Abstract:
:The sensitivity of liver allografts to even minimal periods of ischemia currently limits the duration of hepatic preservation prior to liver transplantation. This study evaluates the role of activated carbon hemoperfusion (ACH) for assisting the recovery of canine livers ischemically damaged by a 20-min occlusion of the portal vein and hepatic artery prior to organ harvesting. Animals in Group I (n = 5) receiving damaged liver allografts without ACH survived a mean (+/- SD) of 18.0 +/- 13.5 h. One ACH treatment given to recipients immediately after liver transplantation in Group II (n = 5) resulted in improved survival to a mean of 3.8 +/- 2.16 days (p less than 0.05). The best survival was obtained after three ACH treatments in Group III (n = 6) on days 0, 1, and 2 (26.6 +/- 27.1 days) (p less than 0.05). These results indicate that ACH may be helpful in assisting the recovery of ischemically damaged liver allografts after transplantation.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Toledo-Pereyra LHdoi
10.1111/j.1525-1594.1985.tb04386.xsubject
Has Abstractpub_date
1985-08-01 00:00:00pages
243-9issue
3eissn
0160-564Xissn
1525-1594journal_volume
9pub_type
杂志文章abstract::Nonpulsatile blood pumps are mainly used in extracorporeal life support systems. Although pulsating blood flow is known to be physiological, a pulsatile pump is not commonly applied in a circuit with a membrane oxygenator because of damage to the blood cells. The hypothesis that the placement of a pressure-relieving c...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.07341.x
更新日期:2004-12-01 00:00:00
abstract::Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00261.x
更新日期:2006-07-01 00:00:00
abstract::The coronary arteries of the goat heart were studied using angiographic techniques and molds of the coronary vessel trees. Blood supplies to the left and right ventricles, interventricular septum, atrioventricular node, and apex of the caprine heart were studied. The goat possesses a left dominant pattern of coronary ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04192.x
更新日期:1983-05-01 00:00:00
abstract::A comparative assessment has been made regarding efficacy and safety of the double filtration plasmapheresis (DFPP), thermofiltration (TFPP), and low-density lipoprotein (LDL) adsorptive (PA) methods by making a crossover test on heterozygous familial hypercholesterolemia patients. Treatments by DFPP, TFPP (secondary ...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1996.tb04448.x
更新日期:1996-04-01 00:00:00
abstract::Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP), which is made from out-dated human red blood cells by two major chemical modifications, namely pyridoxalation and conjugation with polyoxyethylene (POE), is currently under development as a physiological oxygen carrier. This study assessed the effects of PHP-88...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00424.x
更新日期:1993-03-01 00:00:00
abstract::The effects of pyridoxalated hemoglobin polyoxyethylene conjugate (PHP) and other hemoglobin-related substances on arterial blood pressure (ABP) and heart rate (HR) were examined. Infusion of PHP and other hemoglobin-related substances elevated ABP and increased HR. The degree of the increase in ABP and HR did not dif...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02300.x
更新日期:1995-02-01 00:00:00
abstract::Tubular polymer scaffolds based on tissue engineering techniques have been studied as potential alternatives for vascular regeneration implants. The blood vessels of the cardiovascular system are mainly fibrous, composed of collagen (Col) and elastin (El), and its inner layer consists of endothelial cells. In this wor...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13857
更新日期:2020-11-10 00:00:00
abstract::A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male piv...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.6184r.x
更新日期:1998-09-01 00:00:00
abstract::Plasma procoagulant activities of factors XII, XI, IX, and VIII and plasma concentrations of factor XII antigen and high molecular weight kininogen (HMK) were determined in nine men with chronic renal failure (CRF) associated with long-standing spinal cord injury (SCI) treated with hemodialysis. The results were compa...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1985.tb04366.x
更新日期:1985-05-01 00:00:00
abstract::Five typical mechanical heart valves (Starr-Edwards, Björk-Shiley convexo-concave (c-c), Björk-Shiley monostrut, Bicer-Val, and St. Jude Medical) were tested in the mitral position under the pulsatile flow condition. The test program included measurements of velocity and turbulent stresses at 5 downstream locations. T...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00451.x
更新日期:1997-10-01 00:00:00
abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1982.tb04080.x
更新日期:1982-05-01 00:00:00
abstract::Many patients all over the world suffer from acute wounds caused by traumas or burns. In most crucial cases, skin regeneration cannot be promoted spontaneously, and skin grafts are applied as the main treatment. However, this therapy has some drawbacks which motivate researchers to develop wound dressings. In this stu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12682
更新日期:2016-08-01 00:00:00
abstract::This study evaluates the effect of poly(L-lactic acid) (PLLA) and poly(hydroxybutyrate-cohydroxyvalerate) (PHBV) bioabsorbable polymers and their blends on the induction of alteration of cell growth pattern in vitro. Vero cells were cultured on PLLA, PHBV, and different blends (100/0, 60/40, 50/50, 40/60, and 0/100). ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.47199.x
更新日期:2004-04-01 00:00:00
abstract::During revision of a failed acetabular component with well-fixed antiquated femoral stem, the same variant of metal head is usually not available in the inventory production. We gathered the stems retrieved from revision surgeries and tried to reassemble with the commercially available femoral heads. This study report...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01015.x
更新日期:2010-08-01 00:00:00
abstract::Percutaneous pulmonary valve implantation is a potential treatment for right ventricular outflow tract (RVOT) dysfunction. However, RVOT implantation site varies among subjects and the success of the procedure depends on RVOT morphology selection. The aim of this study was to use in vitro testing to establish percutan...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00673.x
更新日期:2009-01-01 00:00:00
abstract::This article describes a new powering system for implantable medical devices that could significantly increase their lifetime. The idea is based on the substitution of the usual implantable device battery for an electric accumulator (rechargeable battery), which is fed by the electric power generated by a photovoltaic...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00803.x
更新日期:2009-10-01 00:00:00
abstract::We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13795
更新日期:2020-08-19 00:00:00
abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01064.x
更新日期:2011-02-01 00:00:00
abstract::The effectiveness of the blood substitute neo red cells (NRC) on hemorrhagic shock was evaluated in dogs. Shock was induced by bloodletting, and NRC was infused immediately until the dogs recovered from shock; the process was repeated 3 times (mild shock), or NRC was infused after shock was maintained for 30 min, and ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1998-02-01 00:00:00
abstract::The use of Berlin Heart EXCOR VAD (BH) is a validated therapy to bridge pediatric patients to heart transplant. Serial echocardiographic (ECHO) assessment of VAD patients is necessary to support patients' management. This work aims at developing an innovative strategy to evaluate the BH device functioning by ECHO and ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13122
更新日期:2018-04-01 00:00:00
abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12029
更新日期:2013-01-01 00:00:00
abstract::In vitro tests have shown that electric currents may lead either to relaxation or contraction of the bowel wall. Because voluntary changes of the intestinal motility could be useful in the treatment of intestinal disorders, we investigated the reactions elicited by electrostimulation of the small intestine in the inta...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1989.tb02846.x
更新日期:1989-04-01 00:00:00
abstract::Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet n...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13507
更新日期:2019-11-01 00:00:00
abstract::The nanocomposites (denoted "CII-Au") of porcine type II collagen (CII) with 0.05, 0.1, 0.5, 1, or 2.5% (wt/wt) Au nanoparticles ( approximately 5 nm) were fabricated for potential use in cartilage tissue engineering. Au formed clusters on the surface of all nanocomposites and appeared to distribute along the collagen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00482.x
更新日期:2007-12-01 00:00:00
abstract::This article describes two ongoing numerical studies of fluid-structure interaction in the cardiovascular system: an idealized pulsatile ventricular assist device (VAD), consisting of two fluid chambers separated by a flexible diaphragm; and blood flow and heart wall motion during passive filling of a canine heart. Si...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00644.x
更新日期:2008-11-01 00:00:00
abstract::Sera from 138 patients who had experienced hypersensitivity-type reactions while on hemodialysis (reactors) were examined retrospectively by the radioallergosorbent test (RAST) for specific IgE antibody to ethylene oxide (ETO). Seventy-eight hemodialysis patients without a history of reaction were also evaluated as co...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02638.x
更新日期:1987-04-01 00:00:00
abstract::We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03713.x
更新日期:1997-07-01 00:00:00
abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04418.x
更新日期:1996-01-01 00:00:00
abstract::Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. Even in the same deformation, the leaflets made in different tissue thickne...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12833
更新日期:2017-08-01 00:00:00
abstract::The purpose of this paper is to review the pathways of hydrogen ion production and removal due to intermediary metabolism. The principal method of analysis employed was one based on a theoretical approach because it is the most accurate and has the broadest application. In the absence of hypoxia and insulin deficiency...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1982.tb04126.x
更新日期:1982-11-01 00:00:00