:Ligament reconstruction using a tissue-engineered artificial ligament (TEAL) requires regeneration of the ligament-bone junction such that fixation devices such as screws and end buttons do not have to be used. The objective of this study was to develop a TEAL consisting of elastin-coated polydioxanone (PDS) sutures covered with elastin and collagen fibers preseeded with ligament cells. In a pilot study, a ring-type PDS suture with a 2.5 mm (width) bone insertion was constructed with/without elastin coating (Ela-coat and Non-coat) and implanted into two bone tunnels, diameter 2.4 mm, in the rabbit tibia (6 cases each) to access the effect of elastin on the bond strength. PDS specimens taken together with the tibia at 6 weeks after implantation indicated growth of bone-like hard tissues around bone tunnels accompanied with narrowing of the tunnels in the Ela-coat group and not in the Non-coat group. The drawout load of the Ela-coat group was significantly higher (28.0 ± 15.1 N, n = 4) than that of the Non-coat group (7.6 ± 4.6 N, n = 5). These data can improve the mechanical bulk property of TEAL through extracellular matrix formation. To achieve this TEAL model, 4.5 × 106 ligament cells were seeded on elastin and collagen fibers (2.5 cm × 2.5 cm × 80 µm) prior to coil formation around the elastin-coated PDS core sutures having ball-shape ends with a diameter of 2.5 mm. Cell-seeded and cell-free TEALs were implanted across the femur and the tibia through bone tunnels with a diameter of 2.4 mm (6 cases each). There was no incidence of TEAL being pulled in 6 weeks. Regardless of the remarkable degradation of PDS observed in the cell-seeded group, both the elastic modulus and breaking load of the cell-seeded group (n = 3) were comparable to those of the sham-operation group (n = 8) (elastic modulus: 15.4 ± 1.3 MPa and 18.5 ± 5.7 MPa; breaking load: 73.0 ± 23.4 N and 104.8 ± 21.8 N, respectively) and higher than those of the cell-free group (n = 5) (elastic modulus: 5.7 ± 3.6 MPa; breaking load: 48.1 ± 11.3 N) accompanied with narrowed bone tunnels and cartilage matrix formation. These data suggest that elastin increased the bond strength of TEAL and bone. Furthermore, our newly developed TEAL from elastin, collagen, and ligament cells maintained the strength of the TEAL even if PDS was degraded.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Hirukawa M,Katayama S,Sato T,Inoue K,Niwa K,Ito N,Hattori T,Hosoi T,Unno H,Suzuki Y,Hasegawa M,Miyamoto K,Horiuchi Tdoi
10.1111/aor.13124subject
Has Abstractpub_date
2018-07-01 00:00:00pages
736-745issue
7eissn
0160-564Xissn
1525-1594journal_volume
42pub_type
杂志文章abstract::Coil-type silicone membrane oxygenators can only be used with roller blood pumps due to the resistance from the high blood flow. Therefore, during extracorporeal membrane oxygenation (ECMO) treatment, the combination of a roller pump and an oxygenator with a high blood flow resistance will induce severe hemolysis, whi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.07117.x
更新日期:2002-11-01 00:00:00
abstract::A small and light direct-drive centrifugal pump has been developed for cardiopulmonary bypass. In the development process, blood compatibility studies including a hemolysis study, an in vitro fluid dynamic performance study, and in vivo durability and feasibility studies were performed. The centrifugal pump with a 50 ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00558.x
更新日期:1992-12-01 00:00:00
abstract::To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, re...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb00718.x
更新日期:1996-02-01 00:00:00
abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.025001053.x
更新日期:2001-01-01 00:00:00
abstract::Tissue engineering of cardiovascular structures represents a novel approach to improve clinical strategies in heart valve disease treatment. The aim of this study was to engineer decellularized atrioventricular heart valve neoscaffolds with an intact ultrastructure and to reseed them with umbilical cord-derived endoth...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12321
更新日期:2014-07-01 00:00:00
abstract::Patients receiving mechanical circulatory support often present with heightened inflammation and free radical production associated with pre-existing conditions in addition to that which is due to blood interactions with nonbiological surfaces. The aim of this experimental laboratory study was to assess the deformabil...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12997
更新日期:2018-02-01 00:00:00
abstract::The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.07250.x
更新日期:2003-05-01 00:00:00
abstract::Many patients all over the world suffer from acute wounds caused by traumas or burns. In most crucial cases, skin regeneration cannot be promoted spontaneously, and skin grafts are applied as the main treatment. However, this therapy has some drawbacks which motivate researchers to develop wound dressings. In this stu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12682
更新日期:2016-08-01 00:00:00
abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03403.x
更新日期:1994-09-01 00:00:00
abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1525-1594.2006.00275.x
更新日期:2006-08-01 00:00:00
abstract::In a multicenter study including 5 dialysis units, blood acetate changes during 4 h dialysis sessions in 141 patients treated with a 4 mM acetate-containing bicarbonate dialysate (ABD) were evaluated and compared to the values of 114 patients using an acetate-free bicarbonate dialysate (AFD). Acetate-free bicarbonate ...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1046/j.1525-1594.1998.06205.x
更新日期:1998-07-01 00:00:00
abstract::One of the most important factors that seems to be involved in total hip replacement is periprosthetic osteolysis. As it is well documented that several interleukins (ILs) are triggered in periprosthetic osteolysis, this article investigates the role of five ILs in primary and replacement total hip arthroplasty, under...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00736.x
更新日期:2009-07-01 00:00:00
abstract::Liposome-encapsulated hemoglobin (LEH) was proven to be protective in cerebral ischemia/reperfusion injury. The present study evaluated LEH in a rat model of permanent middle cerebral artery (MCA) occlusion to clarify its effect during ischemia and reperfusion. Five minutes after thread occlusion of the MCA, rats were...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00700.x
更新日期:2009-02-01 00:00:00
abstract::Total hip arthroplasty (THA) can be achieved by using a cemented or noncemented prosthesis. Besides patient's age, weight, and other clinical signs, the evaluation of the quality of the bones is a crucial parameter on which orthopedic surgeons base the choice between cemented and noncemented THA. Although bone density...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12033
更新日期:2013-06-01 00:00:00
abstract::Aseptic joint loosening is a key factor that reduces the life span of arthroplasty. There are currently few effective treatments for joint loosening except surgical revision. We explored the inhibitory effects of tumor necrosis factor (TNF)-alpha-targeted small interfering RNA (siRNA) on particle-induced inflammatory ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01175.x
更新日期:2011-07-01 00:00:00
abstract::For the last few years we have attempted to separate and isolate from biological fluids the uremic Middle Molecules (MM). The first step in the treatment of plasma is an ultrafiltration through AN69 membrane. The samples are fractionated by Sephadex G-15 chromatography into 9 peaks "a" to "i' under precise conditions ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::The polymer poly(ε-caprolactone) (PCL) has been used in the biomaterial field for its relatively inexpensive price and suitability for modification. Also, its chemical and biological properties are desirable for biomedical applications. The electrospinning process has been used for producing polymer fibers of PCL due ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13713
更新日期:2020-08-01 00:00:00
abstract::Flow visualization experiments and computational fluid dynamic (CFD) analyses were performed and the results were compared to clarify the detailed fluid dynamic characteristics for the prototype design of a centrifugal pump, namely, an implantable ventricular assist system from Sun Medical, whose hemocompatibility was...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.07161.x
更新日期:2004-05-01 00:00:00
abstract::We compared in vitro rates of hemolysis for a recently developed centrifugal pump with a conventional roller pump (10-10-00; Stöckert, Munich, Germany). Flow rates of 0.3 L/min and 1 L/min and a pressure of 200 mm Hg were chosen to simulate conditions during neonatal extracorporeal membrane oxygenation (ECMO). There w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04485.x
更新日期:1996-05-01 00:00:00
abstract::The aim of this study was to characterize and compare human great saphenous veins (HGSVs), HGSV cryoallografts, expanded polytetrafluoroethylene (ePTFE) segments, and elastic and muscular arteries' biomechanics, so as to identify if the biomechanical coupling and the HGSV advantages with respect to ePTFE depend on the...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00467.x
更新日期:2007-11-01 00:00:00
abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13626
更新日期:2020-06-01 00:00:00
abstract::Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requiremen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12664
更新日期:2016-10-01 00:00:00
abstract::Contamination of a ventriculoatrial shunt (VAS) with skin organisms that are usually nonpathogenic may be followed by an immunologically mediated renal injury. The bacteria characteristically involved are coagulase-negative Staphylococci (e.g., Staphylococcus epidermidis), which strongly adhere to the plastic surface ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00617.x
更新日期:1993-08-01 00:00:00
abstract::The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n = 20). The root canals were instrumented...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12675
更新日期:2016-08-01 00:00:00
abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01016.x
更新日期:2011-01-01 00:00:00
abstract::Oxidative stress is crucial in red blood cell (RBC) damage induced by activated neutrophils in in vitro experiments. The aim of the study was to evaluate whether the bioincompatibility phenomena occurring during hemodialysis (HD) (where neutrophil activation with increased free radical production is well documented) m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06432.x
更新日期:2000-01-01 00:00:00
abstract::One hundred and seventy-two patients at The Methodist Hospital in Houston, Texas, were placed on BioMedicus centrifugal ventricular support. One hundred thirty-nine patients were male and 33 were female with a mean age of 59.7 years. Reasons for support were postcardiotomy cardiac failure (129 patients), cardiac allog...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02419.x
更新日期:1995-07-01 00:00:00
abstract::To date, single-needle (SN) hemodialysis (HD) requires a dialysis machine equipped with two blood pumps-one controlling arterial blood flow (Qb) and one controlling venous Qb. B. Braun has developed an innovative single-pump SN HD system. Therefore, usability is improved by reducing complexity. The aim of this study w...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/aor.13149
更新日期:2018-08-01 00:00:00
abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02279.x
更新日期:1995-11-01 00:00:00
abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb02200.x
更新日期:1994-04-01 00:00:00