Probing expert opinions on the future of kidney replacement therapies.

Abstract:

:Patients with kidney failure can only survive with some form of kidney replacement (transplant or dialysis). Unfortunately, innovations in kidney replacement therapy lag behind many other medical fields. This study compiles expert opinions on candidate technologies for future kidney replacement therapies. A worldwide web-based survey was conducted with 1566 responding experts, identified from scientific publications on kidney (renal) replacement therapy, indexed in the Web of Science Core Collection (period 2014-2019). Candidate innovative approaches were categorized in line with the Kidney Health Initiative roadmap for innovative kidney replacement therapies. Most respondents expected a revolution in kidney replacement therapies: 68.59% before 2040 and 24.85% after 2040, while 6.56% expected none. Approaches anticipated as most likely were implantable artificial kidneys (38.6%) and wearable artificial kidneys (32.4%). A majority of experts expect that kidney replacement therapies can be significantly improved by innovative technologies.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Pereira Cabral B,Bonventre JV,Wieringa F,Mota FB

doi

10.1111/aor.13784

subject

Has Abstract

pub_date

2020-07-22 00:00:00

eissn

0160-564X

issn

1525-1594

pub_type

杂志文章
  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • Opening-wedge high tibial osteotomy with and without bone graft.

    abstract::Medial opening-wedge has gained popularity in comparison to other techniques of high tibial osteotomy. This technique involves the creation of a gap in the tibia. Filling the gap with autologous iliac bone graft was recommended in the classic description, to prevent complications such as correction loss or delayed bon...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2010.01058.x

    authors: Zorzi AR,da Silva HG,Muszkat C,Marques LC,Cliquet A Jr,de Miranda JB

    更新日期:2011-03-01 00:00:00

  • Improved liver function following treatment with an extracorporeal liver assist device.

    abstract::A 68-year-old woman with fulminant hepatic failure of unknown etiology was treated with a bioartificial liver assist device. Prior to treatment, she had a number of clinical and laboratory features that suggested a hopeless outcome. Treatment was associated with a dramatic change in her mental status, and her clinical...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00381.x

    authors: Sussman NL,Kelly JH

    更新日期:1993-01-01 00:00:00

  • Atrial versus ventricular cannulation for a rotary ventricular assist device.

    abstract::The ventricular assist device inflow cannulation site is the primary interface between the device and the patient. Connecting these cannulae to either atria or ventricles induces major changes in flow dynamics; however, there are little data available on precise quantification of these changes. The objective of this i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01093.x

    authors: Timms D,Gregory S,Hsu PL,Thomson B,Pearcy M,McNeil K,Fraser J,Steinseifer U

    更新日期:2010-09-01 00:00:00

  • Computational flow optimization of rotary blood pump components.

    abstract::In an effort to improve and automate the fluid dynamic design of rotary blood pumps, a coupled computational fluid dynamics (CFD) shape optimization methodology has been developed and implemented. This program couples a finite element flow simulation with a gradient-based optimization routine to modify automatically t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02389.x

    authors: Antaki JF,Ghattas O,Burgreen GW,He B

    更新日期:1995-07-01 00:00:00

  • Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios.

    abstract::The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00951.x

    authors: Dur O,Lara M,Arnold D,Vandenberghe S,Keller BB,DeGroff C,Pekkan K

    更新日期:2009-11-01 00:00:00

  • Development and clinical assay of the BCM ventricular assist device.

    abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03364.x

    authors: del Cañizo JF,Antoranz JC,Desco MM,Alvarez-Valdivielso JM,Fernandez-Caleya D,López M,Garcia-Barreno P,Duarte J

    更新日期:1994-07-01 00:00:00

  • A clinical monitoring system for centrifugal blood pumps.

    abstract::In clinical application of rotary blood pumps, flow obstruction as a result of suction of the inflow cannula, kinking of tubing, or thrombus formation occurs quite frequently. Early detection of such problems is essential to avoid hemolysis, tissue degradation, or release of thrombi to the patient. A program was devel...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02409.x

    authors: Holzer S,Scherer R,Schmidt C,Schwendenwein I,Wieselthaler G,Noisser R,Schima H

    更新日期:1995-07-01 00:00:00

  • Restoration of muscle volume and shape induced by electrical stimulation of denervated degenerated muscles: qualitative and quantitative measurement of changes in rectus femoris using computer tomography and image segmentation.

    abstract::This study demonstrates in a novel way how volume and shape are restored to denervated degenerated muscles due to a special pattern of electrical stimulation. To this purpose, Spiral Computer Tomography (CT) and special image processing tools were used to develop a method to isolate the rectus femoris from other muscl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00610.x

    authors: Gargiulo P,Vatnsdal B,Ingvarsson P,Knútsdóttir S,Gudmundsdóttir V,Yngvason S,Helgason T

    更新日期:2008-08-01 00:00:00

  • A compact mock circulation loop for the in vitro testing of cardiovascular devices.

    abstract::In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing. A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device's ability to treat pathological conditions. To serve this purpose, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01088.x

    authors: Timms DL,Gregory SD,Greatrex NA,Pearcy MJ,Fraser JF,Steinseifer U

    更新日期:2011-04-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Systemic consequences of ventricular assist devices: alterations of coagulation, immune function, inflammation, and the neuroendocrine system.

    abstract::Implantable ventricular assist devices have proven efficacious as a bridge to transplantation and as a bridge to recovery. Although current indications for use of assist devices are somewhat limited, they are likely to expand in the upcoming years, including their use as destination therapy for end-stage heart failure...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07122.x

    authors: Hampton CR,Verrier ED

    更新日期:2002-11-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • Utilization of activated carbon hemoperfusion to assist recovery of ischemically damaged canine liver allografts.

    abstract::The sensitivity of liver allografts to even minimal periods of ischemia currently limits the duration of hepatic preservation prior to liver transplantation. This study evaluates the role of activated carbon hemoperfusion (ACH) for assisting the recovery of canine livers ischemically damaged by a 20-min occlusion of t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04386.x

    authors: Toledo-Pereyra LH

    更新日期:1985-08-01 00:00:00

  • Improved retention of endothelial cells seeded on polyurethane small-diameter vascular grafts modified by a recombinant RGD-containing protein.

    abstract::Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07141.x

    authors: Hsu SH,Sun SH,Chen DC

    更新日期:2003-12-01 00:00:00

  • Numerical simulations of blood flow in artificial and natural hearts with fluid-structure interaction.

    abstract::This article describes two ongoing numerical studies of fluid-structure interaction in the cardiovascular system: an idealized pulsatile ventricular assist device (VAD), consisting of two fluid chambers separated by a flexible diaphragm; and blood flow and heart wall motion during passive filling of a canine heart. Si...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00644.x

    authors: Doyle MG,Vergniaud JB,Tavoularis S,Bourgault Y

    更新日期:2008-11-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Heparin coating of small-caliber decellularized xenografts reduces macrophage infiltration and intimal hyperplasia.

    abstract::Small-caliber decellularized xenografts with surface heparin coating are known to reduce in vivo thrombogenicity. This study was performed to examine whether heparin coating on the small-caliber decellularized xenografts would reduce macrophage infiltration and intimal hyperplasia. In a rabbit model of bilateral carot...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00748.x

    authors: Cai WW,Gu YJ,Wang XN,Chen CZ

    更新日期:2009-06-01 00:00:00

  • Venoarterial extracorporeal membrane oxygenation for postcardiotomy cardiogenic shock-A six-year service evaluation.

    abstract::Only a small number of English hospitals provide postcardiotomy venoarterial extracorporeal membrane oxygenation (VA-ECMO) and there are doubts about its efficacy and safety. The aim of this service evaluation was to determine local survival rates and report on patient demographics. This was a retrospective service ev...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13647

    authors: Charlesworth M,Garcia M,Head L,Barker JM,Ashworth AD,Barnard JB,Feddy L,Venkateswaran RV

    更新日期:2020-07-01 00:00:00

  • Pump Speed Waveform Analysis to Detect Aortic Valve Opening in Patients on Ventricular Assist Device Support.

    abstract::As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12570

    authors: Hayward C,Lim CP,Schima H,Macdonald P,Moscato F,Muthiah K,Granegger M

    更新日期:2015-08-01 00:00:00

  • Influence of different hemodialysis membranes on red blood cell susceptibility to oxidative stress.

    abstract::Oxidative stress is crucial in red blood cell (RBC) damage induced by activated neutrophils in in vitro experiments. The aim of the study was to evaluate whether the bioincompatibility phenomena occurring during hemodialysis (HD) (where neutrophil activation with increased free radical production is well documented) m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06432.x

    authors: Lucchi L,Bergamini S,Botti B,Rapanà R,Ciuffreda A,Ruggiero P,Ballestri M,Tomasi A,Albertazzi A

    更新日期:2000-01-01 00:00:00

  • Expression of inflammation in myocardial tissue of rabbits: comparison of two miniaturized heart-lung machines.

    abstract::The majority of cases involving the surgical treatment of congenital heart disease require implementation of cardiopulmonary bypass (CPB). However, neonates and infants are particularly prone to serious complications associated with CPB as a result of capillary leak due to cardiovascular failure. These complications a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12025

    authors: Schnoering H,Arens J,Detering SM,Sachweh JS,Goetzenich A,Schmitz-Rode T,Steinseifer U,Vazquez-Jimenez JF

    更新日期:2013-06-01 00:00:00

  • A novel method to evaluate thromboresistance of drip chambers with filter used in extracorporeal blood circuits for hemodialysis.

    abstract::We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were for...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00354.x

    authors: Yamazaki M,Kobayashi K,Mori Y,Satoh T,Kubota S

    更新日期:1997-02-01 00:00:00

  • Apheresis technologies: an international perspective.

    abstract::The developments in apheresis techniques and their clinical applications world-wide are technologically driven. In the past, apheresis survey statistics have high-lighted both the differences by region in clinical practice and in the types of technologies utilized. Such differences have provided a basis for the scient...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02334.x

    authors: Malchesky PS,Bambauer R,Horiuchi T,Kaplan A,Sakurada Y,Samuelsson G

    更新日期:1995-04-01 00:00:00

  • Hemoperfusion and DNA synthesis in the rat liver. Part I: the effect of hemoperfusion on the rate of DNA synthesis.

    abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04080.x

    authors: Ryan CJ,Courtney JM,Wood CB,Blumgart LH

    更新日期:1982-05-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • Experimental high-volume hemofiltration with predilutional tris-hydroxymethylaminomethane for correction of low tidal volume ventilation-induced acidosis.

    abstract::The most common method of controlling acidemia during lung-protective ventilation is CO₂ removal with an extracorporeal lung assist (ECLA) system. Another possibility to prevent acidemia is based on intravenous (i.v.) application of tris-hydroxymethyl-aminomethane (3 mol/L, THAM) buffer, which can bind hydrogen proton...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01204.x

    authors: Russ M,Deja M,Ott S,Bedarf J,Keckel T,Hiebl B,Wagner JJ,Unger JK

    更新日期:2011-06-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Effect of moisture on and kinetic features of the ultrafiltration rate of dialysis membrane.

    abstract::The kinetic features of ultrafiltration of cellulose dialysis membrane stored under various humidity and temperature conditions were studied to obtain basic information of shelf-life characteristics of dialyzers. The ultrafiltration rate (UFR) decreased with time and the UFR-time curve suggested that the UFR would app...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04003.x

    authors: Sato H,Kidaka T

    更新日期:1981-08-01 00:00:00

  • Temporary right heart assist: a minimally invasive approach.

    abstract::A surgical method for the implantation of a mechanical right ventricular assist device which avoids resternotomy/thoracotomy and related complications at the time of explantation is presented. In order to support the failing right heart, a Dacron vascular graft was sewn to the pulmonary artery. For venous drainage, a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01520.x

    authors: Schopka S,Haneya A,Rupprecht L,Camboni D,Schmid C,Hilker M

    更新日期:2012-08-01 00:00:00