Abstract:
:Patients with end-stage renal failure and peripheral vascular disease pose a difficult management problem in establishing long-term angioaccess for hemodialysis. In 4 patients with access problems, we created axillary artery to contralateral axillary vein Goretex grafts. The grafts were cannulated regularly for periods ranging from 29 to 66 months without difficulty. There was one episode of thrombosis and one of congestive heart failure. The mean venous pressure was 120 mm Hg with a mean arterial flow of 220 ml/min. This type of vascular access can provide adequate blood flow in difficult patients and maintain efficient dialysis. It should be a useful addition to the armamentarium of the vascular surgeon.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Ono K,Muto Y,Yano K,Yukizane Tdoi
10.1111/j.1525-1594.1995.tb02291.xsubject
Has Abstractpub_date
1995-12-01 00:00:00pages
1233-6issue
12eissn
0160-564Xissn
1525-1594journal_volume
19pub_type
临床试验,杂志文章abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1988.tb01529.x
更新日期:1988-02-01 00:00:00
abstract::This study compares the effects of polyethylene glycol (PEG) modified bovine hemoglobin on vascular half-life and renal function in rabbits to those of unmodified bovine hemoglobin. Renal function was assessed by the measurement of the glomerular filtration rate, urinalysis, blood chemistries, hemoglobin (Hb) excretio...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00250.x
更新日期:1997-08-01 00:00:00
abstract::Multiple observational studies along with a limited number of randomized clinical trials suggest that intensive hemodialysis (IHD) not only improves outcomes for uremic patients undergoing chronic dialysis but does so with a more favorable cost/benefit ratio compared with conventional hemodialysis. As a result of this...
journal_title:Artificial organs
pub_type: 历史文章,杂志文章,评审
doi:10.1111/aor.12458
更新日期:2015-09-01 00:00:00
abstract::Bicarbonate balance is usually calculated from the Henderson-Hasselbalch equation under the assumption that pK is constant. To evaluate the pK variability and its effects on bicarbonate computed with autoanalyzers in dialysis patients, we studied 44 patients on maintenance hemodialysis. The pH, PCO2, total CO2, and pK...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02715.x
更新日期:1987-12-01 00:00:00
abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02648.x
更新日期:1987-04-01 00:00:00
abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00735.x
更新日期:1997-05-01 00:00:00
abstract::Doppler ultrasound is a noninvasive technique for monitoring moving objects such as flowing blood while ignoring stationary objects such as shunt tubing. A Doppler system was investigated to determine its sensitivity in detecting particulate release in blood during hemodialysis. Seven hemodialysis procedures with dogs...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1984.tb04275.x
更新日期:1984-05-01 00:00:00
abstract::Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of fl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13610
更新日期:2020-05-01 00:00:00
abstract::The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00951.x
更新日期:2009-11-01 00:00:00
abstract::Late referral (LR) to dialysis therapy has been associated with poor outcomes in people with end-stage renal disease. This had been ascribed to the frequent use of temporary vascular catheters (TVCs) in LR patients. The effects of LR and TVC on the outcomes of an incident hemodialysis population (n = 101) were investi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.00016.x
更新日期:2004-11-01 00:00:00
abstract::We assessed the relationship of certain clinical variables (including bradykinin [BK] release and dialysis membrane) to initial mean arterial pressure (MAP) reduction in 47 patients requiring continuous renal replacement therapy (CRRT) in an intensive care unit. The pretreatment MAP was 84 +/- 14 mm Hg for the group a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.06703.x
更新日期:2001-12-01 00:00:00
abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::Transcatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key. Increased leaflet mechanical stress...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13654
更新日期:2020-07-01 00:00:00
abstract::Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetratin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00514.x
更新日期:1997-09-01 00:00:00
abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1981.tb03980.x
更新日期:1981-05-01 00:00:00
abstract::This article introduces a unique miniaturization process of a magnetically levitated axial flow blood pump from a functional prototype to a pump suitable for animal trials. Through COMSOL three-dimensional finite element analysis and experimental verification, the hybrid magnetic bearings of the pump have been miniatu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01077.x
更新日期:2010-10-01 00:00:00
abstract::In this study a highly biocompatible polymer membrane was prepared by surface modification. An artificial cornea was also developed for clinical applications. Silicone rubber (SR) membrane was grafted with hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and acrylic acid by plasma induced grafted polyme...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb00661.x
更新日期:1996-11-01 00:00:00
abstract::Sera from 138 patients who had experienced hypersensitivity-type reactions while on hemodialysis (reactors) were examined retrospectively by the radioallergosorbent test (RAST) for specific IgE antibody to ethylene oxide (ETO). Seventy-eight hemodialysis patients without a history of reaction were also evaluated as co...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02638.x
更新日期:1987-04-01 00:00:00
abstract::In order to define physiological properties of the autograft root, magnetic resonance imaging (MRI) findings relative to three different operative techniques were compared with those of control subjects. Twenty-three patients, 18/5 M/F, aged 32 ± 9 years, underwent MRI assessment of the aortic root. Patients with norm...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01202.x
更新日期:2011-12-01 00:00:00
abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00289.x
更新日期:1992-04-01 00:00:00
abstract::Filtration through membranes with different nominal cut-off was used for isolation of middle molecule fractions from uremic serum. Comparison was made with test substances which in gel filtration did not show a regular relationship between molecular weight and partition coefficient. The XM50 membrane (cut-off 50,000 D...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::Recently, there has been an increase in the use of rat models of cardiopulmonary bypass (CPB) for research purposes. Much of this work has focused on cerebral injury associated with CPB. Many of these studies employ a peripheral cannulation approach, often utilizing the caudal artery and internal or external jugular v...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00917.x
更新日期:2010-06-01 00:00:00
abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06062.x
更新日期:1998-12-01 00:00:00
abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.06864.x
更新日期:2001-09-01 00:00:00
abstract::We designed a 24-field array and an on-line control box that selects which and how many of 24 fields will conduct electrical charge during functional electrical stimulation. The array was made using a conductive microfiber textile, silver two-component adhesive, and the conductive ink imprint on the polycarbonate. The...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2005.29075.x
更新日期:2005-06-01 00:00:00
abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13626
更新日期:2020-06-01 00:00:00
abstract::The Genius is a convenient single-pass batch hemodialysis system. Dialysate is heated during the preparation phase. Once the container is filled at one of the three available starting temperatures, dialysate cools spontaneously. As dialysate temperature plays an important role in hemodynamic stability, knowledge of th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00981.x
更新日期:2010-12-01 00:00:00
abstract::Wall shear stress on the pump casing cover was measured using a surface-mounted hot-film sensor. In addition, the shear stress distribution in the pump was qualitatively investigated by means of oil-film visualization. The characteristics of shear stress in the pump are discussed, including the results on the oil-film...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00421.x
更新日期:2007-07-01 00:00:00
abstract::To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04189.x
更新日期:1983-05-01 00:00:00
abstract::We developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of thi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13459
更新日期:2019-09-01 00:00:00