Adult polycystic kidney disease: who needs hospital follow-up?

Abstract:

:Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on whether annualized fall in estimated glomerular filtration rate (ΔeGFR mL/min/1.73 m(2) /year) was statistically significant or not. Only 26 patients (22%) had a statistically significantly decreasing ΔeGFR with a median decrease of -2.6 mL/min/1.73 m(2) /year (range -6.2 to -0.7). There was no difference in initial age, gender, or racial distributions between the groups or in initial eGFR. Follow-up was longer (median 86, range 23-172 months vs. 46, range 3-161 months; P = 0.002) and initial blood pressure values tended to be lower (with mean systolic values of 128 vs. 148 mm Hg; P = 0.02) in the group with statistically significant fall in ΔeGFR, but this trend failed to achieve an a priori level of statistical significance. However, the proportion of patients with initial systolic blood pressure ≤ 144 developing a statistically significant fall in ΔeGFR was 0.26 (95% confidence interval = 0.13 to 0.45). No differences were found in initial hemoglobin or cholesterol concentrations. Overall, the annualized rate of decrease in eGFR tended to be greater in those with the higher initial eGFR (P = 0.04), but correlation was poor (rho(2) = 0.04) and failed to achieve an a priori level of statistical significance. No statistically significant correlation was found between ΔeGFR and any other variable. Only those patients with polycystic kidney disease with a statistically significant annualized decrease in eGFR may need to be referred for hospital follow-up in the renal clinic. This simple selection would reduce referrals by 78%.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Griveas I,Bishop K,World M

doi

10.1111/j.1525-1594.2012.01441.x

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

594-9

issue

7

eissn

0160-564X

issn

1525-1594

journal_volume

36

pub_type

杂志文章
  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle.

    abstract::Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mai...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06258.x

    authors: Lanmüller H,Sauermann S,Unger E,Schnetz G,Mayr W,Bijak M,Girsch W

    更新日期:1999-04-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Biomechanical properties of decellularized porcine pulmonary valve conduits.

    abstract::Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00452.x

    authors: Seebacher G,Grasl C,Stoiber M,Rieder E,Kasimir MT,Dunkler D,Simon P,Weigel G,Schima H

    更新日期:2008-01-01 00:00:00

  • Termination of extracorporeal membrane oxygenation for cardiac support.

    abstract::The determination of when to stop extracorporeal membrane oxygenation (ECMO) rests upon demonstration of the return of adequate cardiac function to support vital organs and permit subsequent recovery. In general, patients with myocardial stun will recover function within several days. Factors that limit recovery inclu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06445.x

    authors: Steinhorn DM

    更新日期:1999-11-01 00:00:00

  • Probing expert opinions on the future of kidney replacement therapies.

    abstract::Patients with kidney failure can only survive with some form of kidney replacement (transplant or dialysis). Unfortunately, innovations in kidney replacement therapy lag behind many other medical fields. This study compiles expert opinions on candidate technologies for future kidney replacement therapies. A worldwide ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13784

    authors: Pereira Cabral B,Bonventre JV,Wieringa F,Mota FB

    更新日期:2020-07-22 00:00:00

  • Heart valve inspired and multi-stream aortic cannula: Novel designs for cardiopulmonary bypass improvement in neonates.

    abstract::In a typical open-heart surgery, the blood flow through the aortic cannula is a critical element of the cardiopulmonary bypass (CPB) procedure. Especially for the neonatal and pediatric CPB flow conditions, the need for small hydraulic diameter and large blood flow results confined turbulent jet flow regimes that exac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13462

    authors: Rasooli R,Pekkan K

    更新日期:2019-10-01 00:00:00

  • Clinical evaluation of a new type of centrifugal pump.

    abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03403.x

    authors: Ninomiya J,Shoji T,Tanaka S,Ikeshita M,Ochi M,Yamauchi S,Yajima T,Yamauchi H,Sugimoto T,Aizawa T

    更新日期:1994-09-01 00:00:00

  • Miniaturized centrifugal ventricular assist device for bridge to decision: Preclinical chronic study in a bovine model.

    abstract::We developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13459

    authors: Shimamura J,Mizuno T,Takewa Y,Tsukiya T,Naito N,Akiyama D,Iizuka K,Katagiri N,Nishimura T,Ono M,Tatsumi E

    更新日期:2019-09-01 00:00:00

  • The role of PI3K/Akt signaling pathway in non-physiological shear stress-induced platelet activation.

    abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13465

    authors: Chen Z,Li T,Kareem K,Tran D,Griffith BP,Wu ZJ

    更新日期:2019-09-01 00:00:00

  • Albumin-coated Amberlite XAD-7 resin for hemoperfusion in acute liver failure. Part II: in vivo evaluation.

    abstract::Albumin-coated Amberlite XAD-7 has been previously shown to be blood compatible in in vitro hemoperfusion experiments whith human blood. In this study, the preliminary results are reported on single hemoperfusions with albumin-coated XAD-7 resin in four patients with acute liver failure. The mean platelet count was 11...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03800.x

    authors: Hughes R,Ton HY,Langley P,Davies M,Hanid MA,Mellon P,Silk DB,Williams R

    更新日期:1979-02-01 00:00:00

  • Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.

    abstract::To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Yambe T,Kobayashi S,Nanka S,Naganuma S,Nitta S,Matsuki H,Abe K,Yoshizawa M,Fukuju T,Tabayashi K,Takeda H,Hashimoto H

    更新日期:1996-06-01 00:00:00

  • Force characteristics of in vivo tissue-engineered myocardial constructs using varying cell seeding densities.

    abstract::Experiments have been successfully performed culminating in functional, vascularized, three-dimensional cardiac muscle tissue. Past experience in tissue engineering has led us to the understanding that cell seeding density plays a critical role in the formation and function of both in vitro and in vivo engineered tiss...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00591.x

    authors: Birla R,Dhawan V,Huang YC,Lytle I,Tiranathanagul K,Brown D

    更新日期:2008-09-01 00:00:00

  • Cryopreservation of fibroblasts immobilized within a porous scaffold: effects of preculture and collagen coating of scaffold on performance of three-dimensional cryopreservation.

    abstract::As a preliminary investigation to establish a cryopreservation method suited for bioartificial livers (BALs), three-dimensional (3-D) cryopreservation experiments with fibroblasts were performed, in which the cells were firstly seeded into a porous scaffold, and the scaffold containing the cells was then cryopreserved...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00933.x

    authors: Miyoshi H,Ehashi T,Ohshima N,Jagawa A

    更新日期:2010-07-01 00:00:00

  • What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

    abstract::Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately cont...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12702

    authors: Naito N,Nishimura T,Takewa Y,Kishimoto S,Date K,Umeki A,Ando M,Ono M,Tatsumi E

    更新日期:2016-11-01 00:00:00

  • Artificial liver: present and future.

    abstract::Early in 1956, the first model of a biological artificial liver, using a live dog's liver incorporated in a cross-hemodialyzer, was placed in an experimental animal with portocaval encephalopathy. This "biological artificial liver," a hybrid artificial liver in the present terminology, was the first in the world. In O...

    journal_title:Artificial organs

    pub_type: 历史文章,杂志文章

    doi:10.1111/j.1525-1594.1986.tb02548.x

    authors: Hori M

    更新日期:1986-06-01 00:00:00

  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Coronary artery bypass grafting for dialysis patients: usefulness of multiarterial bypass.

    abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Nakayama Y,Sakata R,Ura M

    更新日期:2001-04-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Utilization of activated carbon hemoperfusion to assist recovery of ischemically damaged canine liver allografts.

    abstract::The sensitivity of liver allografts to even minimal periods of ischemia currently limits the duration of hepatic preservation prior to liver transplantation. This study evaluates the role of activated carbon hemoperfusion (ACH) for assisting the recovery of canine livers ischemically damaged by a 20-min occlusion of t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04386.x

    authors: Toledo-Pereyra LH

    更新日期:1985-08-01 00:00:00

  • Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing.

    abstract::To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We st...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00244.x

    authors: Dobsák P,Novakova M,Baba A,Vasku J,Isoyama T,Saito I,Abe Y,Chinzei T,Imachi K

    更新日期:2006-06-01 00:00:00

  • In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.

    abstract::The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygen...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12912

    authors: Wang S,Caneo LF,Jatene MB,Jatene FB,Cestari IA,Kunselman AR,Ündar A

    更新日期:2017-09-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Short hemodialysis: long-term mortality and morbidity.

    abstract::Individualized short hemodialysis treatment schedules, approximately three 3-h treatments per week, were introduced in a nephrology unit in 1976. In May 1985, 259 patients had been treated, which corresponds to approximately 60 new patients per million inhabitants per year. Ages at start of therapy ranged between 17 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02541.x

    authors: Wauters JP,Bercini-Pansiot S,Gilliard N,Stauffer JC

    更新日期:1986-06-01 00:00:00

  • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.

    abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02279.x

    authors: Allen R,Frost TH,Hoenich NA

    更新日期:1995-11-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Treatment of severe hyperlipidemia: six years' experience with low-density lipoprotein apheresis.

    abstract::In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04455.x

    authors: Bambauer R,Schiel R,Latza R,Klinkmann J

    更新日期:1996-04-01 00:00:00

  • Multicenter Experience With Mechanical Circulatory Support Using a New Diagonal Pump in 233 Children.

    abstract::Technological innovations in pediatric extracorporeal life support circuits can reduce system-related complications and may improve patients' outcome. The Deltastream DP3 (Medos Medizintechnik AG, Stolberg, Germany) is a novel rotational pump with a diagonally streamed impeller that can be used over a broad range of f...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.13016

    authors: Stiller B,Houmes RJ,Rüffer A,Kumpf M,Müller A,Kipfmüller F,Köditz H,Herber Jonat S,Schmoor C,Benk C,Tibboel D,Fleck T

    更新日期:2018-04-01 00:00:00