Abstract:
:Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. Even in the same deformation, the leaflets made in different tissue thicknesses may cause different hydrodynamic performances. Simulating the left heart cardiac conditions by a pulse duplicator system, the present study investigated the effects of the aortic annulus deformation and the leaflet tissue thickness on the hydrodynamics of the TAV. Three 22 mm self-expanding TAV samples were fabricated with three different leaflet thicknesses (0.25, 0.4, 0.55 mm). Every sample was successively deformed to be elliptical, triangular, and undersized circular shapes. The hydrodynamics of the TAV were assessed through a quasi-physiological artery pulsatile flow duplicator system. The transvalvular pressure difference, effective orifice area, and regurgitation flow were determined. High-speed video recordings were taken to investigate the leaflet kinematics. The results showed that the triangular deformation produced the poorest valve function while the elliptical deformation led to the slightest difference from the nominal. With increasing leaflet thickness, the effect of configuration deformation on the regurgitation increased. The thinner leaflets were better than the thicker ones in adapting to the deformation but had a higher risk of deterioration.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Feng W,Yang X,Liu Y,Fan Ydoi
10.1111/aor.12833subject
Has Abstractpub_date
2017-08-01 00:00:00pages
735-743issue
8eissn
0160-564Xissn
1525-1594journal_volume
41pub_type
杂志文章abstract::Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requiremen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12664
更新日期:2016-10-01 00:00:00
abstract::Individualized short hemodialysis treatment schedules, approximately three 3-h treatments per week, were introduced in a nephrology unit in 1976. In May 1985, 259 patients had been treated, which corresponds to approximately 60 new patients per million inhabitants per year. Ages at start of therapy ranged between 17 a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1986.tb02541.x
更新日期:1986-06-01 00:00:00
abstract::Recent studies show that oxytocin has various effects on cellular behaviors. Oxytocin is reported to stimulate cardiomyogenesis of embryonic stem cells and endothelial cell proliferation. Mesenchymal stem cells (MSCs) are widely used for cardiac repair, and we elucidated the effect of oxytocin on umbilical cord derive...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00894.x
更新日期:2010-06-01 00:00:00
abstract::Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet n...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13507
更新日期:2019-11-01 00:00:00
abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.06981.x
更新日期:2003-08-01 00:00:00
abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06414.x
更新日期:1999-08-01 00:00:00
abstract::We report on 10 patients with acute renal involvement in Hantaan virus infection observed at the Department of Nephrology, Faculty of Medicine, Skopje, Republic of Macedonia, during a period of 3 years (October 1987-July 1990). Eight patients were male and 2 were female, aged 37.5 +/- 4.8 years. The diagnosis of Hanta...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1995.tb02432.x
更新日期:1995-08-01 00:00:00
abstract::This study probed the changes of keratocytes cultured under simulated microgravity. Keratocytes were isolated from rabbit corneas using collagenase digestion method. Cells were seeded in a 55-mL capacity high-aspect-ratio vessel (HARV) of rotary cell culture system (RCCS) at a density of 1 x 10(4) cells/mL. Dehydrated...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00440.x
更新日期:2007-09-01 00:00:00
abstract::A computer simulation was carried out to investigate the influence of nonpulsatile left ventricular assistance on hemodynamics. A simulation circuit was constructed to represent the circulatory system. A source of current was added to denote the nonpulsatile blood pump. The left and right ventricles were replaced by v...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04494.x
更新日期:1996-05-01 00:00:00
abstract::Thirteen percent of 99 patients undergoing maintenance hemodialysis showed an increased predialysis peripheral blood eosinophil count (mean value of 828 cells/mm3, range 410-2,710). Patients with eosinophilia were predominantly male and evidenced more frequent elevation of total plasma IgE levels. Otherwise, no differ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02635.x
更新日期:1987-04-01 00:00:00
abstract::Mycotic aneurysm of the superior mesenteric artery (SMA) is one of the complications associated with infective endocarditis. However, there are no previous case reports in the literature describing mycotic SMA aneurysm after left ventricular assist device (LVAD) implantation. We describe the case of a 31-year-old male...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01250.x
更新日期:2011-07-01 00:00:00
abstract::As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV ...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1111/aor.12570
更新日期:2015-08-01 00:00:00
abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2005.00164.x
更新日期:2005-12-01 00:00:00
abstract::Thrombosis and thromboembolism are the life-threatening clinical complications for patients supported or treated with prosthetic cardiovascular devices. The high mechanical shear stress within these devices is believed to be the major contributing factor to cause platelet activation (PA) and function alteration, leadi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12438
更新日期:2015-07-01 00:00:00
abstract::Long-term hemodialysis catheter dwell time in the central vein predisposes to fibrin sheath development, which subsequently causes catheter malfunction or occlusion. In very rare cases, the catheter can be overgrown with fibrin and rigidly connected with the vein or heart structures. This makes its removal almost impo...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12643
更新日期:2016-05-01 00:00:00
abstract::Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) wa...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12611
更新日期:2016-07-01 00:00:00
abstract::Monoclonal antibodies for targeting cytotoxic conjugates to tumor cells are currently being evaluated together with extracorporeal affinity adsorption. The aim of the adsorption was to reduce undesired side effects in normal organs and to increase the tumor-to-normal tissue ratios. This technique is also applicable to...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00380.x
更新日期:2007-04-01 00:00:00
abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06062.x
更新日期:1998-12-01 00:00:00
abstract::The objective of this clinical study is to determine whether correlation exists among cerebral and renal near-infrared spectroscopy (NIRS) measurements, renal Doppler ultrasonography parameters (resistive index, peak systolic velocity), and early postoperative clinical outcomes following cardiac surgery in neonates an...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12455
更新日期:2015-01-01 00:00:00
abstract::Medial opening-wedge has gained popularity in comparison to other techniques of high tibial osteotomy. This technique involves the creation of a gap in the tibia. Filling the gap with autologous iliac bone graft was recommended in the classic description, to prevent complications such as correction loss or delayed bon...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1525-1594.2010.01058.x
更新日期:2011-03-01 00:00:00
abstract::The aim of this study is to compare the effect of a single diode laser application and agitation of EDTA with diode laser with different parameters at different time intervals on root fracture. Ninety mandibular incisors were instrumented except the negative control group. The specimens were divided randomly into 10 g...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12608
更新日期:2016-06-01 00:00:00
abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...
journal_title:Artificial organs
pub_type: 杂志文章,meta分析
doi:10.1111/aor.12452
更新日期:2015-09-01 00:00:00
abstract::In a multicenter study including 5 dialysis units, blood acetate changes during 4 h dialysis sessions in 141 patients treated with a 4 mM acetate-containing bicarbonate dialysate (ABD) were evaluated and compared to the values of 114 patients using an acetate-free bicarbonate dialysate (AFD). Acetate-free bicarbonate ...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1046/j.1525-1594.1998.06205.x
更新日期:1998-07-01 00:00:00
abstract::To perform the first experimental tests for validation of a new gear unit concept, the pump chamber, diaphragm, and pusher plate design of an orthotopic electromechanical total artificial heart (TAH) (Helmholtz Labtype) was manufactured. In its early stage of development, it provides some of the most important feature...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03374.x
更新日期:1994-07-01 00:00:00
abstract::The DexAide right ventricular assist device (RVAD) has been developed to provide an implantable RVAD option to surgeons. The aim of this study was to determine the optimal cannula design and optimal implantation location of the DexAide RVAD in preparation for its clinical use. Separately, a HeartMate XVE left ventricu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00438.x
更新日期:2007-08-01 00:00:00
abstract::Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00261.x
更新日期:2006-07-01 00:00:00
abstract::Hypotension is an uncommon complication of procedures involving extracorporeal circulation, including plasmapheresis. From November 1993 to March 1999, we treated 139 patients who underwent a total of 1,137 sessions of double filtration plasmapheresis (DFP). Hypotension was defined as a systolic blood pressure (BP) < ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06521.x
更新日期:2000-09-01 00:00:00
abstract::Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04473.x
更新日期:1996-05-01 00:00:00
abstract::Plasma levels of granulocyte elastase in complex with alpha 1-proteinase inhibitor (E-alpha 1-PI) increased during hemodialysis from 110 +/- 10 to 506 +/- 66 micrograms/L using dialyzers made of polyamide, from 95 +/- 2.2 to 211 +/- 54 micrograms/ml with hemophane and from 114 +/- 10 to 203 +/- 25 using dialyzers made...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1989.tb02842.x
更新日期:1989-04-01 00:00:00
abstract::Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extra...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06017.x
更新日期:1998-08-01 00:00:00