Cell exclusion in couette flow: evaluation through flow visualization and mechanical forces.

Abstract:

:Cell exclusion is the phenomenon whereby the hematocrit and viscosity of blood decrease in areas of high stress. While this is well known in naturally occurring Poiseuille flow in the human body, it has never previously been shown in Couette flow, which occurs in implantable devices including blood pumps. The high-shear stresses that occur in the gap between the boundaries in Couette flow are known to cause hemolysis in erythrocytes. We propose to mitigate this damage by initiating cell exclusion through the use of a spiral-groove bearing (SGB) that will provide escape routes by which the cells may separate themselves from the plasma and the high stresses in the gap. The force between two bearings (one being the SGB) in Couette flow was measured. Stained erythrocytes, along with silver spheres of similar diameter to erythrocytes, were visualized across a transparent SGB at various gap heights. A reduction in the force across the bearing for human blood, compared with fluids of comparable viscosity, was found. This indicates a reduction in the viscosity of the fluid across the bearing due to a lowered hematocrit because of cell exclusion. The corresponding images clearly show both cells and spheres being excluded from the gap by entering the grooves. This is the first time the phenomenon of cell exclusion has been shown in Couette flow. It not only furthers our understanding of how blood responds to different flows but could also lead to improvements in the future design of medical devices.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Leslie LJ,Marshall LJ,Devitt A,Hilton A,Tansley GD

doi

10.1111/j.1525-1594.2012.01561.x

subject

Has Abstract

pub_date

2013-03-01 00:00:00

pages

267-75

issue

3

eissn

0160-564X

issn

1525-1594

journal_volume

37

pub_type

杂志文章
  • Effect of cyclosporine therapy with low doses of corticosteroids on idiopathic nephrotic syndrome.

    abstract::Cyclosporine (CyA) has an immunosuppressive effect that might suggest a therapeutic role in idiopathic glomerular conditions. We focused on the optimization of CyA treatment control in patients with idiopathic nephrotic syndrome by using trough-level CyA measurements (C0) and the 2-h postdose levels (C2). Twenty-two p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00838.x

    authors: Griveas I,Visvardis G,Papadopoulou D,Nakopolou L,Karanikas E,Gogos K,Stavianoudakis G

    更新日期:2010-03-01 00:00:00

  • Technical feasibility of umbilical cannulation in midgestation lambs supported by the EXTra-uterine Environment for Neonatal Development (EXTEND).

    abstract::EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system for supporting extremely premature infants that replicates in utero conditions by maintaining a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit connected to the umbilical vessels. Target g...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13524

    authors: Hornick MA,Mejaddam AY,McGovern PE,Hwang G,Han J,Peranteau WH,Partridge EA,Davey MG,Flake AW

    更新日期:2019-12-01 00:00:00

  • Influence of middle molecules on the anemia of uremic patients.

    abstract::To evaluate their toxicity at the cellular level, middle molecules from uremic serum were incubated with erythrocytes from healthy subjects and the activity of the enzyme Delta-aminolevulinic acid dehydrase (D-ALA-D) and peroxidative hemolysis were investigated. Uremic middle molecules caused a significant decrease of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01626.x

    authors: Leber HW,Spiegelhalter R,Ulm A,Goubeaud G,Rawer P

    更新日期:1978-11-01 00:00:00

  • Biomechanical properties of decellularized porcine pulmonary valve conduits.

    abstract::Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00452.x

    authors: Seebacher G,Grasl C,Stoiber M,Rieder E,Kasimir MT,Dunkler D,Simon P,Weigel G,Schima H

    更新日期:2008-01-01 00:00:00

  • Dual-pump support in the inferior and superior vena cavae of a patient-specific fontan physiology.

    abstract::The implementation of simultaneous mechanical cavopulmonary assistance having blood pumps located in both of the vena cavae is investigated as an approach to treating patients with an ailing Fontan physiology. Identical intravascular blood pumps are employed to model the hemodynamic support of a patient-specific Fonta...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12039

    authors: Throckmorton AL,Lopez-Isaza S,Moskowitz W

    更新日期:2013-06-01 00:00:00

  • Electrotactile stimulator for artificial proprioception.

    abstract::With the goal of investigating artificial proprioception elicited by electrical stimulation, we have developed a tactile phi phenomenon-based stimulator. This two-channel microprocessed pulse amplitude modulation system generates two different envelope waveforms (triangular and elliptical) and allows programming and v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02318.x

    authors: Nohama P,Lopes AV,Cliquet Júnior A

    更新日期:1995-03-01 00:00:00

  • Treatment of severe hyperlipidemia: six years' experience with low-density lipoprotein apheresis.

    abstract::In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04455.x

    authors: Bambauer R,Schiel R,Latza R,Klinkmann J

    更新日期:1996-04-01 00:00:00

  • Is the dog a useful model for accelerated calcification study of cardiovascular bioprostheses?

    abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00735.x

    authors: Chanda J,Kuribayashi R,Abe T,Sekine S,Shibata Y,Yamagishi I

    更新日期:1997-05-01 00:00:00

  • Research into the development of a wearable bioartificial kidney with a continuous hemofilter and a bioartificial tubule device using tubular epithelial cells.

    abstract::Current hemodialysis treatment is insufficient because of intermittent treatment and loss of tubular function. In order to overcome the loss of tubular function, a bioartificial kidney has been developed consisting of continuous hemofiltration (CHF) with 10 L/day of filtrate and a bioartificial tubule device using pro...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2004.07323.x

    authors: Saito A

    更新日期:2004-01-01 00:00:00

  • Intestinal tissue oxygenation and tumor necrosis factor-alpha release during systemic blood flow changes in pigs with left ventricular assist devices.

    abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025001053.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-01-01 00:00:00

  • Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design.

    abstract::Planar particle image velocimetry was used to explore the flow behavior of the newly designed 12-cc Penn State pneumatic pediatric assist pump. Wall shear maps complemented the velocity data. Bjork-Shiley Monostrut 17-mm mechanical heart valves were used in the inlet and outlet ports. In comparison with larger Penn St...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00565.x

    authors: Manning KB,Wivholm BD,Yang N,Fontaine AA,Deutsch S

    更新日期:2008-06-01 00:00:00

  • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

    abstract::Since the introduction of high-performance prosthetic heart valves, particularly bileaflet valves and monoleaflet valves with larger opening angles, we have observed in vivo complex leaflet motion which has not been experimentally confirmed yet. We developed a computer-controlled hydraulic mock circulator to study the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00373.x

    authors: Ohta Y,Okamoto K,Sonderegger M,Dohi T,Matsumoto H,Horiuchi T

    更新日期:1997-04-01 00:00:00

  • HandS ECMO: Preliminary Experience With "Hub and Spoke" Model in Neonates With Meconium Aspiration Syndrome.

    abstract::We aim to evaluate clinical outcomes of emergent extracorporeal membrane oxygenation (ECMO) implantation in newborns with life-threatening meconium aspiration syndrome (MAS) in peripheral hospitals with Hub and Spoke (HandS) setting. We retrospectively reviewed all neonates presenting with MAS, with no other comorbidi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13270

    authors: Fichera D,Zanella F,Fabozzo A,Doglioni N,Trevisanuto D,Lolli E,Vida V,Ceccherini E,Ebraico A,Stellin G,Padalino M

    更新日期:2019-01-01 00:00:00

  • Characteristics of chronically paced cardiac functions in the congenital complete atrioventricular block.

    abstract::Characteristics of morphology, cardiac function, and cardiac reserve at late state were evaluated at rest, by changing the pacing rates, and after exercise in patients with ventricular pacemakers for isolated congenital complete atrioventricular block. Heart size was reduced statistically after pacemaker implantation,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02667.x

    authors: Nawa S,Kioka Y,Shimizu A,Tsuji H,Miyachi Y,Ebara K,Kino K,Shigenobu M,Murakami T,Senoo Y

    更新日期:1987-06-01 00:00:00

  • Plasma middle molecules in asymptomatic and "sick" uremic patients.

    abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Asaba H,Bergström J,Fürst P,Johnson C,Yahiel V

    更新日期:1981-01-01 00:00:00

  • Further development of hybrid functional electrical stimulation orthoses.

    abstract::In this study two aspects of hybrid functional electrical stimulation (FES) orthoses were investigated: joint motion constraints and FES control strategies. First, the effects of joint motion constraints on the gait of normal subjects were investigated using modern motion analysis systems, including electromyogram (EM...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb04648.x

    authors: Yang L,Granat MH,Paul JP,Condie DN,Rowley DI

    更新日期:1997-03-01 00:00:00

  • Is ionic dialysance a valid parameter for quantification of dialysis efficiency?

    abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06062.x

    authors: Mercadal L,Petitclerc T,Jaudon MC,Béné B,Goux N,Jacobs C

    更新日期:1998-12-01 00:00:00

  • Substantial early loss of induced pluripotent stem cells following transplantation in myocardial infarction.

    abstract::The limited success of cardiac stem cell therapy has lately generated discussion regarding its effectiveness. We hypothesized that immediate cell loss after intramyocardial injection significantly obscures the regenerative potential of stem cell therapy. Therefore, our aim was to assess the distribution and quantity o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12268

    authors: Martens A,Rojas SV,Baraki H,Rathert C,Schecker N,Zweigerdt R,Schwanke K,Rojas-Hernandez S,Martin U,Saito S,Schmitto JD,Haverich A,Kutschka I

    更新日期:2014-11-01 00:00:00

  • Performance of baffled bubble blood oxygenators.

    abstract::Bubble blood oxygenators equipped with baffles of various types in the oxygenating column were studied. The rate of hemolysis, the volumetric coefficient for oxygen absorption into blood, and the fractional gas holdup were found to be affected mainly by the superficial gas velocity. When compared with the conventional...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01032.x

    authors: Ohshima N,Yoshido F

    更新日期:1979-05-01 00:00:00

  • The Effect of Diode Laser With Different Parameters on Root Fracture During Irrigation Procedure.

    abstract::The aim of this study is to compare the effect of a single diode laser application and agitation of EDTA with diode laser with different parameters at different time intervals on root fracture. Ninety mandibular incisors were instrumented except the negative control group. The specimens were divided randomly into 10 g...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12608

    authors: Karataş E,Arslan H,Topçuoğlu HS,Yılmaz CB,Yeter KY,Ayrancı LB

    更新日期:2016-06-01 00:00:00

  • Percutaneous introduction of left atrial cannula for left heart bypass: utility of biplane transesophageal echocardiographic guidance for transseptal puncture.

    abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00537.x

    authors: Kyo S,Motoyama T,Miyamoto N,Noda H,Dohi Y,Omoto R

    更新日期:1992-08-01 00:00:00

  • In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.

    abstract::The therapy of terminal heart failure with left ventricular assist devices has become a standard in cardiac surgery. Yet the surgical implantation technique is not standardized and differs from center to center. Complications associated with left ventricular assist device (LVAD) inflow cannula placement are thrombosis...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12735

    authors: Hanke JS,Krabatsch T,Rojas SV,Deniz E,Ismail I,Martens A,Shrestha M,Haverich A,Netuka I,Schmitto JD

    更新日期:2017-03-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

    abstract::Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06426.x

    authors: Akimoto T,Yamazaki K,Litwak P,Litwak KN,Tagusari O,Mori T,Antaki JF,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:1999-08-01 00:00:00

  • Stent treatment of inferior vena cava compression in an ovine with a total artificial heart.

    abstract::Although current continuous-flow total artificial hearts (CFTAHs) are much smaller than previous models, venous kinking may still occur after device implantation, especially in smaller animals. By inserting a self-expanding stent at the site of venous narrowing in a sheep model implanted with a CFTAH, we were able to ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01233.x

    authors: Tuzun E,Parnis S,Rios J,Winkler JA,Cohn WE

    更新日期:2011-07-01 00:00:00

  • Experimental high-volume hemofiltration with predilutional tris-hydroxymethylaminomethane for correction of low tidal volume ventilation-induced acidosis.

    abstract::The most common method of controlling acidemia during lung-protective ventilation is CO₂ removal with an extracorporeal lung assist (ECLA) system. Another possibility to prevent acidemia is based on intravenous (i.v.) application of tris-hydroxymethyl-aminomethane (3 mol/L, THAM) buffer, which can bind hydrogen proton...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01204.x

    authors: Russ M,Deja M,Ott S,Bedarf J,Keckel T,Hiebl B,Wagner JJ,Unger JK

    更新日期:2011-06-01 00:00:00

  • Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

    abstract::Secondary flow in the centrifugal blood pump helps to enhance the washout effect and to minimize thrombus formation. On the other hand, it has an adverse effect on pump efficiency. Excessive secondary flow may induce hemolytic effects. Understanding the secondary flow is thus important to the design of a compact, effi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29012.x

    authors: Watanabe N,Masuda T,Iida T,Kataoka H,Fujimoto T,Takatani S

    更新日期:2005-01-01 00:00:00

  • Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

    abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02200.x

    authors: Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

    更新日期:1994-04-01 00:00:00

  • Myointimal hyperplasia: pathogenesis and implications. 1. In vitro characteristics.

    abstract::Myointimal hyperplasia (MIH) is an arterial wall smooth muscle cell (SMC) proliferative disorder. This process is responsible for a significant number of early and long-term arterial reconstructive and graft failures. Histopathologically, this process is characterized by a proliferation of SMC in the intima of traumat...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1991.tb00758.x

    authors: Painter TA

    更新日期:1991-02-01 00:00:00

  • The mitroflow pericardial valve. First results of a follow-up study.

    abstract::One hundred eighty-eight Mitroflow pericardial valves, implanted on 166 patients from March 1983 to December 1986, have been followed for a total of 4316 patients x months. Mortality rate in the first three postoperative months is approximately 10% related to noncardiac complications. One hundred forty-nine patients a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02781.x

    authors: Loisance D,Hillion ML,Cachera JP

    更新日期:1988-08-01 00:00:00