Evaluation of double filtration plasmapheresis, thermofiltration, and low-density lipoprotein adsorptive methods by crossover test in the treatment of familial hypercholesterolemia patients.

Abstract:

:A comparative assessment has been made regarding efficacy and safety of the double filtration plasmapheresis (DFPP), thermofiltration (TFPP), and low-density lipoprotein (LDL) adsorptive (PA) methods by making a crossover test on heterozygous familial hypercholesterolemia patients. Treatments by DFPP, TFPP (secondary membrane Evalux 5A), and PA (Liposorber LA-40) were carried out 5 times each, with a 2-week interval, in 5 patients with heterozygous familial hypercholesterolemia. The same plasma separator (Plasmacure PS-60, polysulfone) was used in all cases, and the volume of plasma processed was set at 4 L. High removal rates were obtained of total cholesterol, LDL cholesterol, triglycerides TG, and apolipoprotein B (apoB) by all three methods, and no differences were observed. Lipoprotein (a), apoA-2, apoC-3, fibrinogen, and immunoglobulin M (IgM) showed significantly high removal rates by the DFPP and TFPP methods compared with the PA method. The sieving coefficient of albumin and high-density lipoprotein (HDL) cholesterol at 2 and 4 L of plasma processed exhibited high permeabilities using all three methods. Supplementing albumin was not necessary. An increase of the transmembrane pressure was observed in 1 case treated by DFPP but was not observed when using the TFPP or PA method. No changes were observed in serum interleukin 1beta (IL-1beta) or tumor necrosis factor-alpha (TNF-alpha) before and after treatment by any of the three methods. No remarkable side effects were observed using either the DFPP or TFPP method. The DFPP and TFPP methods showed efficacy and safety that was not inferior to the PA method in conventional LDL apheresis, and the dead-end method of the filter operation without the discarding of plasma was shown to be possible.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Suzuki M,Yamane S,Matsugane T,Nobuto T,Azuma N,Nishide T,Shinomiya M,Saito K,Sasaki N,Nosé Y

doi

10.1111/j.1525-1594.1996.tb04448.x

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

296-302

issue

4

eissn

0160-564X

issn

1525-1594

journal_volume

20

pub_type

临床试验,杂志文章
  • Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

    abstract::In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06228.x

    authors: Mueller XM,Tevaearai HT,Hayoz D,von Segesser LK

    更新日期:1999-02-01 00:00:00

  • Clinical Assessment of Histidine-Tryptophan-Ketoglutarate Solution and Modified St. Thomas' Solution in Pediatric Cardiac Surgery of Tetralogy of Fallot.

    abstract::The objective of this study is to compare the myocardium protective effect of Bretschneider's histidine-tryptophan-ketoglutarate (HTK) solution versus Modified St. Thomas' (STH) solution in pediatric cardiac surgery of Tetralogy of Fallot (TOF). Seventy-seven pediatric patients of TOF who received the total surgical r...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12771

    authors: Wang ZH,An Y,Du MC,Qin TJ,Liu YB,Xu HZ,Yang LQ

    更新日期:2017-05-01 00:00:00

  • Hypertension and end-stage renal disease in the developing world.

    abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07067.x

    authors: El-Khashab O

    更新日期:2002-09-01 00:00:00

  • Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.

    abstract::The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00339.x

    authors: Malagutti N,Karantonis DM,Cloherty SL,Ayre PJ,Mason DG,Salamonsen RF,Lovell NH

    更新日期:2007-01-01 00:00:00

  • Comparison of Centrifugal and Roller Pump Hemolysis Rates at Low Flow.

    abstract::We compared in vitro rates of hemolysis for a recently developed centrifugal pump with a conventional roller pump (10-10-00; Stöckert, Munich, Germany). Flow rates of 0.3 L/min and 1 L/min and a pressure of 200 mm Hg were chosen to simulate conditions during neonatal extracorporeal membrane oxygenation (ECMO). There w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04485.x

    authors: Moon YS,Ohtsubo S,Gomez MR,Moon JK,Nose Y

    更新日期:1996-05-01 00:00:00

  • Tissue reactions to various percutaneous materials with different surface properties and structures.

    abstract::Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetratin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00514.x

    authors: Shin Y,Akao M

    更新日期:1997-09-01 00:00:00

  • Flow pattern analysis of the Baylor total artificial heart.

    abstract::To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03345.x

    authors: Meier D,Wernicke JT,Orime Y,Takatani S,Tasai K,Damm G,Naito K,Mizuguchi K,Makinouchi K,Glueck J

    更新日期:1994-12-01 00:00:00

  • The monomeric formulation optimization of dental composite: mechanical and kinetic studies.

    abstract::The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07250.x

    authors: López Palacio RE,de Carvalho Zavaglia CA

    更新日期:2003-05-01 00:00:00

  • Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.

    abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13626

    authors: Li M,Walk R,Roka-Moiia Y,Sheriff J,Bluestein D,Barth EJ,Slepian MJ

    更新日期:2020-06-01 00:00:00

  • Significant left ventricular unloading with transaortic catheter venting during venoarterial bypass.

    abstract::Insufficient unloading of the left ventricle with blood stagnation is a main cause of unsuccessful left ventricular (LV) recovery during percutaneous cardiopulmonary support (PCPS). The purpose of this investigation was to evaluate the effectiveness of transaortic catheter venting (TACV) for LV unloading. Six adult mo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03744.x

    authors: Shibuya M,Kitamura M,Kurihara H,Kikuchi C,Endo M,Koyanagi H

    更新日期:1997-07-01 00:00:00

  • Effect of hemodialysis on T lymphocyte subsets, con-A-activated suppressor cell activity, and interleukin-2 receptor expression on lymphocytes in chronic uremic patients.

    abstract::Effect of hemodialysis (HD) on some indices of immune response was studied in nine chronic uremics. Total lymphocyte, OKT4+, and OKT8+ cell numbers significantly decreased during the first 20 min of HD, and they were decreased till the third hour of the procedure, whereas the OKT4+/OKT8+ cell number ratio did not chan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02861.x

    authors: Tchórzewski H,Luciak M,Trznadel K,Majewska E,Pokoca L

    更新日期:1989-06-01 00:00:00

  • Standing up with denervated muscles in humans using functional electrical stimulation.

    abstract::The use of electrical stimulation for denervated muscles is still considered to be a controversial issue by many rehabilitation facilities and medical professionals because prior clinical experience has shown that treating denervated muscle tissue using exponential current over a long time period constitutes an imposs...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06376.x

    authors: Kern H,Hofer C,Strohhofer M,Mayr W,Richter W,Stöhr H

    更新日期:1999-05-01 00:00:00

  • Regulatory pathways to the market: an overview.

    abstract::This paper presents an overview of the U.S. Food and Drug Administration's regulatory requirements for introducing medical device and diagnostic products into commercial distribution in the United States. For any specific product, the requirements vary depending upon the product's associated risks, classification, and...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1982.tb04146.x

    authors: Morton WA

    更新日期:1982-11-01 00:00:00

  • Double filtration plasmapheresis for the treatment of rheumatoid arthritis: a study of 21 cases.

    abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00344.x

    authors: Liu JD,Zhang C,Li WS,Lun LD

    更新日期:1997-02-01 00:00:00

  • Ethylene oxide sensitivity in hemodialysis patients.

    abstract::Sera from 138 patients who had experienced hypersensitivity-type reactions while on hemodialysis (reactors) were examined retrospectively by the radioallergosorbent test (RAST) for specific IgE antibody to ethylene oxide (ETO). Seventy-eight hemodialysis patients without a history of reaction were also evaluated as co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02638.x

    authors: Pearson F,Bruszer G,Lee W,Sagona M,Sargent H,Woods E,Dolovich J,Caruana R

    更新日期:1987-04-01 00:00:00

  • Selective inhibition of resistance to hemopoietic allografts but not rejection to a natural killer cell sensitive tumor in transgenic mice for granulocyte colony stimulating factor.

    abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04563.x

    authors: Kokai Y,Kimura H,Matsuura A,Fujimoto J

    更新日期:1996-08-01 00:00:00

  • Hemolysis and heat generation in six different types of centrifugal blood pumps.

    abstract::What the most causative factor affecting hemolysis is still controversial. To resolve this problem, we investigated the relationship between hemolysis and heat generation in six types of centrifugal blood pumps (Bio-Pump, Delphin, Capiox, Nikkiso, Isoflow, and Toyobo). The analyzed parameters were index of hemolysis i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02453.x

    authors: Araki K,Taenaka Y,Masuzawa T,Tatsumi E,Wakisaka Y,Watari M,Nakatani T,Akagi H,Baba Y,Anai H

    更新日期:1995-09-01 00:00:00

  • Forward osmosis process for dialysis fluid regeneration.

    abstract::In a preliminary experiment, 38% of the spent dialysis fluid water was reclaimed by a forward osmosis process through a cellulose triacetate membrane. The simplicity of forward osmosis and its minimal external energy requirements may allow the construction of a small bulk device that can reclaim a considerable portion...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00816.x

    authors: Talaat KM

    更新日期:2009-12-01 00:00:00

  • Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design.

    abstract::Planar particle image velocimetry was used to explore the flow behavior of the newly designed 12-cc Penn State pneumatic pediatric assist pump. Wall shear maps complemented the velocity data. Bjork-Shiley Monostrut 17-mm mechanical heart valves were used in the inlet and outlet ports. In comparison with larger Penn St...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00565.x

    authors: Manning KB,Wivholm BD,Yang N,Fontaine AA,Deutsch S

    更新日期:2008-06-01 00:00:00

  • Electrochemical and Electrophysiological Performance of Platinum Electrodes Within the Ninety-Nine-Electrode Stimulating Nerve Cuff.

    abstract::The trend in neural prostheses using selective nerve stimulation for electrical stimulation therapies is headed toward single-part systems having a large number of working electrodes (WEs), each of which selectively stimulate neural tissue or record neural response (NR). The present article reviews the electrochemical...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12625

    authors: Pečlin P,Mehle A,Karpe B,Rozman J

    更新日期:2015-10-01 00:00:00

  • Combination of plasma exchange and continuous hemofiltration as temporary metabolic support for patients with acute liver failure.

    abstract::The combination of plasma exchange and continuous hemofiltration was applied to patients with acute liver failure, and its clinically advantageous effects were evaluated. This procedure was found to be a powerful approach in decreasing patient morbidity; however, the effect was temporary and the patients finally died....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02217.x

    authors: Matsubara S

    更新日期:1994-05-01 00:00:00

  • Ex vivo evaluation in normal dogs of insulin released by a bioartificial pancreas containing isolated rat islets of Langerhans.

    abstract::In bioartificial pancreatic systems, isolated islets of Langerhans are protected against immune rejection by an artificial membrane, permeable to glucose and insulin, but not to immunoglobulins and lymphocytes. Some of these devices, referred to as vascular systems, are set up to be connected to a vascular site in the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb01588.x

    authors: Lepeintre J,Briandet H,Moussy F,Chicheportiche D,Darquy S,Rouchette J,Imbaud P,Duron JJ,Reach G

    更新日期:1990-02-01 00:00:00

  • Experiencing Functional Electrical Stimulation Roots on Education, and Clinical Developments in Paraplegia and Tetraplegia With Technological Innovation.

    abstract::Cybernetics-based concepts can allow for complete independence for paralyzed individuals, including sensory motor recovery. Spinal cord injuries are responsible for a huge stress on health and a financial burden to society. This article focuses on novel procedures such as functional diagnosis for paraplegics and tetra...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12620

    authors: Varoto R,Cliquet A Jr

    更新日期:2015-10-01 00:00:00

  • Intrinsic coagulation pathway in end-stage renal disease associated with spinal cord injury treated with hemodialysis.

    abstract::Plasma procoagulant activities of factors XII, XI, IX, and VIII and plasma concentrations of factor XII antigen and high molecular weight kininogen (HMK) were determined in nine men with chronic renal failure (CRF) associated with long-standing spinal cord injury (SCI) treated with hemodialysis. The results were compa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04366.x

    authors: Vaziri ND,Winer RL,Toohey J,Danviriyasup K,Alikhani S,Eltorai I,Gordon S,Paule P

    更新日期:1985-05-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Kinetics of group IB and IIA phospholipase A2 during low-volume continuous hemodiafiltration in severe acute pancreatitis.

    abstract::Continuous hemodiafiltration (CHDF) has been performed for the treatment of severe acute pancreatitis. Phospholipase A2 (PLA2) is one of the important mediators which exacerbate acute pancreatitis, but whether PLA2 can be removed by CHDF is unclear. In this study, the kinetics of group IB and group IIA PLA2 was examin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2007.00398.x

    authors: Suzuki M,Okahisa T,Sogabe M,Iwaki H,Okita Y,Ohnishi Y,Ito S

    更新日期:2007-05-01 00:00:00

  • Pretreatment With Inactivated Bacillus Calmette-Guerin Increases CD4+CD25+ Regulatory T Cell Function and Decreases Functional and Structural Effects of Asthma Induction in a Rat Asthma Model.

    abstract::Bacillus Calmette-Guerin (BCG) has been shown to have therapeutic effects on asthma through CD4+CD25+ regulatory T cells (Tregs). We sought to assess pretreatment with inactivated BCG on CD4+CD25+ Tregs and its functional and structural effects in rat asthma model. The rat asthma model was established using ovalbumin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12566

    authors: Gong P,Li Y,Tan YP,Li H

    更新日期:2016-04-01 00:00:00

  • Anterior chest wall axillary artery to contralateral axillary vein graft for vascular access in hemodialysis.

    abstract::Patients with end-stage renal failure and peripheral vascular disease pose a difficult management problem in establishing long-term angioaccess for hemodialysis. In 4 patients with access problems, we created axillary artery to contralateral axillary vein Goretex grafts. The grafts were cannulated regularly for period...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1995.tb02291.x

    authors: Ono K,Muto Y,Yano K,Yukizane T

    更新日期:1995-12-01 00:00:00

  • Hemolysis Related to Turbulent Eddy Size Distributions Using Comparisons of Experiments to Computations.

    abstract::Turbulent blood flow in medical devices contributes to blood trauma, yet the exact mechanism(s) have not been fully elucidated. Local turbulent stresses, viscous stresses, and the rate of dissipation of the turbulent kinetic energy have been proffered as hypotheses to describe and predict blood damage. In this work, s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12572

    authors: Ozturk M,O'Rear EA,Papavassiliou DV

    更新日期:2015-12-01 00:00:00

  • Numerical modeling of blood flow in the ventricular cavity of the artificial heart.

    abstract::The flow of blood as a viscous, Newtonian, incompressible liquid in an expanding spherical cavity with a ball-type inlet valve was examined. This type of flow can serve as a model of the phase of ventricular diastole in a sac-type artificial heart. The critical values of Reynolds numbers at which flow interruption beh...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04170.x

    authors: Starobin IM,Zaĭko VM

    更新日期:1983-02-01 00:00:00