Treatment of severe hyperlipidemia: six years' experience with low-density lipoprotein apheresis.

Abstract:

:In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of 30 patients, the immunoadsorption system from Baxter for 2 of 30 patients, and the immunoadsorption system with special lipoprotein(a) (Lp[a]) columns from Lipopak for one patient. Prior to the LDL apheresis, 23 of 30 patients suffered from coronary heart disease. Twenty of 23 patients suffered intermittently from symptoms of angina, excertional dyspnea, and claudication. With LDL apheresis, reductions of 47% for total cholesterol, 49% for LDL, 26% for Lp(a), and 40% for triglycerides were reached. Severe side effects such as shock or allergic reactions were very rare (0.55%). In the course of treatment with LDL apheresis, an improvement in general well-being and increased performance were experienced in 27 of 30 patients. A reduction of nitrate medication between 60 and 100% was observed in 17 of 23 patients. The present data clearly demonstrate that treatment with LDL apheresis in patients suffering from severe familial hyperlipidemia, resistant to maximum conservative therapy, is very effective and safe even over long periods of time.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Bambauer R,Schiel R,Latza R,Klinkmann J

doi

10.1111/j.1525-1594.1996.tb04455.x

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

336-9

issue

4

eissn

0160-564X

issn

1525-1594

journal_volume

20

pub_type

临床试验,杂志文章
  • Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

    abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06594.x

    authors: Mesana T,Collart F,Caus T,Pomane C,Graziani N,Bruder N,Dufour H,Grisoli F,Montiès JR

    更新日期:2000-06-01 00:00:00

  • Serum hyaluronic acid and interleukin-6 as possible markers of carpal tunnel syndrome in chronic hemodialysis patients.

    abstract::To elucidate the precise mechanism of carpal tunnel syndrome (CTS), serum hyaluronic acid (HA), interleukin-1 beta (IL-1 beta), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha) were measured in 71 chronic hemodialysis patients with or without CTS and/or shoulder pain. Patients were divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02227.x

    authors: Takasu S,Takatsu S,Kunitomo K,Kokumai Y

    更新日期:1994-06-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

    abstract::Secondary flow in the centrifugal blood pump helps to enhance the washout effect and to minimize thrombus formation. On the other hand, it has an adverse effect on pump efficiency. Excessive secondary flow may induce hemolytic effects. Understanding the secondary flow is thus important to the design of a compact, effi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29012.x

    authors: Watanabe N,Masuda T,Iida T,Kataoka H,Fujimoto T,Takatani S

    更新日期:2005-01-01 00:00:00

  • Comparison of a New Miniaturized Extracorporeal Membrane Oxygenation System With Integrated Rotary Blood Pump to a Standard System in a Porcine Model of Acute Lung Injury.

    abstract::Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) wa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12611

    authors: Pilarczyk K,Heckmann J,Lyskawa K,Strauß A,Haake N,Wiese I,Jakob H,Kamler M,Pizanis N

    更新日期:2016-07-01 00:00:00

  • Evaluation of perfusion modes on vital organ recovery and thyroid hormone homeostasis in pediatric patients undergoing cardiopulmonary bypass.

    abstract::The objectives of this study were: (i) to evaluate the effects of perfusion modes (pulsatile vs. nonpulsatile) on vital organs recovery and (ii) to investigate the influences of two different perfusion modes on the homeostasis of thyroid hormones in pediatric patients undergoing cardiopulmonary bypass (CPB) procedures...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2010.01159.x

    authors: Akçevin A,Alkan-Bozkaya T,Qiu F,Undar A

    更新日期:2010-11-01 00:00:00

  • Cytotoxicity and genotoxicity of bovine pericardium preserved in glycerol.

    abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00542.x

    authors: Rodas AC,Maizato MJ,Leirner AA,Pitombo RN,Polakiewicz B,Beppu MM,Higa OZ

    更新日期:2008-04-01 00:00:00

  • Myocardial protection in pediatric cardiac surgery.

    abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12029

    authors: Turkoz R

    更新日期:2013-01-01 00:00:00

  • Influence of reuse and of reuse sterilants on the first-use syndrome.

    abstract::Over a 4 year period, five of 98 patients at our dialysis unit developed signs and symptoms consistent with first-use syndrome (FUS). Marked improvement was noted after subjecting new dialyzers to automated processing using either formaldehyde or peracetic acid. No episodes of FUS occurred in patients being treated wi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02645.x

    authors: Vanholder R,Ringoir S

    更新日期:1987-04-01 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Modified DALI LDL-apheresis using trisodium citrate anticoagulation plus bicarbonate or lactate-buffered hemofiltration substitution fluids as primers.

    abstract:BACKGROUND:DALI (direct adsorption of lipids) is the first LDL-apheresis technique able to adsorb low-density lipoprotein (LDL) and lipoproteina) directly from whole blood. In the standard procedure, acid citrate dextrose (ACD-A) is used as anticoagulation and the adsorber is rinsed with a specially manufactured primin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2003.07104.x

    authors: Bosch T,Wendler T,Maschke H

    更新日期:2003-06-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Impact of hemoglobin concentration and affinity for oxygen on tissue oxygenation: the case of hemoglobin-based oxygen carriers.

    abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01296.x

    authors: Samaja M,Terraneo L

    更新日期:2012-02-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Dialyzer reuse: interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing.

    abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04418.x

    authors: Ng YY,Yang AH,Wong KC,Lan HY,Hung TL,Kerr PG,Huang TP

    更新日期:1996-01-01 00:00:00

  • What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

    abstract::Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately cont...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12702

    authors: Naito N,Nishimura T,Takewa Y,Kishimoto S,Date K,Umeki A,Ando M,Ono M,Tatsumi E

    更新日期:2016-11-01 00:00:00

  • Influence of middle molecules on the anemia of uremic patients.

    abstract::To evaluate their toxicity at the cellular level, middle molecules from uremic serum were incubated with erythrocytes from healthy subjects and the activity of the enzyme Delta-aminolevulinic acid dehydrase (D-ALA-D) and peroxidative hemolysis were investigated. Uremic middle molecules caused a significant decrease of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01626.x

    authors: Leber HW,Spiegelhalter R,Ulm A,Goubeaud G,Rawer P

    更新日期:1978-11-01 00:00:00

  • Development of a Tissue-Engineered Artificial Ligament: Reconstruction of Injured Rabbit Medial Collateral Ligament With Elastin-Collagen and Ligament Cell Composite Artificial Ligament.

    abstract::Ligament reconstruction using a tissue-engineered artificial ligament (TEAL) requires regeneration of the ligament-bone junction such that fixation devices such as screws and end buttons do not have to be used. The objective of this study was to develop a TEAL consisting of elastin-coated polydioxanone (PDS) sutures c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13124

    authors: Hirukawa M,Katayama S,Sato T,Inoue K,Niwa K,Ito N,Hattori T,Hosoi T,Unno H,Suzuki Y,Hasegawa M,Miyamoto K,Horiuchi T

    更新日期:2018-07-01 00:00:00

  • Phosphorylcholine and poly(D,L-lactic acid) containing copolymers as substrates for cell adhesion.

    abstract::Fibroblast cell culture was performed to evaluate cell adhesion and cell morphology on novel hydrolyzable copolymers composed of poly(D,L-lactic acid) (PDLA) macromonomer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and n-butyl methacrylate. The copolymers were used as cell culture materials for regulating the int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07015.x

    authors: Watanabe J,Ishihara K

    更新日期:2003-03-01 00:00:00

  • Cerebral oxygen metabolism during total body flow and antegrade cerebral perfusion at deep and moderate hypothermia.

    abstract::The aim of this study is to evaluate the effect of temperature on cerebral oxygen metabolism at total body flow bypass and antegrade cerebral perfusion (ACP). Neonatal piglets were put on cardiopulmonary bypass (CPB) with the initial flow rate of 200mL/kg/min. After cooling to 18°C (n=6) or 25°C (n=7), flow was reduce...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01131.x

    authors: Sasaki T,Boni L,Riemer RK,Yeung JT,Ramamoorthy C,Beckman R,Gisner C,Shuttleworth P,Hanley FL,Reddy VM

    更新日期:2010-11-01 00:00:00

  • Experimental setup to evaluate the performance of percutaneous pulmonary valved stent in different outflow tract morphologies.

    abstract::Percutaneous pulmonary valve implantation is a potential treatment for right ventricular outflow tract (RVOT) dysfunction. However, RVOT implantation site varies among subjects and the success of the procedure depends on RVOT morphology selection. The aim of this study was to use in vitro testing to establish percutan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00673.x

    authors: Vismara R,Laganà K,Migliavacca F,Schievano S,Coats L,Taylor A,Bonhoeffer P

    更新日期:2009-01-01 00:00:00

  • Mathematical modeling of fluid dynamics in pulsatile cardiopulmonary bypass.

    abstract::The design criteria of an extracorporeal circuit suitable for pulsatile flow are quite different and more entangled than for steady flow. The time and costs of the design process could be reduced if mutual influences between the pulsatile pump and other extracorporeal devices were considered without experimental trial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.47197.x

    authors: Pennati G,Fiore GB,Laganà K,Fumero R

    更新日期:2004-02-01 00:00:00

  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • Fluid-Structure Interactions Analysis of Shear-Induced Modulation of a Mesenchymal Stem Cell: An Image-Based Study.

    abstract::Although effects of biochemical modulation of stem cells have been widely investigated, only recent advances have been made in the identification of mechanical conditioning on cell signaling pathways. Experimental investigations quantifying the micromechanical environment of mesenchymal stem cells (MSCs) are challengi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12547

    authors: Ghaemi RV,Vahidi B,Sabour MH,Haghighipour N,Alihemmati Z

    更新日期:2016-03-01 00:00:00

  • Heparin-conjugated poly(lactic-co-glycolic acid) nanospheres enhance large-wound healing by delivering growth factors in platelet-rich plasma.

    abstract::Platelet-rich plasma (PRP) contains many growth factors that are involved in tissue regeneration processes. For successful tissue regeneration, protein growth factors require a delivery vehicle for long-term and sustained release to a defect site in order to maintain their bioactivity. Previously, we showed that hepar...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12389

    authors: La WG,Yang HS

    更新日期:2015-04-01 00:00:00

  • Systemic consequences of ventricular assist devices: alterations of coagulation, immune function, inflammation, and the neuroendocrine system.

    abstract::Implantable ventricular assist devices have proven efficacious as a bridge to transplantation and as a bridge to recovery. Although current indications for use of assist devices are somewhat limited, they are likely to expand in the upcoming years, including their use as destination therapy for end-stage heart failure...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07122.x

    authors: Hampton CR,Verrier ED

    更新日期:2002-11-01 00:00:00

  • Intraarterial perfusion of the hindlimb with pyridoxalated hemoglobin polyoxyethylene conjugate solution in anesthetized dogs.

    abstract::To evaluate the potential clinical usefulness of a modified hemoglobin, pyridoxalated hemoglobin polyoxyethylene conjugate (PHP), the hindlimb vascular bed was perfused with PHP solution while monitoring tissue oxygen tension (PtO2) in anesthetized dogs. The hindlimb region was perfused through the external iliac arte...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02371.x

    authors: Kida Y,Yamakawa T,Iwasaki S,Furusho N,Kadowaki Y,Iwata S,Iwashita Y,Nishi K

    更新日期:1995-06-01 00:00:00

  • The compliance problem: a major obstacle in the development of implantable blood pumps.

    abstract::The compliance problem represents a major obstacle in the development of implantable blood pumps. The motor-driven pumps are enclosed in an airtight casing with gas in the motor space. The trapped gas in the motor space either increases the load on the motor during systole or impedes blood sac filling. Potential solut...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04248.x

    authors: Lee S,Rosenberg G,Donachy JH,Wisman CB,Pierce WS

    更新日期:1984-02-01 00:00:00

  • Flow visualization study on centrifugal blood pump using a high speed video camera.

    abstract::Flow visualization is widely applied to evaluate rotary blood pumps; however, it is very difficult to visualize flow near the vanes of centrifugal blood pumps because the rotational speed of the impeller is usually several thousand rpm. In this study, a tracer method with a high speed video camera that can take more t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02399.x

    authors: Sakuma I,Tadokoro H,Fukui Y,Dohi T

    更新日期:1995-07-01 00:00:00

  • Magnevad status of design improvements human blood results and preliminary sheep trial.

    abstract::Magnevad II is an improved version of Magnevad I and both are fourth-generation axial flow left ventricular assist devices. A major simplification has been implemented and tested. Magnevad I used a magnetically suspended rotor requiring active axial control. Magnevad II is completely passive but otherwise similar. A s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29113.x

    authors: Goldowsky M,Lafaro R,Reed G

    更新日期:2005-10-01 00:00:00