Long-term performance of homograft and autograft valves.

Abstract:

:Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giving an incidence of one embolism per 143,928 patient months. Degeneration occurred in 14% of the autografts, in 30% of the freeze dried and in 60% of the frozen homografts after ten years. Eighty per cent of the fresh homografts have been free of degeneration after seven years, and 54% of freeze-dried valves have been free of degeneration after 14 years. Long-term performance of homograft and autograft valves in the aortic positon is comparable to that of any prosthetic or bioprosthetic valve. In addition, they are non-thrombogenic and excellent in terms of patient survival.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Bodnar E,Wain WH,Martelli V,Ross DN

doi

10.1111/j.1525-1594.1980.tb03894.x

subject

Has Abstract

pub_date

1980-02-01 00:00:00

pages

20-3

issue

1

eissn

0160-564X

issn

1525-1594

journal_volume

4

pub_type

杂志文章
  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Single-center experience with partial support device in destination therapy for end-stage heart failure.

    abstract::Ventricular assist devices (VADs) are considered the standard of care for end-stage heart failure (HF) patients. Despite increasing confidence in the technology, evidence data, endorsement by scientific societies and guidelines, the number of implants reached a steady state and is not increasing at the expected pace. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13714

    authors: Barbone A,Pagliaro B,Basciu A,Iaccarino A,Droandi G,Romano G,Citterio E,Fumero A,Torracca L,Pini D

    更新日期:2020-04-23 00:00:00

  • Arterial pressure: its role in perfusion and as a criterion of extracorporeal circulation adequacy.

    abstract::Thirty-five patients undergoing open-heart surgery are reported. Cardiac index, mean arterial pressure, oxygen consumption, lactate, pyruvate, and lactate excess in the blood were measured. An inverse correlation of arterial pressure with oxygen consumption and lactate excess was found during perfusion. Comparison of ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb01675.x

    authors: Osipov VP,Khodas MJ,Dementjeva II,Pjatnitskaja GKh

    更新日期:1982-08-01 00:00:00

  • Intra-Aortic Balloon Pump Support in the Isolated Beating Porcine Heart in Nonischemic and Ischemic Pump Failure.

    abstract::The blood pressure changes induced by the intra-aortic balloon pump (IABP) are expected to create clinical improvement in terms of coronary perfusion and myocardial oxygen consumption. However, the measured effects reported in literature are inconsistent. The aim of this study was to investigate the influence of ische...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12470

    authors: Schampaert S,van Nunen LX,Pijls NH,Rutten MC,van Tuijl S,van de Vosse FN,van 't Veer M

    更新日期:2015-11-01 00:00:00

  • The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.

    abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05074.x

    authors: Nawrat Z,Malota Z

    更新日期:1998-10-01 00:00:00

  • Binding of antithrombin to immobilized heparin under varying flow conditions.

    abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Pasche B,Elgue G,Olsson P,Riesenfeld J,Rasmuson A

    更新日期:1991-12-01 00:00:00

  • The accurate control of ultrafiltration.

    abstract::An apparatus has been contructed to regulate ultrafiltration accurately during dialysis. The principle of the apparatus is that, per unit of time, exactly the same amount of dialysate is introduced into the dialyzer as is discharged from it. The apparatus consists of two isovolumetric pumps connected in line. The four...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03442.x

    authors: Flendrig JG,Carpay WM,Dekkers WT

    更新日期:1978-05-01 00:00:00

  • Hemolysis test of a centrifugal pump in a pulsatile mode: the effect of pulse rate and RPM variance.

    abstract::Centrifugal pumps are generally employed as nonpulsatile blood flow pumps; however, these pumps can produce pulsatile flow by periodically alternating the impeller rotation speed. This study investigates blood trauma due to the effect of pulse frequency and various ranges of pump speed. The hemolysis tests were conduc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00489.x

    authors: Tayama E,Niimi Y,Takami Y,Ohashi Y,Ohtsuka G,Glueck JA,Mueller J,Nosé Y

    更新日期:1997-12-01 00:00:00

  • Results of the European clinical trial of Arrow CorAide left ventricular assist system.

    abstract::The aim of this study was to evaluate the safety and performance of the Arrow CorAide left ventricular assist system (LVAS) (Arrow International, Reading, PA, USA), a continuous-flow left ventricular assist device, as bridge to transplantation or recovery as well as destination therapy in patients with New York Heart ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.2012.01539.x

    authors: Saeed D,Arusoglu L,Gazzoli F,Hetzer R,Morshius M,Alloni A,Viganò M,Koerfer R,Golding LA,El Banayosy A

    更新日期:2013-02-01 00:00:00

  • Beta-2-microglobulin and main granulocyte components in hemodialysis patients.

    abstract::Plasma levels of granulocyte elastase in complex with alpha 1-proteinase inhibitor (E-alpha 1-PI) increased during hemodialysis from 110 +/- 10 to 506 +/- 66 micrograms/L using dialyzers made of polyamide, from 95 +/- 2.2 to 211 +/- 54 micrograms/ml with hemophane and from 114 +/- 10 to 203 +/- 25 using dialyzers made...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02842.x

    authors: Haag-Weber M,Schollmeyer P,Hörl WH

    更新日期:1989-04-01 00:00:00

  • Effect of a balanced biventricular bypass system on left ventricular energies.

    abstract::Left dominant biventricular failure is a common type of heart failure after cardiac surgery. We developed a biventricular bypass (BVB) system for treatment of postcardiotomy ventricular failure, and we previously reported that the clinical results of the BVB system were superior to those obtained with venoarterial byp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06015.x

    authors: Kodera K,Kitamura M,Shibuya M,Kurihara H,Koyanagi H

    更新日期:1998-09-01 00:00:00

  • Differential functional coupling between human saphenous cryoallografts and arteries: importance of the arterial type and the biomechanical parameter evaluated.

    abstract::The aim of this study was to characterize and compare human great saphenous veins (HGSVs), HGSV cryoallografts, expanded polytetrafluoroethylene (ePTFE) segments, and elastic and muscular arteries' biomechanics, so as to identify if the biomechanical coupling and the HGSV advantages with respect to ePTFE depend on the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00467.x

    authors: Bia D,Zócalo Y,Pessana F,Armentano R,Pérez H,Saldías M,Alvarez I

    更新日期:2007-11-01 00:00:00

  • Dialyzer reuse: interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing.

    abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04418.x

    authors: Ng YY,Yang AH,Wong KC,Lan HY,Hung TL,Kerr PG,Huang TP

    更新日期:1996-01-01 00:00:00

  • Elective decompression of the left ventricle in pediatric patients may reduce the duration of venoarterial extracorporeal membrane oxygenation.

    abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12390

    authors: Hacking DF,Best D,d'Udekem Y,Brizard CP,Konstantinov IE,Millar J,Butt W

    更新日期:2015-04-01 00:00:00

  • Complication profile of the Berlin Heart EXCOR biventricular support in children.

    abstract::In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12062

    authors: Schweiger M,Schrempf J,Sereinigg M,Prenner G,Tscheliessnigg KH,Wasler A,Krumnikel J,Gamillschegg A,Knez I

    更新日期:2013-08-01 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Is low-intensity anticoagulant therapy possible with an open pivot valve?: analysis of its development.

    abstract::In 1976, the authors became the codevelopers of the first successful bileaflet heart valve which has become the standard in valvular surgery. However, there still remains a significant rate of thromboembolism and thrombosis which can be attributed to the inherent design of cavities in the pivot area. These cavities co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06999.x

    authors: Nicoloff DM,Friedberg HD,Villafaña MA

    更新日期:2002-05-01 00:00:00

  • An In Vitro Feasibility Study of the Influence of Configurations and Leaflet Thickness on the Hydrodynamics of Deformed Transcatheter Aortic Valve.

    abstract::Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. Even in the same deformation, the leaflets made in different tissue thickne...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12833

    authors: Feng W,Yang X,Liu Y,Fan Y

    更新日期:2017-08-01 00:00:00

  • Extracorporeal endotoxin removal by immobilized polyethylenimine.

    abstract::The neutralization of bacterial endotoxins (ET) is still an unsolved problem in therapeutic medicine. The efficacy of anti-endotoxin antibodies or receptor antagonists and other substances interfering with the endotoxin-induced pathomechanisms is dependent on an intact cellular degradation system of the host. However,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00630.x

    authors: Mitzner S,Schneidewind J,Falkenhagen D,Loth F,Klinkmann H

    更新日期:1993-09-01 00:00:00

  • Flow through an outlet cannula of a rotary ventricular assist device.

    abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06931_4.x

    authors: Manning KB,Miller GE

    更新日期:2002-08-01 00:00:00

  • Renal effects of multiple infusion of pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) solution in dogs.

    abstract::Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP), which is made from out-dated human red blood cells by two major chemical modifications, namely pyridoxalation and conjugation with polyoxyethylene (POE), is currently under development as a physiological oxygen carrier. This study assessed the effects of PHP-88...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00424.x

    authors: Takahashi T,Iwasaki K,Malchesky PS,Harasaki H,Matsushita M,Nosé Y,Rolin H 3rd,Hall PM

    更新日期:1993-03-01 00:00:00

  • Effect of age on calcification of poly(hydroxyethyl methacrylate) in animals.

    abstract::The effect of age on the calcification of biomaterials was studied by the subcutaneous implantation of poly(hydroxyethyl methacrylate) hydrogel in rats. The hydrogel sheets were implanted in rats 6, 12, 24, and 52 weeks (1 year) of age. The retrieved implants were compared and the percentage weight increase by mineral...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04388.x

    authors: Imai Y

    更新日期:1985-08-01 00:00:00

  • A compact mock circulation loop for the in vitro testing of cardiovascular devices.

    abstract::In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing. A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device's ability to treat pathological conditions. To serve this purpose, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01088.x

    authors: Timms DL,Gregory SD,Greatrex NA,Pearcy MJ,Fraser JF,Steinseifer U

    更新日期:2011-04-01 00:00:00

  • Is ionic dialysance a valid parameter for quantification of dialysis efficiency?

    abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06062.x

    authors: Mercadal L,Petitclerc T,Jaudon MC,Béné B,Goux N,Jacobs C

    更新日期:1998-12-01 00:00:00

  • Paper is a compatible bed for rat hepatocytes.

    abstract::To develop an effective hybrid bioartificial liver (BAL) device, the material of the scaffold is very important to support hepatocytes that have both growth ability and hepatic differentiated functions. In this study we used paper (Kimwipe, Kimberly-Clark Corp., Roswell, GA, U.S.A.) as a scaffold. Primary hepatocytes ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06506.x

    authors: Mizuguchi T,Mitaka T,Sato F,Mochizuki Y,Hirata K

    更新日期:2000-04-01 00:00:00

  • Assessment of five interleukins in human synovial fluid as possible markers for aseptic loosening of hip arthroplasty.

    abstract::One of the most important factors that seems to be involved in total hip replacement is periprosthetic osteolysis. As it is well documented that several interleukins (ILs) are triggered in periprosthetic osteolysis, this article investigates the role of five ILs in primary and replacement total hip arthroplasty, under...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00736.x

    authors: Beraudi A,Stea S,Cremonini S,Visentin M,Toni A

    更新日期:2009-07-01 00:00:00

  • A hemoglobin-based multifunctional therapeutic: polynitroxylated pegylated hemoglobin.

    abstract::Polynitroxylated pegylated hemoglobin (PNPH) as a multifunctional therapeutic takes advantage of the ability of hemoglobin (Hb) to transport oxygen, the antioxidative stress activities from the redox coupling of nitroxide and heme iron, and the hypercolloid properties of pegylation. The published preclinical data demo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01307.x

    authors: Hsia CJ,Ma L

    更新日期:2012-02-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Ripple reduction control of the undulation pump total artificial heart.

    abstract::An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06798.x

    authors: Saito I,Chinzei T,Mochizuki S,Abe Y,Isoyama T,Iwasaki K,Suzuki T,Karita T,Ono T,Kouno A,Ishimaru M,Baba A,Ozeki T,Tohyama T,Kobayashi Si S,Imachi K

    更新日期:2002-01-01 00:00:00

  • A newly designed adapter for testing an ex vivo mitral valve apparatus.

    abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06293.x

    authors: Katoh T,Ikeda N,Nishi K,Gohra H,Hamano K,Noda H,Fujimura Y,Esato K

    更新日期:1999-10-01 00:00:00