Phosphorylcholine and poly(D,L-lactic acid) containing copolymers as substrates for cell adhesion.

Abstract:

:Fibroblast cell culture was performed to evaluate cell adhesion and cell morphology on novel hydrolyzable copolymers composed of poly(D,L-lactic acid) (PDLA) macromonomer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and n-butyl methacrylate. The copolymers were used as cell culture materials for regulating the interaction between the cells and the polymer surface. The results of X-ray photoelectron spectroscopy (XPS) confirmed that the PDLA chains and MPC units were present in the copolymer coating on PET films. Cell adhesion and morphology of adherent cells on coatings of the copolymers were studied. The number of cells on the surface increased with the PDLA content of the copolymer. As for the cell morphology, a round shape was observed on copolymers containing MPC units. These findings suggest that the cells recognize the PDLA and MPC units on the surface via changes in protein adsorption and/or conformation, and that the numbers of adhering cells and the cell morphology can be regulated by the composition of the copolymer.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Watanabe J,Ishihara K

doi

10.1046/j.1525-1594.2003.07015.x

subject

Has Abstract

pub_date

2003-03-01 00:00:00

pages

242-8

issue

3

eissn

0160-564X

issn

1525-1594

pii

7015

journal_volume

27

pub_type

杂志文章
  • Extracorporeal membrane oxygenator compatible with centrifugal blood pumps.

    abstract::Coil-type silicone membrane oxygenators can only be used with roller blood pumps due to the resistance from the high blood flow. Therefore, during extracorporeal membrane oxygenation (ECMO) treatment, the combination of a roller pump and an oxygenator with a high blood flow resistance will induce severe hemolysis, whi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07117.x

    authors: Motomura T,Maeda T,Kawahito S,Matsui T,Ichikawa S,Ishitoya H,Kawamura M,Nishimura I,Shinohara T,Oestmann D,Glueck J,Kawaguchi Y,Sato K,Nosé Y

    更新日期:2002-11-01 00:00:00

  • Hepatocyte culture between woven capillary networks: a microscopy study.

    abstract::A multi-compartment capillary membrane culture model with independently perfused three-dimensionally woven capillaries was developed for immobilization of hepatocytes in bioreactors. This enables spatial restructuring of cells and enhanced mass transfer performance with more efficient oxygenation and metabolite exchan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02181.x

    authors: Gerlach J,Schnoy N,Smith MD,Neuhaus P

    更新日期:1994-03-01 00:00:00

  • Ultrasonic pulsed Doppler blood flowmeter for use in extracorporeal circulation.

    abstract::In cardiac surgeries, it is frequently necessary to make the external blood circulation and oxygenation artificially. This procedure is called extracorporeal circulation (EC) or heart-lung bypass. During EC, one of the most important parameters, which demands continuous monitoring, is the blood flow. In many cases, th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06532.x

    authors: Dantas RG,Costa ET

    更新日期:2000-03-01 00:00:00

  • Morphological characteristics and proliferation of keratocytes cultured under simulated microgravity.

    abstract::This study probed the changes of keratocytes cultured under simulated microgravity. Keratocytes were isolated from rabbit corneas using collagenase digestion method. Cells were seeded in a 55-mL capacity high-aspect-ratio vessel (HARV) of rotary cell culture system (RCCS) at a density of 1 x 10(4) cells/mL. Dehydrated...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00440.x

    authors: Chen J,Chen R,Gao S

    更新日期:2007-09-01 00:00:00

  • Fluid dynamic characteristics of the VentrAssist rotary blood pump.

    abstract::The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06584.x

    authors: Tansley G,Vidakovic S,Reizes J

    更新日期:2000-06-01 00:00:00

  • Zero-balance ultrafiltration of the priming blood modifies the priming components and improves the clinical outcome in infants undergoing cardiopulmonary bypass: A randomized controlled trial.

    abstract::Cardiopulmonary bypass (CPB) requirement in infants presents a unique challenge because of the large prime volume-to-blood volume ratio. Packed red blood cells (PRBCs) tend to deteriorate with long-term storage owing to their unphysiological composition and osmolality. Given that blood priming is inevitable in neonate...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.13559

    authors: Gholampour Dehaki M,Niknam S,Bakhshandeh H,Azarfarin R

    更新日期:2020-03-01 00:00:00

  • A new smartphone-based method for wound area measurement.

    abstract::Proper wound healing can be assessed by monitoring the wound surface area. Its reduction by 10 or 50% should be achieved after 1 or 4 weeks, respectively, from the start of the applied therapy. There are various methods of wound area measurement, which differ in terms of the cost of the devices and their accuracy. Thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12169

    authors: Foltynski P,Ladyzynski P,Wojcicki JM

    更新日期:2014-04-01 00:00:00

  • Clinical Assessment of Histidine-Tryptophan-Ketoglutarate Solution and Modified St. Thomas' Solution in Pediatric Cardiac Surgery of Tetralogy of Fallot.

    abstract::The objective of this study is to compare the myocardium protective effect of Bretschneider's histidine-tryptophan-ketoglutarate (HTK) solution versus Modified St. Thomas' (STH) solution in pediatric cardiac surgery of Tetralogy of Fallot (TOF). Seventy-seven pediatric patients of TOF who received the total surgical r...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12771

    authors: Wang ZH,An Y,Du MC,Qin TJ,Liu YB,Xu HZ,Yang LQ

    更新日期:2017-05-01 00:00:00

  • Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.

    abstract::The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00339.x

    authors: Malagutti N,Karantonis DM,Cloherty SL,Ayre PJ,Mason DG,Salamonsen RF,Lovell NH

    更新日期:2007-01-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • Influence of different heparin concentrations on the results of in vitro investigations in plasmaseparation technology using capillary membrane filters.

    abstract::Capillary membrane filters are devices commonly used for plasmapheresis and recirculating detoxification systems, including plasmaseparation units. Besides clinical trials and case reports, research on plasmafiltration techniques is carried out using in vitro systems. Notably, such hemoperfused in vitro systems requir...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07132.x

    authors: Unger JK,Haltern C,Dohmen B,Rossaint R

    更新日期:2003-07-01 00:00:00

  • An In Vitro Feasibility Study of the Influence of Configurations and Leaflet Thickness on the Hydrodynamics of Deformed Transcatheter Aortic Valve.

    abstract::Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. Even in the same deformation, the leaflets made in different tissue thickne...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12833

    authors: Feng W,Yang X,Liu Y,Fan Y

    更新日期:2017-08-01 00:00:00

  • Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    abstract::In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in w...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1525-1594.2011.01265.x

    authors: da Silva I,Horikawa O,Cardoso JR,Camargo FA,Andrade AJ,Bock EG

    更新日期:2011-05-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Femoro-femoral versus atrio-aortic extracorporeal membrane oxygenation: selecting the ideal cannulation technique.

    abstract::Veno-arterial extracorporeal membrane oxygenation (ECMO) may be implanted using peripheral ECMO (pECMO) or central ECMO (cECMO) cannulation techniques. The aim of this study was to compare the outcome between these two cannulation techniques. A retrospective study was performed at Düsseldorf University Hospital from O...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.12245

    authors: Saeed D,Stosik H,Islamovic M,Albert A,Kamiya H,Maxhera B,Lichtenberg A

    更新日期:2014-07-01 00:00:00

  • Elective decompression of the left ventricle in pediatric patients may reduce the duration of venoarterial extracorporeal membrane oxygenation.

    abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12390

    authors: Hacking DF,Best D,d'Udekem Y,Brizard CP,Konstantinov IE,Millar J,Butt W

    更新日期:2015-04-01 00:00:00

  • Significant left ventricular unloading with transaortic catheter venting during venoarterial bypass.

    abstract::Insufficient unloading of the left ventricle with blood stagnation is a main cause of unsuccessful left ventricular (LV) recovery during percutaneous cardiopulmonary support (PCPS). The purpose of this investigation was to evaluate the effectiveness of transaortic catheter venting (TACV) for LV unloading. Six adult mo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03744.x

    authors: Shibuya M,Kitamura M,Kurihara H,Kikuchi C,Endo M,Koyanagi H

    更新日期:1997-07-01 00:00:00

  • The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

    abstract::Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06017.x

    authors: Undar A,Lodge AJ,Daggett CW,Runge TM,Ungerleider RM,Calhoon JH

    更新日期:1998-08-01 00:00:00

  • Myocardial protection in pediatric cardiac surgery.

    abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12029

    authors: Turkoz R

    更新日期:2013-01-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • The BiVACOR rotary biventricular assist device: concept and in vitro investigation.

    abstract::The BiVACOR is a novel rotary Biventricular Assist Device (BiVAD) undergoing development to treat global end-stage heart failure. The design includes left and right vanes positioned on a shared rotating hub to form a double-sided magnetically and hydrodynamically suspended centrifugal impeller. The performance of the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00633.x

    authors: Timms D,Fraser J,Hayne M,Dunning J,McNeil K,Pearcy M

    更新日期:2008-10-01 00:00:00

  • Application of computational fluid dynamics techniques to blood pumps.

    abstract::Present-day computational fluid dynamics (CFD) techniques can be used to analyze the behavior of fluid flow in a variety of pumps. CFD can be a powerful tool during the design stage for rapid virtual prototyping of different designs, analyzing performance parameters, and making design improvements. Computational flow ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Sukumar R,Athavale MM,Makhijani VB,Przekwas AJ

    更新日期:1996-06-01 00:00:00

  • Association among serum fetuin-A level, coronary artery calcification, and bone mineral densitometry in maintenance hemodialysis patients.

    abstract::Patients with end-stage renal disease have a very high prevalence and extent of arterial calcification. A number of studies suggest that similar pathophysiologic mechanisms are responsible for development and progression of calcification of atherosclerotic plaque and bone formation. Fetuin-A is a potent calcification ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00814.x

    authors: Kirkpantur A,Altun B,Hazirolan T,Akata D,Arici M,Kirazli S,Turgan C

    更新日期:2009-10-01 00:00:00

  • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

    abstract::Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06426.x

    authors: Akimoto T,Yamazaki K,Litwak P,Litwak KN,Tagusari O,Mori T,Antaki JF,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:1999-08-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Baroreflex sensitivity of an arterial wall during rotary blood pump assistance.

    abstract::It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex sy...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00864.x

    authors: Yambe T,Imachi K,Shiraishi Y,Yamaguchi T,Shibata M,Kameyama T,Yoshizawa M,Sugita N

    更新日期:2009-09-01 00:00:00

  • A novel in vitro assessment of tissue valve calcification by a continuous flow type method.

    abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06482-2.x

    authors: Park JC,Hwang YS,Han DW,Suh H

    更新日期:2000-02-01 00:00:00

  • Failure of platelet markers to evaluate membrane biocompatibility during a combined hemodialysis-hemoperfusion treatment.

    abstract::Plasma levels of the platelet markers beta-thromboglobulin (beta-TG) and platelet factor 4 (PF4) are among the most sophisticated indexes of biocompatibility available to evaluate new members for hemodialysis. This investigation was designed to determine the extent of platelet activation by measuring the alpha-granule...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb00954.x

    authors: Buccianti G,Giaretto S,Pogliani EM,Lorenz M,Valenti G,Bianchi ML,Cresseri D

    更新日期:1987-10-01 00:00:00

  • Effect of electrolyzed water on wound healing.

    abstract::Electrolyzed water accelerated the healing of full-thickness cutaneous wounds in rats, but only anode chamber water (acid pH or neutralized) was effective. Hypochlorous acid (HOCl), also produced by electrolysis, was ineffective, suggesting that these types of electrolyzed water enhance wound healing by a mechanism un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06557-3.x

    authors: Yahagi N,Kono M,Kitahara M,Ohmura A,Sumita O,Hashimoto T,Hori K,Ning-Juan C,Woodson P,Kubota S,Murakami A,Takamoto S

    更新日期:2000-12-01 00:00:00

  • In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.

    abstract::The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygen...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12912

    authors: Wang S,Caneo LF,Jatene MB,Jatene FB,Cestari IA,Kunselman AR,Ündar A

    更新日期:2017-09-01 00:00:00