectional data and power link, and an external controller. The proposed system ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Sawan M,Arabi K,Provost B

    更新日期:1997-03-01 00:00:00

  • Hemoperfusion and DNA synthesis in the rat liver. Part I: the effect of hemoperfusion on the rate of DNA synthesis.

    abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04080.x

    authors: Ryan CJ,Courtney JM,Wood CB,Blumgart LH

    更新日期:1982-05-01 00:00:00

  • Can the human lumbar posterior columns be stimulated by transcutaneous spinal cord stimulation? A modeling study.

    abstract::Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation, and movement. The human lumbar cord has become a target for modification of motor control by epidural and, more recently, by transcutaneous spinal cord stimulation. Posterior col...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01213.x

    authors: Danner SM,Hofstoetter US,Ladenbauer J,Rattay F,Minassian K

    更新日期:2011-03-01 00:00:00

  • Influence of different heparin concentrations on the results of in vitro investigations in plasmaseparation technology using capillary membrane filters.

    abstract::Capillary membrane filters are devices commonly used for plasmapheresis and recirculating detoxification systems, including plasmaseparation units. Besides clinical trials and case reports, research on plasmafiltration techniques is carried out using in vitro systems. Notably, such hemoperfused in vitro systems requir...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07132.x

    authors: Unger JK,Haltern C,Dohmen B,Rossaint R

    更新日期:2003-07-01 00:00:00

  • Numerical estimation of hemolysis from the point of view of signal and system.

    abstract::The power-law based models for predicting shear-induced hemolysis are widely used in the optimization design of blood-contacting devices. However, this category of models has fallen short of accuracy when compared with the results of the in vitro experiments. The aim of this study is to develop an alternative model fr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12294

    authors: Li H,Ruan X,Qian W,Fu X

    更新日期:2014-12-01 00:00:00

  • Differences in intravenous and subcutaneous application of recombinant human erythropoietin: a multicenter trial.

    abstract::The aims of this clinical study were to compare the maintenance doses for intravenous (i.v.) and subcutaneous (SC) administration of recombinant human erythropoietin (rhEPO) and to investigate whether there is any difference in the increase of the packed cellular volume (PCV) per week under i.v. and SC administration ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1994.tb03378.x

    authors: Schaller R,Sperschneider H,Thieler H,Dutz W,Hans S,Voigt D,Marx M,Engelmann J,Schöter KH,Scigalla P

    更新日期:1994-08-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • A Meta-Analysis of Renal Function After Adult Cardiac Surgery With Pulsatile Perfusion.

    abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.12452

    authors: Nam MJ,Lim CH,Kim HJ,Kim YH,Choi H,Son HS,Lim HJ,Sun K

    更新日期:2015-09-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Adverse events of subcutaneous recombinant human erythropoietin therapy: results of a controlled multicenter European study.

    abstract::In a controlled European multicenter study, clinical tolerance of subcutaneously administered recombinant human erythropoietin (rh-EPO) therapy and its influence on the course of illness in 362 hemodialyzed patients (162 males, 200 females) from 16 European dialysis centers was studied. Of these, 181 patients served a...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1993.tb00571.x

    authors: Klinkmann H,Wieczorek L,Scigalla P

    更新日期:1993-04-01 00:00:00

  • The impact of obesity on outcomes in patients receiving extracorporeal life support.

    abstract::Extracorporeal life support (ECLS) has been increasingly utilized to manage cardiac and pulmonary dysfunction. The impact of obesity on outcomes of ECLS is poorly defined. The purpose of the study was to compare in-hospital mortality, resource use, complications, and readmissions in obese versus non-obese patients rec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13752

    authors: Christian-Miller N,Hadaya J,Nakhla M,Sanaiha Y,Madrigal J,Emami S,Cale M,Sareh S,Benharash P

    更新日期:2020-11-01 00:00:00

  • Cooling device for bradycardia based on Peltier element for accurate anastomosis of off-pump coronary artery bypass grafting.

    abstract::Upon introducing off-pump coronary artery bypass grafting (CABG), the indications for CABG were expanded to include patients who previously had no operative indications. For accurate anastomosis, various devices and methods have been developed. Bradycardia is easily induced by drug administration. However, this method...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07087.x

    authors: Kuniyoshi Y,Koja K,Miyagi K,Shimoji M,Uezu T,Arakaki K,Yamashiro S,Mabuni K,Senaha S

    更新日期:2002-10-01 00:00:00

  • The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

    abstract::Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged con...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00022.x

    authors: Mizuno T,Nishinaka T,Ohnishi H,Tatsumi E,Tsukiya T,Oshikawa M,Shioya K,Takewa Y,Homma A,Takano H,Kitamura S,Taenaka Y

    更新日期:2003-10-01 00:00:00

  • Visual three-dimensional representation of beat-to-beat electrocardiogram traces during hemodiafiltration.

    abstract::This study evaluated the usefulness of the three-dimensional representation of electrocardiogram traces (3DECG) to reveal acute and gradual changes during a full session of hemodiafiltration (HDF) in end-stage renal disease (ESRD) patients. Fifteen ESRD patients were included (six men, nine women, age 46 ± 19 years ol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01382.x

    authors: Rodriguez-Fernandez R,Infante O,Perez-Grovas H,Hernandez E,Ruiz-Palacios P,Franco M,Lerma C

    更新日期:2012-06-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Modeling of a rotary blood pump.

    abstract::The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12142

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL

    更新日期:2014-03-01 00:00:00

  • Delivery of the bioactive gas hydrogen sulfide during cold preservation of rat liver: effects on hepatic function in an ex vivo model.

    abstract::The insults sustained by transplanted livers (hepatectomy, hypothermic preservation, and normothermic reperfusion) could compromise hepatic function. Hydrogen sulfide (H₂S) is a physiologic gaseous signaling molecule, like nitric oxide (NO) and carbon monoxide (CO). We examined the effect of diallyl disulfide as a H₂S...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01256.x

    authors: Balaban CL,Rodriguez JV,Guibert EE

    更新日期:2011-05-01 00:00:00

  • Ductular cholestasis, an unusual form of intrahepatic cholestasis, associated with cardiogenic shock and ventricular assist device.

    abstract::Ventricular assist devices have been shown to be effective in advanced heart failure selected patients. They often have borderline end-organ function, what facilitates organ dysfunction. Liver failure is difficult to manage and leads to increased morbidity and mortality. We report a case of ductular cholestasis, an un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00760.x

    authors: Mohedano-Gómez A,Pérez-Vela JL,Renes-Carreño E,De-Andrés CI,Corres-Peiretti MA,Arribas-López P,Gutierrez-Rodriguez J,Perales-Rodríguez-De-Viguri N

    更新日期:2010-02-01 00:00:00

  • Hemolysis test of a centrifugal pump in a pulsatile mode: the effect of pulse rate and RPM variance.

    abstract::Centrifugal pumps are generally employed as nonpulsatile blood flow pumps; however, these pumps can produce pulsatile flow by periodically alternating the impeller rotation speed. This study investigates blood trauma due to the effect of pulse frequency and various ranges of pump speed. The hemolysis tests were conduc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00489.x

    authors: Tayama E,Niimi Y,Takami Y,Ohashi Y,Ohtsuka G,Glueck JA,Mueller J,Nosé Y

    更新日期:1997-12-01 00:00:00