The bradykinin response and early hypotension at the introduction of continuous renal replacement therapy in the intensive care unit.

Abstract:

:We assessed the relationship of certain clinical variables (including bradykinin [BK] release and dialysis membrane) to initial mean arterial pressure (MAP) reduction in 47 patients requiring continuous renal replacement therapy (CRRT) in an intensive care unit. The pretreatment MAP was 84 +/- 14 mm Hg for the group as a whole. The initial MAP reduction was 11.5 (7-20) mm Hg, occurring 4 to 8 min after connection. MAP reduction was 9 (6-15) mm Hg with polyacryonitrile (PAN) membranes versus 14 (5-19) mm Hg with polysulfone (PS) (not significant). There were positive correlations between MAP reduction and BK concentration at 3 (BK3; r = 0.58, p < 0.01) and 6 (BK6; r = 0.67, p < 0.001) min with PAN but not with PS. A greater reduction in MAP was seen in patients who were not receiving inotropic support (Mann-Whitney test, p < 0.01). BK3 and BK6 values for the PAN and PS groups were not significantly different. However, BK concentrations greater than 1,000 pg/ml were only seen with PAN (6 patients, MAP reduction 27 [17-31] mm Hg). There were positive (albumin) and negative (age; acute physiology, age, and chronic health evaluation score; C-reactive protein [CRP]; calcium) correlations with BK3/BK6 in the PAN and PS groups, some of which (albumin, CRP) reached statistical significance. In summary, MAP reduction at the start of CRRT correlates with BK concentration. The similarity of response with PAN and PS suggests an importance for other clinical factors. In this study, hemodynamic instability was more likely in patients with evidence of a less severe inflammatory or septic illness.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Stoves J,Goode NP,Visvanathan R,Jones CH,Shires M,Will EJ,Davison AM

doi

10.1046/j.1525-1594.2001.06703.x

subject

Has Abstract

pub_date

2001-12-01 00:00:00

pages

1009-13

issue

12

eissn

0160-564X

issn

1525-1594

pii

6703

journal_volume

25

pub_type

杂志文章
  • Cooling device for bradycardia based on Peltier element for accurate anastomosis of off-pump coronary artery bypass grafting.

    abstract::Upon introducing off-pump coronary artery bypass grafting (CABG), the indications for CABG were expanded to include patients who previously had no operative indications. For accurate anastomosis, various devices and methods have been developed. Bradycardia is easily induced by drug administration. However, this method...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07087.x

    authors: Kuniyoshi Y,Koja K,Miyagi K,Shimoji M,Uezu T,Arakaki K,Yamashiro S,Mabuni K,Senaha S

    更新日期:2002-10-01 00:00:00

  • Internal jugular vein cannulation with two silicone rubber catheters: a new and safe temporary vascular access for hemodialysis. Thirty months' experience.

    abstract::Temporary and immediately usable vascular access is a vital need in treating uremic patients. Subclavian vein cannulation, although a major progress, has been associated with significant morbidity and mortality. Accordingly, for the last 2.5 years the authors have been developing an alternative technique consisting of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02587.x

    authors: Canaud B,Beraud JJ,Joyeux H,Mion C

    更新日期:1986-10-01 00:00:00

  • Predictive Factors Upon Discontinuation of Renal Replacement Therapy for Long-Term Chronic Dialysis and Death in Acute Kidney Injury Patients.

    abstract::The specific timing for discontinuing renal replacement therapy (RRT) in acute kidney injury (AKI) patients is debatable. The predictive abilities of variables at the time of discontinuation of RRT for the long-term prognoses of patients have not been explored. This study aimed to explore the prognostic factors upon d...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12927

    authors: Yang T,Sun S,Lin L,Han M,Liu Q,Zeng X,Zhao Y,Li Y,Su B,Huang S,Yang L

    更新日期:2017-12-01 00:00:00

  • Microbial and endotoxin contamination in water and dialysate in the central United States.

    abstract::The purified water supplies and randomly selected dialysates of 51 chronic and acute dialysis centers in the central United States were surveyed to assess the relative risks to dialysis patients from microbial and endotoxin contamination. A culture medium more sensitive than those generally employed in routine quality...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb01601.x

    authors: Klein E,Pass T,Harding GB,Wright R,Million C

    更新日期:1990-04-01 00:00:00

  • Optimal continuous retrograde coronary perfusion flow rate with beating heart in normal temperature.

    abstract:PURPOSE:We were led to the premise that with retrograde oxygenated blood perfusion, it would be possible to perform operations on the beating heart. METHODS:The experiment consisted of two stages: procedure 1 and 2. In procedure 1, six pigs were used. Retrograde perfusion flow was controlled to be in the range of 5.0-...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47279.x

    authors: Tsukioka T,Tomita S,Watanabe G,Takemura H

    更新日期:2004-03-01 00:00:00

  • Treatment of severe hyperlipidemia: six years' experience with low-density lipoprotein apheresis.

    abstract::In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04455.x

    authors: Bambauer R,Schiel R,Latza R,Klinkmann J

    更新日期:1996-04-01 00:00:00

  • Biological evaluation of liposome-encapsulated hemoglobin surface-modified with a novel PEGylated nonphospholipid amphiphile.

    abstract::Traumatic injury is often associated with hemorrhagic shock. Liposome-encapsulated hemoglobin (LEH) is being developed as an artificial oxygen carrier to address post-hemorrhage oxygen and volume deficit. Here, we report a new composition of LEH based on the use of polyethylene glycol (PEG2K ) conjugated with nonphosp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12304

    authors: Yadav VR,Nag O,Awasthi V

    更新日期:2014-08-01 00:00:00

  • Renal effects of multiple infusion of pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) solution in dogs.

    abstract::Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP), which is made from out-dated human red blood cells by two major chemical modifications, namely pyridoxalation and conjugation with polyoxyethylene (POE), is currently under development as a physiological oxygen carrier. This study assessed the effects of PHP-88...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00424.x

    authors: Takahashi T,Iwasaki K,Malchesky PS,Harasaki H,Matsushita M,Nosé Y,Rolin H 3rd,Hall PM

    更新日期:1993-03-01 00:00:00

  • Extracorporeal endotoxin removal by immobilized polyethylenimine.

    abstract::The neutralization of bacterial endotoxins (ET) is still an unsolved problem in therapeutic medicine. The efficacy of anti-endotoxin antibodies or receptor antagonists and other substances interfering with the endotoxin-induced pathomechanisms is dependent on an intact cellular degradation system of the host. However,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00630.x

    authors: Mitzner S,Schneidewind J,Falkenhagen D,Loth F,Klinkmann H

    更新日期:1993-09-01 00:00:00

  • Characteristics of chronically paced cardiac functions in the congenital complete atrioventricular block.

    abstract::Characteristics of morphology, cardiac function, and cardiac reserve at late state were evaluated at rest, by changing the pacing rates, and after exercise in patients with ventricular pacemakers for isolated congenital complete atrioventricular block. Heart size was reduced statistically after pacemaker implantation,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02667.x

    authors: Nawa S,Kioka Y,Shimizu A,Tsuji H,Miyachi Y,Ebara K,Kino K,Shigenobu M,Murakami T,Senoo Y

    更新日期:1987-06-01 00:00:00

  • Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

    abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02200.x

    authors: Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

    更新日期:1994-04-01 00:00:00

  • Effects of scaling on centrifugal blood pumps.

    abstract::Experimental studies on the effects of scaling on the performance of centrifugal blood pumps were conducted in a closed-loop test rig. For the prototype, eight different impellers of the same outer diameter of 25 mm were tested at 1,500, 2,000, and 2,500 revolutions per minute (rpm) using blood analog as fluid medium....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07119.x

    authors: Wong YW,Chan WK,Yu SC,Chua LP

    更新日期:2002-11-01 00:00:00

  • Clinical use of low porosity woven ultrafine polyester fiber grafts.

    abstract::A woven fabric graft made of ultrafine polyester fibers (UFPF) (Toray Graft, water porosity: 100 ml/min/cm2:120 mm Hg H2O) was clinically applied in 81 cases (28 thoracic aortic aneurysms, 6 thoracoabdominal aortic aneurysms, 42 abdominal aortic aneurysms, and 5 atherosclerotic obstructions of the peripheral arteries)...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02245.x

    authors: Satoh S,Niu S,Kanda K,Hirai J,Nakazima S,Wada Y,Oka T,Noishiki Y

    更新日期:1995-01-01 00:00:00

  • Lixelle adsorbent to remove inflammatory cytokines.

    abstract::A beta2-microglobulin (beta2M) selective adsorbent (Lixelle) for direct hemoperfusion has been used for the treatment of hemodialysis patients with the long-term complication of dialysis related amyloidosis (DRA), but there is no significant correlation between the serum level of beta2M and the occurrence of DRA. Infl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06179.x

    authors: Tsuchida K,Takemoto Y,Nakamura T,Fu O,Okada C,Yamagami S,Kishimoto T

    更新日期:1998-12-01 00:00:00

  • Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

    abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00876.x

    authors: Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

    更新日期:2010-05-01 00:00:00

  • The status of pacemaker implantations in Japan.

    abstract::It has been over 40 years since the initial clinical application of a cardiac pacemaker. Currently, approximately 300 per million patients in the United States and Europe are kept alive owing to the benefit of implantable pacemakers. Recently, the Japanese Cardiac Pacing Society and the Japanese Society of Artificial ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03303.x

    authors: Kojima R

    更新日期:1994-01-01 00:00:00

  • The impact of obesity on outcomes in patients receiving extracorporeal life support.

    abstract::Extracorporeal life support (ECLS) has been increasingly utilized to manage cardiac and pulmonary dysfunction. The impact of obesity on outcomes of ECLS is poorly defined. The purpose of the study was to compare in-hospital mortality, resource use, complications, and readmissions in obese versus non-obese patients rec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13752

    authors: Christian-Miller N,Hadaya J,Nakhla M,Sanaiha Y,Madrigal J,Emami S,Cale M,Sareh S,Benharash P

    更新日期:2020-11-01 00:00:00

  • Effect of electrolyzed water on wound healing.

    abstract::Electrolyzed water accelerated the healing of full-thickness cutaneous wounds in rats, but only anode chamber water (acid pH or neutralized) was effective. Hypochlorous acid (HOCl), also produced by electrolysis, was ineffective, suggesting that these types of electrolyzed water enhance wound healing by a mechanism un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06557-3.x

    authors: Yahagi N,Kono M,Kitahara M,Ohmura A,Sumita O,Hashimoto T,Hori K,Ning-Juan C,Woodson P,Kubota S,Murakami A,Takamoto S

    更新日期:2000-12-01 00:00:00

  • Development and clinical assay of the BCM ventricular assist device.

    abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03364.x

    authors: del Cañizo JF,Antoranz JC,Desco MM,Alvarez-Valdivielso JM,Fernandez-Caleya D,López M,Garcia-Barreno P,Duarte J

    更新日期:1994-07-01 00:00:00

  • Aortic root physiology late after a "perfect" ross operation: magnetic resonance imaging study of three operative techniques.

    abstract::In order to define physiological properties of the autograft root, magnetic resonance imaging (MRI) findings relative to three different operative techniques were compared with those of control subjects. Twenty-three patients, 18/5 M/F, aged 32 ± 9 years, underwent MRI assessment of the aortic root. Patients with norm...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01202.x

    authors: Luciani GB,Viscardi F,Puppini G,Faggian G,Mazzucco A

    更新日期:2011-12-01 00:00:00

  • Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design.

    abstract::Planar particle image velocimetry was used to explore the flow behavior of the newly designed 12-cc Penn State pneumatic pediatric assist pump. Wall shear maps complemented the velocity data. Bjork-Shiley Monostrut 17-mm mechanical heart valves were used in the inlet and outlet ports. In comparison with larger Penn St...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00565.x

    authors: Manning KB,Wivholm BD,Yang N,Fontaine AA,Deutsch S

    更新日期:2008-06-01 00:00:00

  • Flow through an outlet cannula of a rotary ventricular assist device.

    abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06931_4.x

    authors: Manning KB,Miller GE

    更新日期:2002-08-01 00:00:00

  • A Meta-Analysis of Renal Function After Adult Cardiac Surgery With Pulsatile Perfusion.

    abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.12452

    authors: Nam MJ,Lim CH,Kim HJ,Kim YH,Choi H,Son HS,Lim HJ,Sun K

    更新日期:2015-09-01 00:00:00

  • First experiences with outpatient care of patients with implanted axial flow pumps.

    abstract::As known from patients with pulsatile ventricular assist devices (VADs), early mobilization, physical exercise, and return to normal life are essential for optimal recovery. Recently, implantable rotary pumps became available for extended left ventricular support as bridges to transplantation. Modified procedures are ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025005331.x

    authors: Wieselthaler GM,Schima H,Dworschak M,Quittan M,Nuhr M,Czerny M,Seebacher G,Huber L,Grimm M,Wolner E

    更新日期:2001-05-01 00:00:00

  • Assessment of total hip arthroplasty by means of computed tomography 3D models and fracture risk evaluation.

    abstract::Total hip arthroplasty (THA) can be achieved by using a cemented or noncemented prosthesis. Besides patient's age, weight, and other clinical signs, the evaluation of the quality of the bones is a crucial parameter on which orthopedic surgeons base the choice between cemented and noncemented THA. Although bone density...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12033

    authors: Gargiulo P,Pétursson T,Magnússon B,Bifulco P,Cesarelli M,Izzo GM,Magnúsdóttir G,Halldórsson G,Ludvigsdóttir GK,Tribel J,Jónsson H Jr

    更新日期:2013-06-01 00:00:00

  • Short hemodialysis: long-term mortality and morbidity.

    abstract::Individualized short hemodialysis treatment schedules, approximately three 3-h treatments per week, were introduced in a nephrology unit in 1976. In May 1985, 259 patients had been treated, which corresponds to approximately 60 new patients per million inhabitants per year. Ages at start of therapy ranged between 17 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02541.x

    authors: Wauters JP,Bercini-Pansiot S,Gilliard N,Stauffer JC

    更新日期:1986-06-01 00:00:00

  • Development of a Tissue-Engineered Artificial Ligament: Reconstruction of Injured Rabbit Medial Collateral Ligament With Elastin-Collagen and Ligament Cell Composite Artificial Ligament.

    abstract::Ligament reconstruction using a tissue-engineered artificial ligament (TEAL) requires regeneration of the ligament-bone junction such that fixation devices such as screws and end buttons do not have to be used. The objective of this study was to develop a TEAL consisting of elastin-coated polydioxanone (PDS) sutures c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13124

    authors: Hirukawa M,Katayama S,Sato T,Inoue K,Niwa K,Ito N,Hattori T,Hosoi T,Unno H,Suzuki Y,Hasegawa M,Miyamoto K,Horiuchi T

    更新日期:2018-07-01 00:00:00

  • Experimental investigation of pulsatility effect on the deformability and hemolysis of blood cells.

    abstract::In this study, we investigated the differences between pulsatile cardiopulmonary bypass (CPB) procedure and nonpulsatile CPB procedure in terms of their effects on hemolysis and deformability of red blood cells (RBCs) under various shear stress conditions. In order to research the effects on hemolysis and deformabilit...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00974.x

    authors: Kang YJ,Kim MG,Son KH,Lim CH,Son HS,Yoon SY,Kwon HS,Yang S

    更新日期:2010-04-01 00:00:00

  • Changes in Total Cardiac Output and Oxygen Extraction During Exercise in Patients Supported With an HVAD Left Ventricular Assist Device.

    abstract::Following implantation of a left ventricular assist device (LVAD), acceptable functional performance is now being achieved; however, peak VO2 and peak work load (watts) remain considerably limited. Maximum physical capacity is essentially dependent on generated cardiac output (CO) and arteriovenous oxygen difference (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13102

    authors: Schmidt T,Bjarnason-Wehrens B,Mommertz S,Hannig M,Schulte-Eistrup S,Willemsen D,Reiss N

    更新日期:2018-07-01 00:00:00

  • Estimation of phosphene spatial variability for visual prosthesis applications.

    abstract::Visual prostheses are the focus of intensive research efforts to restore some measure of useful vision to blind or near-blind patients. The development of such technology is being guided to an extent by tools that simulate prosthesis behavior for healthy sighted subjects in order to assess system requirements and conf...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00878.x

    authors: Obeid I,Veraart C,Delbeke J

    更新日期:2010-05-01 00:00:00